At least 217 records · Page 12

Flicker Mitigation for a Grid-Connected Tidal and River Power Generator Using the BESS

In the grid-connected tidal and river power generation, the water turbulence and the grid condition can induce the fluctuating output power. This power fluctuation may cause a power quality issue such as flicker, or voltage fluctuations, during the continuous operation. Hence, it is important to assess flicker emission and to mitigate flicker in order to solve this power quality issue. This paper proposes a Battery Energy Storage System (BESS)installed between the power converters of the tidal and river power system in order to mitigate flickers in different grid conditions. The BESS smooths the active power fluctuations and reduces flicker even from the weak grid with the low impedance angle in the distribution network. The feasibility of the proposed BESS system has been tested using a simplified simulation model with interconnected inverters developed in the validated simulation tool of PSCAD/EMTDC, and the obtained results from the case studies are presented.

16 TIDAL AND WAVE POWER↗

Dynamic hosting capacity analysis for distributed photovoltaic resources—Framework and case study

Distributed photovoltaic systems can cause adverse distribution system impacts, including voltage violations at customer locations and thermal overload of lines, transformers, and other equipment resulting from high current. The installed capacity at which violations first occur and above which would require system upgrades is called the hosting capacity. Current static methods for determining hosting capacity tend to either consider infrequent worst-case snapshots in time and/or capture coarse time and spatial resolution. Because the duration of violations cannot be captured with these traditional methods, the metric thresholds used in these studies conservatively use the strictest constraints given in operating standards, even though both worse voltage performance and higher overloads may be temporarily acceptable. However, assessing the full details requires accurately capturing time-dependence, voltage-regulating equipment operations, and performance of advanced controls-based mitigation techniques. In this paper, we propose a dynamic distributed photovoltaic hosting capacity methodology to address these issues by conducting power flow analysis for a full year. A key contribution is the formulation of time aware metrics to take these annual results and identify the hosting capacity. Through a case study, we show that this approach can more fully capture grid impacts of distributed photovoltaic than traditional methods and the dynamic hosting capacity was 60%–200% higher than the static hosting capacity in this case study.

14 SOLAR ENERGY↗

Design considerations of series type hybrid circuit breaker (S‐HCB)

Abstract The series‐type direct current (DC) hybrid circuit breaker (S‐HCB) concept was previously reported to offer better performance than solid‐state circuit breakers (SSCB) and hybrid circuit breakers (HCB). S‐HCB offers low conduction power loss like an HCB and ‐scale interruption time, which is even faster than an SSCB. It uses a pulse transformer to isolate the lower‐voltage high‐inductance power electronic circuit from the high‐voltage, low‐inductance main power loop. This paper provides analysis of the impact of the S‐HCB circuit components on the overall system performance and a scalable S‐HCB design guide for different DC system voltage and current ratings. In addition, system energy flow analysis is performed in the time domain to provide an understanding of how energy is delivered, dissipated, and released throughout the entire fault interruption process. The S‐HCB prototype was experimentally tested at 3 kV/30 A and 6 kV/150A with the results showing the interruption of the low fault current of 30 A and the high fault current of 150 A within 8 and maintaining the fault current at a near zero value for 300 to enable an arcless opening of a series mechanical switch. The key design challenges of S‐HCB at high voltage and high current ratings were discussed and possible solutions to mitigate those challenges were introduced.

Alashi, Mahmoud↗

Additive manufacturing print-heads for exotic material applications

Described herein is an additive manufacturing apparatus that is well-suited for constructing piezoelectric sensors. The additive manufacturing apparatus includes an extrusion nozzle formed of a conductive material such as aluminum. The extrusion nozzle has a channel by way of which printing material exits the extrusion nozzle, wherein a build plate is configured to receive the printing material responsive to the printing material exiting the extrusion nozzle. An arc suppressor formed of a semiconductor is coupled to the extrusion nozzle and is configured to dissipate excess charge that would otherwise exist on the extrusion nozzle when a relatively high bias voltage is applied to the extrusion nozzle. Thus, the arc suppressor mitigates arcing between the extrusion nozzle and the build plate. Arc suppressing gas is also optionally introduced into a printing region, thereby further mitigating arcing between the extrusion nozzle and the build plate.

Washburn, Cody M.↗

Structure and Voltage Recovery Driven by Defects Elimination in Li-Rich Layered Oxide Cathode Materials

Lithium-ion batteries (LIBs) are ubiquitous in a wide range of technologies, including cell phones, electric vehicles, and energy grid, and are indispensable in the transition toward sustainable energy technology. The battery performance is inherently connected to the capability of lithium ions to reversibly intercalate with the electrodes. The capacity of classical layered transition metal (TM) oxides, the primary commercial cathode materials, is limited to cationic redox activity. Anionic redox has thus emerged as a new paradigm for designing novel cathodes for next generation LIBs. It is recently confirmed oxygen redox in lithium-rich layered oxides (LRLO) with composition xLi 2 MnO 3 ∙(1-x)LiTMO 2 , which enables this group of materials exhibit reversible capacities exceeding 280 mAh g -1 . Unfortunately, this material undergoes voltage fading and instability that is rooted in irreversible structural transformation in terms of defects formation including lithium and oxygen vacancies, lithium tetrahedron, TM migration, edge dislocations, stacking fault, and local strain. Modification methods including morphology control, composition gradient, surface treatment, foreign elements doping, etc., have been proposed in the literatures to mitigate the defects formation and maintain the structure reversibility. Despite their improvement, the intrinsic voltage fading is still inevitable and remains a challenge that will require considerable effort to overcome. In this work, we demonstrate a path to recover the layer structure and working voltage through high-temperature annealing. The treatment at high temperature recovers the local Li-excess environments around oxygen, oxygen stacking sequence, and eliminates microstrain associated with different defects. As a result, the voltage profile once more shows plateau region during charge and the average discharge voltage is restored of the cycled cathode after heat treatment. Both theoretical calculations and experimental characterizations illustrate the mechanisms underlying the heating induced recovery. The structure metastability and defects removal are decisive in structure and voltage recovery of LRLO cathode material.

Zhang, Minghao↗

Influence of Tailored Applied Magnetic Fields on High-Power MPD Thruster Current Transport and Onset-Related Phenomena

This work investigated the effects of tailored, externally-applied magnetic fields on current transport and near-anode processes in the plasma discharge of a magnetoplasmadynamic thruster (MPDT). Electrical and plasma diagnostics were used to investigate how localized applied magnetic fields could mitigate the effects of the "onset" phenomena, including large-amplitude terminal voltage fluctuations and high anode fall voltages associated with unstable operation and anode erosion. An MPDT with a multi-channel hollow cathode was developed and tested with quasi-steady pulses of 1 millisecond duration at power levels of 36 kilowatts (20 volts, 1800 amperes) to 3.3 milliwatts (255 volts, 13.1 kiloamperes) with argon propellant in three different magnetic configurations: self-field, applied B field tangential to the anode lip near the exit plane, and applied cusp B field. The current pattern and current densities redistributed to follow the applied poloidal magnetic field lines, which created increased conduction paths to the anode. Also, the anode fall voltage was substantially reduced with both applied B field topologies over a large range of currents. For example, at 10.7 kiloamperes, the cusp applied magnetic field decreased anode fall voltages from 45-83 volts down to 15 volts or lower along much of the anode. The amplitude and frequency of the voltage fluctuations were also reduced over a broad range of currents with the applied fields. E.g., the standard deviations of the fluctuations were lowered by 37-49 percent at 8-9 kiloamperes. In addition, decreases in the mean terminal voltages as large as 31 percent were measured with the applied magnetic fields. These effects are shown to be associated with the increased current conduction along the applied magnetic field lines in the near-anode region. These results also suggest a reduction in frequency and intensity of current-concentrating filaments and anode spots, which contribute to erosion. Overall, both applied magnetic field configurations enabled significant reductions in onset-related behaviors relative to self-field operation. These improvements should lead to reduced anode erosion, i.e., improved thruster lifetime, and increased thruster efficiency with the applied fields. The applied fields used in this study differ from both the topologies and relative field strengths typically used in the vast majority of conventional, so-called "applied-field MPD thrusters" (AF-MPDTs). These results suggest a distinctive and more effective approach to influencing the near-anode phenomena and mitigating the deleterious effects of onset with appropriately designed applied magnetic fields.

delta-V↗

Characterization of carrier behavior in photonically excited 6H silicon carbide exhibiting fast, high voltage, bulk transconductance properties

Abstract Unabated, worldwide trends in CO 2 production project growth to > 43-BMT per year over the next two decades. Efficient power electronics are crucial to fully realizing the CO 2 mitigating benefits of a worldwide smart grid (~ 18% reduction for the United States alone). Even state-of-the-art SiC high voltage junction devices are inefficient because of slow transition times (~ 0.5-μs) and limited switching rates at high voltage (~ 20-kHz at ≥ 15-kV) resulting from the intrinsically limited charge carrier drift speed (< 2 × 10 7 -cm-s −1 ). Slow transition times and limited switch rates waste energy through transition loss and hysteresis loss in external magnetic components. Bulk conduction devices, where carriers are generated and controlled nearly simultaneously throughout the device volume, minimize this loss. Such devices are possible using below bandgap excitation of semi-insulating (SI) SiC single crystals. We explored carrier dynamics with a 75-fs single wavelength pump/supercontinuum probe and a modified transient spectroscopy technique and also demonstrated a new class of efficient, high-speed, high-gain, bi-directional, optically-controlled transistor-like power device. At a performance level six times that of existing devices, for the first time we demonstrated prototype operation at multi-10s of kW and 20-kV, 125-kHz in a bulk conduction transistor-like device using direct photon-carrier excitation with below bandgap light.

36 MATERIALS SCIENCE↗

Design of High-Voltage Stable Hybrid Electrolyte with an Ultrahigh Li Transference Number

Considering the high energy consumption during processing, and the low compliance and adhesion of ceramic electrolytes, the integration of polymer into ceramic electrolytes provides a way to mitigate the interfacial issues. However, the severe ion concentration gradient, low ionic conductivity, and instability toward Li metal and high-voltage cathodes become the major concerns in applying hybrid electrolytes. In this work, we report a single-ionconducting hybrid electrolyte (SIE-LLZO) with 64 wt % Li 7 La 3 Zr 2 O 12 (LLZO) particles embedded in a fluoroboron-centered Li-conductive polymer framework (LiBFSIE). The SIE-LLZO electrolyte exhibited a high Li transference number of 0.94 and electrochemical stability up to 5.6 V vs Li/Li + . Promising averaged Coulombic efficiencies of 99.97% and 99.91% were achieved in cells with LiNi 0.8 Co 0.15 Al 0.05 O 2 and LiNi 0.6 Mn 0.2 Co 0.2 O2 cathodes for 400 and 200 cycles, respectively. Finally, the Li-conducting pathway in the hybrid electrolyte was further investigated by a 6 Li-to- 7 Li isotope replacement method, indicating that Li transport mainly relies on the LLZO and interface between LiBFSIE and LLZO.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Model-Based Integrated High Penetration Renewables Planning and Control Analysis

Increasing adoption of Solar Photovoltaic (PV) generation at the distribution level poses several changes for the reliable operation of electrical power distribution systems. The addition of a significant amount of PV to a distribution network can introduce a variety of operational problems, including steady-state overvoltages, reverse flows, voltage flicker and excessive controller movement among others. These adverse impacts can be mitigated through a variety of equipment upgrades which represent a cost to either the electric utility or the owner of the PV site. The study performed here aims to quantify the levels of PV generation which present operational problems on a distribution circuit and how those problems might be alleviated. The study performed here included 20 distribution feeders selected from Pepco Holdings, Inc. (PHI) service territory. These feeders are located in the states of Delaware, Maryland and New Jersey. A hosting capacity study was performed on each feeder to determine how much additional PV it could support in its current configuration. Several improvements were then performed on these circuits including phase balancing, capacitor redesign, reducing the voltage regulator set points, fixed power factor operation on the PV inverters and the installation of battery storage. After each of these improvements the hosting capacity of the circuit was reevaluated in order to determine how that particular improvement impacted the amount of PV that could be hosted by the circuit. Each of these improvements represents a real cost in terms of labor and equipment in order to be implemented. They are expected to provide a benefit in terms of the amount of additional PV generation which can be safely interconnected to the distribution feeder. A cost benefit analysis was performed in order to evaluate the expected costs of each feeder improvement and how each one was able to increase the PV hosting capacity of each feeder. It is hoped that these results can be utilized by other distribution utilities in order to understand how they can improve the hosting capacity of their feeders and facilitate the deployment of more PV generation at the distribution level. Admittedly other utility companies will most likely have different feeder architectures and differing labor and equipment costs so the realized cost benefit numbers may be significantly different.

14 SOLAR ENERGY↗

Nanoscale Protection Layers To Mitigate Degradation in High-Energy Electrochemical Energy Storage Systems

In the pursuit of energy storage devices with higher energy and power, new ion storage materials and high-voltage battery chemistries are of paramount importance. Yet, they invite—and often enhance—degradation mechanisms, which are reflected in capacity loss with charge/discharge cycling and sometimes in safety problems. Degradation mechanisms are often driven by fundamentals such as chemical and electrochemical reactions at electrode–electrolyte interfaces, volume expansion and stress associated with ion insertion and extraction, and profound inhomogeneity of electrochemical behavior. Although it is important to identify and understand these mechanisms at some reasonable level, it is even more critical to design strategies to mitigate these degradation pathways and to develop means to implement and validate the strategies. A growing set of research highlights the mitigation benefits achievable by forming thin protection layers (PLs) intentionally created as artificial interphase regions at the electrode–electrolyte interface. These advances highlight a promising—perhaps even generic—pathway for enabling higher-energy and higher-voltage battery configurations. In this Account, we summarize examples of such PLs that serve as mitigation strategies to avoid degradation in lithium metal anodes, conversion-type electrode materials, and alloy-type electrodes. Examples are chosen from a larger body of electrochemical degradation research carried out in Nanostructures for Electrical Energy Storage (NEES), our DOE Energy Frontier Research Center. Overall, we argue on the basis of experimental and theoretical evidence that PLs effectively stabilize the electrochemical interfaces to prevent parasitic chemical and electrochemical reactions and mitigate the structural, mechanical, and compositional degradation of the electrode materials at the electrode–electrolyte interfaces. The evidenced improvement in performance metrics is accomplished by (1) establishing a homogeneous interface for ion insertion and extraction, (2) providing mechanical constraints to maintain structural integrity and robust electronic and ionic conduction pathways, and (3) introducing spatial confinements on the electrode material matrix to alter the phase transformation (delaying the occurrence of the conversion reaction) upon Li insertion, which results in superior electrode performance, excellent capacity retention, and improved reversibility. Taken together, these examples portray a valuable role for thin protection layers synthesized over electrode surfaces, both for their benefit to cycle stability and for revealing insights into degradation and mitigation mechanisms. Furthermore, they underscore the impact of complex electrochemical behavior at nanoscale materials and nanostructure interfaces in modulating the behavior of energy storage devices at the mesoscale and macroscale.

25 ENERGY STORAGE↗

Computational and experimental search for potential polyanionic K-ion cathode materials

Discovering high-energy cathode materials is critical to construct K-ion batteries for practical applications. Owing to the great success of layered oxides in Li- and Na-ion systems, K layered cathodes have also been investigated in recent years. However, the much larger size of K + compared to Li or Na introduces strong K + –K + interaction within the layer, which results in a sloped voltage profile thereby limiting the specific capacity and operating voltage. In contrast, polyanionic materials with a three-dimensional K + arrangement can effectively mitigate K + –K + interaction. In this work, ten K polyanionic compounds with theoretical capacity >100 mA h g –1 are screened from the Inorganic Crystal Structure Database as potential cathode materials for K-ion batteries. Among the ten proposed compounds, K 2 MnP 2 O 7 , K 2 Mn 2 P 2 O 7 F 2 , K 2 Fe 2 P 2 O 7 F 2 , and K 6 V 2 (PO 4 ) 4 with average voltage <4.5 V are synthesized and evaluated electrochemically. While the re-insertion of K into these compounds is not fully reversible, it may be related to the very high migration barrier that we compute for K ions. In addition, we show the successful synthesis of a series of K 3 V 3–x Cr x (PO 4 ) 4 (x = 0, 1, 2, 3) compounds. Among these, K 3 V 2 Cr(PO 4 ) 4 exhibits the largest reversible capacity, as revealed by the in situ investigation. Lastly, we find that the redox couples in many of these compounds sit at remarkably high potential, even higher than in equivalent Li compounds, which brings both opportunities and challenges in the future research of K polyanion cathodes.

25 ENERGY STORAGE↗

Membrane-Induced Vanadium Crossover-Blocking Polybenzimidazole Copolymer with Exceptional Proton Selectivity

Broad deployment of redox flow batteries is hindered, in part, due to the lack of highly selective ion-exchange membranes with high proton conductivity. We report a post-functionalization strategy for polybenzimidazole copolymer (PBI-co) membranes by a reacting mixture of concentrated sulfuric and phosphoric acids that led to improved membrane selectivity while retaining high proton conductivity. Fourier-transform infrared spectroscopy confirmed successful sulfonation and protonation of benzimidazole functionalities. PBI-co exhibits a very high room-temperature proton conductivity of 0.138 S cm -1 , as measured by electrochemical impedance spectroscopy. PBI-co also demonstrates electromigration crossover mitigation under applied current densities up to 500 mA cm -2 , and voltage pulses up to 1.4 V, while also inhibiting diffusion-driven vanadium crossover for over 20 days. Single-cell vanadium flow battery testing on post-functionalized PBI-co further confirms state-of-the-art battery performance with an ~99.5% Coulombic efficiency at 100 mA cm -2 and an area-specific resistance of ~20 mO cm 2 lower than Nafion-212 membrane.

25 ENERGY STORAGE↗

Online Monitoring of Medium Voltage Cable Systems with Spread Spectrum Time Domain and Frequency Domain Reflectometry

In-service failures of wave energy convertor (WEC) cable systems can have a significant cost and power availability impact. Close parallel research 2019 data showed > 1B£ and 9 Terra-Watt-Hours associated with global off-shore wind (OSW) cable failures (Strang-Moran 2020). OSW is a closely related technology but currently is significantly cheaper than WEC technology. For wave energy to compete, the problem of reliable cable transmission must be mitigated. This project develops isolation technology to allow online high frequency reflectometry testing of medium voltage cables (1 to 10 kV and higher) without arcing or damage to the test instrument. Online spread spectrum time domain reflectometry (SSTDR) testing has been established for low voltage cable systems in the aircraft and rail industry and the ability to detect and locate cable flaws of interest is well understood. Extending reflectometry testing to medium voltage systems could enable detection of cable damage before failures occur thereby allowing repair and replacement of damaged cable segments to be scheduled and managed. The seedling project succeeded to pass and receive high frequency SSTDR signals onto a cable up to 1 kV using a parallel trace isolation circuit board that can be connected onto the test cable. The approach used a novel circuit design for which an invention disclosure has been filed. A proposed sapling project would extend the technology toward the higher operating voltages used by WEC systems, thereby enabling online SSTDR cable monitoring. The goal of the seedling project was to extend the capability of the ARENA cable/motor test bed to address medium voltages and to develop a high pass filter isolation architecture to protect the reflectometry instrument from the low frequency (DC – 60 Hz) line voltage while allowing the high frequency diagnostic signal to pass to and from the test instrument to the live line. Initial efforts focused on passive LCR filter circuits to reduce 60 Hz levels below 10 volts from a 10 kV line while allowing the MHz high frequency chirps to pass onto the cables and for mV signals to be detected. We discovered that the parasitic loss behavior of real high voltage components precluded this approach from working. An alternate approach was adapted for the electric field to couple between two parallel traces on a printed circuit board much like a radio-frequency coupler. The challenge here was and is to have the parallel traces close enough to each other to effectively pass the high frequency chirp onto the live line and receive any reflected signal from any encountered impedance change along the cable. This reflected signal will be in the mV range. The traces however must be far enough apart to not allow arcing on the board. A design with 3 mm spacing was determined to allow the high frequency signal to pass onto the live line and receive the mV signal back into the instrument while reducing the 60 Hz voltage amplitude by >80 dB (more than a factor of 10,000) without allowing arcing from across the parallel traces. This was confirmed by simulation and test.

16 TIDAL AND WAVE POWER↗

Stabilizing and understanding the interface between nickel-rich cathode and PEO-based electrolyte by lithium niobium oxide coating for high-performance all-solid-state batteries

The pursuit of high energy density and safe lithium ion batteries (LIBs) is the urgent goal for the development of next-generation electric vehicles (EVs). All-solid-state batteries (ASSBs) with the combination of poly(ethylene oxide) (PEO)-based solid polymer electrolyte (SPE) and Ni-rich lithium nickel manganese cobalt oxide LiNi0.8Mn0.1Co0.1O2 (NMC811) cathode are promising candidates for EVs due to their improved energy density and safety. However, the low electrochemical oxidation window of PEO-based SPE and the instability of NMC811 at the charge/discharge process seriously restrict the battery performance. Herein, a high voltage stable solid-state electrolyte layer lithium niobium oxide (LNO) is coated on the NMC811 electrode surface by atomic layer deposition for stabilizing NMC811-PEO solid polymer batteries. Electrochemical tests show that LNO coating can stabilize the NMC811 active materials and mitigate the decomposition of SPE upon the cycling process, rendering a good performance of NMC811-PEO solid polymer battery. Mechanism studies by SEM, STEM, XAS, and XPS disclose that the uncoated NMC811 suffers from chemomechanical degradations along with oxygen release triggering the decomposition of SPE, which results in unstable cathodic electrolyte interphase. With LNO coating, chemomechanical degradations and oxygen release are inhibited and the decomposition of SPE is mitigated. This paper renders a stable and high-performance high-energy-density SSB for high voltage application, which paves the way toward next-generation solid-state LIBs.

25 ENERGY STORAGE↗

Runaway electrons and magnetic island confinement

The breakup of magnetic surfaces is a central feature of ITER planning for the avoidance of damage due to runaway electrons. Rapid thermal quenches, which lead to large accelerating voltages, are thought to be due to magnetic surface breakup. Impurity injection to avoid and to mitigate both halo and runaway electron currents utilizes massive gas injection or shattered pellets. The actual deposition is away from the plasma center, and the breakup of magnetic surfaces is thought to spread the effects of the impurities across the plasma cross section. The breakup of magnetic surfaces would prevent runaway electrons from reaching relativistic energies were it not for the persistence of non-intercepting flux tubes. These are tubes of magnetic field lines that do not intercept the walls. In simulations and in magnetic field models, non-intercepting flux tubes are found to persist near the magnetic axis and in the cores of magnetic islands even when a large scale magnetic surface breakup occurs. As long as a few magnetic surfaces reform before all of the non-intercepting flux tubes dissipate, energetic electrons confined and accelerated in these flux tubes can serve as the seed electrons for a transfer of the overall plasma current from thermal to relativistic carriers. The acceleration of electrons is particularly strong because of the sudden changes in the poloidal flux that naturally occur in a rapid magnetic relaxation. Furthermore, the physics of magnetic islands as non-intercepting flux tubes is studied. Expressions are derived for (1) the size of islands required to confine energetic runaway electrons, (2) the accelerating electric field in an island, (3) the increase or reduction in the size of an island by the runaway electron current, (4) the approximate magnitude of the runaway current in an island, and (5) the time scale for the evolution of an island.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Attack-resilient algorithms and testbed federation for wide-area protection and control in smart grid

Today’s energy infrastructure is undergoing a massive transformation across all generation, transmission, and distribution systems to provide reliability, efficiency, and sustainability to the power system network. During the past 10 years, there has been a remarkable enhancement in developing close-loop wide-area protection and control (WAPAC) applications, such as automatic generation control (AGC), wide-area protection scheme (WAPS), synchrophasor-based wide-area voltage control system (WAVCS), etc., in the energy management system (EMS) to provide an adequate situational awareness to control center operators during physical disturbances and natural events. The rapid digitalization, unencrypted communication, and numerous data-sharing devices have increased digital access points that have exposed the grid network to countless cyberattacks pertinent to the WAPAC cybersecurity. Given the amount of complex grid network coupled with legacy infrastructures, it is untrustworthy to completely rely on information technology (IT)-based conventional security measures to defend against evolving cyberattacks. Hence, there is a compelling need to go beyond the traditional paradigm of ‘security by obscurity’ and ‘bolt-on’ security measures, and develop a suite of innovative security solutions at multiple layers to transform the current “fault-resilient” grid into “fault and attack-resilient” grid of the future. This dissertation specifically focuses on developing application-specific attack-resilient solutions for critical WAPAC applications in the smart grid. The first part of the study, Attack-Resilient Wide-Area Protection Scheme, presents a cyber-physical attack-resilient system (CPARS) for WAPS, where two anomaly detection methods are proposed to detect multi-level cyberattacks followed by the rules-based intrusion mitigation system (RIMS) to initiate effective mitigation strategies, tailored to these attacks, to restore the normal grid operation after disturbances. The first anomaly detection component, Machine learning-based Anomaly Detection for Centralized WAPS, discusses a novel architecture and methodology for developing a machine-learning-based anomaly detection system (ADS) for the centralized wide-area protection system (CWAPS) by applying the variational mode decomposition (VMD) technique and decision tree (DT) algorithms using cyber logs and synchrophasor measurements. The second component, Multi-Agent-based Anomaly Detection for Decentralized WAPS, presents a two-level hierarchical multi-agent-based decentralized WAPS against the system-aware stealthy cyber-attacks. Finally, for the RIMS, the state transition diagram-based mitigation measures are defined based on the grid operation states and experimental testing and evaluation are presented in a cyber-physical testbed environment. The second part of the study, Attack-Resilient Wide-Area Voltage Control System, addresses the existing vulnerabilities in the wide-area voltage control system (WAVCS), presents the methodology for performing an impact analysis during data integrity attacks, and proposes a data-driven attackresilient system (DARS) by incorporating machine learning-based ADS and rules-based anomaly mitigation system (RAMS) to detect these attacks and provide necessary mitigation actions to maintain the transient voltage stability after disturbances. Finally, the third part, Networked Federation Testbed (NEFTSec) for Smart Grid Cybersecurity, focuses on developing an interconnected federated testbed through a common network like the internet, describes its conceptual architectures, and also presents its design components for experimental testing, validation, and evaluation. Further, it presents the co-simulation interface algorithm (CIA) to facilitate the geographically-dispersed real-time distributed simulation (GD-RTDS) during the cyber-physical federation. In general, this dissertation presents innovative attack-resilient solutions for WAPAC applications that are experimentally tested and evaluated using the PowerCyber testbed and NEFTSec platform to accelerate the transition of state-of-the-art research works to the real-field deployments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Physics-Informed Graph Neural Networks for Collaborative Dynamic Reconfiguration and Voltage Regulation in Unbalanced Distribution Systems

Network reconfiguration has long been employed as a strategic approach to minimize power distribution system losses and effectively regulate voltage levels. Tap-changing voltage regulators are also critical for controlling bus voltages, especially in accommodating the increasing integration of distributed energy resources (DERs) with intermittent outputs. This paper introduces novel methodologies to address the challenges of dynamic reconfiguration and optimal tap setting in unbalanced three-phase distribution systems. We propose an approximated mixed-integer quadratically constrained program (MIQCP) to model dynamic reconfiguration, along with a pioneering formulation for voltage regulator (VR) tap-setting based on Special Ordered Set type 1 (SOS1). To mitigate computational complexity, we propose a physics-informed spatial-temporal graph convolutional network (STGCN) with an integrated link classifier. The proposed approach enables efficient solution generation by fixing specific variables in the MIQCP instance and solving the simplified sub-MIP using an MIP solver. Numerical studies demonstrate the superior prediction accuracy of our STGCN model compared to baseline neural network models, resulting in reduced DER curtailment and voltage deviation with shorter computation time.

dynamic reconfiguration↗

Enhancing the mass resolving power of FRIB’s proposed high-voltage MR-ToF mass separator and spectrometer: Addressing non-ideal conditions

Multi-reflection time-of-flight mass separators and spectrometers (MR-ToF MSs) are indispensable tools at radioactive ion beam (RIB) facilities. These electrostatic ion beam traps act as highly selective mass separators and high-precision mass spectrometers for rare and exotic nuclei. When well-tuned and designed to minimize higher-order flight-time aberrations, state-of-the-art MR-ToF MSs approach, and slightly exceed, mass resolving powers of m/Δm = 10 6 . Achieving m/Δm ≥ 3 ⋅ 10 6 would provide the ability to resolve > 90 % of all known isomeric states with half-lives above 10 ms. However, the ability to mass separate in all practical setups is limited by non-ideal conditions which place such resolving powers out of reach. Here, to this end, we present a simulated analysis of these conditions in the newly proposed high-voltage MR-ToF MS for the Facility for Rare Isotope Beams (FRIB). It is expected to store ions at 30 keV beam energy and increase ion throughput by two orders of magnitude compared to current devices. Existing efforts to mitigate the effects of non-ideal conditions employed for current MR-ToF devices storing ions at < 3 keV beam energy will already enable mass resolving powers approaching 10 6 for FRIB’s high-voltage MR-ToF device. Simulations of newly proposed mitigation strategies show that even mass resolving powers approaching 10 7 might become feasible.

Electrostatic ion beam traps↗