Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “time to failure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Wind Turbine Drivetrain Reliability [Slides]

Pitch bearings, main bearings, and gearboxes in conventional wind turbine drivetrains often do not meet their 20-year minimum specified lifetime, resulting in turbine downtime as well as expensive, time-consuming repairs or replacements. The dominant failure modes of the drivetrain components and the conditions that lead to their failure are not fully accounted for during product design or routinely modeled for life management. Drivetrain reliability improvements and O&M cost reductions remain top priorities for both land-based and offshore wind turbines, especially as wind turbines continue to be deployed in increasingly remote and offshore locations, continue to increase in size, and are becoming expected to be in service beyond their original design life, all of which correspond to an increase in the impact of any reliability issues on O&M costs. This presentation summarizes the most recent activities by NREL and ANL on drivetrain reliability.

17 WIND ENERGY↗

5ω Optical Thomson Scattering Report

The 5ω Optical Thomson Scattering system on the National Ignition Facility (NIF) is a diagnostic designed to measure temporally and spatially resolved plasma conditions in Inertial Confinement Fusion (ICF) Hohlraums. The system was proposed in 2014 and a phased approach to implementation was developed. In phase one the collection system was designed, built, and fielded on the NIF to be used for 3ω Thomson scattering measurements and background measurements near 211 nm (5ω. The initial commissioning experiment for the collection system was completed in Oct. 2016. Commissioning of the collection system continued through 2017 and the system is now fielded for a range of user experiments and regularly produces publication quality data. A dedicated 5ω probe laser was designed and built to allow Thomson scattering measurements in the presence of 2 MJ of 3ω drive energy. Due to scattered light (spectral reflections, laser-plasma instabilities, and unconverted drive energy) from the 3w drive lasers typical wavelengths (2ω and 4ω) fielded at other laser facilities like the Nova Laser Facility and the Omega Laser Facility were unable to meeting the signal to background requirements in design studies. A 10 Joule 5ω probe was proposed as a solution that met requirements. This 10 Joule laser was more energetic than previously fielded 5w lasers by 2-3 orders of magnitude. As part of a risk reduction plan, phase two of the project was to develop a 1 Joule, 5ω laser to demonstrate conversion efficiency >20% from 1ω to 5ω and make initial Thomson scattering measurements in the first few nanoseconds of an ICF laser pulse. Initial tests of the 5w conversion were completed at the Laboratory for Laser Energetics (LLE) and produced record 5ω energies. Based on these results from LLE, a 1 Joule, 5w laser system was designed for the NIF in 2018 and commissioning began in 2019. Commissioning of the 5ω laser system continued through 2023 and was eventually paused in Q1 of FY24 due to completing resource constraints. Commissioning of the 5w laser system proved incredibly challenging. Multiple issues were identified during commissioning and resolved, but issues remain. Currently there is not a clear understanding of why 5ω scattered has not been detected on the OTS collection system. Based on offline measurements, calculations, and preshot measurements the system appears to meet all requirements. Potential target physics issues have been investigated and do not appear to be an issue. The current hypothesis is that there is an error in one or more aspects of the offline testing not translating to expected performance when the system is fielded on the NIF. Additional full system testing in-situ utilizing the complete OTS system and NIF target chamber center time is needed to further test potential failure modes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Disruption of Z-Disc Function Promotes Mechanical Dysfunction in Human Myocardium: Evidence for a Dual Myofilament Modulatory Role by Alpha-Actinin 2

The ACTN2 gene encodes α-actinin 2, located in the Z-disc of the sarcomeres in striated muscle. In this study, we sought to investigate the effects of an ACTN2 missense variant of unknown significance (p.A868T) on cardiac muscle structure and function. Left ventricular free wall samples were obtained at the time of cardiac transplantation from a heart failure patient with the ACTN2 A868T heterozygous variant. This variant is in the EF 3–4 domain known to interact with titin and α-actinin. At the ultrastructural level, ACTN2 A868T cardiac samples presented small structural changes in cardiomyocytes when compared to healthy donor samples. However, contractile mechanics of permeabilized ACTN2 A868T variant cardiac tissue displayed higher myofilament Ca 2+ sensitivity of isometric force, reduced sinusoidal stiffness, and faster rates of tension redevelopment at all Ca 2+ levels. Small-angle X-ray diffraction indicated increased separation between thick and thin filaments, possibly contributing to changes in muscle kinetics. Molecular dynamics simulations indicated that while the mutation does not significantly impact the structure of α-actinin on its own, it likely alters the conformation associated with titin binding. Our results can be explained by two Z-disc mediated communication pathways: one pathway that involves α-actinin’s interaction with actin, affecting thin filament regulation, and the other pathway that involves α-actinin’s interaction with titin, affecting thick filament activation. This work establishes the role of α-actinin 2 in modulating cross-bridge kinetics and force development in the human myocardium as well as how it can be involved in the development of cardiac disease.

59 BASIC BIOLOGICAL SCIENCES↗

Pin-pointing Node Failures in HPC Systems

Automated fault prediction and diagnosis in HPC systems needs to be efficient for better system resilience. With increasing scalability required for exascale, accurate fault prediction aiding in quick remedy is hard. With changing supercomputer architectures, distilling fault data from the noisy raw logs requires substantial efforts. Predicting node failures in such voluminous system logs is challenging. To this end, we investigate an interesting way to pin-point node failures in such supercomputing systems. Our study on Cray system data with automated machine learning tools suggests that specific patterns of event messages on node unavailability can be indicator to node failures. This data extraction coupled with system and job data correlation helps in devising a methodology to predict node failures and their location over a specific time frame. This work aims to enable broader applicability for a generic fault prediction framework.

Roman, E↗

Drivetrain Reliability Collaborative Update

Pitch bearings, main bearings, and gearboxes in conventional wind turbine drivetrains often do not meet their 20-year minimum specified lifetime, resulting in turbine downtime as well as expensive, time-consuming repairs or replacements. The dominant failure modes of the drivetrain components and the conditions that lead to their failure are not fully accounted for during product design or routinely modeled for life management. Drivetrain reliability improvements and O&M cost reductions remain top priorities for both land-based and offshore wind turbines, especially as wind turbines continue to be deployed in increasingly remote and offshore locations, continue to increase in size, and are becoming expected to be in service beyond their original design life, all of which correspond to an increase in the impact of any reliability issues on O&M costs. This presentation summarizes the most recent activities by NREL and ANL on drivetrain reliability.

bearing↗

Decentralized Failure-Tolerant Optimization of Electric Vehicle Charging

We present a decentralized failure-tolerant algorithm for optimizing electric vehicle (EV) charging, using charging stations as computing agents. The algorithm is based on the alternating direction method of multipliers (ADMM) and it has the following features: (i) It handles capacity, peak demand, and ancillary services coupling constraints. (ii) It does not require a central agent collecting information and performing coordination (e.g. an aggregator), instead all agents exchange information and computations are carried out in a fully decentralized fashion. (iii) It can withstand the failure of any number of computing agents, as long as the remaining computing agents are in a connected communications network. We construct this algorithm by reformulating the optimal EV charging problem in a decomposable form, amenable to ADMM, and then developing efficient decentralized solution methods for the subproblems dealing with coupling constraints. We conduct numerical experiments on industry-scale synthetic EV charging datasets, with up to 1,152 charging stations, using a high performance computing cluster. The experiments demonstrate that the proposed algorithm can solve the optimal EV charging problem fast enough to permit the integration of EV charging with real-time electricity markets, even in the presence of failures.

42 ENGINEERING↗

Precise Timing Based on Pulsar Observation for Grid Synchronization

While Global Positioning System signals are widely used as the synchronized timing Sources for wide-area measurement systems for power grid monitoring and control, they are vulnerable to failures and malicious attacks. To address this Problem, an alternative kind of timing sources, the millisecond pulsars, were proposed to serve the power grid as they are more precise and physically indestructible. Millisecond pulsars are a kind of neutron stars that emit radio pulse signals that have extremely stable periods of milliseconds. However, the observed pulse Signals from pulsars cannot be directly used for timing because of their low signal-to-noise ratio and the dispersion effects of interstellar medium. In this paper, the precise timing method based on pulsar observation data is proposed to interpret the pulsar observation data and therefrom to generate precise timing signal for the power grid synchronization. In our proposed method,. incoherent de-dispersion is used on the observation data to mitigate the effect of interstellar medium. dispersion. Then spectrum analysis and segment folding are used to precisely estimate the local pulsar period. Finally the standard pulse per second signal is generated from. the estimated pulsar period and its precision. is analyzed. Experiments with the observation data of the pulsar based timing signal can be more accurate compared to GPS timing signals.

Luo, Xiqian↗

Machine Learning for Gearbox Fault Prediction by Using Both Scada and Modeled Data

This presentation outlines the work in the paper titled "Prognostics of Wind Turbine Gearbox Bearing Failures Using SCADA and Modeled Data" published by the PHM Society and presented at its 2020 annual conference. It is accessible at https://papers.phmsociety.org/index.php/phmconf/article/download/1292/862. The technical work is on machine learning approaches for prognostics for gearbox faults. The methodology combines SCADA time series data and physics domain modeling data, derived from the models developed by the NREL team, as inputs to machine learning models to predict gearbox bearing failures with one month lead time. Based on SCADA data, modeled data, and bearing failure log data from an actual wind plant, the performances of different machine-learning models on unseen data are then evaluated using industry-standard metrics such as precision, recall, and F1 score, and AUC (area under receiver operating characteristic curve). Results show the overall system performance enhancement in predicting bearing failure when modeled data are included with SCADA data. The reduction in terms of false alarms is about 50%, and improvement in terms of precision, and F1 score, and AUC is about 33%, and 12%, and 6% respectively, based on the best modeling case in this study.

49 EE - Wind and Water Power Program - Wind (EE-4W↗

Avoiding thermal runaway in lithium-ion batteries using ultrasound detection of early failure mechanisms

Thermal runaway leading to catastrophic failure has slowed the adoption of lithium-ion batteries, highlighting the need for early warning systems. In this work, ultrasound is used to detect physical changes in 0.950 Ah Li-ion battery cells by inducing conditions associated with thermal runaway. Ultrasound signal features are extracted as the batteries are cycled under baseline conditions and subsequently subjected to constant current and voltage overcharges. Two conditions identifying failure are defined: a warning to detect the start of overcharge and an emergency stop (E-stop), to immediately take the battery out of service. Using changes in ultrasound signal features, consistent warning and stopping classifications are applied to all failure experiments. On average, a warning notification was issued after 15% of the overcharge time and an E-stop was triggered after 35% of total overcharge duration before failure. Further testing suggests that it is possible to avoid thermal runaway by reacting to intermediate, warning notifications prior to an immediate E-stop. In other words, not only can detection derived by ultrasound identify battery failure before a catastrophic event, but can also provide early, actionable warnings so that overcharges can be detected and corrected quickly enough so the battery does not need to be decommissioned.

25 ENERGY STORAGE↗

SMC 2021 Data Challenge: Analyzing Resource Utilization and User Behavior on Titan Supercomputer

Resource utilization statistics of submitted jobs on a supercomputer can help us understand how users from various scientific domains use HPC platforms and better design a job scheduler. We explore to generate insight regarding workload distribution and usage pattern domains from job scheduler trace, GPU failure information, and project-specific information collected from Titan supercomputer. Furthermore, we want to know how the scheduler performance varies over time and how the users' scheduling behavior changes following a system failure. These observations have the potential to provide valuable insight, which is helpful to prepare for system failures. These practices will help us develop and apply novel machine learning algorithms in understanding system behavior, requirement, and better scheduling of HPC systems. There are two datasets, RUR and GPU: RUR dataset is the job scheduler traces collected from the Titan supercomputer from 01/01/2015 to 07/31/2019 (2015.csv - 2019.csv). These were collected using resource Utilization Report (RUR), a Cray-developed resource-usage data collection and reporting system. It contains the usage information of its critical resources (CPU, Memory, GPU, and I/O) of each running job on Titan during that period (https://ieeexplore.ieee.org/abstract/document/8891001). It includes ProjectAreas as additional information, every job is associated with a project ID. TheProjectAreas.csv dataset provides a mapping of the project ID to its domain science. GPU dataset has information regarding GPU failure on Titan. There have been some hardware-related issues in the GPUs in Titan that caused some GPUs to fail, sometimes irrecoverably during some job runs. This dataset provides information regarding these failures during the execution of the submitted jobs. GPUs on Titan are uniquely identified by a serial number (SN), and they are installed in a location. A GPU can be installed in a location, then removed from that location following a failure, and then re-installed in a different location after fixing the problem. If the failure can't be recovered, the GPU might be removed entirely from Titan. There are two prominent types of failures that resulted in the removal of GPUs from Titan: Double Bit Error (DBE) and Out of the Bus (OTB). The dataset (gc_full.csv) has seven attributes, we provided a short description of these attributes in the ReadMe file. To learn more about this dataset, please refer to the git repository https://github.com/olcf/TitanGPULife and the related publication (https://ieeexplore.ieee.org/abstract/document/9355319).

42 ENGINEERING↗

Enhanced Component Performance Study: Emergency Diesel Generators 1998-2020

This report presents an enhanced performance evaluation of emergency power system (EPS) and high-pressure core spray (HPCS) emergency diesel generators (EDGs) at U.S. commercial nuclear power plants. This report evaluates component performance over time using (1) Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS) data from 1998 through 2020 and (2) maintenance unavailability performance data from Mitigating Systems Performance Index (MSPI) Basis Document data from 2002 through 2020. The objective is to show estimates of current failure probabilities and rates related to EDGs, trend these data on an annual basis, determine if the current data are consistent with the probability distributions currently recommended for use in NRC probabilistic risk assessments, show how the reliability data differ for different EDG manufacturers and for EDGs with different ratings; and summarize the subcomponents, causes, detection methods, and recovery associated with each EDG failure mode. The EDG failure modes considered are fail to start (FTS), fail to load and run (FTLR), and fail to run after one hour of operation (FTR>1H). Engineering analyses were performed with respect to time period and failure mode without regard to the actual number of EDGs at each plant. The factors analyzed are: subcomponent, failure cause, detection method, recovery, manufacturer, and EDG rating. The following increasing trends were identified for EDGs for the most recent 10-year period: • HPCS EDG FTS failure probability • EPS and HPCS EDG frequency of start demands (demands per reactor year) • EPS and HPCS EDG frequency of FTLR demands. The following decreasing trends were identified for EDGs for the most recent 10-year period: • EPS EDG FTS failure probability • EPS EDG FTLR failure probability • EPS EDG unavailability • EPS and HPCS EDG frequency of FTLR events (failures per reactor year).

99 GENERAL AND MISCELLANEOUS↗

Enhanced Component Performance Study: Emergency Diesel Generators 1998–2022

This report presents an enhanced performance evaluation of the emergency power system (EPS) and high-pressure core spray (HPCS) emergency diesel generators (EDGs) at U.S. commercial nuclear power plants. This report evaluates component performance over time using (1) Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS) data from 1998 through 2022 and (2) maintenance unavailability performance data from Mitigating Systems Performance Index (MSPI) Basis Document data from 2002 through 2022. The objective is to show estimates of current failure probabilities and rates related to EDGs, trend these data on an annual basis, determine if the current data are consistent with the probability distributions currently recommended for use in Nuclear Regulatory Commission (NRC) probabilistic risk assessments, show how the reliability data differ for different EDG manufacturers and for EDGs with different ratings; and summarize the subcomponents, causes, detection methods, and recovery associated with each EDG failure mode. The EDG failure modes considered are fail to start (FTS), fail to load and run (FTLR), and fail to run after one hour of operation (FTR>1H). Engineering analyses were performed with respect to time-period and failure mode without regard to the actual number of EDGs at each plant. The factors analyzed include subcomponent, failure cause, detection method, recovery, manufacturer, and EDG rating. The following increasing trends were identified for EDGs for the most recent 10-year period: (1) HPCS EDG FTS failure probability, (2) EPS and HPCS EDG frequency of start demands (demands per reactor year), and (3) EPS and HPCS EDG frequency of FTLR demands. The following decreasing trends were identified for EDGs for the most recent 10-year period: (1) EPS EDG FTS failure probability, (2) EPS EDG FTLR failure probability, (3) EPS EDG unavailability, and (4) EPS and HPCS EDG frequency of FTLR events (failures per reactor year).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Enhanced Component Performance Study: Emergency Diesel Generators 1998-2024

This report presents an enhanced performance evaluation of the emergency power system (EPS) and high-pressure core spray (HPCS) emergency diesel generators (EDGs) at U.S. commercial nuclear power plants. This report evaluates component performance over time using (1) Institute of Nuclear Power Operations (INPO) Industry Reporting and Information System (IRIS) data from 1998 through 2024 and (2) maintenance unavailability performance data from Mitigating Systems Performance Index (MSPI) Basis Document data from 2002 through 2024. The objective is to show estimates of current failure probabilities and rates related to EDGs, trend these data on an annual basis, determine if the current data are consistent with the probability distributions currently recommended for use in Nuclear Regulatory Commission (NRC) probabilistic risk assessments, show how the reliability data differ for different EDG manufacturers and for EDGs with different ratings; and summarize the subcomponents, causes, detection methods, and recovery associated with each EDG failure mode. The EDG failure modes considered are fail to start (FTS), fail to load and run (FTLR), and fail to run after one hour of operation (FTR>1H). Engineering analyses were performed with respect to time-period and failure mode without regard to the actual number of EDGs at each plant. The factors analyzed include subcomponent, failure cause, detection method, recovery, manufacturer, and EDG rating. The following increasing trends were identified for EDGs for the most recent 10-year period: • EPS and HPCS EDG frequency of start demands (demands per reactor year) • EPS and HPCS EDG frequency of FTLR demands • EPS and HPCS EDG frequency of run>1H hours. The following decreasing trends were identified for EDGs for the most recent 10-year period: • EPS EDG FTR>1H failure rate • EPS EDG unreliability • EPS and HPCS EDG frequency of FTR>1H events (failures per reactor year).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Modeling Framework for Bulk Electric Grid Impacts from HEMP E1 and E3 Effects (Tasks 3.1 Final Report)

This report presents a framework to evaluate the impact of a high-altitude electromagnetic pulse (HEMP) event on a bulk electric power grid. This report limits itself to modeling the impact of EMP E1 and E3 components. The co-simulation of E1 and E3 is presented in detail, and the focus of the paper is on the framework rather than actual results. This approach is highly conservative as E1 and E3 are not maximized with the same event characteristics and may only slightly overlap. The actual results shown in this report are based on a synthetic grid with synthetic data and a limited exemplary EMP model. The framework presented can be leveraged and used to analyze the impact of other threat scenarios, both manmade and natural disasters. This report d escribes a Monte-Carlo based methodology to probabilistically quantify the transient response of the power grid to a HEMP event. The approach uses multiple fundamental steps to characterize the system response to HEMP events, focused on the E1 and E3 components of the event. 1) Obtain component failure data related to HEMP events testing of components and creating component failure models. Use the component failure model to create component failure conditional probability density function (PDF) that is a function of the HEMP induced terminal voltage. 2) Model HEMP scenarios and calculate the E1 coupled voltage profiles seen by all system components. Model the same HEMP scenarios and calculate the transformer reactive power consumption profiles due to E3. 3) Sample each component failure PDF to determine which grid components will fail, due to the E1 voltage spike, for each scenario. 4) Perform dynamic simulations that incorporate the predicted component failures from E1 and reactive power consumption at each transformer affected by E3. These simulations allow for secondary transients to affect the relays/protection remaining in service which can lead to cascading outages. 5) Identify the locations and amount of load lost for each scenario through grid dynamic simulation. This can be an indication of the immediate grid impacts from a HEMP event. In addition, perform more detailed analysis to determine critical nodes and system trends. 6) To help realize the longer-term impacts, a security constrained alternating current optimal power flow (ACOPF) is run to maximize critical load served. This report describes a modeling framework to assess the systemic grid impacts due to a HEMP event. This stochastic simulation framework generates a large amount of data for each Monte Carlo replication, including HEMP location and characteristics, relay and component failures, E3 GIC profiles, cascading dynamics including voltage and frequency over time, and final system state. This data can then be analyzed to identify trends, e.g., unique system behavior modes or critical components whose failure is more likely to cause serious systemic effects. The proposed analysis process is demonstrated on a representative system. In order to draw realistic conclusions of the impact of a HEMP event on the grid, a significant amount of work remains with respect to modeling the impact on various grid components.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Sequential Model Predictive and Deep Reinforcement Learning-Based Controller for Distribution System Outage Mitigation under Hurricane Events

This paper proposes a proactive outage mitigation framework for power distribution networks to withstand hurricane-induced disruptions. It leverages Model Predictive Control (MPC) to identify safe lines for proactive switching during hurricanes, minimizing the risk of cascading failures and voltage violations. The switching strategies optimized by MPC are sequentially integrated with a Deep Reinforcement Learning agent using the Advantage Actor-Critic algorithm, enabling dynamic line switching to maximize connected buses and minimize voltage violations in real time. Using a probabilistic hurricane model, the framework predicts line failures and adapts to varying conditions to enhance grid resilience. Simulations on the IEEE 123-bus system demonstrate its effectiveness in maintaining high connectivity and minimizing disruptions. Real-time testing with an RTDS confirms the practicality and reliability of the proposed approach.

Selim, Alaa [University of Connecticut]↗

Advanced Monitoring and Control in the ANL METL Facility Using an Engineering Digital Twin

The potential benefits of using an engineering digital twin to achieve greater autonomy for monitoring and control functions in advanced reactors was investigated for the Mechanisms Engineering Test Loop (METL) liquid sodium facility at Argonne National Laboratory. The METL sodium purification system served as a representative system as it requires significant human in-the-loop interaction to accomplish its design function. The objective was to demonstrate how real-time operation could be automated while preserving oversight of the operator for ensuring that the system design functions are met. A digital twin model of the purification system was developed for both the cold trap purification loop and plugging meter diagnostic loop using information from the METL piping and instrumentation diagram (P&ID). Automated monitoring and diagnosis of component degradation in the METL facility was demonstrated in tests using the PRO-AID health monitoring software with the digital twin model incorporated in the library of components. Component failures were introduced and were successfully diagnosed in real time. These tests serve to demonstrate an advanced monitoring capability able to differentiate sensor degradation from component degradation, to generate a rank ordering of probabilities of different failure mechanisms that serves to circumvent the false alarm problem with current anomaly detection methods, and how facility monitoring can be transformed from anomaly detection to identification of a specific fault. Automated control of the purification system was demonstrated through simulations that exercised a model predictive controller designed using the digital twin model. Results of these simulations compared favorably with experimental data showing very good reference tracking response with negligible overshoot. In conclusion, these pilot tests and simulations successfully demonstrated the use of a digital twin for improved automation of monitoring and control. It was shown how the digital twin enables switching between control modes from cold trap operation where impurities are removed to plugging meter operation where impurity concentrations are measured.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Molten Sodium Penetration in NaSICON Electrolytes at 0.1 A cm –2

High-conductivity solid electrolytes, such as the Na superionic conductor, NaSICON, are poised to play an increasingly important role in safe, reliable battery-based energy storage, enabling advanced sodium-based batteries. Coupled demands of increased current density (≥0.1 A cm –2 ) and low-temperature (<200 °C) operation, combined with increased discharge times for long-duration storage (>12 h), challenge the limitations of solid electrolytes. Here, we explore the penetration of molten sodium into NaSICON at high current densities. Previous studies of β"-alumina proposed that Poiseuille pressure-driven cracking (mode I) and recombination of ions and electrons within the solid electrolyte (mode II) are the two main mechanisms for Na penetration, but a comprehensive study of Na penetration in NaSICON is necessary, particularly at high current density. To further understand these modes, this work employs unidirectional galvanostatic testing of Na|NaSICON|Na symmetric cells at 0.1 A cm –2 over 23 h at 110 °C. Further, while galvanostatic testing shows a relatively constant yet increasingly noisy voltage profile, electrochemical impedance spectroscopy (EIS) reveals a significant decrease in cell impedance correlated with significant sodium penetration, as observed in scanning electron microscopy (SEM). Further SEM analysis of sodium accumulation within NaSICON suggests that mode II failure may be far more prevalent than previously considered. Further, these findings suggest that total (dis)charge density (mAh cm –2 ), as opposed to current density (mA cm –2 ), may be a more critical parameter when examining solid electrolyte failure, highlighting the challenge of achieving long discharge times in batteries using solid electrolytes. Together, these results provide a better understanding of the limitations of NaSICON solid electrolytes under high current and emphasize the need for improved electrode–electrolyte interfaces.

25 ENERGY STORAGE↗

Electrochemical Response of Alkaline Batteries Subject to Quasi-Static and Dynamic Loading

We report electrochemical changes were successfully monitored through the coupling of external loading, electrochemical impedance spectroscopy (EIS), and distribution of relaxation times (DRT) analysis. The development of the testing methods allows for detailed observation of changes due to mechanical loading and distinguishes responses between different cell geometries. Comparison of the force vs displacement, voltage vs displacement, and distribution of relaxation times plots to the different cell geometries display failure modes specific to geometry as well as the impact of different loading profiles. Numerical modeling confirmed the movement within individual cells and predicted locations with the most deformation based on the external loading condition applied. The results gathered from combining mechanical loading, electrochemical response, and numerical modeling, yield a viable approach to establishing an improved understanding of the effects of mechanical loading on the electrochemical response of multiple battery geometries and the methods herein may be extensible to additional battery chemistries.

25 ENERGY STORAGE↗