Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “voltage and current controllers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Magnetic electron collimation in three-dimensional semi-metals

While electrons moving perpendicular to a magnetic field are confined to cyclotron orbits, they can move freely parallel to the field. This simple fact leads to complex current flow in clean, low carrier density semi-metals, such as long-ranged current jets forming along the magnetic field when currents pass through point-like constrictions. Occurring accidentally at imperfect current injection contacts, the phenomenon of "current jetting" plagues the research of longitudinal magneto-resistance, which is particularly important in topological conductors. Here we demonstrate the controlled generation of tightly focused electron beams in a new class of micro-devices machined from crystals of the Dirac semi-metal Cd 3 As 2 . The current beams can be guided by tilting a magnetic field and their range tuned by the field strength. Finite element simulations quantitatively capture the voltage induced at faraway contacts when the beams are steered towards them, supporting the picture of controlled electron jets. These experiments demonstrate direct control over the highly non-local signal propagation unique to 3D semi-metals in the current jetting regime, and may lead to applications akin to electron optics in free space.

36 MATERIALS SCIENCE↗

Modeling and control of cascaded bridgeless multilevel rectifier under unbalanced load conditions

The goal of this project is to model and control a novel unidirectional cascaded multilevel bridgeless rectifier as an active front end in medium and high voltage applications. This topology has many advantages over a conventional cascaded H-bridge rectifier, such as lower implementation cost, higher reliability, and greater flexibility with similar power quality. The complete design process of the proposed converter is developed step by step in order to meet all the desired objectives. The steady-state mathematical model is used to develop a method for the voltage balancing of dc cells. Power factor analysis is discussed to mathematically derive requirements for the number of partially controlled and fully controlled H-bridges in the proposed H-bridge converter. Power loss, efficiency, and cost comparison studies between the traditional cascaded H-Bridge converter and the proposed bridgeless converter demonstrate the advantages. After exploring various well-established control methods, a novel control strategy is proposed to achieve dc voltage balancing, fast and robust grid synchronization, power factor correction, and elimination of zero crossing current distortion under both balanced and unbalanced load conditions. The converter can also be used for reactive power compensation in a grid tied power system if a sufficient number of fully controlled H-bridge modules are included. Processor-In-the-Loop (PIL) simulation has been the utilized to validate the performance of discrete control structure. Simulation and experimental results validate the models and control method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Inner-Loop Control Method for the Filter-less, Voltage Sensor-less, and PLL-less Grid-Following Inverter-Based Resource

This paper presents a novel inner-loop control method for the inverter-based resource (IBR). The innovative concepts include removing the voltage sensors at the point of common coupling (PCC), removing the inverter interface inductance, and removing the traditional phase-locked loop (PLL) circuits. Simulation is conducted to verify the feasibility of the method. Furthermore, the virtual impedance is applied to the control loop to improve the current THD and dynamics. Compared to the traditional control, the proposed one helps offload the system by reducing the bulky inductors and voltage sensors without compromising the control performance.

grid-forming inverter, inner-loop control, filterl↗

Research Roadmap on Grid-Forming Inverters

This research roadmap is intended to fill the knowledge gap by providing a system view of grid-forming inverter-based resource controls and their impact on grid stability, which we believe is central to meeting some of the challenges to operating the future North American electric power system. This includes the roles and requirements of grid-forming inverter-based resources—including solar photovoltaics, wind generators, and energy storage. For this roadmap, we focus on a specific family of grid-forming inverter control approaches that do not rely on an external voltage source (i.e., no phase-locked loop) and that can share load without explicit communications. Although the roadmap is focused narrowly on system challenges for grid-forming controls and power system stability, including interactions with protection, we hope it serves as a foundational element for future system-of-systems roadmapping needed in a broader grid modernization effort with increasing deployments of inverter-based resources. The roadmap first introduces formal definitions for the grid stability topics and then describes the differences between grid-forming and traditional grid-following control approaches for inverter-based resources. The core of the roadmap consists of a review of current research and an outline of research needs related to five grid-forming inverter topics: frequency control, voltage control, system protection, fault ride-through and voltage recovery, and modeling and simulation. The review both delineates contemporary advances and highlights open research questions that must be addressed to enable the widespread adoption of inverter-based resources across the grid. Feedback from industry on these research questions is incorporated, including discussions during the Workshop on Grid-forming Inverters for Low-inertia Power Systems. The workshop included industry presentations and discussion of ongoing research, technology gaps, and piloting needs. This roadmap concludes by offering a multiyear perspective on the gradual field validation of grid-forming inverters. This perspective recognizes that the scale and scope of the types of power systems that inverters will be called on to provide grid-forming services will and should begin modestly. Specifically, this roadmap recognizes that inverter controls today are predominantly grid-following and that future power systems will involve a mix of inverter-based resources with both grid-following and grid-forming control capabilities. Growth over time will depend on how well grid-forming inverters perform and what advantages they bring as penetration levels (instantaneous and average) of inverter-based resources increases. This recognition, in turn, establishes a natural sequence of priorities for the research questions that must be addressed. Following this multiyear perspective, the roadmap offers short descriptions of two specific near-term research priorities: the review of regulatory and technical standards and the development of advanced modeling techniques. These priorities are foundational. We recommend immediate pursuit of them in parallel with and in direct support of the research outlined by our multiyear perspective.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analog-to-digital converter based on voltage-controlled superconducting devices

The increasing demand for cryogenic electronics in superconducting and quantum computing systems calls for ultra-energy-efficient data conversion architectures that remain functional at deep cryogenic temperatures. Here, in this work, we present the first design of a voltage-controlled superconducting flash analog-to-digital converter (ADC) based on a voltage-controlled quantum-enhanced Josephson junction field-effect transistor (JJFET). Exploiting its strong gate tunability and transistor-like behavior, the JJFET offers a scalable alternative to conventional current-controlled superconducting devices while aligning naturally with CMOS-style design methodologies. Building on our previously developed Verilog-A compact model calibrated to experimental data, we design and simulate a three-bit JJFET-based flash ADC targeted for integration within cryogenic control and readout circuitry in quantum computing. The core comparator block is realized through careful bias current selection and augmented with a three-terminal nanocryotron to precisely define reference voltages. Cascaded JJFET comparators ensure robust voltage gain, cascadability, and logic-level restoration across stages. Simulation results demonstrate accurate quantization behavior with ultra-low power dissipation, underscoring the feasibility of voltage-driven superconducting mixed-signal circuits. This work establishes a critical step toward unifying superconducting logic and data conversion, paving the way for scalable cryogenic architectures in quantum–classical co-processors, low-power artificial intelligence accelerators, and next-generation energy-constrained computing platforms.

Analog-to-digital converter↗

Bus Design for the Poloidal Field Coils of the NSTX-Upgrade Fusion Device

The National Spherical Torus eXperiment (NSTX) has undergone a major upgrade to NSTX-U at Princeton Plasma Physics Laboratory (PPPL). NSTX upgrade (NSTX-U) will double the toroidal field, plasma current, and neutral beam injection heating power, as well as significantly increase the pulse duration. NSTX-U uses three poloidal field (PF) coils at the vessel top and three at the bottom near the divertor areas to control the local plasma shape there. These shaping coils operate at a maximum terminal voltage of 2 kV, corresponding to a maximum current about 20 kA. To supply the power to the PF coils, hard copper bus bars are typically used near the vacuum vessel, while water cooled flexible cables are used away from the vessel. The detailed design of the hard copper bus bars will be covered in this article. During operation, these hard bus bars are subject to high electromagnetic (EM) forces, thermal displacement loads, as well as plasma halo loads due to disruption. The EM, thermal, and structural analysis were performed, and the results revealed that, with the worst loads combined, the new design meets the NSTX-U thermal, structural, and fatigue cycle requirements. Finally, the manufacturing and installation process of the bus work will be discussed at the end of this article.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Decentralized Control of Cascaded H-Bridge Inverters for Medium-Voltage Grid Integration: Preprint

This paper introduces a fully decentralized control strategy that allows for individualized active and reactive power control of H-bridge inverters connected in series. After formulating a model of the system power flows, we outline a communications-free approach where each inverter can act on independent commands. Inverter-level feedback is accomplished locally via a measurement of current flowing through the stack. A key feature is the lack of any centralized control routines or phase-locked loop. In this framework, the reactive power control loops achieve voltage synchronization among the converters and the grid, and the active power control loops modulate the terminal voltage amplitudes that influence power delivery. Furthermore, pole placement via state feedback is used to ensure stability of voltage synchronization while also enabling tracking of bidirectional power commands. Simulations are presented to validate the proposed approach.

communication-free modular converter control↗

Improved Control Strategy of Grid-Forming Inverters for Fault Ride-Through in a Microgrid System: Preprint

This paper develops improved control strategy of GFM inverter with fault ride-through (FRT) capabilities to guarantee stable operation of microgrid under fault conditions especially islanded microgrid and asymmetrical faults. The proposed control strategy includes dual control of positive-sequence and negative-sequence control, and the adaptive virtual impedance (VI) control. Unlike the existing works, the proposed strategy only applies the VI control for the d-component of the positive-sequence control and leaves the q-component of positive-sequence control and dq-component of negative-sequence control zero, thus achieving the improved stability and balanced three-phase voltage under asymmetrical faults. The adaptive feature of the VI control guarantees the stability of the GFM inverter under severe faults which could cause saturated inner current loop and instability if the VI is not adaptive. Simulation results of a phase-to-phase-ground fault show that the proposed control strategy improves the stability of GFM and achieves the stable and balanced output voltages in islanded microgrid.

fault ride-through↗

Single-layered organic photovoltaics with double cascading charge transport pathways: 18% efficiencies

The chemical structure of donors and acceptors limit the power conversion efficiencies achievable with active layers of binary donor-acceptor mixtures. Here, using quaternary blends, double cascading energy level alignment in bulk heterojunction organic photovoltaic active layers are realized, enabling efficient carrier splitting and transport. Numerous avenues to optimize light absorption, carrier transport, and charge-transfer state energy levels are opened by the chemical constitution of the components. Record-breaking PCEs of 18.07% are achieved where, by electronic structure and morphology optimization, simultaneous improvements of the open-circuit voltage, short-circuit current and fill factor occur. The donor and acceptor chemical structures afford control over electronic structure and charge-transfer state energy levels, enabling manipulation of hole-transfer rates, carrier transport, and non-radiative recombination losses.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Triple Phase-Shift Optimization of SiC-based Dual-Active Bridge DC/AC Converter

This paper presents a loss-optimized Triple Phase-Shift (TPS) switching strategy for Dual-Active Bridge (DAB) based converters. The proposed strategy considers minimizing total converter loss with respect to minimizing device rms cur-rents, enabling Zero-Voltage Switching (ZVS) turn-on of devices and accurate control of device turn-off current. A model for switching currents is presented, followed by a loss model and optimization strategy. A 1.3kV/100kW prototype based on SiC MOSFETs was used in this work and experimental results up to 10kW show the proposed TPS strategy to be more efficient for operation.

Vetrivelan, Adithyan↗

Bioresorbable Primary Battery Anodes Built on Core–Double-Shell Zinc Microparticle Networks

Bioresorbable implantable electronics require power sources that are also bioresorbable with controllable electrical output and lifetime. In this paper, we report a bioresorbable zinc primary battery anode filament based on a zinc microparticle (MP) network coated with chitosan and Al 2 O 3 double shells. When discharged in 0.9% NaCl saline, a Zn MP filament with a 0.17 × 2 mm 2 cross-sectional area exhibited a stable voltage output of 0.55 V at a current of 0.01 mA. Covered by chitosan and Al 2 O 3 double shells, the zinc MP filament exhibited a directional dissolution behavior with a tunable lifetime approximately linear to its length. A stable 200 h discharging time was achieved with a 15 mm Zn MP filament. The maximum output power was found to be 12 μW at 0.03 mA for one filament. The linearity relationship between the current output and the filament cross-sectional area suggested a facile strategy to raise the power output at constant discharging voltage. The filaments could also be connected in series and in parallel to boost its overall voltage and current output, demonstrating their excellent integration capability. Furthermore, this work presents a promising pathway toward bioresorbable transient batteries with controllable lifetime and power output, demonstrating a great potential for powering transient implantable biomedical devices.

25 ENERGY STORAGE↗

Time Delay of Wide Area Damping Control in Urban Power Grid: Model-Based Analysis and Data-Driven Compensation

Due to the rapid development of economies, large urban cities consume an increasing amount of energy and have a higher requirement for power quality. Voltage source converter based high voltage direct current (VSC-HVDC) is a promising device to transmit clean power from remote regions to urban power systems, while also providing wide area damping control (WADC) for frequency stabilization. However, the time-delay naturally existing in the VSC-HVDC system may degrade the performance of WADC and even result in instability. To address this issue, this paper develops a time-delay correction control strategy for VSC-HVDC damping control in urban power grids. First, a small signal model of WADC is built to analyze the negative impacts of time delay. Then, a data-driven approach is proposed to compensate for the inherent time delay in VSC-HVDC damping control. The extensive training data will be generated under various disturbances. After offline training, the long short-term memory network (LSTM) can be implemented online to predict the actual frequency deviation based on real-time measurements. Finally, the proposed method is validated through MATLAB-Simulink in a two-area four-machine system. The results indicate that the data-driven compensation has a strong generalization ability for random delay time constants and can improve the performance of WADC significantly.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Mitigation of Motor Stalling and FIDVR via Energy Storage Systems with Temporal Logic Specifications

The fault-induced delayed voltage recovery (FIDVR) phenomenon has been very common from the distribution system through the transmission system. It causes a delay on recovering significantly depressed local voltage after the fault is cleared, and it can also lead to more widespread cascading system failures. Mitigating this event with current control approaches is challenging and becoming a crucial issue. Here, a model predictive control-based strategy employing signal temporal logic specifications is proposed to help mitigate FIDVR. To this end, it investigates and extends a dynamic performance model allowing analytic insights into the system-wide impact of motor stalling and FIDVR. The proposed controller provides richer descriptions of voltage specifications addressing both magnitude and time simultaneously. We consider different control specifications with reactive power support from energy storage systems to prevent the voltage during/after the fault from dropping too low, and reduce the delay time of voltage recovery. The simulation results conducted with the IEEE 57 bus test network validate the proposed method and demonstrate the effectiveness of the mitigation strategy on FIDVR.

25 ENERGY STORAGE↗

Provably-Stable Overload Ride-Through Control for Grid-Forming Inverters Using System-Wide Lyapunov Function Analysis

A key challenge associated with a grid-forming (GFM) inverter based resource (IBR) is its behavior during severe grid disturbances: since a GFM inverter regulates voltage in the fast timescale instead of current or power, it may experience a transient overload of current, power and/or energy during a severe grid disturbance. While many promising control strategies for overload ride-through have been proposed over the past two decades, transient stability of the system during and after the transition to an overload ride-through control mode remains difficult to guarantee. In this work, a novel overload ride-through control strategy is proposed for a system of grid-forming inverters that takes both self-protection and system-wide transient stability into account. A proposed system-level supervisory control uses slow communication to pre-emptively assign a set of local ride through control parameters to individual GFM IBR, including a current-limiting virtual reactance, that guarantees that synchronism is still preserved for any set of anticipated grid disturbances. At the core of the supervisory control lies a Lyapunov-function-based routine capable of establishing a strong, albeit conservative, transient stability guarantee for the system. Here, the proposed overload ride-through control strategy is validated via numerical integration of a reduced-order model, as well as through detailed electromagnetic transient (EMT) simulation.

30 DIRECT ENERGY CONVERSION↗

Converter-Interfaced CHP Plant for Improved Grid-Integration, Flexibility and Resiliency

GE Research and its partner GE Renewables have proposed the use of an interface converter solution to increase the penetration of small to medium-sized CHP (1MWe to 20MWe) into distribution grids and improve their flexibility and grid support capability. Indeed, the proposed interface converter solution thanks to presence of the grid-ready inverter, allows to streamline the compliance to grid codes requirements, reduce the interconnection delays and costs and ultimately one of the main barriers for CHP adoption by commercial and industrial facilities. An additional benefit provided by the interface converter is the use of the grid-ready inverter for reactive power which eliminates the need of sizing the generator for that capability. These two benefits highly favor the economic feasibility of converter-interfaced CHP. Five user cases, each in one of the leading U.S states for CHP potential reported by the DOE in its estimation of the U.S Technical Potential of CHP, were selected to compare the economic performances of converter-interfaced CHP as compared with directly-coupled. They include a college campus in California, a hospital in New York, a water reclamation plant in Texas, a hotel in Minnesota, and a large office building in Pennsylvania. Results showed that, the presence of the interface converter allows to increase the return on investment (ROI) by 0.5 to 2 percentage points in most of the cases (4 of 5). Indeed, the interface converter by shortening the interconnection process allows to accelerate revenues while reducing interconnection costs. Added to the reduced cost of the required generator these savings trade favorably the capital cost of the converter. The analysis also showed that the profitability of the converter-interfaced CHP is highly sensitive to the energy price, interconnection delay, and converter cost. However, it appears that if the interface converter can shorten the interconnection process by at least 6 months, adopting this solution will be more economically viable than directly-coupled configuration in almost all the +23,000 sites of the U.S Technical Potential CHP. The evaluation of the benefits of a converter-interfaced CHP also showed that it enables higher ROI when coupled with other distributed energy resources (DER) such as battery energy systems (BESS) or solar photovoltaic (PV). Indeed, in those scenario, the grid-ready inverter included in the interface converter eliminates the need of separate inverters if DC-coupling is used. On the technical performance, it has been verified that the presence of the interface converter allows to reduce by 70% to 80% the CHP short-circuit contribution to grid faults. This not only reduces the mechanical and thermal stresses exposed to the CHP electrical components but also increases the grid hosting capacity which ultimately enables higher penetrations CHP. Another key benefit of the interface converter validated with hardware-in-the-loop simulations and testing is its superior capability for reactive power support. Indeed, using a power hardware testbed with two +700kW inverters configured in back-to-back, a microgrid controller and actual facilities loads it was demonstrated that the presence of the interface converter can help maintain a power factor near ~1 or regulate the voltage to ~1.0pu at the point of common coupling. This benefit can be highly valuable if in the future, due to higher penetration of renewable distributed energy resources (DER), utilities start billing demand charge based on kVA instead of kW as currently. It was also validated that converter-interfaced CHP can dispatch heat and power commands and seamlessly switch between the two modes while consistently controlling the power factor or voltage at PCC. Indeed, the power hardware testing showed that grid-connected converter-interfaced CHP can follow either the power or heat demand while maintaining a unity power factor at converter output. This research proved that the adoption of an interface converter as the solution for interconnection of CHP system into the distribution grid can greatly improve the economic feasibility of small to medium-sized CHP as well as the plant power quality, flexibility and resiliency. Additionally, it allows increased penetrations of CHP into the distribution grid, extends their grid support capability, and facilitates the integration of BESS and PV DER by streamlining their collocation within the same facilities. This ultimately provides an opportunity for commercial and small industrial facilities in the U.S to accelerate their energy transition thanks to the high energy efficiency of CHP systems and its reliable, flexible, and resilient microgrid operation when interconnected with an interface converter.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distributed Online Voltage Control in Distribution Network: A Two-Stage Real-Time Implementation

The increasing integration of renewable-based distributed generation (DG) brings growing challenges to distribution network (DN) voltage control. To address this issue, a two-stage distributed online voltage control framework (TDO-VC) is proposed in this paper. In the proposed method, legacy voltage control devices are controlled in the upper stage on an hourly timescale, while DGs operate autonomously online in the lower stage to remove instantaneous voltage violations. The idea of receding horizon control is applied in the upper stage to comprehensively consider the current and future renewable generation, and the generalized fast dual ascent (Gf-DA) is employed in the lower stage to effectively manage DGs through near real-time optimization. The effectiveness of the proposed TDO-VC is demonstrated by rigorous theoretical analysis and case studies on IEEE-123 bus system.

Distributed generation↗

Voltage-controlled spin–orbit torque switching in W/CoFeB/MgO

Voltage control of magnetism and spintronics have been highly desirable but rarely realized. In this work, we show voltage-controlled spin–orbit torque (SOT) switching in W/CoFeB/MgO films with perpendicular magnetic anisotropy (PMA) with voltage administered through SrTiO 3 with a high dielectric constant. We show that a DC voltage can significantly lower PMA by 45%, reduce switching current by 23%, and increase the damping-like torque as revealed by the first- and second-harmonic measurements. These are characteristics that are prerequisites for voltage-controlled and voltage-select SOT switching spintronic devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hardware-In-the-Loop Benchmarking Setup for Phasor Based Control Validation

Phasor Based Control is a novel approach to controlling Distributed Energy Resources that aims at relieving various constraints that arise in the distribution grid. It is a two-layer control system with a supervisory control that coordinates distributed controllers to reach voltage phasor targets. The distributed controllers use local synchrophasor measurements and operate as feedback controllers. This control method is currently under development with several algorithms being under consideration for both the central and distributed components. In this report, we present the experimental setup that was prepared to prototype a hardware implementation and validate the control method in Hardware-In-the-Loop.

24 POWER TRANSMISSION AND DISTRIBUTION↗