Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “transient detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Cadmium Magnesium Telluride for Next-Generation X-Ray Free Electron Laser, Synchrotron, and Many Other Applications

We developed a picosecond photodetector based on our Bridgman-grown and specially engineered cadmium magnesium telluride (Cd 1–x MgxTe) single crystal that is sensitive to both optical and X-ray pulses for coarse timing in free-electron laser applications. Cd 1–x MgxTe is a widebandgap semiconductor with potential applications, not only in optoelectronics, but also in particle physics as an intense pulse radiation detector for bremsstrahlung, X-ray/gamma-ray radiation, thermal neutrons, and medical imaging. For femtosecond optical and X-ray crosscorrelation, the material must have a very short lifetime, a condition that is opposite to that required for nuclear spectroscopy applications. At the same time, the material also needs to have a very low bulk leakage current, in the 10–90 nA range for voltages to even 1000 V. Hence, the ability to tailor or engineer the material is very crucial. Picosecond response and the crystal growth of this specially engineered Cd 1–x MgxTe material are presented. Furthermore, other characterization and transient measurements are discussed along with room-temperature semiconductor detector performance for other nuclear radiation detection applications.

36 MATERIALS SCIENCE↗

Infrared thermography NDT for in-situ defect detection in sandwich composite panel manufacturing

Composite manufacturing presents numerous challenges, as defects can arise from various sources throughout the process. In sandwich composite structures, the integration of a foam core introduces additional complexity and increases the likelihood of defect formation like delamination. To mitigate these issues and reduce the risk of future structural failures, in-situ monitoring during manufacturing is essential. This study investigates infrared (IR) thermography as a non-destructive technique for detecting manufacturing defects in foam-core sandwich composite panels under thermally excited conditions representative of in-situ processing. A stationary FLIR A8590 IR camera (640 × 512 pixels, 30Hz, 17mm lens, 9 ft stand-off distance) was used to monitor prefabricated panels subjected to controlled external heating simulating compression molding and resin cure exotherm. Interlaminar delamination defects with characteristic sizes ranging from 0.25 × 0.25in² to 5 × 5in² produced measurable surface temperature depressions of approximately 4–10°C during transient cooling, exceeding the effective noise floor of the camera by more than two standard deviations. Thicker laminates exhibited prolonged defect detectability windows due to increased thermal diffusion time. In contrast, embedded Teflon inclusions generated weak thermal contrasts of ≤ 3°C, approaching the measurement noise floor, due to limited thermal property contrast with the surrounding glass fiber composite. These results establish quantitative detectability limits for stationary thermographic inspection of sandwich composite panels under manufacturing-representative thermal cycles.

Barakat, Abdallah [ORNL] (ORCID:0000000296141398)↗

Effects of Perfluorinated Alkyl Substances (PFAS) on Amphibian Body and Liver Conditions: Is Lipid Metabolism Being Perturbed throughout Metamorphosis?

Per- and polyfluoroalkyl substances (PFAS) may interact with peroxisome proliferator activated receptors (PPARs) and alter lipid homeostasis. Using Xenopus laevis, we investigated the effect of PFAS on (a) lipid homeostasis and whether this correlated to changes in body and hepatic condition; (b) the expression of hepatic genes regulated by PPAR; and (c) the hepatic lipidome. We chronically exposed tadpoles to 0.5 µg/L of either PFOS, PFHxS, PFOA, PFHxA, a binary mixture of PFOS and PFHxS (0.5 µg/L of each), or a control, from NF stage 52 through metamorphic climax. Growth, development, and survival were not affected, but we detected a sex-specific decrease in body condition at NF 66 (6.8%) and in hepatic condition (16.6%) across metamorphic climax for male tadpoles exposed to PFOS. We observed weak evidence for the transient downregulation of apolipoprotein-V (apoa5) at NF 62 in tadpoles exposed to PFHxA. Acyl-CoA oxidase 1 (acox1) was downregulated only in males exposed to PFHxS (Ln(Fold Change) = −0.54). We detected PFAS-specific downregulation of structural glycerophospholipids, while semi-quantitative profiling detected the upregulation in numerous glycerophospholipids, sphingomyelins, and diglycerides. Overall, our findings indicate that PFAS can induce sex-specific effects that change across larval development and metamorphosis. We demonstrate that PFAS alter lipid metabolism at environmentally relevant concentrations through divergent mechanisms that may not be related to PPARs, with an absence of effects on body condition, demonstrating the need for more molecular studies to elucidate mechanisms of PFAS-induced lipid dysregulation in amphibians and in other taxa.

Bushong, Anna (ORCID:0000000249630578)↗

RE-INTEGRATE EMT Simulation Software: Graph Convolutional Network for Sparse Matrix Pattern Detection

The increasing complexity of power networks, driven by proliferation of inverters, presents analytical challenges that simplified models often fail to capture, necessitating Electromagnetic Transient (EMT) simulations. EMT models are represented as discretized differential-algebraic equations (DAEs), forming a linear system Ax = b that is computationally intensive to solve. Due to inherent sparsity of adjacency matrix A, distinct patterns emerge that, when accurately identified, enable efficient solver selection to minimize computation time. However, identifying ideal pattern is complicated by numerous reordering algorithms and limited structural insights. To address this, we introduce a Graph Convolutional Network (GCN) model for classifying sparse matrix patterns common in power system analysis. The model, achieving 96% test accuracy, is validated using PV plant models of 125 MW capacities connected to New England 39-bus transmission system (TS), and further scaled to a 4,992-bus network with 384 PV plants, yielding 191, 616 × 191, 616 sized A matrix. For all cases, the GCN model accurately identifies the matrix’s intrinsic sparse pattern, demonstrating its potential to enhance solver performance in EMT analysis.

Hossain, Md Rifat [Florida International Universit↗

Photometric classification of Hyper Suprime-Cam transients using machine learning

Abstract The advancement of technology has resulted in a rapid increase in supernova (SN) discoveries. The Subaru/Hyper Suprime-Cam (HSC) transient survey, conducted from fall 2016 through spring 2017, yielded 1824 SN candidates. This gave rise to the need for fast type classification for spectroscopic follow-up and prompted us to develop a machine learning algorithm using a deep neural network with highway layers. This algorithm is trained by actual observed cadence and filter combinations such that we can directly input the observed data array without any interpretation. We tested our model with a dataset from the LSST classification challenge (Deep Drilling Field). Our classifier scores an area under the curve (AUC) of 0.996 for binary classification (SN Ia or non-SN Ia) and 95.3% accuracy for three-class classification (SN Ia, SN Ibc, or SN II). Application of our binary classification to HSC transient data yields an AUC score of 0.925. With two weeks of HSC data since the first detection, this classifier achieves 78.1% accuracy for binary classification, and the accuracy increases to 84.2% with the full dataset. This paper discusses the potential use of machine learning for SN type classification purposes.

Takahashi, Ichiro↗

Cadmium Magnesium Telluride for Next Generation X-Ray Free Electron Laser, Synchrotron and Many Other Applications

We developed a picosecond photodetector based on our Bridgman grown and specially engineered Cadmium Magnesium Telluride (Cd 1-x Mg x Te) single crystal that is sensitive to both optical and x-ray pulses for coarse timing in Free Electron Laser applications. Cd 1-x Mg x Te is a wide bandgap semiconductor material with potential applications, not only in optoelectronics, but also in particle physics as an intense pulse radiation detector for bremsstrahlung, X-ray/gamma ray radiation, thermal neutrons, and medical imaging. However, for femtosecond optical and x-ray cross correlation, the material has to have very short lifetime, a condition that is opposite to that required for nuclear spectroscopy applications. At the same time, the material also needs to have very low bulk leakage current, in the 0.10 pA range. Hence the ability to tailor or engineer the material is very crucial. In this paper, picosecond response and the crystal growth of this specially engineered cadmium magnesium telluride material will be presented. Other material characterization and transient measurements will also be discussed along with room temperature semiconductor detector performance for other nuclear radiation detection applications.

36 MATERIALS SCIENCE↗

Reduced-dimension Bayesian optimization for model calibration of transient vapor compression cycles

Development and calibration of first-principles dynamic models of vapor compression cycles (VCCs) is of critical importance for applications that include control design and fault detection and diagnostics. Nevertheless, the inherent complexity of models that are represented by large systems of differential–algebraic equations leads to significant challenges for model calibration processes that utilize classical gradient-based methods. Bayesian optimization (BO) is a sample-efficient and gradient-free approach using a probabilistic surrogate model and optimal search over a feasible parameter space. Despite the benefits of BO in reducing computational costs, challenges remain in dealing with a high-dimensional calibration task resulting from a large set of parameters that have significant impacts on system behavior and need to be calibrated simultaneously. This paper presents a reduced-dimension BO framework for calibrating transient VCCs models where the calibration space is projected to a low-dimensional subspace for accelerating convergence of the solution algorithm and consequently reducing the number of transient simulations. The proposed approach was demonstrated via two case studies associated with different VCC applications where 10 parameters were calibrated in each case using laboratory measurements. The reduced-dimension BO framework only required 1 / 8 th of the iterations associated with a standard BO method that deals with high-dimensional calibration parameters for converged solutions and yielded comparable accuracy. Furthermore, both calibrated models revealed significant accuracy improvements compared to uncalibrated models.

Ma, Jiacheng↗

Revealing electronic state-switching at conical intersections in alkyl iodides by ultrafast XUV transient absorption spectroscopy

Conical intersections between electronic states often dictate the chemistry of photoexcited molecules. Recently developed sources of ultrashort extreme ultraviolet (XUV) pulses tuned to element-specific transitions in molecules allow for the unambiguous detection of electronic state-switching at a conical intersection. Here, the fragmentation of photoexcited iso-propyl iodide and tert-butyl iodide molecules (i-C 3 H 7 I and t-C 4 H 9 I) through a conical intersection between 3 Q 0 / 1 Q 1 spin-orbit states is revealed by ultrafast XUV transient absorption measuring iodine 4d core-to-valence transitions. The electronic state-sensitivity of the technique allows for a complete mapping of molecular dissociation from photoexcitation to photoproducts. In both molecules, the sub-100 fs transfer of a photoexcited wave packet from the 3 Q 0 state into the 1 Q 1 state at the conical intersection is captured. The results show how differences in the electronic state-switching of the wave packet in i-C 3 H 7 I and t-C 4 H 9 I directly lead to differences in the photoproduct branching ratio of the two systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The phantom menace of dynamic soft-shorts in solid-state battery research

Solid-state batteries with lithium metal anodes present the highest energy density batteries for applications in electric vehicles, leading to massive R&D investments over the past decade. Although most research focuses on preventing lithium metal dendrites that eventually short the battery, the nature of these shorts remains elusive. Soft-shorts, in particular, receive little attention or are not recognized, even in published data. Here, in this study, we present a comprehensive outline of the detection and analysis of soft -shorts in solid-state lithium metal cells with composite polymer electrolytes as well as a fundamental understanding of the dynamics of soft -shorts. Transient un-shorting of soft -shorts that occurs on the micro-to-millisecond timescale-driven by joule heating, chemical reactivity, and other processes-limits one's ability to determine whether the cell was or is still shorted. We provide numerous experimental methods to detect and analyze soft-shorts in any battery type as a resource to all battery researchers.

25 ENERGY STORAGE↗

Machine-learning based prediction of injection rate and solenoid voltage characteristics in GDI injectors

We report that current state-of-the-art gasoline direct-injection (GDI) engines use multiple injections as one of the key technologies to improve exhaust emissions and fuel efficiency. For this technology to be successful, secured adequate control of fuel quantity for each injection is mandatory. However, nonlinearity and variations in the injection quantity can deteriorate the accuracy of fuel control, especially with small fuel injections. Therefore, it is necessary to understand the complex injection behavior and to develop a predictive model to be utilized in the development process. This study presents a methodology for rate of injection (ROI) and solenoid voltage modeling using artificial neural networks (ANNs) constructed from a set of Zeuch-style hydraulic experimental measurements conducted over a wide range of conditions. A quantitative comparison between the ANN model and the experimental data shows that the model is capable of predicting not only general features of the ROI trend, but also transient and non-linear behaviors at particular conditions. In addition, the end of injection (EOI) could be detected precisely with a virtually generated solenoid voltage signal and the signal processing method, which applies to an actual engine control unit. A correlation between the detected EOI timings calculated from the modeled signal and the measurement results showed a high coefficient of determination.

42 ENGINEERING↗

Solution phase high repetition rate laser pump x-ray probe picosecond hard x-ray spectroscopy at the Stanford Synchrotron Radiation Lightsource

We present a dedicated end-station for solution phase high repetition rate (MHz) picosecond hard x-ray spectroscopy at beamline 15-2 of the Stanford Synchrotron Radiation Lightsource. A high-power ultrafast ytterbium-doped fiber laser is used to photoexcite the samples at a repetition rate of 640 kHz, while the data acquisition operates at the 1.28 MHz repetition rate of the storage ring recording data in an alternating on-off mode. The time-resolved x-ray measurements are enabled via gating the x-ray detectors with the 20 mA/70 ps camshaft bunch of SPEAR3, a mode available during the routine operations of the Stanford Synchrotron Radiation Lightsource. As a benchmark study, aiming to demonstrate the advantageous capabilities of this end-station, we have conducted picosecond Fe K-edge x-ray absorption spectroscopy on aqueous [FeII(phen)3]2+, a prototypical spin crossover complex that undergoes light-induced excited spin state trapping forming an electronic excited state with a 0.6–0.7 ns lifetime. In addition, we report transient Fe Kβ main line and valence-to-core x-ray emission spectra, showing a unique detection sensitivity and an excellent agreement with model spectra and density functional theory calculations, respectively. Notably, the achieved signal-to-noise ratio, the overall performance, and the routine availability of the developed end-station have enabled a systematic time-resolved science program using the monochromatic beam at the Stanford Synchrotron Radiation Lightsource.

47 OTHER INSTRUMENTATION↗

Searching for gravitational waves with strongly lensed repeating fast radio bursts

We report that since their serendipitous discovery, fast radio bursts (FRBs) have garnered a great deal of attention from both observers and theorists. A new class of radio telescopes with wide fields of view have enabled a rapid accumulation of FRB observations, confirming that FRBs originate from cosmological distances. The high occurrence rate of FRBs and the development of new instruments to observe them create opportunities for FRBs to be utilized for a host of astrophysical and cosmological studies. We focus on the rare, and as yet undetected, subset of FRBs that undergo repeated bursts and are strongly gravitationally lensed by intervening structure. An extremely precise timing of burst arrival times is possible for strongly lensed repeating FRBs, and we show how this timing precision enables the search for long-wavelength gravitational waves, including those sourced by supermassive black hole binary systems. The timing of burst arrival for strongly lensed repeating FRBs is sensitive to gravitational-wave sources near the FRB host galaxy, which may lie at cosmological distances and would therefore be extremely challenging to detect by other means. Timing of strongly lensed FRBs can also be combined with pulsar timing array data to search for correlated time delays characteristic of gravitational waves passing through the Earth.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Light- and Elevated-Temperature-Induced Degradation-Affected Silicon Cells From a Utility-Scale Photovoltaic System Characterized by Deep-Level Transient Spectroscopy

Photovoltaic modules from a utility-scale field experienced power loss by light- and elevated-temperature-induced degradation (LeTID). Samples from the affected monocrystalline silicon cells are cored and extracted from the module packaging and then laser-scribed to form 2-mm diameter isolated areas. Using deep-level transient spectroscopy, a majority-carrier, hole-trap defect with an activation energy of 0.42 eV is detected on degraded and regenerated samples. The LeTID-degraded sample, however, has a larger signal corresponding to a trap density of 1.1 x 10 13 cm -3 , which is about five times larger than the 2.1 x 10 12 cm -3 trap density of the regenerated sample. An increase in filling pulse time from 50 u s to 20 ms shows a slight decrease in activation energy from 0.42 to 0.36 eV suggesting that the defect level may consist of a band of energy states where shallower states continue to fill with long filling times. The capture rate of the defect is directly measured using an increasing series of filling pulsewidths in 15 to 125 ns range. This leads to a measured capture cross section of 5.1 x 10 -17 cm 2 , and using an approximate defect density of 10 13 cm -3 , the majority-carrier-hole lifetime related to this defect is approximately 100 u s when in the LeTID-degraded state.

charge carrier lifetime↗

High Performance Pd/4H-SiC Epitaxial Schottky Barrier Radiation Detectors for Harsh Environment Applications

Although many refractory metals have been investigated as the choice of contact metal in 4H-SiC devices, palladium (Pd) as a Schottky barrier contact for 4H-SiC radiation detectors for harsh environment applications has not been investigated adequately. Pd is a refractory metal with high material weight-to-thickness ratio and a work function as high as nickel, one of the conventional metal contacts for high performing 4H-SiC Schottky barrier detectors (SBDs). In this article, Pd/4H-SiC epitaxial SBDs have been demonstrated for the first time as a superior self-biased (0 V applied bias) radiation detector when compared to benchmark Ni/4H-SiC SBDs. The Pd/4H-SiC SBD radiation detectors showed a very high energy resolution of 1.9% and 0.49% under self- and optimized bias, respectively, for 5486 keV alpha particles. The SBDs demonstrated a built-in voltage (V bi ) of 2.03 V and a hole diffusion length (L d ) of 30.8 µm. Such high V bi and L d led to an excellent charge collection efficiency of 76% in the self-biased mode. Capacitance mode deep level transient spectroscopy (DLTS) results revealed that the “lifetime-killer” Z 1/2 trap centers were present in the 4H-SiC epilayer. Another deep level trap was located at 1.09 eV below the conduction band minimum and resembles the EH5 trap with a concentration of 1.98 × 10 11 cm –3 and capture cross-section 1.7 × 10 –17 cm –2 ; however, the detector performance was found to be limited by charge trapping in the Z 1/2 center. The results presented in this article revealed the unexplored potential of a wide bandgap semiconductor, SiC, as high-efficiency self-biased radiation detectors. Such high performance self-biased radiation detectors are poised to address the longstanding problem of designing self-powered sensor devices for harsh environment applications e.g., advanced nuclear reactors and deep space missions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Millimeter-wave Detections of Symbiotic Stars in SPT and ACT Data

We present the results of a joint targeted search of candidate symbiotic stars at millimeter wavelengths using the South Pole Telescope (SPT) and the Atacama Cosmology Telescope (ACT). Candidates are selected from the New Online Database of Symbiotic Variables, restricting to objects that are within either the SPT-3G or ACT~DR6 footprint, covering most of the southern hemisphere and up to a declination of $+20^\circ$. Forced photometry on the 828 candidate symbiotic star locations in SPT and ACT data results in 31 unique objects detected with more than a $3σ$ significance using two frequency bands: 18 confirmed and 13 suspected symbiotic stars. We provide the SPT and ACT 95/98, 150, and 220~GHz light curves, along with optical and infrared light curves from 2016--2026, as well as spectral energy distributions, physical parameters from the literature, and brief summaries regarding the nature of each individual object. Using Herschel SPIRE data from 2013, we place upper limits on millimeter flux for CN Cha near the beginning of the optical rise in its 2012/2013 nova, which suggests a strong variability and lag at millimeter wavelengths and results in a rare observance of a Galactic millimeter slow transient. In addition, we provide coadded thumbnails and light curves for the remaining 797 candidate symbiotic stars that did not pass our detection thresholds. Millimeter-wave emission from symbiotic stars is primarily a combination of free-free emission of the ionization region and optically thick blackbody emission of the cooler dust components of the system. When combined with contemporaneous multi-wavelength observations, millimeter-wave observations can be used to test binary models of symbiotic stars and provide insight on the geometry and physical properties of these systems.

Tandoi, C. [Illinois U., Urbana, Astron. Dept.] (O↗

The Fuel Motion Monitoring System at TREAT - Current Status and Future Plans

An important component of the United States Nuclear Fuel Safety Transient Testing Program, the Fuel Motion Monitoring System (FMMS) at Idaho National Laboratory's Transient Reactor Test Facility (TREAT) is fast-neutron hodoscope capable of imaging the location, movement, and relocation of nuclear fuel experiments under simulated transient accident conditions. The FMMS was refurbished in parallel with the TREAT restart program starting in 2014, restoring 96-channels of fast-neutron detection. Since returning to operation in 2017 the FMMS has supported many fuel safety experiments supporting accident tolerant fuel development, light-water reactor safety, space thermal nuclear propulsion fuel development, and advanced reactor research and development. In Phase 2 of the FMMS restoration. work is now under way to expand the FMMS' field-of-view by adding an additional 96 channels of fast neutron detectors to the system's hodoscope, along with an expanded data acquisition system and associated transient timing electronics. An overview of the FMSS system and its fast-neutron detectors will be presented along with examples of current FMMS imaging performance and associated information.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Search for Continuous and Transient Neutrino Emission Associated with IceCube’s Highest-energy Tracks: An 11 yr Analysis

IceCube alert events are neutrinos with a moderate-to-high probability of having astrophysical origin. In this study, we analyze 11 yr of IceCube data and investigate 122 alert events and a selection of high-energy tracks detected between 2009 and the end of 2021. This high-energy event selection (alert events + high-energy tracks) has an average probability of ≥0.5 of being of astrophysical origin. We search for additional continuous and transient neutrino emission within the high-energy events' error regions. We find no evidence for significant continuous neutrino emission from any of the alert event directions. The only locally significant neutrino emission is the transient emission associated with the blazar TXS 0506+056, with a local significance of 3σ, which confirms previous IceCube studies. When correcting for 122 test positions, the global p-value is 0.156 and compatible with the background hypothesis. We constrain the total continuous flux emitted from all 122 test positions at 100 TeV to be below 1.2 × 10 –15 (TeV cm 2 s) –1 at 90% confidence assuming an E –2 spectrum. This corresponds to 4.5% of IceCube's astrophysical diffuse flux. Overall, we find no indication that alert events in general are linked to lower-energetic continuous or transient neutrino emission.

79 ASTRONOMY AND ASTROPHYSICS↗