Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “systems testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Deploying Server-side File System Monitoring at NERSC

The Franklin Cray XT4 at the NERSC center was equipped with the server-side I/O monitoring infrastructure Cerebro/LMT, which is described here in detail. Insights gained from the data produced include a better understanding of instantaneous data rates during file system testing, file system behavior during regular production time, and long-term average behaviors. Information and insights gleaned from this monitoring support efforts to proactively manage the I/O infrastructure on Franklin. A simple model for I/O transactions is introduced and compared with the 250 million observations sent to the LMT database from August 2008 to February 2009.

97 MATHEMATICS AND COMPUTING↗

HTTR-GT/H2 test plant - system design - 18680

Pre-licensing basic design for a cogenerating HTGR test plant system is presented. The plant to be coupled to JAEA s existing 30 MWt 950 deg. C test reactor HTTR is intended as a system technology demonstrator for JAEA s commercial Gas turbine High Temperature Reactor Cogeneration (GTHTR300C) plant design. More specifically the test plant of HTTR-GT/H2 aims to 1) demonstrate the licensability of the GTHTR300C for electricity production by gas turbine and hydrogen cogeneration by thermochemical process and 2) confirm the operation control and safety of such cogeneration system. With construction and operation completion by 2025, the test plant is expected to be the first of a kind HTGR-powered cogeneration plant operating on the two advanced energy conversion systems of closed cycle helium gas turbine for power generation and thermochemical iodine-sulfur water-splitting process for hydrogen production. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Tests of a High Temperature Sample Conditioner for the Waste Treatment Plant LV-S2, LV S3, HV S3A and HV-S3B Exhaust Systems

Tests were performed to evaluate a sample conditioning unit for stack monitoring at Hanford Tank Waste Treatment and Immobilization Plant (WTP) exhaust stacks with elevated air temperatures. The LV-S2, LV-S3, HV-S3A and HV-S3B exhaust stacks are expected to have elevated air temperature and dew point. At these emission points, exhaust temperatures are too high to deliver the air sample directly to the required stack monitoring equipment. As a result, a sample conditioning system is considered to cool and dry the air prior to its delivery to the stack monitoring system. The method proposed for the sample conditioning is a dilution system that will introduce cooler, dry air to the air sample stream. This method of sample conditioning is meant to reduce the sample temperature while avoiding condensation of moisture in the sample stream. An additional constraint is that the ANSI/HPS N13.1-1999 standard states that at least 50% of the 10 µm aerodynamic diameter (AD) particles present in the stack free stream must be delivered to the sample collector. In other words, depositional loss of particles should be limited to 50% in the sampling, transport, and conditioning systems. Based on estimates of particle penetration through the LV-S3 sampling system, the diluter should perform with about 80% penetration or better to ensure that the total sampling system passes the 50% or greater penetration criterion.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tests of a High Temperature Sample Conditioner for the Waste Treatment Plant LV-S2, LV-S3, HV-S3A and HV-S3B Exhaust Systems

Tests were performed to evaluate a sample conditioning unit for stack monitoring at Hanford Tank Waste Treatment and Immobilization Plant (WTP) exhaust stacks with elevated air temperatures. The LV-S2, LV-S3, HV-S3A and HV-S3B exhaust stacks are expected to have elevated air temperature and dew point. At these emission points, exhaust temperatures are too high to deliver the air sample directly to the required stack monitoring equipment. As a result, a sample conditioning system is considered to cool and dry the air prior to its delivery to the stack monitoring system. The method proposed for the sample conditioning is a dilution system that will introduce cooler, dry air to the air sample stream. This method of sample conditioning is meant to reduce the sample temperature while avoiding condensation of moisture in the sample stream. An additional constraint is that the ANSI/HPS N13.1-1999 standard states that at least 50% of the 10 μm aerodynamic diameter (AD) particles present in the stack free stream must be delivered to the sample collector. In other words, depositional loss of particles should be limited to 50% in the sampling, transport, and conditioning systems. Based on estimates of particle penetration through the LV-S3 sampling system, the diluter should perform with about 80% penetration or better to ensure that the total sampling system passes the 50% or greater penetration criterion.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

ART CCIM PHASE II-A OFF-GAS SYSTEM EVALUATION TEST REPORT

AREVA Federal Services (AFS) is performing a multi-year, multi-phase Advanced Remediation Technologies (ART) project, sponsored by the U.S. Department of Energy (DOE), to evaluate the feasibility and benefits of replacing the existing joule-heated melter (JHM) used to treat high level waste (HLW) in the Defense Waste Processing Facility (DWPF) at the Savannah River Site with a cold crucible induction melter (CCIM). The AFS ART CCIM project includes several collaborators from AREVA subsidiaries, French companies, and DOE national laboratories. The Savannah River National Laboratory and the Commissariat a l’Energie Atomique (CEA) have performed laboratory-scale studies and testing to determine a suitable, high-waste-loading glass matrix. The Idaho National Laboratory (INL) and CEA are performing CCIM demonstrations at two different pilot scales to assess CCIM design and operation for treating SRS sludge wastes that are currently being treated in the DWPF. SGN is performing engineering studies to validate the feasibility of retrofitting CCIM technology into the DWPF Melter Cell. The long-term project plan includes more lab-testing, pilot- and large-scale demonstrations, and engineering activities to be performed during subsequent project phases. A simulant of the DWPF SB4 feed was successfully fed and melted in a small pilot-scale CCIM system during two test series. The OGSE tests provide initial results that (a) provide melter operating conditions while feeding a DWPF SB4 simulant feed, (b) determine the fate of feed organic and metal feed constituents and metals partitioning, and (c) characterize the melter off-gas source term to a downstream off-gas system. The INL CCIM test system was operated continuously for about 30 hours during the parametric test series, and for about 58 hours during the OGSE test. As the DWPF simulant feed was continuously fed to the melter, the glass level gradually increased until a portion of the molten glass was drained from the melter. The glass drain was operated periodically on-demand. A cold cap of unmelted feed was controlled by adjusting the feedrate and melter power levels to obtain the target molten glass temperatures with varying cold cap levels. Three test conditions were performed per the test plan, during which the melter was operated with a target melt temperature of either 1,250oC or 1,300oC, and with either a partial or complete cold cap of unmelted feed on top of the molten glass. Samples of all input and output streams including the starting glass, the simulant feed, the off-gas particulate matter, product glass, and deposits removed from the crucible and off-gas pipe after the test were collected for analysis.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Prototype Testing of Encapsulated Phase Change Material Thermal Energy Storage (EPCM-TES) for Concentrated Solar Power

In the present study, experimental investigations were conducted on encapsulated phase-change material (EPCM) capsules from Terrafore Technologies. Several aspects of the EPCM capsules were evaluated, including shell fracture stress under compression and melting/solidification performance. The stress testing was conducted with the Instron universal test system, and the melting/solidification testing was conducted in Argonne National Laboratory’s high-temperature thermal energy storage test system. Results on the EPCM fracture stress, the melting/solidification characteristics of the EPCM capsules, the temperature repeatability under similar test conditions, and the heat balance for melting/solidification processes are presented in this report.

14 SOLAR ENERGY↗

Optimal Power Dispatch of DGs in Radial and Mesh AC Grids: A Hybrid Solution Methodology between the Salps Swarm Algorithm and Successive Approximation Power Flow Method

In this paper, we address the problem of the optimal power dispatch of Distributed Generators (DGs) in Alternating Current (AC) networks, better known as the Optimal Power Flow (OPF) problem. We used, as the objective function, the minimization of power losses (P loss ) associated with energy transport, which are subject to the set of constraints that compose AC networks in an environment of distributed generation. To validate the effectiveness of the proposed methodology in solving the OPF problem in any network topology, we employed one 10-node mesh test system and three radial text systems: 10, 33, and 69 nodes. In each test system, DGs were allowed to inject 20%, 40%, and 60% of the power supplied by the slack generator in the base case. To solve the OPF problem, we used a master–slave methodology that integrates the optimization method Salps Swarm Algorithm (SSA) and the load flow technique based on the Successive Approximation (SA) method. Moreover, for comparison purposes, we employed some of the algorithms reported in the specialized literature to solve the OPF problem (the continuous genetic algorithm, the particle swarm optimization algorithm, the black hole algorithm, the antlion optimization algorithm, and the Multi-Verse Optimizer algorithm), which were selected because of their excellent results in solving such problems. The results obtained by the proposed solution methodology demonstrate its superiority and convergence capacity in terms of minimization of P loss in both radial and mesh systems. It provided the best reduction in minimum P loss in short processing times and showed excellent repeatability in each test system and scenario under analysis.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Tritium processing for the European test blanket systems: current status of the design and development strategy

Tritium processing technologies of the two European Test Blanket Systems (TBS), HCLL (Helium Cooled Lithium Lead) and HCPB (Helium Cooled Pebble Bed), play an essential role in meeting the main objectives of the TBS experimental campaign in ITER. The compliancy with the ITER interface requirements, in terms of space availability, service fluids, limits on tritium release, constraints on maintenance, is driving the design of the TBS tritium processing systems. Other requirements come from the characteristics of the relevant test blanket module and the scientific programme that has to be developed and implemented. This paper identifies the main requirements for the design of the TBS tritium systems and equipment and, at the same time, provides an updated overview on the current design status, mainly focusing onto the tritium extractor from Pb-16Li and TBS tritium accountancy. Considerations are also given on the possible extrapolation to DEMO breeding blanket. (authors)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Handbook for Performing Hydrocarbon Fuel Fires in XTF For Fast-Heat System Level Tests

This document serves to provide information on all aspects of a system level thermal qualification test including a description of the setup and conduct of a full system fuel fire test in the Thermal Test Complex (TTC) Crosswind Test Facility (XTF). This might be referred to as a “handbook” for future tests. This information is intended to assist technologists and test directors in performing these types of tests in the future.

42 ENGINEERING↗

NREL's Advanced Distribution Management System (ADMS) Test Bed

Transform utility electric distribution management systems to enable the integration and management of all assets and functions across the utility enterprise regardless of vendor or technology. Four program areas: Platform: Develop an open-source platform; evaluate advanced applications. Test bed: Build a vendor-neutral test bed to evaluate existing and future advanced distribution management system (ADMS) functionalities in a realistic setting. Applications: Develop an initial suite of ADMS applications. Advanced control: Develop new integrated optimization and control solutions.

ADMS test bed↗

Effects of Riser Diameter on Solids Holdup and Particle Velocity Profiles in Circulating Fluidized Bed Riser Systems

Tests were performed in a 0.1-m diameter small circulating fluidized bed (SCFB) and 0.3 m diameter cold flow circulating fluidized bed (CFCFB) riser systems located at the National Energy Technology Laboratory (NETL) to study the effects of riser diameter on the riser hydrodynamics. These tests were performed at solids circulation rates of G s = 20 and 75 kg/m 2 s and superficial gas velocities of U g = 5.8 and 6.5 m/s using high-density polyethylene (HDPE) pellets with a density of 0.863 g/cm 3 , particle size range of 600–1400 µm (with a Sauter mean diameter of 871 µm, placing them in the Geldart B classification). Comparisons of riser axial pressure and solids fraction profiles, radial particle velocity profiles, and radial profiles of higher statistical moments and select chaos analysis parameters were considered. The results showed that for a given U g and G s , the smaller diameter riser exhibited characteristics associated with more dilute solids flow than that observed in the larger diameter riser. Additionally, the larger diameter riser exhibited a downward flow of solids near the wall under all test conditions, whereas the smaller diameter riser data exhibited little or no indications of solids downflow near the wall. Overall, these findings suggest that, from an industrial standpoint, a direct scaleup of small-scale tests cannot readily be accomplished as the solids holdup and the solids velocity profiles in small units (those normally tested in the laboratory) are not similar to those of large units and the performance of large units can therefore not be predicted from small-scale tests.

42 ENGINEERING↗

Microfluidic-Based Robotic Sampling System for Radioactive Solutions

A novel microfluidic based robotic sampling system has been developed for sampling and analysis of liquid solutions in nuclear processes. This system couples the use of a microfluidic sample chip with a robotic system designed to allow remote, automated sampling of process solutions in-cell and facilitates direct coupling of the microfluidic sample chip with analytical instrumentation. This system provides the capability for near real time analysis, reduces analytical waste, and minimizes the potential for personnel exposure associated with traditional sampling methods. A prototype sampling system was designed, built and tested. System testing demonstrated operability of the microfluidic based sample system and identified system modifications to optimize performance.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermomechanical Characterization and Analysis of Insulation Materials for Nuclear-Based Space Power Systems

Testing was carried out to characterize and predict the long-term thermomechanical properties of various thermal insulation materials for use in nuclear-based space power systems. In particular, the high temperature compressive strength and stress relaxation behavior of these materials under vacuum or an inert atmosphere and up to 950 C were evaluated under either isothermal conditions or under various thermal gradients for test times of over two years. Several tests subjected to thermal gradient conditions were also evaluated for changes in strain due to cooling or heating events. Other testing of these materials included evaluation of their response to lateral (as opposed to axial) loads, their response to triaxial loading conditions, thermal shock behavior of these materials, and shrinkage effects in these materials due to elevated temperature exposure. Additionally, finite element and mathematical models were formulated to predict the mechanical behavior exhibited by these materials out to 35,000 hours (4 years) based on this testing. This paper will summarize the design and construction of unique test equipment to carry out this testing, along with the results of the testing and the subsequent modeling.

NESDPS Office of Nuclear Energy Space and Defense ↗

Pavilion 2 Feature Additions [Slides]

Pavilion 2 is a critical component of system testing for LANL HPC systems. Pavilion 2 is system independent, which allows for the creation of a large suite of generalized tests than can be applied to multiple systems. These additions to Pavilion 2 improve our ability to test systems and diagnose issues. With such a large suite, running the proper tests when diagnosing and fixing a system can be difficult, as well as locating old tests for reference. Test configurations may contain several permutations of a test, not all of which may apply to a given system. The ability to run sets of test permutations lets the tester focus on specific parts of the test without having to edit the test configurations or run extraneous tests. The addition of the filter argument improves the ability to find test results based on test attributes, including past tests. Pavilion 2's system independence is largely based on various layers of configuration files. Configuration files for the host, test, and modes exist to allow generalized testing. The operating system configuration layer can provide helpful OS defaults to a test. Survey, a collection and reporting tool, can help us gauge the performance of a system as well as diagnose issues. The addition of a Survey mode in Pavilion 2 makes running tests with Survey very straightforward. The Survey results are combined with Pavilion 2's test results to make it easy to access.

97 MATHEMATICS AND COMPUTING↗

Pavilion 2 Feature Additions [Slides]

Pavilion 2 is a critical component of system testing for LANL HPC systems. Pavilion 2 is system independent, which allows for the creation of a large suite of generalized tests than can be applied to multiple systems. These additions to Pavilion 2 improve our ability to test systems and diagnose issues. With such a large suite, running the proper tests when diagnosing and fixing a system can be difficult, as well as locating old tests for reference. Test configurations may contain several permutations of a test, not all of which may apply to a given system. The ability to run sets of test permutations lets the tester focus on specific parts of the test without having to edit the test configurations or run extraneous tests. The addition of the filter argument improves the ability to find test results based on test attributes, including past tests. Pavilion 2's system independence is largely based on various layers of configuration files. Configuration files for the host, test, and modes exist to allow generalized testing. The operating system configuration layer can provide helpful OS defaults to a test. Survey, a collection and reporting tool, can help us gauge the performance of a system as well as diagnose issues. The addition of a Survey mode in Pavilion 2 makes running tests with Survey very straightforward. The Survey results are combined with Pavilion 2's test results to make it easy to access.

97 MATHEMATICS AND COMPUTING↗

Production and testing of the powerboard for ATLAS ITk Strip barrel modules

The upgrade of the ATLAS ITk strips detector for HL-LHC will employ a custom PCB (powerboard) for on-module DC-DC conversion, HV switching, and monitoring. Production of about 14100 of such PCBs with high reliability is a big challenge. In this paper we will present the production procedure and quality control (QC) testing system for the powerboards to be installed on ITk Strip barrel modules. During production, about 150 powerboards will be produced every week. Each powerboard will need to pass QC tests before they are assembled to module. The QC tests include thermal cycling between -35 °C and 40 °C, soak test (continuous running of DC-DC converter at high load at 20 °C), and basic functionality and characterization electrical tests of the low voltage (LV), high voltage (HV), and monitoring functions of the powerboard. A custom QC test system is described, which is based on a reusable PCB (active board) with all testing circuits, a one-time powerboard carrier card, and a Z-turn SoC board which hosts and runs the testing program. The production procedure and QC test system has been tested with 400 powerboards during pre-production, and the system has been proven ready for production with the desired testing program, speed, safety, and cost. Performance and typical failures of powerboards observed during the QC test of pre-production powerboards is also presented.

47 OTHER INSTRUMENTATION↗