Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “systematic errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Sidelobe modeling and mitigation for a three mirror anastigmat cosmic microwave background telescope

Telescopes measuring cosmic microwave background (CMB) polarization on large angular scales require exquisite control of systematic errors to ensure the fidelity of the cosmological results. In particular, far-sidelobe contamination from wide angle scattering is a potentially prominent source of systematic error for large aperture microwave telescopes. Here we describe and demonstrate a ray-tracing-based modeling technique to predict far sidelobes for a three mirror anastigmat telescope designed to observe the CMB from the South Pole. Those sidelobes are produced by light scattered in the receiver optics subsequently interacting with the walls of the surrounding telescope enclosure. After comparing simulated sidelobe maps and angular power spectra for different enclosure wall treatments, we propose a highly scattering surface that would provide more than an order of magnitude reduction in the degree-scale far-sidelobe contrast compared to a typical reflective surface. Finally, we conclude by discussing the fabrication of a prototype scattering wall panel and presenting measurements of its angular scattering profile.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MAGNIFICENT MAGNIFICATION: EXPLOITING THE OTHER HALF OF THE LENSING SIGNAL

We describe a new method for measuring galaxy magnification due to weak gravitational lensing. Our method makes use of a tight scaling relation between galaxy properties that are modified by gravitational lensing, such as apparent size, and other properties that are not, such as surface brightness. In particular, we use a version of the well-known fundamental plane relation for early-type galaxies. This modified ''photometric fundamental plane'' uses only photometric galaxy properties, eliminating the need for spectroscopic data. We present the first detection of magnification using this method by applying it to photometric catalogs from the Sloan Digital Sky Survey. This analysis shows that the derived magnification signal is within a factor of three of that available from conventional methods using gravitational shear. We suppress the dominant sources of systematic error and discuss modest improvements that may further enhance the lensing signal-to-noise available with this method. Moreover, some of the dominant sources of systematic error are substantially different from those of shear-based techniques. With this new technique, magnification becomes a useful measurement tool for the coming era of large ground-based surveys intending to measure gravitational lensing.

79 ASTRONOMY AND ASTROPHYSICS↗

Dark Energy Survey year 3 results: point spread function modelling

ABSTRACT We introduce a new software package for modelling the point spread function (PSF) of astronomical images, called piff (PSFs In the Full FOV), which we apply to the first three years (known as Y3) of the Dark Energy Survey (DES) data. We describe the relevant details about the algorithms used by piff to model the PSF, including how the PSF model varies across the field of view (FOV). Diagnostic results show that the systematic errors from the PSF modelling are very small over the range of scales that are important for the DES Y3 weak lensing analysis. In particular, the systematic errors from the PSF modelling are significantly smaller than the corresponding results from the DES year one (Y1) analysis. We also briefly describe some planned improvements to piff that we expect to further reduce the modelling errors in future analyses.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurement of the inclusive jet cross section in pp collisions at sqrt(s)=2.76 TeV and comparison to the inclusive jet cross section at sqrt(s)=7 TeV using the ATLAS detector

CERN-LHC. This paper reports the measurement of inclusive jet cross sections in proton-proton collisions at a centre-of-mass energy of 2.76 TeV using a data sample of integrated luminosity of 0.20 pb-1 collected in 2011. Jets are identified using the anti-kt algorithm with two radius parameters (0.4 and 0.6). The cross sections are presented as a function of the jet transverse momentum and rapidity covering jets from 20-430 GeV in transverse momentum and |rapidity| < 4.4. The data are also compared with previous ATLAS 7 TeV cross sections as functions of PT and XT. The main tables below show the results correlated and uncorrelated systematic errors individually combined, as presented in the plots in the paper. The first table below gives access to the complete tables with the various sources of systematic error individually presented. Correlations over the rapidity bins and to the 7 TeV data are shown in table 1 of the paper and repeated below.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Intra- and Interfractional Variations for Prone Breast Irradiation: An Indication for Image-Guided Radiotherapy

Purpose: Intra- and interfractional errors for breast cancer patients undergoing breast irradiation in the prone position were analyzed. Methods and Materials: To assess intrafractional error resulting from respiratory motion, four-dimensional computed tomography scans were acquired for 3 prone and 3 supine patients, and the respiratory motion was compared for the two positions. To assess the interfractional error caused by daily set-up variations, daily electronic portal images of one of the treatment beams were taken for 15 prone-positioned patients. Portal images were then overlaid with images from the planning system that included the breast contour and the isocenter, treatment beam portal, and isocenter. The shift between the planned and actual isocenter was recorded for each portal image, and descriptive statistics were collected for each patient. The margins were calculated using the 2{sigma}+0.7{sigma} recipe, as well as 95% confidence interval based on the pooled standard deviation of the datasets. Results: Respiratory motion of the chest wall is drastically reduced from 2.3 {+-} 0.9 mm in supine position to -0.1 {+-} 0.4 mm in prone position. The daily set-up errors vary in magnitude from 0.0 cm to 1.65 cm and are patient dependent. The margins were defined by considering only the standard deviation to be 1.1 cm, and 2.0 cm when the systematic errors were considered using the 2{sigma}+0.7{sigma} recipe. Conclusions: Prone positioning of patients for breast irradiation significantly reduces the uncertainty introduced by intrafractional respiratory motion. The presence of large systematic error in the interfractional variations necessitates a large clinical target volume-to-planning target volume margin and indicates the importance of image guidance for partial breast irradiation in the prone position, particularly using imaging modality capable of identifying the lumpectomy cavity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improved determination of the fusion barrier distribution

The usual formula employed to estimate the barrier distribution in fusion reactions contains a systematic error. The origin of this error is related to the numerical approximation of the second derivative appearing in the expression of the barrier distribution. We show how to approximately correct for this systematic error. Previous determinations of the uncertainties in the barrier distribution, that did not include this error, could be severely underestimated. Furthermore, we find that minimization of the total error leads to an optimal energy grid at which the fusion cross section data should be taken.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Future prospects for constraining nuclear matter parameters with gravitational waves

The gravitational wave emission from the merging binary neutron star system GW170817 arrived full of tidal information which can be used to probe the fundamental ultradense nuclear physics residing in these stars. In previous work, we used two-dimensional correlations between nuclear matter parameters and tidal deformabilities of neutron stars applying specifically to GW170817 to derive constraints on the former. Here, we extend this analysis by finding similar correlations for varying chirp masses, the dominant determining factor in the frequency evolution of the inspiral, such that one can apply the same method to future detections. We estimate how accurately one can measure nuclear parameters with future gravitational wave interferometers and show how such measurements can be improved by combining multiple events. We find that bounds on the nuclear parameters with future observations can improve from the current one with GW170817 only by ~30% due to the existence of systematic errors caused mainly by the remaining uncertainty in the equation of state near and just above the nuclear saturation density. As a result, we show that such systematic errors can be reduced by considering multidimensional correlations among nuclear parameters and tidal deformabilities with various neutron star masses.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-D-204-01: Dual-Energy Calibration for Breast Density Measurement Using Spectral Mammography

Purpose: To investigate the feasibility of minimizing the systematic errors in dual-energy breast density quantification induced by the use of tissue-equivalent plastic phantoms as the calibration basis materials. Methods: Dual-energy calibration using tissue-equivalent plastic phantoms was performed on a spectral mammography system based on scanning multi-slit Si strip photon-counting detectors. The plastic phantom calibration used plastic water and adipose-equivalent phantoms as the basis materials, which have different x-ray attenuation properties compared to water and lipid in actual breast tissue. Two methods were used to convert the dual-energy decomposition measurements in plastic phantom thicknesses into true water and lipid basis. The first method was based entirely on the theoretical x-ray attenuation coefficients of the investigated materials in the mammographic energy range. The conversion matrix was determined from least-squares fitting of the target material using the reported attenuation coefficients of water and lipid. The second method was developed based on experimental calibrations, which measured the low-and high-energy signals of pure water and lipid of known thicknesses. A non-linear rational function was used to correlate the decomposed thicknesses to the known values, so that the conversion coefficients can be determined. Both methods were validated using independent measurements of water and lipid mixture phantoms. The correlation of the dual-energy decomposition measurements and the known values were studied with linear regression analysis. Results: There was an excellent linear correlation between the converted water thicknesses and the known values. The slopes of the linear fits were determined to be 0.63 and 1.03 for the simulation and experimental results, respectively. The non-linear fitting in the experimental approach reduced the root-mean-square (RMS) errors from approximately 3.4 mm to 1.5 mm. Conclusion: The results suggested that conversion of the dual-energy measurements into water and lipid thicknesses minimized the systematic errors in tissue decomposition studies.

60 APPLIED LIFE SCIENCES↗

JWST Noise Floor. I. Random Error Sources in JWST NIRCam Time Series

James Webb Space Telescope (JWST) transmission and emission spectra will provide invaluable glimpses of transiting exoplanet atmospheres, including possible biosignatures. This promising science from JWST, however, will require exquisite precision and understanding of systematic errors that can impact the time series of planets crossing in front of and behind their host stars. Here, we provide estimates of the random noise sources affecting JWST Near-Infrared Camera (NIRCam) time-series data on the integration-to-integration level. We find that 1/f noise can limit the precision of grism time series for two groups (230–1000 ppm depending on the extraction method and extraction parameters), but will average down like the square root of N frames/reads. The current NIRCam grism time-series mode is especially affected by 1/f noise because its GRISMR dispersion direction is parallel to the detector fast-read direction, but could be alleviated in the GRISMC direction. Care should be taken to include as many frames as possible per visit to reduce this 1/f noise source: thus, we recommend the smallest detector subarray sizes one can tolerate, four output channels, and readout modes that minimize the number of skipped frames (RAPID or BRIGHT2). We also describe a covariance-weighting scheme that can significantly lower the contributions from 1/f noise as compared to sum extraction. We evaluate the noise introduced by pre-amplifier offsets, random telegraph noise, and high dark current resistor capacitor (RC) pixels and find that these are correctable below 10 ppm once background subtraction and pixel masking are performed. We explore systematic error sources in a companion paper.

79 ASTRONOMY AND ASTROPHYSICS↗

UCAC3: ASTROMETRIC REDUCTIONS

Presented here are the details of the astrometric reductions from the x, y data to mean right ascension (R.A.), declination (decl.) coordinates of the third U.S. Naval Observatory CCD Astrograph Catalog (UCAC3). For these new reductions we used over 216,000 CCD exposures. The Two-Micron All-Sky Survey (2MASS) data are used extensively to probe for coordinate and coma-like systematic errors in UCAC data mainly caused by the poor charge transfer efficiency of the 4K CCD. Errors up to about 200 mas have been corrected using complex look-up tables handling multiple dependences derived from the residuals. Similarly, field distortions and sub-pixel phase errors have also been evaluated using the residuals with respect to 2MASS. The overall magnitude equation is derived from UCAC calibration field observations alone, independent of external catalogs. Systematic errors of positions at the UCAC observing epoch as presented in UCAC3 are better corrected than in the previous catalogs for most stars. The Tycho-2 catalog is used to obtain final positions on the International Celestial Reference Frame. Residuals of the Tycho-2 reference stars show a small magnitude equation (depending on declination zone) that might be inherent in the Tycho-2 catalog.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Variational quantum simulation of the critical Ising model with symmetry averaging

Here we investigate the use of deep multiscale entanglement renormalization ansatz (DMERA) circuits as a variational ansatz. We use the exactly solvable one-dimensional critical transverse-field Ising model as a test bed. Numerically exact simulation of the quantum circuit ansatz can in this case be carried out to hundreds of qubits by exploiting efficient classical algorithms for simulating matchgate circuits. We find that, for this system, the DMERA strongly outperforms a standard quantum approximate optimization algorithm (QAOA)–style ansatz, and that a major source of systematic error in correlation functions approximated using the DMERA is the breaking of the translational and Kramers-Wannier symmetries of the transverse-field Ising model. We are able to reduce this error by up to four orders of magnitude by symmetry averaging, without incurring additional cost in qubits or circuit depth. Here, we propose that this technique for mitigating systematic error could be applied to noisy intermediate-scale quantum (NISQ) simulations of physical systems with other symmetries.

1-dimensional spin chains↗

On the accuracy of stratospheric aerosol extinction derived from in situ size distribution measurements and surface area density derived from remote SAGE II and HALOE extinction measurements

In situ stratospheric aerosol measurements, from University of Wyoming optical particle counters (OPCs), are compared with Stratospheric Aerosol Gas Experiment (SAGE) II (versions 6.2 and 7.0) and Halogen Occultation Experiment (HALOE) satellite measurements to investigate differences between SAGE II/HALOE-measured extinction and derived surface area and OPC-derived extinction and surface area. Coincident OPC and SAGE II measurements are compared for a volcanic (1991-1996) and nonvolcanic (1997 2005) period. OPC calculated extinctions agree with SAGE II measurements, within instrumental uncertainty, during the volcanic period, but have been a factor of 2 low during the nonvolcanic period. Three systematic errors associated with the OPC measurements, anisokineticity, inlet particle evaporation, and counting efficiency, were investigated. An overestimation of the OPC counting efficiency is found to be the major source of systematic error. With this correction OPC calculated extinction increases by 15 30% (30 50%) for the volcanic (nonvolcanic) measurements. These changes significantly improve the comparison with SAGE II and HALOE extinctions in the nonvolcanic cases but slightly degrade the agreement in the volcanic period. These corrections have impacts on OPC-derived surface area density, exacerbating the poor agreement between OPC and SAGE II (version 6.2) surface areas. This disparity is reconciled with SAGE II version 7.0 surface areas. For both the volcanic and nonvolcanic cases these changes in OPC counting efficiency and in the operational SAGE II surface area algorithm leave the derived surface areas from both platforms in significantly better agreement and within the 40% precision of the OPC moment calculations.

54 ENVIRONMENTAL SCIENCES↗

Individual pore and interconnection size analysis of macroporous ceramic scaffolds using high-resolution X-ray tomography

The pore interconnection size of β-tricalcium phosphate scaffolds plays an essential role in the bone repair process. Although, the μCT technique is widely used in the biomaterial community, it is rarely used to measure the interconnection size because of the lack of algorithms. In addition, discrete nature of the μCT introduces large systematic errors due to the convex geometry of interconnections. We proposed, verified and validated a novel pore-level algorithm to accurately characterize the individual pores and interconnections. Specifically, pores and interconnections were isolated, labeled, and individually analyzed with high accuracy. The technique was verified thoroughly by visually inspecting and verifying over 3474 properties of randomly selected pores. This extensive verification process has passed a one-percent accuracy criterion. Scanning errors inherent in the discretization, which lead to both dummy and significantly overestimated interconnections, have been examined using computer-based simulations and additional high-resolution scanning. Then accurate correction charts were developed and used to reduce the scanning errors. Only after the corrections, both the μCT and SEM-based results converged, and the novel algorithm was validated. Material scientists with access to all geometrical properties of individual pores and interconnections, using the novel algorithm, will have a more-detailed and accurate description of the substitute architecture and a potentially deeper understanding of the link between the geometric and biological interaction. - Highlights: •An algorithm is developed to analyze individually all pores and interconnections. •After pore isolating, the discretization errors in interconnections were corrected. •Dummy interconnections and overestimated sizes were due to thin material walls. •The isolating algorithm was verified through visual inspection (99% accurate). •After correcting for the systematic errors, algorithm was validated successfully.

36 MATERIALS SCIENCE↗

THE DISKMASS SURVEY. II. ERROR BUDGET

We present a performance analysis of the DiskMass Survey. The survey uses collisionless tracers in the form of disk stars to measure the surface density of spiral disks, to provide an absolute calibration of the stellar mass-to-light ratio ({Upsilon}{sub *}), and to yield robust estimates of the dark-matter halo density profile in the inner regions of galaxies. We find that a disk inclination range of 25{sup 0}-35{sup 0} is optimal for our measurements, consistent with our survey design to select nearly face-on galaxies. Uncertainties in disk scale heights are significant, but can be estimated from radial scale lengths to 25% now, and more precisely in the future. We detail the spectroscopic analysis used to derive line-of-sight velocity dispersions, precise at low surface-brightness, and accurate in the presence of composite stellar populations. Our methods take full advantage of large-grasp integral-field spectroscopy and an extensive library of observed stars. We show that the baryon-to-total mass fraction (F{sub bar}) is not a well-defined observational quantity because it is coupled to the halo mass model. This remains true even when the disk mass is known and spatially extended rotation curves are available. In contrast, the fraction of the rotation speed supplied by the disk at 2.2 scale lengths (disk maximality) is a robust observational indicator of the baryonic disk contribution to the potential. We construct the error budget for the key quantities: dynamical disk mass surface density ({Sigma}{sub dyn}), disk stellar mass-to-light ratio ({Upsilon}{sub *}{sup disk}), and disk maximality (F{sub *,max}{sup disk} {identical_to} V{sub *,max}{sup disk}/ V{sub c}). Random and systematic errors in these quantities for individual galaxies will be {approx}25%, while survey precision for sample quartiles are reduced to 10%, largely devoid of systematic errors outside of distance uncertainties.

79 ASTRONOMY AND ASTROPHYSICS↗

ON THE ESTIMATION OF SYSTEMATIC UNCERTAINTIES OF STAR FORMATION HISTORIES

In most star formation history (SFH) measurements, the reported uncertainties are those due to effects whose sizes can be readily measured: Poisson noise, adopted distance and extinction, and binning choices in the solution itself. However, the largest source of error, systematics in the adopted isochrones, is usually ignored and very rarely explicitly incorporated into the uncertainties. I propose a process by which estimates of the uncertainties due to evolutionary models can be incorporated into the SFH uncertainties. This process relies on application of shifts in temperature and luminosity, the sizes of which must be calibrated for the data being analyzed. While there are inherent limitations, the ability to estimate the effect of systematic errors and include them in the overall uncertainty is significant. The effects of this are most notable in the case of shallow photometry, with which SFH measurements rely on evolved stars.

79 ASTRONOMY AND ASTROPHYSICS↗

A Comparison of the Use of Bony Anatomy and Internal Markers for Offline Verification and an Evaluation of the Potential Benefit of Online and Offline Verification Protocols for Prostate Radiotherapy

Purpose: To evaluate the utility of intraprostatic markers in the treatment verification of prostate cancer radiotherapy. Specific aims were: to compare the effectiveness of offline correction protocols, either using gold markers or bony anatomy; to estimate the potential benefit of online correction protocol's using gold markers; to determine the presence and effect of intrafraction motion. Methods and Materials: Thirty patients with three gold markers inserted had pretreatment and posttreatment images acquired and were treated using an offline correction protocol and gold markers. Retrospectively, an offline protocol was applied using bony anatomy and an online protocol using gold markers. Results: The systematic errors were reduced from 1.3, 1.9, and 2.5 mm to 1.1, 1.1, and 1.5 mm in the right-left (RL), superoinferior (SI), and anteroposterior (AP) directions, respectively, using the offline correction protocol and gold markers instead of bony anatomy. The subsequent decrease in margins was 1.7, 3.3, and 4 mm in the RL, SI, and AP directions, respectively. An offline correction protocol combined with an online correction protocol in the first four fractions reduced random errors further to 0.9, 1.1, and 1.0 mm in the RL, SI, and AP directions, respectively. A daily online protocol reduced all errors to <1 mm. Intrafraction motion had greater impact on the effectiveness of the online protocol than the offline protocols. Conclusions: An offline protocol using gold markers is effective in reducing the systematic error. The value of online protocols is reduced by intrafraction motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Calibration of time-of-flight cameras for accurate intraoperative surface reconstruction

Purpose: In image-guided surgery (IGS) intraoperative image acquisition of tissue shape, motion, and morphology is one of the main challenges. Recently, time-of-flight (ToF) cameras have emerged as a new means for fast range image acquisition that can be used for multimodal registration of the patient anatomy during surgery. The major drawbacks of ToF cameras are systematic errors in the image acquisition technique that compromise the quality of the measured range images. In this paper, we propose a calibration concept that, for the first time, accounts for all known systematic errors affecting the quality of ToF range images. Laboratory and in vitro experiments assess its performance in the context of IGS.Methods: For calibration the camera-related error sources depending on the sensor, the sensor temperature and the set integration time are corrected first, followed by the scene-specific errors, which are modeled as function of the measured distance, the amplitude and the radial distance to the principal point of the camera. Accounting for the high accuracy demands in IGS, we use a custom-made calibration device to provide reference distance data, the cameras are calibrated too. To evaluate the mitigation of the error, the remaining residual error after ToF depth calibration was compared with that arising from using the manufacturer routines for several state-of-the-art ToF cameras. The accuracy of reconstructed ToF surfaces was investigated after multimodal registration with computed tomography (CT) data of liver models by assessment of the target registration error (TRE) of markers introduced in the livers.Results: For the inspected distance range of up to 2 m, our calibration approach yielded a mean residual error to reference data ranging from 1.5 ± 4.3 mm for the best camera to 7.2 ± 11.0 mm. When compared to the data obtained from the manufacturer routines, the residual error was reduced by at least 78% from worst calibration result to most accurate manufacturer data. After registration of the CT data with the ToF data, the mean TRE ranged from 3.7 ± 2.1 mm for point-based and 5.7 ± 1.9 mm for surface-based registration for the best camera to 6.2 ± 3.4 and 11.1 ± 2.8 mm, respectively. Compared to data provided by the manufacturer, the mean TRE decreased by 8%–60% for point-based and by 18%–74% for surface-based registration.Conclusions: Using the proposed calibration approach improved the measurement accuracy of all investigated ToF cameras. Although evaluated in the context of intraoperative image acquisition, the proposed calibration procedure can easily be applied to other medical applications using ToF cameras, such as patient positioning or respiratory motion tracking in radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sources of error in detonation calorimeters and error analysis for neat 2,4,6-triamino-1,3,5- trinitrobenzene (TATB)

Here, a calorimeter for measuring heats of detonation at Lawrence Livermore National Laboratory is described. A calibration precision of 0.2 % at the 95 % confidence interval (CI) is reported. Sources of uncertainty are discussed, including nonequivalent sources, which are those arising from differences between calibration and experimental tests. The systematic error due to nonequivalent sources is bounded to 0.19–0.22 % of the measured heat for a standard detonation test where the confinement material is gold. The recommendation is to correct for the systematic error by adding 0.19 % to the reported value and adding 0.03 % to the uncertainty. It is demonstrated that the precision of a detonation test is variable with testing duration because a source of uncertainty resides in the thermodynamic correction factor k6, which accounts for the contribution to heat by stirring; the generated power is additive and therefore highly impacted by total test time. The relative proportion also varies with the magnitude of heat release and sample size, adding variance to the weight of the error arising from the correction factor. A full error analysis based on the described sources of uncertainty is developed. The methodology is applied to a test series on neat 2,4,6-triamino-1,3,5- trinitrobenzene (TATB), demonstrating an ultimate precision of 0.7 % (single test) for materials testing and a relative standard deviation of 1.8 %.

47 OTHER INSTRUMENTATION↗