Coupled Reactor and Engine Nuclear Thermal Propulsion Modeling Methodology

The design and development process of a Nuclear Thermal Propulsion (NTP) system requires extensive multiphysics modeling to couple the neutron physics and thermal feedback effects to determine the reactor’s power shape. Propulsion system performance codes utilize this power shape to determine NTP key performance parameters. While the power shape is heavily dependent on the temperature profile and geometry of the reactor, many analyses either assume a constant power shape, or use neutronics analysis to determine a power shape for a specific reactor configuration. The development of a coupling interface for a propulsion system performance code and a Monte Carlo neutron transport code (OpenMC) allows for the reactor power shape to be calculated in an iteration loop. The interface utilizes a file share system to transfer geometry dimensions, temperatures, and material identifiers to OpenMC, which is used to perform a neutron transport simulation of a design like the government Testing Reference Design reactor. The interface is then able to post-process the results from OpenMC and use the same file share system to share a power shape and other important neutron transport parameters to the system performance code. Initial results show that neglecting the changes to power shape when comparing reactor configurations can yield inaccurate results. Furthermore, utilizing propellants other than hydrogen gas can cause significant changes to the power shape, and thus, the thermal performance of a specific reactor design. This methodology is being expanded to allow for multiple families of NTP reactors to be analyzed, including block moderator, particle bed, and NERVA-derived reactors.

multiphysics coupling↗

Updates to PATO’s Thermo-Mechanical Model

The solid mechanics module within the Porous material Analysis Toolbox (PATO) material response code was updated to model the stress contribution from both internal pressure and pyrolysis shrinkage as function of material’s decomposition. Incorporating these physical phenomena, alongside the previously included temperature dependent mechanical properties, thermal expansion, and aerodynamic loads, allows for a more accurate thermo-mechanical behavior modeling of Thermal Protection System (TPS) materials, which is critical to assess spallation risks during atmospheric entry. This poster outlines the workflow for obtaining the necessary PATO inputs, derived from dilatometry experiments, which are used to model the stress field in TPS materials due to thermal expansion and pyrolysis shrinkage. Furthermore, to analyze the relevance of the stress contribution from the internal pressure, a study was conducted using TACOT with different permeability values.

TPS↗

Coupled Reactor and Engine Nuclear Thermal Propulsion Modeling Methodology

The design and development process of a Nuclear Thermal Propulsion (NTP) system requires extensive multiphysics modeling to couple the neutron physics and thermal feedback effects to determine the reactor’s power shape. Propulsion system performance codes utilize this power shape to determine NTP key performance parameters. While the power shape is heavily dependent on the temperature profile and geometry of the reactor, many analyses either assume a constant power shape, or use neutronics analysis to determine a power shape for a specific reactor configuration. The development of a coupling interface for a propulsion system performance code and a Monte Carlo neutron transport code (OpenMC) allows for the reactor power shape to be calculated in a Picard iteration.

Jacob Stonehill↗

Identification and Study of Validation Level Test Cases for Computational Modeling of Non-Charring Ablators

Computational modeling of Thermal Protection System (TPS) materials, used for aerospace applications, provides numerous advantages in preliminary selection and design of a heatshield material and shape for atmospheric entry vehicles. However, to serve as a reliable tool for prediction of material thermal and ablative behavior, the modeling approach needs to be validated against real experimental and flight data, preferably at a range of applied conditions. The validation study is typically very complex as it requires reliable measured data not only for the material thermal response and surface recession, but also well characterized environmental conditions. The validation problem becomes even more complex when the material thermal response is dictated by multi-physics effects such as solid conduction, in-depth thermal decomposition, pyrolysis gas flow and chemical reactions. The multi-physics effects complicate not only the modeling effort, but also the experimental measurement for validation of various aspects of the highly coupled problem. In this study, an attempt is made to identify suitable experimental data that could serve as a source for validation of material thermal response modeling tools. To reduce the computational complexity, this study focuses only on non-charring ablators, where the material thermal response could be modeled with a single governing equation for solid conduction and the ablation is limited only to the surface of the material. With a well characterized and publicly available experimental data being sparse, the study is limited in presenting test cases for only three materials: camphor, graphite and FiberForm® in the sequence of increased modeling complexity. Graphite is a commonly used TPS material for aerospace applications, both for leading edges of high-speed vehicles and internal insulation of solid rocket motors. FiberForm® is a porous carbon pre-form used in preparation of the well known PICA material Tran et al. [1996]. Inclusion of camphor into the list is conditioned with the relative simplicity in modeling the material thermal and chemical response and the low-enthalpy flow environment. In addition, camphor has been used as a simple test material for study of flow transition behavior by Stock and Ginoux [1973] and assessment of a heatshield shape change at flight relevant conditions by Rotondi et al. [2022]. In this work, the identified experimental data was extracted from the public literature and test cases that yet have been published. As it was found from the review, not a single test case contains an exhaustive set of data that would validate every aspect of the material physics. However, in the data collected, various aspects of the material behavior can be still validated, such as surface and in-depth temperature, amount of recession and a shape change. The identified experimental data for each case is accompanied with a characterized flow environment and simulated boundary conditions predicted by a Data-Parallel Line Relaxation (DPLR) code Wright et al. [1998]. In addition, material thermal response numerical simulations in each test case are performed with Kentucky Aerothermodynamics and Thermal Response System (KATS-MR) Zibitsker et al. [2022] providing a comparative study and a sanity check for the proposed validation data. Sample results from the performed numerical study are shown below. Figure 1 shows distribution of surface heat flux and pressure values on a hemi-cylinder model made of FiberForm® and tested in HyMETS arc-jet facility. The results are shown for the high pressure condition among the two tests. Flow simulation was performed with DPLR code on a quarter of original geometry. In the figure, the quarter shape was mirrored across zx and xy planes to show the complete distribution. Figure 2 shows the material response results for the high pressure case (7500 Pa), simulated with KATS-MR and a comparison to the experimental data for the surface temperature and shape shape. The simulation was performed on a 2-D slice, extracted in the xy plane at the middle of the sample. Figure 3 shows the material response simulation for the low pressure case (3500 Pa) and a comparison to the experimental data for surface temperature and shape change.

ablation↗

Isothermal Versus Sensible Cold Storage: A Model-Based Performance Comparison for Pumped Thermal Electricity Storage

Pumped-thermal energy storage (PTES) systems consume and produce electrical energy using thermal storage media as an intermediate stage. PTES lends itself to long-duration energy storage to facilitate high penetration of intermittent electricity generation. This study presents a model-based comparison of two thermal storage types within a PTES system: a conventional, single-phase, stratified water-glycol sensible storage system (SGS), and an ideal isothermal, two-phase heat exchanger that freezes a water reservoir (isothermal heat exchanger (IHEX)). The SGS thermal storage capacity is based on the liquid’s sensible heat change with temperature, whereas the capacity of the IHEX is based on the latent heat of isothermally freezing and melting water. The idealized IHEX modeled here undergoes steady-state melting and freezing (in contrast to transient rates, as observed with ice-on-coil storage). A computational model of a complete PTES system is presented and used to evaluate the PTES system-level performance with each type of cold storage. Compared to SGS-based PTES, under nominal operating conditions, the IHEX-based PTES increased electrical round-trip efficiency from 61% to 82% and increased energy density from 1.13 to 8.09 kWh/m 3 In conclusion, the performance of the PTES configured with IHEX storage was also analyzed under varying operating parameters.

25 ENERGY STORAGE↗

Thermal protection optimization for the space shuttle.

This paper discusses optimal entry trajectories for the space shuttle that minimize the weight of an entry thermal protection system. The analysis was made using mathematical models of two types of thermal protection systems that were under consideration for the space shuttle: a metallic thermal protection system, and a reusable surface insulation thermal protection system. Optimal entries were generated using maximum orbiter nose temperature as a parameter. Thermal protection system weights were computed for both fixed and variable angles of attack using three-dimensional entry trajectories. Results indicated that variable angle-of-attack entries require less thermal protection system weight than entries at a constant angle of attack (35 deg) for both systems considered. Results also showed that 95 to 99 per cent of the thermal protection system weight requirement resulted from flight regimes in which the flow was still laminar.

Garcia, F., Jr.↗

Validation and Sensitivity Analyses of Arc-Jet Performance of Woven Thermal Protection Entry Systems

A material response model is developed for the determination of erosion rates and thermal response of woven materials to enable accurate thermal protection material sizing and future missions to Venus and giant planets. The stagnation-point thermal response is further evaluated using a Monte Carlo global sensitivity analysis to determine the interactions between key parameters in the material surface energy balance, such as, convective blowing correction parameter and weave material properties including isotropic and orthotropic thermal conductivites. The time-accurate material response for the dual layer weave erosion and surface temperatures show excellent agreement with stagnation flat face arc-jet tests involving time-varying aeroheating-cooling cycles. The high-fidelity Monte Carlo sensitivity analysis technique was used to address challenges in thermal protection sizing for the Adaptive Deployable Entry and Placement Technology (ADEPT) system, a low ballistic coefficient hypersonic decelerator. The results represent new correlations for such weaves involving Carbon-air oxidation equilibrium chemistry. Through the multi-variate regression analyses and uncertainty rankings performed, only three properties were found to contribute to the transient thermal response of the gore, with emissivity contributing to nearly 95% of the total output uncertainty.

Pratibha Raghunandan↗

Validation and Sensitivity Analyses of Arc-Jet Performance of Woven Thermal Protection Entry Systems

A material response model is developed for the determination of erosion rates and thermal response of woven materials to enable accurate thermal protection material sizing and future missions to Venus and giant planets. The stagnation-point thermal response is further evaluated using a Monte Carlo global sensitivity analysis to determine the interactions between key parameters in the material surface energy balance, such as, convective blowing correction parameter and weave material properties including isotropic and orthotropic thermal conductivites. The time-accurate material response for the dual layer weave erosion and surface temperatures show excellent agreement with stagnation flat face arc-jet tests involving time-varying aeroheating-cooling cycles. The high-fidelity Monte Carlo sensitivity analysis technique was used to address challenges in thermal protection sizing for the Adaptive Deployable Entry and Placement Technology (ADEPT) system, a low ballistic coefficient hypersonic decelerator. The results represent new correlations for such weaves involving Carbon-air oxidation equilibrium chemistry. Through the multi-variate regression analyses and uncertainty rankings performed, only three properties were found to contribute to the transient thermal response of the gore, with emissivity contributing to nearly 95% of the total output uncertainty.

Pratibha Raghunandan↗

Temporal Forecasting of Distributed Temperature Sensing in a Thermal Hydraulic System With Machine Learning and Statistical Models

We benchmark performance of long-short term memory (LSTM) network machine learning model and autoregressive integrated moving average (ARIMA) statistical model in temporal forecasting of distributed temperature sensing (DTS). Data in this study consists of fluid temperature transient measured with two co-located Rayleigh scattering fiber optic sensors (FOS) in a forced convection mixing zone of a thermal tee. We treat each gauge of a FOS as an independent temperature sensor. We first study prediction of DTS time series using Vanilla LSTM and ARIMA models trained on prior history of the same FOS that is used for testing. The results yield maximum absolute percentage error (MaxAPE) and root mean squared percentage error (RMSPE) of 1.58% and 0.06% for ARIMA, and 3.14% and 0.44% for LSTM, respectively. Next, we investigate zero-shot forecasting (ZSF) with LSTM and ARIMA trained on history of the co-located FOS only, which is advantageous when limited training data is available. The ZSF MaxAPE and RMSPE values for ARIMA are comparable to those of the Vanilla use case, while the error values for LSTM increase. We show that in ZSF, performance of LSTM network can be improved by training on most correlated gauges between the two FOS, which are identified by calculating the Pearson correlation coefficient. The improved ZSF MaxAPE and RMSPE for LSTM are 4.4% and 0.33%, respectively. Performance of ZSF LSTM can be further enhanced through transfer learning (TL), where LSTM is re-trained on a subset of the FOS that is the target of forecasting. We show that LSTM pre-trained on correlated dataset and re-trained on 30% of testing target dataset achieves MaxAPE and RMSPE values of 2.32% and 0.28%, respectively.

ARIMA↗

Thermal protection system gap heating rates of the Rockwell International flat plate heat transfer model (OH2A/OH2B)

Heat transfer data for the Rockwell International Flat Plate Thermocouple Model are presented. The model simulated the Space Shuttle Vehicle Thermal Protection System. Data were recorded for locations in and around various size gaps for various gap orientation configurations. The test was conducted at Mach 5.1 for free-stream Reynolds number per foot values from 500,000 to 1,500,000.

Foster, T. F.↗

A System-Level Model for Estimating Residual Strain and Life of Nuclear Reactor Coolant System Components Under Connected-System-Thermal–Mechanical Boundary Conditions

Background: Environmental-assisted fatigue (EAF) is a major issue for the long-term survival of nuclear power plant fleets in the U.S. and worldwide. Multi-material welded regions (e.g., nozzles) and other high-stress regions of reactor coolant system (RCS) components are prone to EAF-related damage. Objective: The discussed work describes a system-level finite element (FE) model of RCS components of a pressurized water reactor (PWR). This is with the goal of predicting the stress hotspots, strain residuals, strain amplitudes and the resulting fatigue lives. Methods: Herein, the FE model was developed considering system-level loading conditions (under connected system thermal-mechanical boundary conditions). Thermal-mechanical stress analysis was performed considering thermal stratification and a design-basis reactor loading cycle. Based on the FE model results, the strain residuals, strain amplitudes and resulting fatigue lives of RCS components were predicted. Results: The results show that some of the RCS components can have significantly different strain amplitudes, residual strain, and fatigue lives, despite having similar geometry and material. Higher residual strain can lead to accelerated cyclic hardening of material and the associated effect of EAF. The simulated component-level strain profile (under realistic multi-axial-multi-physics loading cycle) can guide the selection of appropriate test inputs for conducting laboratory-scale EAF tests, which is a focus of future works. Conclusions: Despite similar geometry and material the RCS component can have significantly different strain profiles and resulting fatigue lives. The discussed approach can help to identify and prioritize the RCS components for conducting expensive nondestructive evaluation (NDE) inspections.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Thermal Analysis of the Advanced Technology Large Aperture Space Telescope (ATLAST) 8 Meter Primary Mirror

The Advanced Technology Large Aperture Space Telescope (ATLAST) preliminary design concept consists of an 8 meter diameter monolithic primary mirror enclosed in an insulated, optical tube with stray light baffles and a sunshade. ATLAST will be placed in orbit about the Sun-Earth L2 and will experience constant exposure to the sun. The insulation on the optical tube and sunshade serve to cold bias the telescope which helps to minimize thermal gradients. The primary mirror will be maintained at 280K with an active thermal control system. The geometric model of the primary mirror, optical tube, sun baffles, and sunshade was developed using Thermal Desktop(R) SINDA/FLUINT(R) was used for the thermal analysis and the radiation environment was analyzed using RADCAD(R). A XX node model was executed in order to characterize the static performance and thermal stability of the mirror during maneuvers. This is important because long exposure observations, such as extra-solar terrestrial planet finding and characterization, require a very stable observatory wave front. Steady state thermal analyses served to predict mirror temperatures for several different sun angles. Transient analyses were performed in order to predict thermal time constant of the primary mirror for a 20 degree slew or 30 degree roll maneuver. This paper describes the thermal model and provides details of the geometry, thermo-optical properties, and the environment which influences the thermal performance. All assumptions that were used in the analysis are also documented. Parametric analyses are summarized for design parameters including primary mirror coatings and sunshade configuration. Estimates of mirror heater power requirements are reported. The thermal model demonstrates results for the primary mirror heated from the back side and edges using a heater system with multiple independently controlled zones.

Hornsby, Linda↗

Analysis of Hypervelocity-Impacted Thin Films for Space Applications

Exposure to the harsh space environment and hypervelocity impacts from micrometeoroids and small orbital debris can affect space operations through long-term degradation of spacecraft materials, surfaces, or systems. Multi-layer insulation (MLI) and coated, polyimide films are spacecraft materials commonly found on the external surfaces of spacecraft for thermal control and protection. Characterizing the damage to these exposed materials with in situ and laboratory measurements can better inform spacecraft designers and operators in understanding and mitigating surface or system degradation. In this paper, we examine flown Hubble Space Telescope (HST) Equipment Bay 5 MLI and coated, polyimide ground test articles to characterize hypervelocity impact damage. Impact feature cavities are inspected to identify damage, which can validate long-term degradation models, improve thermal management systems, or improve accuracy of damage predictions. An overview of the impact characterization using optical microscopy, narrowband spectroscopy, and Scanning Election Microscopy/Energy Dispersive X- ray (SEM/EDX) of the two materials is presented. Observations of robustness in the space environment, as well as a detailed assessment of cratering and penetration statistics for the space-exposed sample, also are discussed.

Melissa A. Ward↗

Performance of a Haynes 188 metallic standoff thermal protection system at Mach 7

A flight weight, metallic thermal protection system (TPS) model applicable to reentry and hypersonic vehicles was subjected to multiple cycles of both radiant and aerothermal heating to evaluate its aerothermal performance and structural integrity. The TPS was designed for a maximum operating temperature of 1255 K and featured a shingled, corrugation stiffened corrugated skin heat shield of Haynes 188, a cobalt base alloy. The model was subjected to 3 radiant preheat/aerothermal tests for a total of 67 seconds and to 15 radiant heating tests for a total of 85.9 minutes at 1255 K. The TPS limited the primary structure to temperatures below 430 K in all tests. No catastrophic failures occurred in the heat shields, supports, or insulation system. The TPS continued to function even after exposure to a differential temperature 4 times the design value produced thermal buckles in the outer skin. The shingled thermal expansion joint effectively allowed for thermal expansion of the heat shield without allowing any appreciable hot gas flow into the model cavity, even though the overlap gap between shields increased after several thermal cycles.

Avery, D. E.↗

Analysis of Hypervelocity-Impacted Thin Films for Space Applications

Exposure to the harsh space environment and hypervelocity impacts from micrometeoroids and small orbital debris can affect space operations through long-term degradation of spacecraft materials, surfaces, or systems. Multi-layer insulation (MLI) and coated polyimide films are space-craft materials commonly found on the external surfaces of spacecraft for thermal control and protection. Characterizing the damage to these exposed materials with in-situ and laboratory measurements can better inform spacecraft designers and operators in understanding and mitigating surface or system degradation. In this paper, we examine flown Hubble Space Telescope (HST) Electronic Bay 5 MLI and coated polyimide ground test articles to characterize hyper-velocity impact damage. Impact feature cavities are inspected to identify damage, which can validate long-term degradation models, improve thermal management systems, or improve accuracy of damage predictions. An overview of the impact characterization using optical microscopy, narrow-band spectroscopy, and scanning election microscopy/energy dispersive x-ray (SEM/EDX) of the two materials is presented. Observations of robustness in the space environment, as well as a detailed assessment of cratering and penetration statistics for the space-exposed sample, also are discussed.

Melissa A Ward↗

Quantitative Diagnosis of Continuous-Valued, Stead-State Systems

Quantitative diagnosis involves numerically estimating the values of unobservable parameters that best explain the observed parameter values. We consider quantitative diagnosis for continuous, lumped- parameter, steady-state physical systems because such models are easy to construct and the diagnosis problem is considerably simpler than that for corresponding dynamic models. To further tackle the difficulties of numerically inverting a simulation model to compute a diagnosis, we propose to decompose a physical system model in terms of feedback loops. This decomposition reduces the dimension of the problem and consequently decreases the diagnosis search space. We illustrate this approach on a model of thermal control system studied in earlier research.

Quantitative Diagnosis↗

Effect of Adding a Regenerator to Kornhauser's MIT "Two-Space" (Gas-Spring+Heat Exchanger) Test Rig

This study employed entropy-based second law post-processing analysis to characterize the various thermodynamic losses inside a 3-space solution domain (gas spring+heat exchanger+regenerator) operating under conditions of oscillating pressure and oscillating flow. The 3- space solution domain is adapted from the 2-space solution domain (gas spring+heat exchanger) in Kornhauser's MIT test rig by modifying the heat exchanger space to include a porous regenerator system. A thermal nonequilibrium model which assumes that the regenerator porous matrix and gas average temperatures can differ by several degrees at a given axial location and time during the cycle is employed. An important and primary objective of this study is the development and application of a thermodynamic loss post-processor to characterize the major thermodynamic losses inside the 3-space model. It is anticipated that the experience gained from thermodynamic loss analysis of the simple 3-space model can be extrapolated to more complex systems like the Stirling engine. It is hoped that successful development of loss post-processors will facilitate the improvement of the optimization capability of Stirling engine analysis codes through better understanding of the heat transfer and power losses. It is also anticipated that the incorporation of a successful thermal nonequilibrium model of the regenerator in Stirling engine CFD analysis codes, will improve our ability to accurately model Stirling regenerators relative to current multidimensional thermal-equilibrium porous media models.

Ebiana, Asuquo B.↗

Aerospace applications of SINDA/FLUINT at the Johnson Space Center

SINDA/FLUINT has been found to be a versatile code for modeling aerospace systems involving single or two-phase fluid flow and all modes of heat transfer. Several applications of SINDA/FLUINT are described in this paper. SINDA/FLUINT is being used extensively to model the single phase water loops and the two-phase ammonia loops of the Space Station Freedom active thermal control system (ATCS). These models range from large integrated system models with multiple submodels to very detailed subsystem models. An integrated Space Station ATCS model has been created with ten submodels representing five water loops, three ammonia loops, a Freon loop and a thermal submodel representing the air loop. The model, which has approximately 800 FLUINT lumps and 300 thermal nodes, is used to determine the interaction between the multiple fluid loops which comprise the Space Station ATCS. Several detailed models of the flow-through radiator subsystem of the Space Station ATCS have been developed. One model, which has approximately 70 FLUINT lumps and 340 thermal nodes, provides a representation of the ATCS low temperature radiator array with two fluid loops connected only by conduction through the radiator face sheet. The detailed models are used to determine parameters such as radiator fluid return temperature, fin efficiency, flow distribution and total heat rejection for the baseline design as well as proposed alternate designs. SINDA/FLUINT has also been used as a design tool for several systems using pressurized gasses. One model examined the pressurization and depressurization of the Space Station airlock under a variety of operating conditions including convection with the side walls and internal cooling. Another model predicted the performance of a new generation of manned maneuvering units. This model included high pressure gas depressurization, internal heat transfer and supersonic thruster equations. The results of both models were used to size components, such as the heaters and gas bottles and also to point to areas where hardware testing was needed.

Ewert, Michael K.↗