The Effects of Multipath on the Measurement of Antenna Time Delays
This paper describes the errors associated with measuring time delays of signals propagating through the primary path of a large Cassegrain antenna.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
This paper describes the errors associated with measuring time delays of signals propagating through the primary path of a large Cassegrain antenna.
Active control of rotor-induced vibration in rotorcraft has received significant attention recently. Two classes of techniques have been proposed. The more developed approach works with harmonic analysis of measured time histories and is called the frequency-domain approach. The more recent approach computes the control input directly using the measured time history data and is called the time-domain approach. The report summarizes the results of a theoretical investigation to compare the two approaches. Five specific areas were addressed: (1) techniques to derive models needed for control design (system identification methods), (2) robustness with respect to errors, (3) transient response, (4) susceptibility to noise, and (5) implementation difficulties. The system identification methods are more difficult for the time-domain models. The time-domain approach is more robust (e.g., has higher gain and phase margins) than the frequency-domain approach. It might thus be possible to avoid doing real-time system identification in the time-domain approach by storing models at a number of flight conditions. The most significant error source is the variation in open-loop vibrations caused by pilot inputs, maneuvers or gusts. The implementation requirements are similar except that the time-domain approach can be much simpler to implement if real-time system identification were not necessary.
Atmospheric muons are typically high energy, highly penetrating charged particles. They interact with matter primarily through multiple Coulomb scatterings. Muon scattering intensities can be used to characterize the density and atomic number of the matter that they pass through. Previously, the Los Alamos National Laboratory (LANL) muon tomography team performed muon imaging of the partially filled MC-10 spent nuclear fuel (SNF) cask at Idaho National Laboratory (INL). This experiment demonstrated the feasibility of muon imaging for the verification of spent fuel container contents. That original effort used the mini muon tracker array, consisting of two arrays of drift tubes on either side of the SNF cask. The reconstructed image quality was limited by statistics, largely due to low muon flux at high zenith angles. A LANL led team will perform new measurements with a larger array, the Giant Muon Tracker (GMT), to improve data collection rates and statistics. In this work, simulations were performed with the GMT near the partially filled INL MC-10 cask. For more general fuel diversion detection, a full MC-10 cask and casks with a singular missing fuel bundle were also simulated. To understand minimum measurement times needed for missing bundle identification, 100 000 to millions of tracked muons (corresponding to 1.4 days to several weeks measurement time) were analyzed. Simulated images were then analyzed visually and numerically to explore techniques designed to minimize the collection time needed to identify the diversion of fuel in each scenario.
This paper presents a preliminary demonstration of an automated health assessment tool, capable of real-time on-board operation using existing engine control hardware. The tool allows operators to discern how rapidly individual turboshaft engines are degrading. As the compressor erodes, performance is lost, and with it the ability to generate power. Thus, such a tool would provide an instant assessment of the engine s fitness to perform a mission, and would help to pinpoint any abnormal wear or performance anomalies before they became serious, thereby decreasing uncertainty and enabling improved maintenance scheduling. The research described in the paper utilized test stand data from a T700-GE-401 turboshaft engine that underwent sand-ingestion testing to scale a model-based compressor efficiency degradation estimation algorithm. This algorithm was then applied to real-time Health Usage and Monitoring System (HUMS) data from a T700-GE-701C to track compressor efficiency on-line. The approach uses an optimal estimator called a Kalman filter. The filter is designed to estimate the compressor efficiency using only data from the engine s sensors as input.
A system and methods for real-time model based vehicle structural anomaly detection are disclosed. A real-time measurement corresponding to a location on a vehicle structure during an operation of the vehicle is received, and the real-time measurement is compared to expected operation data for the location to provide a modeling error signal. A statistical significance of the modeling error signal to provide an error significance is calculated, and a persistence of the error significance is determined. A structural anomaly is indicated, if the persistence exceeds a persistence threshold value.
The Perseverance rover is currently collecting samples on the martian surface for potential return to Earth and planning is underway to develop facilities to study these samples. Perseverance will collect up to 38 samples that will be sealed in TiN tubes. As long as the tubes remain sealed the samples will be metastable. However, as soon as a tube is opened, or headspace gas is extracted these samples will begin to re-equilibrate with their new surroundings. The MSPG2 time-sensitive science sub-group attempted to quantify the rates at which alteration is likely to occur assuming the samples are opened and stored in a nitrogen atmosphere at room temperature. The group also recommended ~20 instruments for inclusion in a sample receiving facility to allow the time sensitive properties of these samples to be measured before they are irreversibly altered.
An operational characteristic of blowdown-type of wind tunnels is the drop in the stagnation temperature with time and the accompanying change in the test-section unit Reynolds number at constant stagnation pressure and Mach number. This apparent disadvantage can be turned to advantage in some cases where a Reynolds number scan is desired in order to study the effect of unit Reynolds number variation on a particular viscous flow phenomenon. This note presents such an instance arising from recent investigations on base pressure at transonic speeds conducted in the NAL 1-ft tunnel.
The test results indicate that the system performs within the specifications established. The overall system appears to be well designed and built to a good commercial grade. The triple redundant time code generators, whose outputs are majority voted, performed adequately as far as could be determined on an operational situation.
Time- and spectrally-resolved scanning near-field optical microscopy was applied to study spatial variations of photoluminescence (PL) spectra and carrier dynamics in polar InGaN/GaN single quantum wells (QWs) emitting from 410 nm to 570 nm. The main attention was devoted to variations of PL properties and carrier dynamics around V-defects. The PL intensity, peak wavelength, and linewidth, as well as the radiative and nonradiative recombination times, were found to be different in V-defect-rich and defect-free regions. The radiative lifetime close to the defects was longer up to several times, which is attributed to an increased electron and hole wave function separation in the QW plane. PL decay times, measured using excitation and collection through the near-field probe, were one to two orders of magnitude shorter than PL decay times measured in the far field. This shows that the near-field PL decay and the integrated PL intensity are primarily determined by the carrier out-diffusion from under the probe. Only in the immediate vicinity of the V-defects, the near-field PL decays due to the nonradiative recombination at dislocations. The area of such enhanced nonradiative recombination is limited to just a few percent of the total QW area. This shows that recombination via dislocations and V-defects does not play a decisive role in the overall nonradiative recombination and internal quantum efficiency of polar InGaN/GaN QWs.
Early-bird communication is a communication/computation overlap technique that leverages fine-grained communication to improve application run-time. Communication is divided such that each individual thread can initiate transmission of its portion of the data upon completion rather than waiting for a dedicated communication phase. The benefit of early-bird communication depends on the completion timing of the individual threads: On the one hand, if all threads are complete at nearly the same time, the overheads of sending multiple messages will accumulate, leading to performance that is worse than if a single message had been sent. On the other hand, if thread completions are spread out in time, those that complete earlier can send data while others continue working, leading to performance that is better than if a single message had been sent. The challenge is that the completion times are currently unknown and can vary based on application, problem size, system software, and underlying hardware. In this paper, we address this lacuna by measuring and evaluating the potential overlap afforded by early-bird communication for a selection of proxy applications. These measurements help us understand whether a given application could benefit from early-bird communication. Here, we present our technique for gathering this data and evaluate data collected from three proxy applications: MiniFE, MiniMD, and MiniQMC. Each application is run on three systems with distinct CPU architectures and strong scales across three run sizes. To characterize the behavior of these workloads, we study the trends of thread timings at both a macro level, across all threads across all runs of an application, and a micro level, that is, within a single process of a single run. We observe that our tested applications exhibit significantly different thread arrival distributions. The machine used had a significant impact, with the window of potential overlap varying by as much as an order of magnitude.
An operator workload measurement methodology is presented which will be used in support of the Mark IVA operational test and evaluation plan. Three operator workload measures are suggested: operator ratings, primary task work measures, and information processing time measures. A method of validating the workload measures using secondary task work measures is presented. It is expected that operations testing using these measures will assist in establishing the time required to perform essential operational activities and will indicate high risk operations areas due to potential operator overload.
Distribution System State Estimation (DSSE) is frequently constrained by limited real-time measurements, the uncertainties introduced by distributed energy resources, and the presence of bad data. To address them, this paper proposes an enhanced Multi-Fidelity Bayesian Neural Network (MFBNN) DSSE approach. A low-fidelity layer based on a Deep Neural Network (DNN) is first pre-trained on pseudo-measurement data to learn fundamental state features. Subsequently, a high-fidelity Bayesian Neural Network (BNN) layer leverages limited but high-quality real-time measurements to refine these features, thereby achieving accurate DSSE. Additionally, the deep SHapley Additive exPlanation (SHAP) is developed to quantify the influence of measurement data on DSSE through dual perspectives of global feature importance and local nodal contributions, establishing a hierarchical explainability framework for machine learning-based DSSE. Comparative studies conducted on the IEEE 13-bus system and a real-world 2135-node system from Dominion Energy demonstrate that the proposed method excels in estimation accuracy, even under situations of high noise levels, bad data, and missing data. Further comparisons with Weighted Least Squares (WLS) and other machine learning-based DSSE approaches verify that the proposed framework offers higher accuracy, improved interpretability, and enhanced robustness.
Long path Differential Optical Absorption Spectroscopy (DOAS) using a picosecond UV laser as a light source was developed in our institute. Tropospheric OH radicals are measured by their rotational absorption lines around 308 nm. The spectra are obtained using a high resolution spectrograph. The detection system has been improved over the formerly used optomechanical scanning device by application of a photodiode array which increased the observed spectral range by a factor of 6 and which utilizes the light much more effectively leading to a considerable reduction of the measurement time. This technique provides direct measurements of OH because the signal is given by the product of the absorption coefficient and the OH concentration along the light path according to Lambert-Beers law. No calibration is needed. Since the integrated absorption coefficient is well known the accuracy of the measurement essentially depends on the extent to which the OH absorption pattern can be detected in the spectra. No interference by self generated OH radicals in the detection lightpath has been observed. The large bandwidth (greater than 0.15 nm) and the high spectral resolution (1.5 pm) allows absolute determination of interferences by other trace gas absorptions. The measurement error is directly accessible from the absorption-signal to baseline-noise ratio in the spectra. The applicability of the method strongly depends on visibility. Elevated concentrations of aerosols lead to considerable attenuation of the laser light which reduces the S/N-ratio. In the moderately polluted air of Julich, where we performed a number of OH measurement spectra. In addition absorption features of unidentified species were frequently detected. A quantitative deconvolution even of the known species is not easy to achieve and can leave residual structures in the spectra. Thus interferences usually increase the noise and deteriorate the OH detection sensitivity. Using diode arrays for sensitive absorption measurements some specific problems of those detectors have to be solved experimentally (i.e. fixed pattern noise, dark signal noise, nonuniform efficiency of individual elements, spatial sensitivity variations). In order to improve the low spatial resolution we performed laboratory studies using a multiple reflection cell to convert the long path technique to a real in situ point measurement. Under the conditions of field experiments in Julich residual absorbance signals at present are about 1.5x10(exp -4) corresponding to an OH detection sensitivity of 2x10(exp 6) OH/cm(exp 3) using a light path of 5.8 km. Total integration times for one measurement point vary between a few minutes and an hour.
The transient charging and photon emission from the vacuum chamber testing of the Cooperative High Altitude Rocket Gun Experiment are studied. Graphs of the mother-daughter voltage versus time and high time resolution data related to the return current to the vehicle are examined. It is observed that for average sounding rocket densities of 10 to the -6th torr the slope of the voltage rise of the rocket begins to flatten 40 microsec after the onset of electron beam emission, and for higher gas pressure the rocket reaches a maximum voltage of 25 or 30 microsec after the onset of electron beam emission. The data reveal that the return current mechanism for the higher gas pressure is through the sheath.
Explore the source record for details and available documents.
This work investigates a 4 He-detector active interrogation system that leverages neutron spectroscopy to classify nuclear waste streams. MCNP models tested the concept through the simulation of a D-D neutron generator, an array of 4 He detectors, and various waste compositions. The fast-neutron Differential Die-Away signature was augmented with a neutron-energy discrimination signature. This signature isolates induced fission neutrons, the energy of which is greater than that of the D-D monoenergetic spectrum. With the incorporation of this spectroscopic technique, the measurement time decreased by 3–9% (depending on the degree of neutron moderation and absorption presented by the sample), demonstrating how neutron spectroscopy can enhance active interrogation methods. The reduced measurement times would have significant financial and logistical benefits for facilities with large footprints of low-level waste production.
A multiphased research program to obtain detailed flow characteristics on a multielement high-lift flap system is being conducted on the Transport Systems Research Vehicle (B737-100 aircraft) at NASA Langley Research Center. Upcoming flight tests have required the development of a highly capable and flexible flight measurement and data analysis instrumentation system. This instrumentation system will be more comprehensive than any of the systems used on previous high-lift flight experiment at NASA Langley. The system will provide the researcher near-real-time information for decision making needed to modify a flight test in order to further examine unexpected flow conditions. This paper presents the research requirements and instrumentation design concept for an upcoming flight experiment for the subsonic transport high-lift research program. The flight experiment objectives, the measurement requirements, the data acquisition system, and the onboard data analysis and display capabilities are described.