Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “tomographic imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Limited-view 3D Imaging Technology or “LV 3D Imaging” Technology Assessment

Limited View 3D or “LV 3D” imaging is important because it addresses a technology gap that has life, time, radiation dose and monetary-saving impacts. It provides something that currently does not exist and its potential products open a variety of technology domains in which SRNL could become competitive in. It can become a low cost, safer and alternative approach to conducting what is commonly referred to as computer tomographic imaging. This project develops a bucket list of technologies that will be needed to develop a portable system for conducting LV 3D imaging.

47 OTHER INSTRUMENTATION↗

Muon Tracing and Image Reconstruction Algorithms for Cosmic Ray Muon Computed Tomography

Cosmic ray muon-computed tomography (μCT) is a new imaging modality with unique characteristics that could be particularly important for diverse applications including nuclear nonproliferation, spent nuclear fuel monitoring, cargo scanning, and volcano imaging. The strong scattering dependence of muons on atomic number Z in combination with high penetration range could offer a significant advantage over existing techniques when dense, shielded containers must be imaged. However, μCT reconstruction using conventional filtered back-projection is limited due to the overly simple assumptions that do not consider the curved path caused by multiple Coulomb scattering prompting the need for more sophisticated approaches to be developed. Here, we argue that the use of improved muon tracing and scattering angle projection algorithms as well as an algebraic reconstruction technique should produce muon tomographic images with improved quality–or require fewer muons to produce the same image quality–compared to the case where conventional methods are used. We report on the development and assessment of three novel muon tracing methods and two scattering angle projection methods for μCT. Simulated dry storage casks with single and partial missing fuel assemblies were used as numerical examples to assess and compare the proposed methods. The reconstructed images showed an expected improvement in image quality when compared with conventional techniques, even without muon momentum information, which should lead to improved detection capability, even for partial defects.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Molecular Breast Imaging Using Emission Tomosynthesis

Purpose: Tour objective is to design a novel SPECT system for molecular breast imaging (MBI) and evaluate its performance. The limited angle SPECT system, or emission tomosynthesis, is designed to achieve 3D images of the breast with high spatial resolution/sensitivity. The system uses a simplified detector motion and is conducive to on-board biopsy and mult-modal imaging with mammography. Methods: The novel feature of the proposed gamma camera is a variable-angle, slant-hole (VASH) collimator, which is well suited for limited angle SPECT of a mildly compressed breast. The collimator holes change slant angle while the camera surface remains flush against the compression paddle. This allows the camera to vary the angular view ({+-}30{degrees}, {+-}45{degrees}) for tomographic imaging while keeping the camera close to the object for high spatial resolution and/or sensitivity. Theoretical analysis and Monte Carlo simulations were performed assuming a point source and isolated breast phantom. Spatial resolution, sensitivity, contrast and SNR were measured. Results were compared to single-view, planar images and conventional SPECT. For both conventional SPECT and VASH, data were reconstructed using iterative algorithms. Finally, a proof-of-concept VASH collimator was constructed for experimental evaluation. Results: Measured spatial resolution/sensitivity with VASH showed good agreement with theory including depth-of-interaction (DOI) effects. The DOI effect diminished the depth resolution by approximately 2 mm. Increasing the slant angle range from {+-}30{degrees} to {+-}45{degrees} resulted in an approximately 1 mm improvement in the depth resolution. In the breast phantom images, VASH showed improved contrast and SNR over conventional SPECT and improved contrast over planar scintimmammography. Reconstructed images from the proof-of-concept VASH collimator demonstrated reasonable depth resolution capabilities using limited angle projection data. Conclusion: We conclude that this limited angle SPECT approach using a VASH collimator can achieve superior 3D image quality for MBI in a design that has attractive characteristics for clinical imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Limited-view 3D Imaging Technology or “LV 3D Imaging” Technology Assessment

Limited View 3D or “LV 3D” imaging is important because it addresses a tech nology gap that has life, time, radiation dose and monetary-saving impacts. It provides something that currently does not exist and its potential products open a variety of technology domains in which SRNL could become competitive in. It can become a low cost, safer and alternative approach to conducting what is commonly referred to as computer tomographic imaging. This project develops a bucket list of technologies that will be needed to develop a portable system for conducting LV 3D imaging.

47 OTHER INSTRUMENTATION↗

IMAGING THE SOLAR TACHOCLINE BY TIME-DISTANCE HELIOSEISMOLOGY

The solar tachocline at the bottom of the convection zone is an important region for the dynamics of the Sun and the solar dynamo. In this region, the sound speed inferred by global helioseismology exhibits a bump of approximately 0.4% relative to the standard solar model. Global helioseismology does not provide any information on possible latitudinal variations or asymmetries between the northern and southern hemisphere. Here, we develop a time-distance helioseismology technique, including surface- and deep-focusing measurement schemes and a combination of both, for two-dimensional tomographic imaging of the solar tachocline that infers radial and latitudinal variations in the sound speed. We test the technique using artificial solar oscillation data obtained from numerical simulations. The technique successfully recovers major features of the simplified tachocline models. The technique is then applied to SOHO/MDI medium-l data and provides for the first time a full two-dimensional sound-speed perturbation image of the solar tachocline. The one-dimensional radial profile obtained by latitudinal averaging of the image is in good agreement with the previous global helioseismology result. It is found that the amplitude of the sound-speed perturbation at the tachocline varies with latitude, but it is not clear whether this is in part or fully an effect of instrumental distortion. Our initial results demonstrate that time-distance helioseismology can be used to probe the deep interior structure of the Sun, including the solar tachocline.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-F-T-434: Development of a Fan-Beam Optical Scanner Using CMOS Array for Small Field Dosimetry

Purpose: To design and construct a second generation optical computed tomography (OCT) system using a fan-beam with a CMOS array detector for the 3D dosimetry with polymer gel and radiochromic solid dosimeters. The system was specifically designed for the small field dosimetry. Methods: The optical scanner used a fan-beam laser, which was produced from a collimated red laser beam (λ=620 nm) with a 15-degree laser-line generating lens. The fan-beam was sent through an index-matching bath which holds the sample stage and a sample. The emerging laser light was detected with a 2.54 cm-long CMOS array detector (512 elements). The sample stage rotated through the full 360 degree projection angles at 0.9-degree increments. Each projection was normalized to the unirradiated sample at the projection angle to correct for imperfections in the dosimeter. A larger sample could be scanned by using a motorized mirror and linearly translating the CMOS detector. The height of the sample stage was varied for a full 3D scanning. The image acquisition and motor motion was controlled by a computer. The 3D image reconstruction was accomplished by a fan-beam reconstruction algorithm. All the software was developed inhouse with MATLAB. Results: The scanner was used on both PRESAGE and PAGAT gel dosimeters. Irreconcilable refraction errors were seen with PAGAT because the fan beam laser line refracted away from the detector when the field was highly varying in 3D. With PRESAGE, this type of error was not seen. Conclusion: We could acquire tomographic images of dose distributions by the new OCT system with both polymer gel and radiochromic solid dosimeters. Preliminary results showed that the system was more suited for radiochromic solid dosimeters since the radiochromic dosimeters exhibited minimal refraction and scattering errors. We are currently working on improving the image quality by thorough characterization of the OCT system.

60 APPLIED LIFE SCIENCES↗

SU-D-201-06: Random Walk Algorithm Seed Localization Parameters in Lung Positron Emission Tomography (PET) Images

Purpose: The objective of this study was to find the best seed localization parameters in random walk algorithm application to lung tumor delineation in Positron Emission Tomography (PET) images. Methods: PET images suffer from statistical noise and therefore tumor delineation in these images is a challenging task. Random walk algorithm, a graph based image segmentation technique, has reliable image noise robustness. Also its fast computation and fast editing characteristics make it powerful for clinical purposes. We implemented the random walk algorithm using MATLAB codes. The validation and verification of the algorithm have been done by 4D-NCAT phantom with spherical lung lesions in different diameters from 20 to 90 mm (with incremental steps of 10 mm) and different tumor to background ratios of 4:1 and 8:1. STIR (Software for Tomographic Image Reconstruction) has been applied to reconstruct the phantom PET images with different pixel sizes of 2×2×2 and 4×4×4 mm{sup 3}. For seed localization, we selected pixels with different maximum Standardized Uptake Value (SUVmax) percentages, at least (70%, 80%, 90% and 100%) SUVmax for foreground seeds and up to (20% to 55%, 5% increment) SUVmax for background seeds. Also, for investigation of algorithm performance on clinical data, 19 patients with lung tumor were studied. The resulted contours from algorithm have been compared with nuclear medicine expert manual contouring as ground truth. Results: Phantom and clinical lesion segmentation have shown that the best segmentation results obtained by selecting the pixels with at least 70% SUVmax as foreground seeds and pixels up to 30% SUVmax as background seeds respectively. The mean Dice Similarity Coefficient of 94% ± 5% (83% ± 6%) and mean Hausdorff Distance of 1 (2) pixels have been obtained for phantom (clinical) study. Conclusion: The accurate results of random walk algorithm in PET image segmentation assure its application for radiation treatment planning and diagnosis.

60 APPLIED LIFE SCIENCES↗

Image quality evaluation of breast tomosynthesis with synchrotron radiation

Purpose: This study investigates the image quality of tomosynthesis slices obtained from several acquisition sets with synchrotron radiation using a breast phantom incorporating details that mimic various breast lesions, in a heterogeneous background. Methods: A complex Breast phantom (MAMMAX) with a heterogeneous background and thickness that corresponds to 4.5 cm compressed breast with an average composition of 50% adipose and 50% glandular tissue was assembled using two commercial phantoms. Projection images using acquisition arcs of 24 Degree-Sign , 32 Degree-Sign , 40 Degree-Sign , 48 Degree-Sign , and 56 Degree-Sign at incident energy of 17 keV were obtained from the phantom with the synchrotron radiation for medical physics beamline at ELETTRA Synchrotron Light Laboratory. The total mean glandular dose was set equal to 2.5 mGy. Tomograms were reconstructed with simple multiple projection algorithm (MPA) and filtered MPA. In the latter case, a median filter, a sinc filter, and a combination of those two filters were applied on the experimental data prior to MPA reconstruction. Visual inspection, contrast to noise ratio, contrast, and artifact spread function were the figures of merit used in the evaluation of the visualisation and detection of low- and high-contrast breast features, as a function of the reconstruction algorithm and acquisition arc. To study the benefits of using monochromatic beams, single projection images at incident energies ranging from 14 to 27 keV were acquired with the same phantom and weighted to synthesize polychromatic images at a typical incident x-ray spectrum with W target. Results: Filters were optimised to reconstruct features with different attenuation characteristics and dimensions. In the case of 6 mm low-contrast details, improved visual appearance as well as higher contrast to noise ratio and contrast values were observed for the two filtered MPA algorithms that exploit the sinc filter. These features are better visualized at extended arc length, as the acquisition arc of 56 Degree-Sign with 15 projection images demonstrates the highest image reconstruction quality. For microcalcifications, filtered MPA implemented with a combination of median and sinc filters indicates better feature appearance due to efficient suppression of background tissue. The image quality of these features is less sensitive to the acquisition arc. Calcifications with size ranging from 170 to 500 {mu}m, like the ones presently studied, are well identified and visualized for all arcs used. The comparison of single projection images obtained under different beam conditions showed that the use of monochromatic beam can produce an image with higher contrast and contrast to noise ratio compared to an image corresponding to a polychromatic beam even when the latter is acquired with double incident exposure. Conclusions: Filter optimization in respect to the type of feature characteristics is important before the reconstruction. The MPA combined with median and sinc filters results in improved reconstruction of microcalcifications and low-contrast features. The latter are better visualized at extended arc length, while microcalcifications are less sensitive to this acquisition parameter. Use of monochromatic beams may result in tomographic images with higher contrast acquired at lower incident exposures.

60 APPLIED LIFE SCIENCES↗

NMIS with Imaging and Gamma Ray Spectrometry for Pu, HEU, HE and Other Materials

The Nuclear Material Identification System (NMIS) has been under development at ORNL and the National Nuclear Security Administration (NNSA) Y-12 National Security Complex since 1984. In the mid-1990s, what is now the US Department of Energy (DOE) Office of Nuclear Verification (ONV) realized that it was a useful technology for future arms control treaty applications and supported further development of the system. In 2004, fast-neutron imaging was incorporated into the system. In 2007, the ONV decided to develop a fieldable version of the system, designated as FNMIS, for potential use in future treaties. The FNMIS is being developed to be compatible with the eventual incorporation of gamma-ray spectrometry and an information barrier. This report addresses how and what attributes could be determined by the FNMIS system with gamma-ray spectrometry. The NMIS is a time-dependent coincidence system that incorporates tomographic imaging (including mapping of the fission sites) and gamma-ray spectrometry. It utilizes a small, lightweight (30 lb), portable deuterium-tritium (DT) neutron (14.1 MeV) generator (4 x 10 7 neutrons/second) for active interrogation and can also perform passive interrogation. A high-purity germanium (HPGe) gamma-ray detector with multichannel analysis can be utilized in conjunction with the source for active interrogation or passively. The system uses proton recoil scintillators: 32 small 2.5 x 2.5 x 10.2-cm-thick plastic scintillators for imaging and at least two 2 x 2 arrays of 27 x 27 x 10-cm-thick plastic scintillators that detect induced fission radiation. The DT generator contains an alpha detector that time and directionally tags a fan beam of some of the neutrons emitted and subdivides it into pixels. A fast (1 GHz) time correlation processor measures the time-dependent coincidence among all detectors in the system. A computer-controlled scanner moves the small detectors and the source appropriately for scanning a target object for imaging. The system is based on detection of transmitted 14.1 MeV neutrons, fission neutrons, and gamma rays from spontaneous, inherent source fission of the target, fission neutrons and gamma rays induced by the external DT source, gamma rays from natural emissions of uranium and plutonium, and induced gamma-ray emission by the interaction of the 14.1 MeV neutrons from the DT source. The NMIS can and has been used with a time-tagged californium spontaneous fission source. It has also been used with pulsed interrogation sources such as LINACs, DT, and deuterium-deuterium (DD) sources. This system is uniquely suited for detection of shielded highly enriched uranium (HEU), plutonium, and other special nuclear materials and detection of high explosives (HE) and chemical agents. The NMIS will be adapted to utilize a trusted processor that incorporates information barrier and authentication techniques using open software and then be useful in some international applications for materials whose characteristics may be classified. The proposed information barrier version of the NMIS system would consist of detectors and cables, the red (classified side) computer system, which processes the data, and the black (unclassified side) computer, which handles the computer interface. The system could use the 'IB wrapper' concept proposed by Los Alamos National Laboratory and the software integrity (digital signatures) system proposed by Sandia. Since it is based entirely on commercially available components, the entire system, including NMIS data acquisition boards, can be built with commercial off-the-shelf components. This system is being developed into a fieldable system (FNMIS) for potential arms control treaties by the ONV. The system will be modularly constructed with the RF shielded modules connected to the processor by appropriate control and signal cable in metal conduit. The FNMIS is presently being designed for eventual incorporation of gamma-ray spectrometry and an information barrier to protect classified information. The system hardware and software can be configured to obtain the following: plutonium presence, plutonium mass, Pu-240/239 ratio, plutonium geometry, plutonium metal vs non-metallic (absence of metal), time (age) since processing for plutonium (or last purification), uranium presence, uranium mass, uranium enrichment, uranium geometry, uranium metal vs non-metallic compound (absence of metal), beryllium presence and mass, tritium and deuterium gas bottle presence, HE, and chemical weapons. A matrix of the quantities determined, the method of determination, whether active (external neutron source) or passive, and the measurement equipment involved is given in the Tables 1-4. Some of these attributes can be obtained by multiple data analysis methods. The gamma-ray spectrometry methods for HEU, plutonium, and HE have been developed by other laboratories, are well known, and will be incorporated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The effects of burial diagenesis on multiscale porosity in the St. Peter Sandstone: An imaging, small-angle, and ultra-small-angle neutron scattering analysis

To examine the effects of burial diagenesis on heirarchical pore structures in sandstone and compare those with the effects of overgrowth formation, we obtained samples of St. Peter Sandstone from drill cores obtained in the Illinois and Michigan Basins. The multiscale pore structure of rocks in sedimentary reservoirs and the mineralogy associated with those pores are critical factors for estimating reservoir properties, including fluid mass in place, permeability, and capillary pressures, as well as geochemical interactions between the rock and the fluid. The combination of small- and ultra-small-angle neutron scattering with backscattered electron or X ray-computed tomographic imaging, or both, provided a means by which pore structures were quantified at scales ranging from aproximately 1 nm to 1 cm—seven orders of magnitude. Larger scale (>10 µm) porosity showed the expected logarithmic decrease in porosity with depth, although there was significant variation in each sample group. However, small- and ultra-small-angle neutron scattering data showed that the proportion of small-scale porosity increased with depth. Porosity distributions were not continuous, but consisted of a series of log normal-like distributions at several distinct scales within these rocks. Fractal dimensions at larger scales decreased (surfaces smoothed) with increasing depth, and those at smaller scales increased (surfaces roughened) and pores become more isolated (higher lacunarity). Furthermore, data suggest that changes in pore-size distributions are controlled by both physical (compaction) and chemical effects (precipitation, cementation, dissolution).

58 GEOSCIENCES↗

Upper crustal structure beneath East Java from ambient noise tomography: A preliminary result

East Java has a fairly complex geological structure. Physiographically East Java can be divided into three zones, i.e. the Southern Mountains zone in the southern part, the Kendeng zone in the middle part, and the Rembang zone in the northern part. Most of the seismic hazards in this region are due to processes in the upper crust. In this study, the Ambient Noise Tomography (ANT) method is used to image the upper crustal structure beneath East Java. We have used seismic waveform data recorded by 8Meteorological, Climatological and Geophysical Agency (BMKG) stationary seismographic stations and 16 portable seismographs installed for 2 to 8 weeks. The data were processed to obtain waveforms fromnoise cross-correlation between pairs of seismographic stations. Our preliminary results indicate that the Kendeng zone, an area of low gravity anomaly, is associated with a low velocity zone. On the other hand, the southern mountain range, which has a high gravity anomaly, is related to a high velocity anomaly as shown by our tomographic images.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Wavelength-encoded tomography based on optical temporal Fourier transform

We propose and demonstrate a technique called wavelength-encoded tomography (WET) for non-invasive optical cross-sectional imaging, particularly beneficial in biological system. The WET utilizes time-lens to perform the optical Fourier transform, and the time-to-wavelength conversion generates a wavelength-encoded image of optical scattering from internal microstructures, analogous to the interferometery-based imaging such as optical coherence tomography. Optical Fourier transform, in principle, comes with twice as good axial resolution over the electrical Fourier transform, and will greatly simplify the digital signal processing after the data acquisition. As a proof-of-principle demonstration, a 150 -μm (ideally 36 μm) resolution is achieved based on a 7.5-nm bandwidth swept-pump, using a conventional optical spectrum analyzer. This approach can potentially achieve up to 100-MHz or even higher frame rate with some proven ultrafast spectrum analyzer. We believe that this technique is innovative towards the next-generation ultrafast optical tomographic imaging application.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Spatially Resolved Temperature and Water Vapor Concentration Distributions in Supersonic Combustion Facilities by TDLAT

Detailed knowledge of the internal structure of high-enthalpy flows can provide valuable insight to the performance of scramjet combustors. Tunable Diode Laser Absorption Spectroscopy (TDLAS) is often employed to measure temperature and species concentration. However, TDLAS is a path-integrated line-of-sight (LOS) measurement, and thus does not produce spatially resolved distributions. Tunable Diode Laser Absorption Tomography (TDLAT) is a non-intrusive measurement technique for determining two-dimensional spatially resolved distributions of temperature and species concentration in high enthalpy flows. TDLAT combines TDLAS with tomographic image reconstruction. More than 2500 separate line-of-sight TDLAS measurements are analyzed in order to produce highly resolved temperature and species concentration distributions. Measurements have been collected at the University of Virginia's Supersonic Combustion Facility (UVaSCF) as well as at the NASA Langley Direct-Connect Supersonic Combustion Test Facility (DCSCTF). Due to the UVaSCF s unique electrical heating and ability for vitiate addition, measurements collected at the UVaSCF are presented as a calibration of the technique. Measurements collected at the DCSCTF required significant modifications to system hardware and software designs due to its larger measurement area and shorter test duration. Tomographic temperature and water vapor concentration distributions are presented from experimentation on the UVaSCF operating at a high temperature non-reacting case for water vitiation level of 12%. Initial LOS measurements from the NASA Langley DCSCTF operating at an equivalence ratio of 0.5 are also presented. Results show the capability of TDLAT to adapt to several experimental setups and test parameters.

Busa, K. M.↗

Synchrotron-Based Micro-CT Imaging of the Human Lung Acinus

Structural data about the human lung fine structure are mainly based on stereological methods applied to serial sections. As these methods utilize 2D images, which are often not contiguous, they suffer from inaccuracies which are overcome by analysis of 3D micro-CT images of the never-sectioned specimen. The purpose of our study was to generate a complete data set of the intact three-dimensional architecture of the human acinus using high-resolution synchrotron-based micro-CT (synMCT). A human lung was inflation-fixed by formaldehyde ventilation and then scanned in a 64-slice CT over its apex to base extent. Lung samples (8-mm diameter, 10-mm height, N = 12) were punched out, stained with osmium tetroxide, and scanned using synMCT at (4 {micro}m){sup 3} voxel size. The lung functional unit (acinus, N = 8) was segmented from the 3D tomographic image using an automated tree-analysis software program. Morphometric data of the lung were analyzed by ANOVA. Intra-acinar airways branching occurred over 11 generations. The mean acinar volume was 131.3 {+-} 29.2 mm{sup 3} (range, 92.5-171.3 mm{sup 3}) and the mean acinar surface was calculated with 1012 {+-} 26 cm{sup 2}. The airway internal diameter (starting from the bronchiolus terminalis) decreases distally from 0.66 {+-} 0.04 mm to 0.34 {+-} 0.06 mm (P < 0.001) and remains constant after the seventh generation (P < 0.5). The length of each generation ranges between 0.52 and 0.93 mm and did not show significant differences between the second and eleventh generation. The branching angle between daughter branches varies between 113-degree and 134-degree without significant differences between the generations (P < 0.3). This study demonstrates the feasibility of quantitating the 3D structure of the human acinus at the spatial resolution readily achievable using synMCT.

59 BASIC BIOLOGICAL SCIENCES↗

Imaging and characterization of γ′ and γ″ nanoparticles in Inconel 718 by EDX elemental mapping and FIB–SEM tomography

Microstructural characterization of Inconel 718 superalloy after three different heat treatment variants was performed by electron microscopy and electron tomography techniques, taking advantage of recent development in quantitative electron microscopy. Distribution maps of the chemical elements, collected by ChemiSTEM™ EDX system, offer a clear contrast between γ′, γ″, and the γ matrix. It was found that the γ′ phase contains mainly Ni, Al, and Ti, while the γ″ phase contains Ni, Nb, and Ti. Thus application of the Al and Nb STEM–EDX elemental maps enables identification and size measurements of γ′ and γ″ nanoparticles. 3D morphology of γ′ and γ″ precipitates was examined by electron microscopy and FIB–SEM tomography. Employed methods revealed that in all three heat treatment variants the γ′ particles are almost spheroidal while the γ″ precipitates are mainly elongated-disc shaped. However, the precipitate sizes differed for each variant contributing to differences in the yield strength. Tomographic images were used for estimation of the volume fraction of the both strengthening phases. - Highlights: • ChemiSTEM™ EDX elemental maps bring a fast mean to differentiate γ′ and γ″ particles. • Such maps enable for the explicit size measurements of γ′ and γ″ nanoparticles. • Explicit γ′ and γ″ phases total volume fraction was measured employing FIB–SEM. • γ′/γ″ co-precipitates and sandwich-like γ′/γ″/γ′ particles were present. • HRSTEM-HAADF imaging revealed atomic columns of the γ′/γ″ co-precipitates.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

SU-G-IeP4-08: Initial Investigations of Up-Converting Nanoparticles (UCNP) for 3D Tissue Imaging in Optical-ECT

Purpose: Near-IR absorptive up-converting nanoparticles (UCNPs) is a novel contrast for optical-ECT that allows auto-fluorescence-free 3D imaging of labeled cells in a matrix of large (∼1cm{sup 3}) unsectioned normal tissue. This has the potential to image small metastases or dormant cells that is difficult with down-converting fluorescing dyes due to auto-fluorescence. The feasibility of imaging UCNP in agarose phantoms and a mouse lung is demonstrated, aided by a 3D-printed optical-ECT stage designed to excite UCNP in a mouse lung. Methods: The UCNP, NaYF{sub 4}:Yb/Er (20/2%), studied in this work up-converts 980nm light to visible light peaking sharply at ∼540nm. To characterize the UCNP emission as a function of UCNP concentration, cylindrical 2.5%wt agarose phantoms infused with UCNP at concentrations of 25µg/mL and 50µg/mL were exposed to 1.5W 980nm laser coupled to an optical fiber. The fiber was held stably at 1cm above the stage via a custom 3D-printed stage. An optically cleared lung harvested from a BALBc mice was then injected with 100µL of 1mg/mL UCNP solution ex vivo. Tomographic imaging of the UCNP emission in lung was performed. Results: The laser beam tract is visualized within the agarose phantom. A line profile of UCNP emission at 25µg/mL versus 50µg/mL shows that increasing the UCNP concentration increases emission count. UCNPs injected into a cleared mouse lung disperse throughout the respiratory tract, allowing for visualization and 3D reconstruction. Excitation before and after UCNP injection shows the tissue exhibits no auto-fluorescence at 980nm, allowing clear view of the UCNP without any obscuring features such as conventional down-converting fluorescent tags. Conclusion: We confirm that up-conversion in tissue circumvents completely tissue auto-fluorescence, which allowed background-free 3D reconstruction of the UCNP distribution. We also confirm that raising the UCNP concentration increases emission and that UCNPs are retained in agarose samples during the optical clearing process.

60 APPLIED LIFE SCIENCES↗

Simultaneous Sensing Error Recovery and Tomographic Inversion Using an Optimization-Based Approach

Tomography can be used to reveal internal properties of a 3D object using any penetrating wave. Advanced tomographic imaging techniques, however, are vulnerable to both systematic and random errors associated with the experimental conditions, which are often beyond the capabilities of the state-of-the-art reconstruction techniques such as regularizations. Because they can lead to reduced spatial resolution and even misinterpretation of the underlying sample structures, these errors present a fundamental obstacle to full realization of the capabilities of next-generation physical imaging. In this work, we develop efficient and explicit recovery schemes of the most common experimental error: movement of the center of rotation during the experiment. We formulate new physical models to capture the experimental setup, and we devise new mathematical optimization formulations for reliable inversion of complex samples. We demonstrate and validate the efficacy of our approach on synthetic data under known perturbations of the center of rotation.

Nonlinear optimization↗

Detection of Fuel Pin Diversion via Fast Neutron Emission Tomography

Oak Ridge National Laboratory is developing a new capability to perform passive fast neutron emission tomography of spent nuclear fuel. The goal of this capability is to detect vacancies or substitutions of individual fuel pins in spent nuclear fuel assemblies for international safeguards applications, such as verifying the integrity of an assembly prior to transfer to “difficult to access” storage. Emission tomography uses collimation to isolate activity along “lines of response” through an object. By combining many collimated views through an object, the neutron emission from each fuel pin can be mathematically extracted and an image of the fuel assembly can be constructed. However, performing fast-neutron imaging is challenging for the very reason that it is desirable, namely, that fast neutrons penetrate a good deal of shielding and are consequently difficult to collimate and measure with high resolution. For spent fuel, additional challenges include the modest neutron source strength and the overwhelming gamma-ray emissions. While the International Atomic Energy Agency (IAEA) is presently investigating the use of passive gamma emission tomography for the same application, it is useful to investigate neutron emission tomography because fast neutrons better penetrate larger fuel assemblies and because fast neutrons (originating primarily from curium-244 which is mainly produced at the end of the exposure cycle) may be sensitive to replacement fuel pins that are subsequently irradiated. In the present work, we present a novel collimator concept that will enable rapid transaxial tomographic imaging of spent nuclear fuel using the spontaneous fast neutron emissions from the fuel. Initial design simulations of an imager based on this collimator indicate sufficient resolution to identify individual fuel pins. Employing such a collimator, the resulting imager can be sufficiently compact, efficient, and radiation resistant to make fast neutron emission imaging practical.

Iyengar, Anagha↗