Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “thermal flexibility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Energy performance of an operational government building retrofitted with ceiling phase change material tiles in a mixed-humid climate

The aging U.S. building stock requires various retrofit measures to enhance their energy efficiency. Here, this study explores the integration of thermal energy storage and advanced building controls as viable retrofit solutions for load flexibility and peak demand response while maintaining the occupants' comfort. A detailed assessment is conducted on the energy use of an administrative building in Sumner County, Kansas, focusing on the implementation of phase change materials (PCMs) in the ceiling of occupied zones. First, a time-resolved, whole-building energy model is developed in EnergyPlus, incorporating complex thermal behaviors such as air exchange between the plenum space and occupied zones, envelope leakage, and operational schedules. The model is then validated using experimental field test data, and subsequently a parametric assessment of key PCM properties and application strategies is performed to evaluate cooling electricity demand benefits. The parametric study shows that the optimal retrofit strategy, comprising a PCM with 23°C peak melting temperature, 0.125 in. (3.17 mm) thickness, and 150 kJ/kg latent heat, combined with active controls that include 8 h of precooling, forced convection under the ceiling, and a 2°C thermostat setback during peak hours, can result in a maximum load shift during the peak period of 99.6 % and the total electricity savings during the peak period of 98.9 % for the optimum case and thus provide significant cost savings under time-of-use pricing scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Additive‐Free Aqueous MXene Inks for Thermal Inkjet Printing on Textiles

Abstract Direct printing of functional inks onto flexible substrates allows for scalable fabrication of wearable electronics. However, existing ink formulations for inkjet printing require toxic solvents and additives, which make device fabrication more complex, limit substrate compatibility, and hinder device performance. Even water‐based carbon or metal nanoparticle inks require supplemental surfactants, binders, and cosolvents to produce jettable colloidal suspensions. Here, a general approach is demonstrated for formulating conductive inkjet printable, additive‐free aqueous Ti 3 C 2 T x MXene inks for direct printing on various substrates. The rheological properties of the MXene inks are tuned by controlling the Ti 3 C 2 T x flake size and concentration. Ti 3 C 2 T x ‐based electrical conduits and microsupercapacitors (MSCs) are printed on textile and paper substrates by optimizing the nozzle geometry for high‐resolution inkjet printing. The chemical stability and electrical properties of the printed devices are also studied after storing the devices for six months under ambient conditions. Current collector‐free, textile‐based MSCs show areal capacitance values up to 294 mF cm −2 (2 mV s −1 ) in poly(vinyl alcohol)/sulfuric acid gel electrolyte, surpassing reported printed MXene‐based MSCs and inkjet‐printed MSCs using other 2D nanomaterials. This work is an important step toward increasing the functional capacity of conductive inks and simplifying the fabrication of wearable textile‐based electronics.

Uzun, Simge↗

Structural dynamics of a thermally silent triiron( II ) spin crossover defect grid complex

The structural evolution of spin crossover (SCO) complexes during their spin transition at equilibrium and out-of-equilibrium conditions needs to be understood to enable their successful utilisation in displays, actuators and memory components. In this study, diffraction techniques were employed to study the structural changes accompanying the temperature increase and the light irradiation of a defect [2 × 2] triiron(II) metallogrid of the form [Fe II 3 L H 2 (HL H ) 2 ](BF 4 ) 4 ·4MeCN (FE3), L H = 3,5-bis{6-(2,2'-bipyridyl)}pyrazole. Although a multi-temperature crystallographic investigation on single crystals evidenced that the compound does not exhibit a thermal spin transition, the structural analysis of the defect grid suggests that the flexibility of the grid, provided by a metal-devoid vertex, leads to interesting characteristics that can be used for intermolecular cooperativity in related thermally responsive systems. Time-resolved photocrystallography results reveal that upon excitation with a ps laser pulse, the defect grid shows the first two steps of the out-of-equilibrium process, namely the photoinduced and elastic steps, occurring at the ps and ns time scales, respectively. Similar to a previously reported [2 × 2] tetrairon(II) metallogrid, FE3 exhibits a local distortion of the entire grid during the photoinduced step and a long-range distortion of the lattice during the elastic step. Although the lifetime of the pure photoinduced high spin (HS) state is longer in the tetranuclear grid than in the defect grid, suggesting that the global nuclearity plays a crucial role for the lifetime of the photoinduced species, the influence of the co-crystalising solvent on the lifetime of the photoinduced HS state remains unknown. This study sheds light on the out-of-equilibrium dynamics of a thermally silent defect triiron SCO metallogrid.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sensitivity analysis of thermal contact conductance modeling to inform MiniFuel irradiation capsule designs

The MiniFuel irradiation platform has been developed by Oak Ridge National Laboratory as a flexible, high-throughput separate effects testing capability within the High Flux Isotope Reactor (HFIR). Finite element thermal models are relied upon to design MiniFuel experiments to achieve a specific time-averaged irradiation temperature for experimental objectives. A previous study identified that uncertainty in the component heat generation rates and thermal contact conductance (TCC) model are the most significant contributors to predicted fuel temperature variance. To address both sources of uncertainty, this work performs sensitivity analysis on the TCC model to identify high-impact, high-uncertainty parameters that contribute to fuel temperature variance. The TCC model is analyzed in increasing detail, first using a standalone Python code, then again after coupling Python to the BISON fuel performance code. Furthermore, the parameters with the largest contributions to fuel temperature variance which can be reduced through design changes are identified as the initial subcapsule gas pressure, contact pressure between the fuel and dish, and the effective surface roughness of the interface. A set of design recommendations for future capsule designs has been established and applied to reduce the previously quantified average fuel temperature uncertainty ranges of ± 40 °C in the HFIR vertical experiment facilities (VXF) and ± 80 °C in the removable beryllium (RB) reflector to approximately ± 32 °C and ± 53 °C, respectively. This equates to a 21 % and 33 % reduction in the uncertainty range of the average fuel temperature for VXF and RB, respectively.

BISON↗

Commercial building HVAC demand flexibility with model predictive control: Field demonstration and literature insights

Model Predictive Control (MPC) for building Heating Ventilation and Air Conditioning (HVAC) systems is beginning to gain traction in the market, with a few controls companies incorporating it into their product offerings. However, it remains difficult to assess whether the energy cost savings are enough to justify the cost of MPC implementation for a particular building, given the limited number of reported demonstrations. For small commercial and residential buildings with relatively uniform systems, standardized approaches can help lower implementation costs. In contrast, for large buildings or district systems, the potential magnitude of cost savings could justify more customized solutions. Estimating the cost-effectiveness of MPC becomes more challenging for medium and large commercial buildings, where a one-size-fits-all solution may not be suitable, and the potential energy cost savings may be insufficient to justify a customized solution. To make MPC technology more appealing, incorporating additional value streams beyond energy efficiency alone can significantly increase its attractiveness. One such revenue stream is demand flexibility, in response to dynamic electricity prices, where MPC can leverage the thermal mass of the building to shift the load and support the grid. Building on an extensive literature review of MPC field studies focused on cost savings and demand flexibility, this paper presents the results of implementing MPC control in a large office building HVAC system in Berkeley, CA. Four different dynamic electricity price profiles were integrated into the MPC objective function to shift building demand while maintaining comfort, and field testing was performed with each price profile across four seasons. The results show potential for 40–65 % demand decrease percentage and up to 61 % annual cost savings compared to the existing rule-based control strategy, under the tested dynamic price scenarios. This paper also presents a sensitivity analysis on the cost savings with respect to the price profile variability, discusses the implementation effort for the price-responsive MPC, and compares the cost savings found in this study to those found in literature on the basis of dynamic price variability, or so-called Electricity Price Relative Standard Deviation.

Zanetti, Ettore↗

A hardware-in-the-loop approach for laboratory performance verification of flexible building equipment in a typical commercial building

The overall objective of the project is to develop datasets that measure the holistic load flexibility performance of a suite of commonly-used commercial building HVAC and thermal storage equipment using a hardware-in-the-loop test method. The development of the software side of the hardware-in-the-loop flexible load testbed is summarized in this paper.

Chen, Zhelun↗

Sustainable Energy Solutions for Thermal Load in Buildings—Role of Heat Pumps, Solar Thermal, and Hydrogen-Based Cogeneration Systems

Economic and population growth is leading to increased energy demand across all sectors—buildings, transportation, and industry. Adoption of new energy consumers such as electric vehicles could further increase this growth. Sensible utilization of clean renewable energy resources is necessary to sustain this growth. Thermal needs in a building pose a significant challenge to the energy infrastructure. Potential technological solutions to address growing energy demand while simultaneously lowering the carbon footprint and enhancing the grid flexibility are presented in this study. Performance assessment of heat pumps, solar thermal collectors, nonfossil fuel-based cogeneration systems, and their hybrid configurations is reported in this study. The impact of design configuration, coefficient of performance (COP), electric grid’s primary energy efficiency on the key attributes of total carbon footprint, life cycle costs, operational energy savings, and site-specific primary energy efficiency are analyzed and discussed in detail. In conclusion, heat pumps and hydrogen-fueled solid oxide fuel cells (SOFCs) are highly effective building energy resources compared to traditional approaches; however, the carbon intensity of electrical energy and hydrogen production are keys to the overall environmental benefit.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-Temperature Latent Heat Storage System using Transportable Heat Pipes for Versatile Integration with Emerging Microreactors

With the growing interest in the development of micro nuclear reactors and their application to microgrid, high-temperature thermal energy storage (TES) has also been receiving great attention as a technology to reinforce the energy utilization and profitability of this class of reactors. Given the importance and research needs of the TES technology, a research project is underway at Idaho National Laboratory (INL) to develop high-temperature TES that can be easily interfaced with emerging micro nuclear reactors. Currently under development is the Heat pipe-Integrated Thermal Battery (HITB), a novel latent heat storage design that enables flexible and robust integration with any design of currently considered micro nuclear reactors. The development of detailed design based on the proposed TES concept, HITB, requires not only development and validation of modeling and simulation capabilities, but also research that spans thermal performance analysis, component- and system-scale design optimization, and experimental demonstrations including high-temperature feasibility testing. The current research efforts (and plans) are divided into the following four areas: (i) Thermal and structural modeling and analysis at both system- and component-scales for evaluating performance and conducting design optimization, (ii) Small-scale experimental demonstrations for the key components of the proposed HITB design, (iii) Modelica-based dynamic model development for developing a control strategy under dynamic operation within integrated energy systems configuration, (iv) Integrated experimental testing and demonstration. This paper introduces the overall research efforts that have been and are being conducted to develop and demonstrate the novel design of the high-temperature latent heat storage device, HITB. The key design features, ongoing research efforts including the development of modeling and simulation capabilities, small-scale demonstrations of the HITB’s key functionalities prior to scaled-up experimental demonstration, are discussed. Then, this paper concludes with a remark on the future research plans for this project.

25 ENERGY STORAGE↗

Thermal coupling-decoupling mechanism of heat transfer across van der Waals interfaces in n-eicosane

Progress toward improving thermal transport properties of n-eicosane, a promising phase change material for thermal energy storage near human body temperature, is hindered by lack of a general theoretical framework to model thermal interfacial conductance (TIC) of the van der Waals (vdW) force bonded molecular interfaces, which have little compositional/structural mismatch. Combining molecular dynamics simulations at temperatures up to the melting point and a time-domain analysis of interfacial heat currents in individual molecules, we unveil that (1) the heat flux across a molecular vdW interface has an alternating coupling-decoupling pattern at the single molecule level due to thermal fluctuations, and (2) the net heat transfer during the thermally coupled periods is orders of magnitude larger than that during the thermally decoupled periods. Furthermore, we demonstrate that a vdW interface's TIC correlates almost linearly with two atomistic-scale coupling-decoupling parameters: αc and σc, that represent the duration and strength of the thermal coupling, respectively. This thermal coupling-decoupling mechanism proposes a new paradigm that explicitly accounts for the effects of structural flexibility and dynamical fluctuation on heat transfer across molecular interfaces, and will likely provide new insights into modeling thermal transport properties in a wide-ranging soft materials, including self-assembled monolayers, paraffins or lipids.

42 ENGINEERING↗

Photonic curing for innovative fabrication of flexible metal oxide optoelectronics

Abstract Flexible optoelectronics, based on non-planar substrates, hold promise for diverse applications such as wearables, health monitors, and displays due to their cost-effective manufacturing methods. Despite the superior properties of metal oxides, the challenge of processing them at high temperatures incompatible with plastic substrates necessitates innovative annealing approaches. Photonic curing, which delivers microsecond to millisecond broadband (200–1500 nm) light pulses on a sample, emerges as a viable solution. Depending on the optical properties, the targeted film absorbs the radiant energy resulting in rapid heating while the transparent substrate absorbs a minimal amount of light and remains at ambient temperature. The light intensity can be high, but since the light pulse is short, the total energy absorbed by the sample remains low and will not damage the plastic substrate. This perspective explores the innovative application of photonic curing to fabricate flexible metal oxide optoelectronics, including thin-film transistors, metal–insulator–metal devices, solar cells, transparent conductors, and Li batteries, emphasizing the conversion of sol–gel precursors to metal oxides. However, this technique was initially developed for sintering metal nanoparticles to conductive patterns and poses intriguing challenges in explaining its mechanism for metal oxide conversion, especially considering the limited absorption of visible light by most sol–gel precursors. The review delves into UV-induced photochemistry, common flexible metal-oxide optoelectronic components, and non-intuitive distinctions between photonic curing and thermal annealing. By elucidating the distinctive role of photonic curing in overcoming temperature-related challenges and advancing the fabrication of flexible metal oxide optoelectronics, this perspective offers valuable insights that could shape the future of flexible optoelectronics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Performance Investigation of High-temperature Latent Heat Storage for Integration with Advanced Nuclear Reactors

Integrating thermal energy storage (TES) with advanced nuclear reactors enhances the flexible use of nuclear energy, facilitating its expansion beyond conventional electricity generation. High-temperature TES, capable of storing heat above 400 degree C, emerges as a vital carbon-free energy solution for decarbonizing industrial sector, especially when combined with low-emission energy sources like advanced nuclear reactors. Idaho National Laboratory (INL) has recently developed a novel design for high-temperature latent heat storage system, called Heat pipe Integrated Thermal Battery (HITB), and efforts are underway to experimentally demonstrate the concept. HITB employs liquid-metal heat pipes to establish thermal linkage between TES and nuclear systems without direct fluid exchange, minimizing the potential risk of the integrated systems such as cross-contamination. HITB is designed to achieve high charging and discharging efficiency as well as high energy storage density by employing metal alloys as Phase Change Material (PCM). Initial proof-of-concept experiments are being undertaken using an aluminum alloy (Al59%-Mg35%-Zn6%). This paper discusses current progress of the HITB project at INL, seeking to develop high-temperature TES for versatile integration with advanced nuclear reactors, and shares insights from the performance evaluations via numerical modeling and analysis.

25 ENERGY STORAGE↗

Hierarchical Cellulose Superinsulation Membrane

The environment-friendly components coupled with the ability to mimic the simplicity and originality of nature necessitate advanced sustainable materials with structural capabilities for energy-efficient applications. The use of feedstock deriving from plant-based, renewable organic material to produce nanofibril that embodies enhanced insulating properties and high mechanical strength constitutes an efficient development strategy. In this work, a free-standing, hierarchical superinsulation membrane by leveraging the principle of the bottom-up method is reported. The electrospun cellulose nanofibrils/aerogel-based core layer provides exceptional thermal properties with its thermal conductivity of 10.2 mW m –1 K –1 . The lightweight, flexible, and durable paper-like membrane features a tensile strength of 11.3 MPa and a bending rigidity in the order of 4.6 cN mm –1 . The hydrophobic superinsulation membrane material also exhibits a ΔT of ≈25 °C under continuous sunlight illumination and allows thermal runaway mitigation of rechargeable lithium-ion batteries. All the aforementioned properties position this hybrid superinsulation membrane as a promising material for energy-saving thermal management applications.

36 MATERIALS SCIENCE↗

Research Highlight - Dispatch Optimization, System Design and Cost Benefit Analysis of a Nuclear Reactor with Molten Salt Thermal Storage

We highlight our work from our previous publication titled "Dispatch Optimization, System Design, and Cost Benefit Analysis of a Nuclear Reactor with Molten Salt Thermal Storage" published in MDPI Energies 2022 (doi.org/10.3390/en15103599). Variable renewable energy availability has increased the volatility in energy prices in most markets. Nuclear power plants, with a large ratio of capital to variable costs, have historically operated as base load energy suppliers but the need for more flexible operation is increasing. We simulate the techno-economic performance of a 950 MWt nuclear power plant, based on the Westinghouse lead-cooled fast reactor, coupled with molten salt thermal storage as a method for flexible energy dispatch. We use the System Advisor Model to model the nuclear reactor thermal power input and power cycle operating modes. We combine this robust engineering model with a mixed-integer linear program model for optimized dispatch scheduling. We then simulate the coupled nuclear and thermal storage system under different market scenarios with varying price volatility. We find that the coupled plant outperforms the base plant under markets where energy price peaks fluctuate by a factor of two or more about the mean price. We show that a calculated power purchase agreement price for the plant improves by up to 10% when operating under California energy market conditions. Sensitivity analysis on the thermal storage cost shows that the optimal design remains unchanged even when doubling costs.

97 MATHEMATICS AND COMPUTING↗

Dynamic Human-in-the-Loop Simulated Nuclear Power Plant Thermal Dispatch System Demonstration and Evaluation Study

An Idaho National Laboratory research team performed a human-in-the-loop study with two formerly licensed retired operators to evaluate thermal power dispatch operations supported by the modified GSE Systems GPWR plant simulator. Virtual representations of the analog control panels were presented on touch-screen bays configured to mimic the control room layout in the newly renovated Human Systems Simulation Laboratory. The operators performed 15 scenarios covering normal evolutions to transition the plant from full turbine operation to joint turbine and thermal power dispatch operations in addition to transient response scenarios induced with simulated faults to evaluate the impact of thermal power dispatch system on operator and plant responses. A prototype human-system interface (HSI) was developed and displayed in tandem with the virtual analog panels to support the operators executing the procedurally drive evolutions and transient responses. An interdisciplinary team of operations experts, nuclear engineers, and human factors experts observed the operators performing the scenarios to evaluate the operations. Only a preliminary analysis of the results has been performed. The full analysis will be shared in a milestone report scheduled for release at the end of September; however, some high-level conclusions were readily available. Two high level findings for the system design were captured in the study. The manual control supported by the HSI to transition from standard operations to thermal power dispatch operation imposed a considerable amount of workload on the operators due to tedious manual valve manipulations and system monitoring required to verify their intended effect. An additional operator would be required in the control room to support the daily evolution. Automatic control for the transition was deemed a requirement for plant adoption without imposing additional staffing costs. The second finding was the necessity for an automatic thermal power dispatch system trip isolation function linked to a turbine and reactor trip signal. The operators completed scenarios with automatic isolation functionality and manually required actuation of the thermal power dispatch system. The operator response was sufficiently slower in the manual trip condition, such that operators were unable to manually actuate key post trip safety functions an indicate a degraded control capability that should be avoided. With an automatic trip signal little to no impact of the thermal power dispatch system was identified on the primary plant response and therefore the system could be readily and safely adopted. Together these two findings represent the need to support the adoption of thermal power dispatch capability into existing operations by leveraging automation to augment any additional operator tasking required to control and monitor an additional system beyond existing operations.

99 GENERAL AND MISCELLANEOUS↗

Extraction of high-purity medium-chain-length polyhydroxyalkanoates via combined mechanical treatment and mild oxidation

Polyhydroxyalkanoates (PHAs) are a class of polyester polymers of microbial origin and considered biodegradable alternatives to conventional plastics. To make PHAs cost-competitive with synthetic plastics, their production cost, including extraction cost, should be significantly reduced. Herein, this study aimed to develop an effective extraction method based on combined mechanical disruption and chemical treatment for the recovery of high-purity medium-chain-length PHAs (mcl-PHAs) at a lower cost. mcl-PHAs-accumulating Pseudomonas strains were used for PHA extraction via high-pressure homogenization (HPH) coupled with surfactant treatment and mild alkaline hydrogen peroxide oxidation. The mechanical-chemical method was found to have strong synergy for PHA extraction while minimizing PHA depolymerization. The optimized condition resulted in nearly 90 % mcl-PHA recovery with high purity (>91 %). The extracted high-purity PHAs exhibited thermal and mechanical properties suitable for downstream applications entailing flexible and elastomeric materials.

42 ENGINEERING↗

Exploring diversion-pathway analysis of a generic molten-salt fast reactor using multiphysics informed signatures

Molten salt reactors are being explored by multiple commercial ventures due to their inherent safety features, flexibility in fuel sources, and high fuel utilization and thermal efficiency. The continual flow of fuel salt, large fissile quantities present, and ability to add or divert material due to the liquid nature introduces new challenges for international safeguards. To understand how international safeguards should be applied, it is important to capture the inherent multi-physics nature of a molten salt reactor. This work examines a generic molten salt fast reactor to understand how potential diversion scenarios would affect the concentration of radionuclides in the primary and auxiliary systems. Three types of diversion were examined: a slow drip of fuel salt, gaseous plutonium extraction, and uranium metal plating. The analysis determined that several key isotopes become statistically significant once diversion begins, indicating that detection of such diversion cases would be possible through measuring specific signatures such as gamma spectra.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Thermally unstable roosts influence winter torpor patterns in a threatened bat species

Abstract Many hibernating bats in thermally stable, subterranean roosts have experienced precipitous declines from white-nose syndrome (WNS). However, some WNS-affected species also use thermally unstable roosts during winter that may impact their torpor patterns and WNS susceptibility. From November to March 2017–19, we used temperature-sensitive transmitters to document winter torpor patterns of tricolored bats (Perimyotis subflavus) using thermally unstable roosts in the upper Coastal Plain of South Carolina. Daily mean roost temperature was 12.9 ± 4.9°C SD in bridges and 11.0 ± 4.6°C in accessible cavities with daily fluctuations of 4.8 ± 2°C in bridges and 4.0 ± 1.9°C in accessible cavities and maximum fluctuations of 13.8 and 10.5°C, respectively. Mean torpor bout duration was 2.7 ± 2.8 days and was negatively related to ambient temperature and positively related to precipitation. Bats maintained non-random arousal patterns focused near dusk and were active on 33.6% of tracked days. Fifty-one percent of arousals contained passive rewarming. Normothermic bout duration, general activity and activity away from the roost were positively related to ambient temperature, and activity away from the roost was negatively related to barometric pressure. Our results suggest ambient weather conditions influence winter torpor patterns of tricolored bats using thermally unstable roosts. Short torpor bout durations and potential nighttime foraging during winter by tricolored bats in thermally unstable roosts contrasts with behaviors of tricolored bats in thermally stable roosts. Therefore, tricolored bat using thermally unstable roosts may be less susceptible to WNS. More broadly, these results highlight the importance of understanding the effect of roost thermal stability on winter torpor patterns and the physiological flexibility of broadly distributed hibernating species.

Biodiversity & Conservation↗

Advanced Energy Approaches for Mixed-Use Developments in the Front Range Urban Corridor

The primary objective of the document is to present example technical approaches and strategies that planners and developers can reference for all-electric mixed-use developments in the Rocky Mountain Front Range urban corridor that are considering advanced energy performance goals such as high levels of energy efficiency and renewable integration. The strategies are tailored toward the vision for a zero energy, all-electric, district thermal system-connected starter district. In this example, on-site solar generation is emphasized as a strategy that can be combined with electrical and thermal energy storage for enhanced community resilience and demand flexibility. Opportunities for utilizing or adapting these strategies include: sharing with vertical developers for potential integration of strategies into vertical design guidelines; incorporation into Owner Project Requirements (OPRs); providing example strategies to design teams as a starting point for design; informing structure of agenda for a building design charrette; comparing building designs to example strategies at various points in the design process to evaluate design progression. While the technical strategies outlined in this document can help inform the development of guidelines for projects in the Front Range urban corridor, this document does not set requirements for any rating, certification, program, or policy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗