Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “vacuum stability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Performance evaluation of the Russian SPT-100 thruster at NASA LeRC

Performance measurements of a Russian flight-model SPT-100 thruster were obtained as part of a comprehensive program to evaluate engineering issues pertinent to integration with Western spacecraft. Power processing was provided by a US Government developed laboratory power conditioner. When received the thruster had been subjected to only a few hours of acceptance testing by the manufacturer. Accumulated operating time during this study totalled 148 h and included operation of both cathodes. Cathode flow fraction was controlled both manually and using the flow splitter contained within the supplied xenon flow controller. Data were obtained at current levels ranging from 3 A to 5 A and thruster voltages ranging from 200 V to 300 V. Testing centered on the design power of 1.35 kW with a discharge current of 4.5 A. The effects of facility pressure on thruster operation were examined by varying the pressure via injection of xenon into the vacuum chamber. The facility pressure had a significant effect on thruster performance and stability at the conditions tested. Periods of current instabilities were noted throughout the testing period and became more frequent as testing progressed. Performance during periods of stability agreed with previous data obtained in Russian laboratories.

Sankovic, John M.↗

A Boresight Adjusment Mechanism For Use in Laser Altimeters

This paper describes the development of the Boresight Adjustment Mechanism (BAM) for the Geoscience Laser Altimeter System (GLAS) Instrument. The BAM was developed late in the integration and test phase of the GLAS instrument flight program. Thermal vacuum tests of the GLAS instrument indicated that the instrument-boresight alignment stability over temperature may be marginal. To reduce the risk that GLAS may not be able to meet the boresight alignment requirements an intensive effort was started to develop a BAM. Observatory-level testing and further evaluation of the boresight alignment data indicated that sufficient margin could be obtained utilizing existing instrument resources and therefore the BAM was never integrated onto the GLAS Instrument. However, the BAM was designed fabricated and fully qualified over a 4 month timeframe to be capable of precisely steering (less than 2 arcsec over plus or minus 300 arcsec) the output of three independent lasers to ensure the alignment between the transmit and receive paths of the GLAS instrument. The short timeline for the development of the mechanism resulted in several interesting design solutions. This paper discusses the requirement definition design, and testing processes of the BAM development effort how the design was affected by the extremely tight development schedule and the lessons learned throughout the process.

Hakun, Claef↗

Thermal balance testing of the Anik-E spacecraft

Spar Aerospace, Ltd. of Canada has recently completed the first of two infrared thermal balance/thermal vacuum tests on Canada's next generation of telecommunication satellites: Anik-E. Anik-E is a two spacecraft program using a three axis stabilized GE 5000 series bus as the vehicle for its payload. The infrared test setup consists of the mechanical hardware required to support the spacecraft within the thermal vacuum chamber and the infrared rig which supports the spacecraft. Spar developed a software package which calculated the lamp positions to provide the necessary uniform heat flux, based on the required heat inputs on the various isothermal zones of the spacecraft for the different phases of the tests. Infrared heat sensors, radiometers, were installed on the spacecraft surfaces. These were connected to the facility data processing system and continually monitored the flux absorbed by the various spacecraft surfaces. The test set up had distinct advantages. It enabled testing to progress directly from the thermal balance to thermal vacuum. Waveguide runs were installed for the communications portion of the testing prior to pumpdown. This precluded the requirement to return to ambient to reconfigure the setup.

Golob, Alex↗

Stability of bulk Ba2YCu3O(7-x) in a variety of environments

Small bars of ceramic Ba2YCu3O(7-x) were fabricated and subjected to environments similar to those that might be encountered during some NASA missions. These conditions include ambient conditions, high humidity, vacuum, and high fluences of electrons and protrons. The normal state resistivity or critical current density (J sub c) were monitored during these tests to assess the stability of the material. When normal state resistivity is used as a criterion, the ambient stability of these samples was relatively good, exhibiting only a 2 percent degradation over a 3 month period. The humidity stability was shown to be very poor, and to be a steep function of temperature. Samples stored at 50 C for 40 min increased in normal state resistivity by four orders of magnitude. Kinetic analysis indicates that the degradation reaction is second order with water vapor concentration. It is suspected that humidity degradation also accounts for the ambient instability. The samples were stable to vacuum over a period of at least 3 months. Degradation of J sub c in a 1 MeV electron fluence of 9.7 x 10 to the 14th e(-)/sq cm was determined to be no more than about 2 percent. Degradation of J sub c in a 8.7 x 10 to the 14th p(+)/sq cm of 42 MeV protons was found to be grain size dependent. Samples with smaller grain size and initial J sub c of about 240 A/sq cm showed no degradation. while that with larger grain size and an initial J sub c of about 30 A/sq cm degraded to 37 percent of its original value.

Gaier, James R.↗

ESR Dipole Power Supply Current Ripple and Noise Specifications

This note presents key findings for the ESR main magnet dipole power supplies (PS), where we find the current ripple specification to be close to or beyond the state-of-the-art. These specifications originate from beam-beam considerations, with the requirement to limit the ripple-induced hadron emittance growth to below 10%/hour. Beam dynamics that drive this PS ripple specification arise from the beam motions at the Interaction Point (IP). The frequency of the motions can be separated into "low", compared to the betatron frequency, and "high", i.e. around the betatron frequency and harmonics. In terms of the driving frequency, "low" implies ƒ<<ƒ 0 v x,y and "fast" means ƒ≈{ƒ 0 v x,y , ƒ 0 (1- v x,y , etc.}, where ƒ 0 =1/ T 0 =78.2 kHz is the revolution frequency, and v x,y are the fractional parts of the betatron tunes. Frequencies higher than ƒ 0 /2 will be folded back due to the particles sampling the field once per turn. To provide flexibility for future lattice adjustments and working point variations, we do not consider the tunes as fixed. Instead, we assume a certain margin and allow them to potentially fall within the range of 0.1< v x,y <0.5. In other words, the high-frequency region spans approximately from 8kHz to 40 kHz. Consequently,, we definte the dipole PS ripple in two distinct frequency ranges: the low-frequency range of [1-8000] Hz and the high-frequency range of [8-40] kHz. For the physics effects we analyzed in this note, there is no distinction between the ripple (which can be approximately reproduced in the frequency domain) and the random noise if both have some power within the frequency bandwidth of interest. Therefore, while we will use the term "ripple" for short, it should always be understood that we are referring to "ripple plus noise." Except for the lower end of the low-frequency range, the impact of the rippling PS current on the beam will be considerably reduced due to the eddy currents induced in the walls of the vacuum chamber. We will account for this effect in the PS ripple specifications to follow. The remaining sections of this note are structure as follows: Section II outlines the beam-beam physics requirements for the positional stability of the beam at the IP. Section III describes the anticipated shielding effect of the eddy currents induced in the vacuum chamber. Section IV derives the ripple requirement for the low-frequency range by propagating the closed orbit ripple resulting from the rippling dipoles to the IP (relevant lattice simulation results are summarized in the Appendix). In Section V, we present the analytical criterion for the ripple in the high-frequency range by considering resonant oscillations of the electron beam around a stable closed orbit near the betatron frequency. Finally, Section VI provides a summary of our findings and discusses related work.

43 PARTICLE ACCELERATORS↗

MXene-Derived Potassium-Preintercalated Bilayered Vanadium Oxide Nanostructures for Cathodes in Nonaqueous K-Ion Batteries

Bilayered vanadium oxides (BVOs) are promising cathode materials for beyond-Li-ion batteries due to their tunable chemistries and high theoretical capacities. However, the large size of beyond-Li + ions limits electrochemical cycling and rate capability of BVO electrodes. Recent reports of MXene-derived BVOs with nanoscale flower-like morphology have shown improved electrochemical stability at high rates up to 5C in nonaqueous lithium-ion batteries. Here, we report how morphological stabilization can lead to improved rate capability in potassium-ion batteries (PIBs) through the synthesis and electrochemical characterization of MXene-derived K-preintercalated BVOs (MD-KVOs), which were derived from two V 2 CT x precursor materials prepared using two different etching protocols. We show that the etching conditions affect the surface chemistry of the MXene, which plays a role in the MXene-to-oxide transformation process. MXene derived from a milder etchant transformed into a nanoflower MD-KVO with two-dimensional (2D) nanosheet petals (KVO-DMAE) while a more aggressive etchant produced a MXene that transformed into a MD-KVO with one-dimensional (1D) nanorod morphology (KVO-CMAE). Electrochemical cycling of the produced MD-KVOs after drying at 200 °C under vacuum (KVO-DMAE-200 and KVO-CMAE-200) in PIBs showed that electrochemical stability of MD-KVO at high rates improved through the morphological stabilization of 2D particles combined with the control of interlayer water and K + ion content. Structure refinement of KVO-DMAE-200 further corroborates the behavior observed during K + ion cycling, connecting structural and compositional characteristics to the improved rate capability. This work demonstrates how proper synthetic methodology can cause downstream effects in the control of structure, chemical composition, and morphology of nanostructured layered oxide materials, which is necessary for development of future materials for beyond-Li-ion battery technologies.

25 ENERGY STORAGE↗

Moduli axions, stabilizing moduli, and the large field swampland conjecture in heterotic M-theory

We compute the F- and D-term potential energy for the dilaton, complex structure, and Kähler moduli of realistic vacua of heterotic M-theory compactified on Calabi-Yau threefolds where, for simplicity, we choose ℎ 1,1 = ℎ 2,1 = 1. However, the formalism is immediately applicable to the “universal” moduli of Calabi-Yau threefolds with ℎ 1,1 = ℎ 1,2 > 1 as well. The F-term potential is computed using the nonperturbative complex structure, gaugino condensate and “world sheet instanton” superpotentials in theories in which the hidden sector contains an anomalous U⁡(1) structure group. The Green-Schwarz anomaly cancellation induces inhomogeneous “axion” transformations for the imaginary components of the dilaton and Kähler modulus—which then produce a D-term potential. V D is a function of the real components of the dilaton and Kähler modulus (s and t) that is minimized and precisely vanishes along a unique line in the s–t plane. Excitations transverse to this line have a mass m anom which is an explicit function of t. The F-term potential energy is then evaluated along the V D = 0 line. For values of t small enough that m anom ≳ M U —where M U is the compactification scale—we plot V F for a realistic choice of coefficients as a function of the Pfaffian parameter p. We find values of p for which V F has a global minimum at negative or zero vacuum density or a metastable minimum with positive vacuum density. In all three cases, the s, t, and associated “axion” moduli are completely stabilized. Finally, we show that, for any of these vacua, the large t behavior of the potential energy satisfies the “large scalar field” Swampland conjecture.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

THIN FILM CDS FRONT WALL SOLAR CELLS

Economy and stability determined for a photovoltaic cell made from a film of cadmium sulfide vacuum-deposited onto a metal-foil substrate

THIN FILM↗

Development Study of Cartridge/Crucible Tube Materials

The limitations of traditional alloys and the desire for improved performance for components is driving the increased utilization of refractory metals in tile space industry. From advanced propulsion systems to high temperature furnace components for microgravity processing, refractory metals are being used for their high melting temperatures and inherent chemical stability. Techniques have been developed to produce near net shape refractory metal components utilizing vacuum plasma spraying. Material utilization is very high, and laborious machining can be avoided. As-spray formed components have been tested and found to perform adequately. However, increased mechanical and thermal properties are needed. To improve these properties, post processing thermal treatments such as hydrogen sintering and vacuum annealing have been performed. Components formed from alloys of tungsten, rhenium, tantalum, niobium, and molybdenum are discussed and a metallurgical analyses detailing the results are presented. A qualitative comparison of mechanical properties is also included.

McKechnie, Timothy N.↗

Scatterometer-Calibrated Stability Verification Method

The requirement for scatterometer-combined transmit-receive gain variation knowledge is typically addressed by sampling a portion of the transmit signal, attenuating it with a known-stable attenuation, and coupling it into the receiver chain. This way, the gain variations of the transmit and receive chains are represented by this loop-back calibration signal, and can be subtracted from the received remote radar echo. Certain challenges are presented by this process, such as transmit and receive components that are outside of this loop-back path and are not included in this calibration, as well as the impracticality for measuring the transmit and receive chains stability and post fabrication separately, without the resulting measurement errors from the test set up exceeding the requirement for the flight instrument. To cover the RF stability design challenge, the portions of the scatterometer that are not calibrated by the loop-back, (e.g., attenuators, switches, diplexers, couplers, and coaxial cables) are tightly thermally controlled, and have been characterized over temperature to contribute less than 0.05 dB of calibration error over worst-case thermal variation. To address the verification challenge, including the components that are not calibrated by the loop-back, a stable fiber optic delay line (FODL) was used to delay the transmitted pulse, and to route it into the receiver. In this way, the internal loopback signal amplitude variations can be compared to the full transmit/receive external path, while the flight hardware is in the worst-case thermal environment. The practical delay for implementing the FODL is 100 s. The scatterometer pulse width is 1 ms so a test mode was incorporated early in the design phase to scale the 1 ms pulse at 100-Hz pulse repetition interval (PRI), by a factor of 18, to be a 55 s pulse with 556 s PRI. This scaling maintains the duty cycle, thus maintaining a representative thermal state for the RF components. The FODL consists of an RF-modulated fiber-optic transmitter, 20 km SMF- 28 standard single-mode fiber, and a photodetector. Thermoelectric cooling and insulating packaging are used to achieve high thermal stability of the FODL components. The chassis was insulated with 1-in. (.2.5-cm) thermal isolation foam. Nylon rods support the Micarta plate, onto which are mounted four 5-km fiber spool boxes. A copper plate heat sink was mounted on top of the fiber boxes (with thermal grease layer) and screwed onto the thermoelectric cooler plate. Another thermal isolation layer in the middle separates the fiberoptics chamber from the RF electronics components, which are also mounted on a copper plate that is screwed onto another thermoelectric cooler. The scatterometer subsystem fs overall stability was successfully verified to be calibratable to within 0.1 dB error in thermal vacuum (TVAC) testing with the fiber-optic delay line, while the scatterometer temperature was ramped from 10 to 30 C, which is a much larger temperature range than the worst-case expected seasonal variations.

McWatters, Dalia A.↗

The Geostationary Fourier Transform Spectrometer

The Geostationary Fourier Transform Spectrometer (GeoFTS) is an imaging spectrometer designed for an earth science mission to measure key atmospheric trace gases and process tracers related to climate change and human activity. The GeoFTS instrument is a half meter cube size instrument designed to operate in geostationary orbit as a secondary "hosted" payload on a commercial geostationary satellite mission. The advantage of GEO is the ability to continuously stare at a region of the earth, enabling frequent sampling to capture the diurnal variability of biogenic fluxes and anthropogenic emissions from city to continental scales. The science goal is to obtain a process-based understanding of the carbon cycle from simultaneous high spatial resolution measurements of carbon dioxide (CO2), methane (CH4), carbon monoxide (CO), and chlorophyll fluorescence (CF) many times per day in the near infrared spectral region to capture their spatial and temporal variations on diurnal, synoptic, seasonal and interannual time scales. The GeoFTS instrument is based on a Michelson interferometer design with a number of advanced features incorporated. Two of the most important advanced features are the focal plane arrays and the optical path difference mechanism. A breadboard GeoFTS instrument has demonstrated functionality for simultaneous measurements in the visible and IR in the laboratory and subsequently in the field at the California Laboratory for Atmospheric Remote Sensing (CLARS) observatory on Mt. Wilson overlooking the Los Angeles basin. A GeoFTS engineering model instrument is being developed which will make simultaneous visible and IR measurements under space flight like environmental conditions (thermal-vacuum at 180 K). This will demonstrate critical instrument capabilities such as optical alignment stability, interferometer modulation efficiency, and high throughput FPA signal processing. This will reduce flight instrument development risk and show that the GeoFTS design is mature and flight ready.

Carbon exchanges↗

Calibration Issues and Operating System Requirements for Electron-Probe Microanalysis

Instrument purchase requirements and dialogue with manufacturers have established hardware parameters for alignment, stability, and reproducibility, which have helped improve the precision and accuracy of electron microprobe analysis (EPMA). The development of correction algorithms and the accurate solution to quantitative analysis problems requires the minimization of systematic errors and relies on internally consistent data sets. Improved hardware and computer systems have resulted in better automation of vacuum systems, stage and wavelength-dispersive spectrometer (WDS) mechanisms, and x-ray detector systems which have improved instrument stability and precision. Improved software now allows extended automated runs involving diverse setups and better integrates digital imaging and quantitative analysis. However, instrumental performance is not regularly maintained, as WDS are aligned and calibrated during installation but few laboratories appear to check and maintain this calibration. In particular, detector deadtime (DT) data is typically assumed rather than measured, due primarily to the difficulty and inconvenience of the measurement process. This is a source of fundamental systematic error in many microprobe laboratories and is unknown to the analyst, as the magnitude of DT correction is not listed in output by microprobe operating systems. The analyst must remain vigilant to deviations in instrumental alignment and calibration, and microprobe system software must conveniently verify the necessary parameters. Microanalysis of mission critical materials requires an ongoing demonstration of instrumental calibration. Possible approaches to improvements in instrument calibration, quality control, and accuracy will be discussed. Development of a set of core requirements based on discussions with users, researchers, and manufacturers can yield documents that improve and unify the methods by which instruments can be calibrated. These results can be used to continue improvements of EPMA.

Carpenter, P.↗

Assessment of Blocking Contacts in Suppressing Polarization Effects in CsPbBr 3 Perovskite Detectors

The CsPbBr 3 perovskite has garnered significant attention as a room-temperature semiconductor for hard radiation detection due to straightforward synthesis, scalable crystal growth, low cost, and excellent energy resolution. However, despite these advantages, at ambient temperature, CsPbBr 3 devices may experience performance deterioration and irreversible failure due to “polarization” induced by electromigration of ions to electrical connections on the device. In this study, we tested several contact materials and their optimization deposition techniques to assess the stability of high-performance CsPbBr 3 γ-ray detectors. Metals, with low work functions (Ti, In, Sn, Sb, Pb, Bi, Al, Au, and TiC) and high-work-function (Au or Pt) contacts, were used to form different Schottky junctions using vacuum thermal evaporation, electron-beam evaporation, and sputtering methods. These detectors were tested in intermittent and continuous modes to assess their stability. Among the tested detectors, the Bi/CLB/Pt electrode configuration demonstrated superior stability, operating effectively for 11 months under periodic testing and 16 days under continuous testing. In contrast, other configurations functioned only for a few months under intermittent conditions. Upon incorporating a ~40-nm-thick TiC passivation layer on the anode side (Bi/TiC/CLB/Pt), the CLB device operated continuously for 36 days without degradation. In many cases, the failure mode of the devices was due to the degradation of the anode. Here, the chemical changes in the fresh and deteriorated anodes were characterized using scanning electron microscopy and energydispersive X-ray spectroscopy

CsPbBr3 perovskite↗

Environmental stability of intercalated graphite fibers

Graphite fibers intercalated with bromine, iodine monochloride, ferric chloride, and cupric chloride were subjected to stability tests under four environments which are encountered by engineering materials in the aerospace industry: ambient laboratory conditions, as would be experienced during handling operations and terrestrial applications; high vacuum, as would be experienced in space applications; high humidity, as would be experienced in marine applications; and high temperature, as would be experienced in some processing steps and applications. Monitoring the resistance of the fibers at ambient laboratory conditions revealed that only the ferric chloride intercalated fibers were unstable, due to absorption of water from the air. All four types of intercalated fibers were unstable, due to absorption of water from the air. All four types of intercalated fibers were stable for long periods under high vacuum. Ferric chloride, cupric chloride, and iodine monochloride intercalated fibers were sensitive to high humidity conditions. All intercalated fibers began to degrade above 250 C. The order of their thermal stability, from lowest to highest, was cupric chloride, iodine monochloride, bromine, and ferric chloride. Of the four types of intercalated fibers tested, the bromine intercalated fibers appear to have the most potential for application, based on environmental stability.

Gaier, J. R.↗

Environmental stability of intercalated graphite fibers

Graphite fibers intercalated with bromine, iodine monochloride, ferric chloride, and cupric chloride were subjected to stability tests under four environments which are encountered by engineering materials in the aerospace industry: ambient laboratory conditions, as would be experienced during handling operations and terrestrial applications; high vacuum, as would be experienced in space applications; high humidity, as would be experienced in marine applications; and high temperature, as would be experienced in some processing steps and applications. Monitoring the resistance of the fibers at ambient laboratory conditions revealed that only the ferric chloride intercalated fibers were unstable, due to absorption of water from the air. All four types of intercalated fibers were unstable, due to absorption of water from the air. All four types of intercalated fibers were stable for long periods under high vacuum. Ferric chloride, cupric chloride, and iodine monochloride intercalated fibers were sensitive to high humidity conditions. All intercalated fibers began to degrade above 250 C. The order of their thermal stability, from lowest to highest, was cupric chloride, iodine monochloride, bromine, and ferric chloride. Of the four types of intercalated fibers tested, the bromine intercalated fibers appear to have the most potential for application, based on environmental stability.

Gaier, J. R.↗

Reliability Issues with Polymer and MnO2 Tantalum Capacitors for Space Applications

This presentation gives a comparative analysis of degradation processes, failure modes and mechanisms in MnO2 and polymer technology capacitors. Analyzed conditions include effects of vacuum and radiation, soldering (pop-corning), long-term storage, operation at high temperatures, stability at low and high temperatures, and anomalous transients. Screening and qualification procedures to assure space-grade quality of CPTCs are suggested.

capacitor↗

Thermal design and test results for SUNLITE ultra-stable reference cavity

SUNLITE (Stanford University-NASA Laser In-Space Technology Experiment) is a space-based experiment which uses a reference cavity to provide a stable frequency reference for a terahertz laser oscillator. Thermal stability of the cavity is a key factor in attaining a stable narrow-linewidth laser beam. The mount which is used to support and align the cavity will provide thermal isolation from the environment. The baseline requirement for thermal stability of the cavity is 0.025 C/min, but the design is directed toward achieving stability well beyond this requirement to improve the science data gained. A prototype of the cavity mount was fabricated and tested to characterize the thermal performance. The thermal vacuum test involved stable high-resolution temperature measurements and stable baseplate temperature control over long durations. Based on test data, the cavity mount design satisfies the severe requirement for the cavity thermal stability.

Amundsen, Ruth M.↗

Magic Numbers and Stabilities of Photoionized Water Clusters: Computational and Experimental Characterization of the Nanosolvated Hydronium Ion

The stability and distributions of small water clusters generated in a supersonic beam expansion are interrogated by tunable vacuum ultraviolet (VUV) radiation generated at a synchrotron. Time-of-flight mass spectrometry reveals enhanced population of various protonated water clusters (H + (H 2 O) $n$ ) based upon ionization energy and photoionization distance from source, suggesting there are "magic" numbers below the traditional $n$ = 21 that predominates in the literature. These intensity distributions suggest that VUV threshold photoionization (11.0-11.5 eV) of neutral water clusters close to the nozzle exit leads to a different nonequilibrium state compared to a skimmed molecular beam. This results in the appearance of a new magic number at 14. Metadynamics conformer searches coupled with modern density functional calculations are used to identify the global minimum energy structures of protonated water clusters between $n$ = 2 and 21, as well as the manifold of low-lying metastable minima. New lowest energy structures are reported for the cases of $n$ = 5, 6, 11, 12, 16, and 18, and special stability is identified by several measures. These theoretical results are in agreement with the experiments performed in this work in that $n$ = 14 is shown to exhibit additional stability, based on the computed second-order stabilization energy relative to most cluster sizes, though not to the extent of the well-known $n$ = 21 cluster. Other cluster sizes that show some additional energetic stability are $n$ = 7, 9, 12, 17, and 19. To gain insight into the balance between ion-water and water-water interactions as a function of the cluster size, an analysis of the effective two-body interactions (which sum exactly to the total interaction energy) was performed. In conclusion, this analysis reveals a crossover as a function of cluster size between a water-hydronium-dominated regime for small clusters and a water-water-dominated regime for larger clusters around $n$ = 17.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗