Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “tunable”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Widely tunable (PbSn)Te lasers using etched cavities for mass production

Lead salt diode lasers are being used increasingly as tunable sources of monochromatic infrared radiation in a variety of spectroscopic systems. These devices are particularly useful, both in the laboratory and in the field, because of their high spectral brightness (compared to thermal sources) and wide spectral coverage (compared to line-tunable gas lasers). While the primary commercial application of these lasers has been for ultrahigh resolution laboratory spectroscopy, there are numerous systems applications, including laser absorbtion pollution monitors and laser heterodyne radiometers, for which diode lasers have great potential utility. Problem areas related to the wider use of these components are identified. Among these are total tuning range, mode control, and high fabrication cost. A fabrication technique which specifically addresses the problems of tuning range and cost, and which also has potential application for mode control, is reported.

Miller, M. D.↗

DIAL with heterodyne detection including speckle noise: Aircraft/shuttle measurements of O3, H2O, and NH3 with pulsed tunable CO2lasers

A parametric analysis of DIAL sensitivity with heterodyne detection is presented and comparisons with direct detection are discussed. Examples are given for monitoring vertical distributions of O3, H2O, and NH3 using a ground-, aircraft-, or shuttle-based pulsed tunable CO2 laser DIAL system. Results indicate that maximum sensitivity at minimum laser energy per measurement requires multiple pulse operation with the energy per pulse selected so that the measured photon rate is approximately equal to the detector IF bandwidth. Measurement sensitivities can be maximized and interference effects minimized by fine adjustment of measurement frequencies using the tunability of high pressure lasers. The use of rare isotope lasers minimizes loss due to CO2 atmospheric absorption.

Brockman, P.↗

Noise effects in an optical heterodyne spectrometer using tunable diode lasers

A comparison of measured and predicted signal-to-noise ratio is made in an optical heterodyne spectrometer utilizing a tunable diode laser which exhibited excess noise. It is shown that good agreement between predicted and measured signal-to-noise ratios results if excess noise effects due to tunable diode lasers are included in the predictions. The methods used to quantify excess noise and to incorporate their effects into predictions of signal-to-noise ratio are discussed.

Katzberg, S. J.↗

Tunable far-infrared spectroscopy

Tunable, CW, far-infrared radiation has been generated by nonlinear mixing of radiation from two CO2 lasers in a metal-insulator-metal (MIM) diode. The FIR difference-frequency power radiated from the MIM diode antenna to a calibrated indium antimonide bolometer. Two-tenths of a microwatt of FIR power was generated by 250 mW from each of the CO2 lasers. The combination of lines from a waveguide CO2 laser, with its larger tuning range, with lines from CO2, N2O, and CO2 isotopic lasers promises complete coverage of the entire far-infrared band from 100 to 5000 GHz (3-200 per cm) with stepwise-tunable CW radiation. To demonstrate the usefulness of the technique, the J = 4-5 line of CO was observed at 567 GHz.

Evenson, K. M.↗

Tunable diode lasers for 3-30 micron infrared operation

The tunable diode laser is now widely used in high resolution infrared spectroscopy studies, taking into account laboratory and industrial applications. The present investigation is concerned with advances related to laser performance and reliability. The advances are the result of improvements in materials and device technologies. Reliability data for broad-area Pb(1-x)Sn(x)Se lasers are considered along with performance improvements in stripe-geometry lasers, laser performance at wavelengths above 25 microns, and laser performance at wavelengths below 4 microns. Attention is given to tunable Pb-salt infrared diode lasers, mesa-stripe geometry lasers of Pb(1-x)Sn(x)Se and PbS(1-x)Se(x), and long wavelength diode laser emission observed in both Pb(1-x)Sn(x)Te and Pb(1-x)Sn(x)Se.

Linden, K. J.↗

Programmable, secondary frequency standard based infrared synthesizer using tunable lead-salt diode lasers

Quantum phase noise limited Lorentzian power spectral densities were achieved with tunable lead-salt diode lasers. Linewidths as narrow as 22 kHz were observed. A truly programmable infrared synthesizer was produced by frequency-offset-locking the tunable diode lasers to the combination of a stable CO2 (or CO) reference laser and a programmable microwave frequency synthesizer. Absolute frequency accuracy and reproducibility of about + or - 30 kHz (0.000001 kaysers) relative to the primary Cs frequency standard may now be obtained with this technique.

Freed, C.↗

Tunable mode and line selection by injection in a TEA CO2 laser

Tunable mode selection by injection in pulsed CO2 lasers is examined, and both analytical and numerical models are used to compute the required injection power for a variety of experimental cases. These are treated in two categories: mode selection at a desired frequency displacement from the center frequency of a transition line in a dispersive cavity and mode (and line) selection at the center frequency of a selected transition line in a nondispersive cavity. The results point out the potential flexibility of pulsed injection in providing wavelength tunable high-energy single-frequency pulses.

Menzies, R. T.↗

Heterodyne applications of tunable semiconductor diode lasers

Infrared tunable diode lasers were developed in the 1960s and have been a valuable radiation source for high resolution laboratory and in situ spectroscopy. Use of Pb-salt Tunable Diode Lasers (TDL) in heterodyne applications impose stringent requirements on the TDL not normally required for laboratory spectroscopy. A review will be made of progress associated with TDLs in such heterodyne applications. Areas addressed will include such items as lifetime, operating temperature, and factors affecting excess noise. The review will emphasize the experience at Langley Research Center, but will include material from other users. The Langley information will include a description and current status of the Laser Heterodyne Spectrometer experiment and atmospheric solar absorption data obtained from a groundbased heterodyne system.

Sidney, B. D.↗

Generation of tunable laser sidebands in the far-infrared region

In recent years, several techniques have been developed for the generation of tunable coherent radiation at submillimeter and far-infrared (FIR) wavelengths. The harmonic generation of conventional microwave sources has made it possible to produce spectrometers capable of continuous operation to above 1000 GHz. However, the sensitivity of such instruments drops rapidly with frequency. For this reason, a great deal of attention is given to laser-based methods, which could cover the entire FIR region. Tunable FIR radiation (approximately 100 nW) has been produced by mixing FIR molecular lasers and conventional microwave sources in both open and closed mixer mounts. The present investigation is concerned with improvements in this approach. These improvements provide approximately thirty times more output power than previous results.

Farhoomand, J.↗

Measurements of (C-12)H4 nu-4 band halfwidths using a tunable diode laser system and a Fourier transform spectrometer

Air-broadened and N2-broadened halfwidths at room temperature for twenty-five transitions in the nu-4 fundamental band of (C-12)H4 have been determined from IR absorption spectra recorded with a tunable diode laser spectrometer. Two tunable diode lasers operating in the 1250-1380-kayser region were used to obtain these data. Air-broadened halfwidths for twenty of these lines were also determined from additional spectra recorded at 0.01-kayser resolution with the Fourier transform spectrometer in the McMath solar telescope complex on Kitt Peak. The air-broadened halfwidths obtained from these two techniques are very consistent with agreement better than 3 percent in most cases.

Devi, V. M.↗

Remote sensing with a tunable alexandrite laser transmitter

A high-resolution, tunable alexandrite laser system is described. Two alexandrite lasers are continuously tunable from 725-790 nm and have a bandwidth of 0.02/cm. The stability of the two lasers is evaluated. The line shape of the laser emission and spectral purity of the system were measured. The data reveal that the output consists of three axial modes with an overall width of 0.026/cm, and the spectral impurity of the alexandrite laser output is less than 0.01 percent. The ground-based lidar system is utilized for measuring atmospheric pressure profiles; the integrated absorption in the wings of lines in the O2 A band is studied to produce the profiles. An example of lidar-collected atmospheric pressure data is presented and compared with radiosonde data; only a 0.3 percent deviation between the data is observed.

Korb, C. L.↗

Sub-Doppler tunable far-infrared spectroscopy

The first experimental observations of sub-Doppler linewidths in a cell made using tunable far-infrared radiation are reported. A double-resonance scheme has been used, combining CO2-laser infrared radiation with tunable far-infrared radiation to observe a sub-Doppler line shape in an excited vibrational state of CH3OH.

Inguscio, M.↗

Guided transmission for 10 micron tunable lasers

Performance characteristics are reported for two types of IR tunable laser guided transmission, one of which incorporates a CO2 laser, metallic piping or fiber-optics, and a detector system, while the other employs a tunable diode laser, fiber-optics, and a detector system. While existing technology furnishes low loss, rugged, near-single mode piping, fiber-optics exhibits appreciably higher loss, and its multimode fibers are fragile and chemically unstable. Studies have accordingly concentrated on such relevant fiber parameters as loss, toxicity, hygroscopicity, refractive index, flexibility, and thermal behavior at low temperature.

Yu, C.↗

A new tunable solid-state laser

A tunable solid state laser system, chromium-activated forsterite (Cr3+: Mg2SiO4), which has the potential for tunability from 850-1400 nm, is introduced. The characteristics of the host crystal are examined. Laser experiments and measurements are presented, including the observation of pulsed laser action at room temperature. The possibilities of the system are also considered.

Gayen, S. K.↗

Coherent tunable far infrared radiation

Tunable, CW, FIR radiation has been generated by nonlinear mixing of radiation from two CO2 lasers in a metal-insulator-metal (MIM) diode. The FIR difference-frequency power was radiated from the MIM diode antenna to a calibrated InSb bolometer. FIR power of 200 nW was generated by 250 mW from each of the CO2 lasers. Using the combination of lines from a waveguide CO2 laser, with its larger tuning range, with lines from CO2, N2O, and CO2-isotope lasers promises complete coverage of the entire FIR band with stepwise-tunable CW radiation.

Jennings, D. A.↗

Computer Processing Of Tunable-Diode-Laser Spectra

Tunable-diode-laser spectrometer measuring transmission spectrum of gas operates under control of computer, which also processes measurement data. Measurements in three channels processed into spectra. Computer controls current supplied to tunable diode laser, stepping it through small increments of wavelength while processing spectral measurements at each step. Program includes library of routines for general manipulation and plotting of spectra, least-squares fitting of direct-transmission and harmonic-absorption spectra, and deconvolution for determination of laser linewidth and for removal of instrumental broadening of spectral lines.

May, Randy D.↗

Broadly tunable high-power operation of an all-solid-state titanium-doped sapphire laser system

Broadly tunable and high-power operation of a Ti-doped sapphire laser is obtained with a diode-laser-pumped frequency-doubled Nd:YAG laser as the pump source. A maximum broadband (FWHM = 25 nm) output pulse energy of 720 microJ at 795 nm in a TEM00 mode is obtained for 1850 microJ of energy of 532-nm pump light. A minimum pulse duration of 7 nsec is obtained from a 40-mm-long cavity. With the use of an intracavity prism, the Ti:sapphire laser is tunable continuously over the 696-1000-nm spectral range (with three different mirror sets).

Steele, T. R.↗

The Berkeley tunable far infrared laser spectrometers

A detailed description is presented for a tunable far infrared laser spectrometer based on frequency mixing of an optically pumped molecular gas laser with tunable microwave radiation in a Schottky point contact diode. The system has been operated on over 30 laser lines in the range 10-100/cm and exhibits a maximum absorption sensitivity near one part in a million. Each laser line can be tuned by + or - 110 GHz with first-order sidebands.

Blake, G. A.↗