Portable diagnostic package for Thomson scattering and optical emission spectroscopy on Princeton field-reversed configuration 2 (PFRC 2)

An Advanced Research Projects Agency-Energy funded diagnostic system has been deployed to the Princeton field-reversed configuration 2 (PFRC-2) device, located at Princeton Plasma Physics Laboratory. The Portable Diagnostic Package (PDP), designed at Oak Ridge National Laboratory, allows for the measurement of Thomson Scattering (TS) for electron density and temperature and Optical Emission Spectroscopy (OES) for ion temperature, impurity density, and ion velocity. A tunable spectrometer on the PDP with three gratings provides the flexibility to measure low (1 eV) and high (1000 eV) electron temperature ranges from TS. Additionally, using a second spectrometer, the OES diagnostic can survey light emission from various ion excitation levels for wide wavelength ranges. The electron density (<2 × 10 19 m –3 ) of plasmas generated in PFRC-2 has been below the PDP TS discrimination threshold, which has made TS signal detection challenging against a high-background of laser stray light. The laser stray light was iteratively reduced by making modifications to the entrance and exit geometry on PFRC-2. Rayleigh scattering experiments on PFRC have yielded the TS discrimination sensitivity to be >1 × 10 20 m –3 for the PDP. A recently implemented narrow-band notch spectral filter that masks the second harmonic 532 nm Nd:YAG laser wavelength has increased the system’s TS light discrimination sensitivity 65 times compared to the instance when the notch filter was not implemented. The hardware implementation including design changes to the flight tubes and Brewster windows will be discussed, along with results from Rayleigh and rotational Raman scattering sensitivity analyses, which were used to establish a quantitative figure of merit on the system performance. Further, the Raman scattering calibration with the notch filter has improved the PDP electron density threshold to 1 ± 0.5 × 10 18 m –3 .

47 OTHER INSTRUMENTATION↗

Corn stover harvest reduces soil CO 2 fluxes but increases overall C losses

Abstract Harvesting corn ( Zea mays L.) stover for use as bioenergy feedstock may provide short‐term economic benefits and perhaps improve grain yield in continuous corn systems, but excessive stover removal may lead to long‐term depletion of soil C stocks. To better quantify the impacts of stover harvest on the soil C balance, we investigated CO 2 fluxes under three harvest treatments (none, moderate, and high) in three continuous corn systems: (a) no tillage and no biochar applications, (b) chisel plowing with biochar amendments, and (c) chisel plowing without biochar amendments were quantified. We sampled static chambers 14, 13, and 15 times in 2010, 2011, and 2012, respectively, and the measurements were used to calibrate the Agricultural Production Systems sIMulator model. Although CO 2 ‐C emissions did not differ among the three systems, both moderate (approximately 30%) and high (approximately 60%) stover removal rates reduced simulated CO 2 ‐C emissions by nearly 10% and more than 22%, respectively. Despite these reductions in CO 2 flux, the sum of CO 2 ‐C and stover C exceeded CO 2 ‐C losses in those plots without stover removal. This finding suggested soil C depletion was occurring for the soil and crop management practices used, even though depletion was not evident after 3 years. Application of biochar increased soil C levels, suggesting it may be able to offset some C losses. We conclude that for sustainable, highly productive agroecosystems that include stover harvest, all agronomic practices must be optimized to minimize C losses and maintain soil quality.

54 ENVIRONMENTAL SCIENCES↗

A Radiation-Hard 8-Channel 15-Bit 40-MSPS ADC for the ATLAS Liquid Argon Calorimeter Readout

The custom design of a radiation-hardened, 8-channel, 40-MSPS, 15-bit resolution, 14.2-bit dynamic range, 11.4-ENOB ADC data acquisition ASIC fabricated in a commercial 65-nm triple-well CMOS technology is presented. The ADC is developed for and integrates seamlessly into the readout system for the ATLAS liquid argon (LAr) calorimeter in the high-luminosity large hadron collider (HLLHC) upgrade at CERN, which will require a total of 364 936 ADC channels. A three-stage MDAC+SAR pipelined ADC architecture was designed to meet the physics requirements and scientific goals of the ATLAS experiment. The ADC is a fully self-contained data acquisition system that includes foreground calibration, digital data processing, digital control, and supporting circuitry. The measured performance shows the ADC achieves a competitive dynamic range and SNDR, and it meets or exceeds the ATLAS analog requirements. Radiation tolerance and scalability design considerations were implemented at the device-, circuit-, and system-level. Radiation-hardening-by-design techniques used include redundancy for digital circuits, the use of MiM capacitors, and a hybrid RC-DAC for the ADC core. The ADC ASIC was demonstrated to be robust against the effects of the intense radiation expected in the HL-LHC experimental environment.

DAQ↗

Optode performance data associated with: Metabolic Multireactor: practical considerations for using simple oxygen sensing optodes for high-throughput batch reactor metabolism experiments

This data package is associated with the publication “Metabolic Multireactor: practical considerations for using simple oxygen sensing optodes for high-throughput batch reactor metabolism experiments”, submitted to PlosONE (Kaufman et al. 2023; 10.1101/2023.03.28.534656).We carried out many testing and calibration experiments on a system of small oxygen consumption batch reactors designed for use with water and sediment samples for environmental questions. The oxygen sensing system is based very directly on the work of Larsen, et al. [2011], and similar oxygen sensing technology is widely used in the literature. Our primary focus was on practical considerations, such as temperature effects, lighting angle effects, sterilization, and other similar situations that a user may find useful. Most of the tests required comparing “base” calibration curves to “treatment” calibration curves to determine the extent to which the treatment impacted the reported measurements. This data package contains the performance and calibration data collected for that purpose.This dataset is comprised of one data folder containing (1) file-level metadata; (2) data dictionary; (3) readme; (4) diffusion test result files; (5) limit of detection test result files; (6) temperature impact files; (7) a main data file that contains test results for all other tests; and (8) an R script that uses Kolmogorov-Smirnov tests to determine whether treatment calibrations are significantly different from their respective base calibrations. All files are .csv, .txt, .Rmd, or .pdf.

54 ENVIRONMENTAL SCIENCES↗

Uniform Recalibration of Common Spectrophotometry Standard Stars onto the CALSPEC System Using the SuperNova Integral Field Spectrograph

Abstract We calibrate spectrophotometric optical spectra of 32 stars commonly used as standard stars, referenced to 14 stars already on the Hubble Space Telescope–based CALSPEC flux system. Observations of CALSPEC and non-CALSPEC stars were obtained with the SuperNova Integral Field Spectrograph over the wavelength range 3300–9400 Å as calibration for the Nearby Supernova Factory cosmology experiment. In total, this analysis used 4289 standard-star spectra taken on photometric nights. As a modern cosmology analysis, all presubmission methodological decisions were made with the flux scale and external comparison results blinded. The large number of spectra per star allows us to treat the wavelength-by-wavelength calibration for all nights simultaneously with a Bayesian hierarchical model, thereby enabling a consistent treatment of the Type Ia supernova cosmology analysis and the calibration on which it critically relies. We determine the typical per-observation repeatability (median 14 mmag for exposures ≳5 s), the Maunakea atmospheric transmission distribution (median dispersion of 7 mmag with uncertainty 1 mmag), and the scatter internal to our CALSPEC reference stars (median of 8 mmag). We also check our standards against literature filter photometry, finding generally good agreement over the full 12 mag range. Overall, the mean of our system is calibrated to the mean of CALSPEC at the level of ∼3 mmag. With our large number of observations, careful cross-checks, and 14 reference stars, our results are the best calibration yet achieved with an integral-field spectrograph, and among the best calibrated surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Dwarf galaxy halo masses from spectroscopic and photometric lensing in DESI and DES

We present the most precise and lowest-mass weak lensing measurements of dwarf galaxies to date, enabled by spectroscopic lenses from the Dark Energy Spectroscopic Instrument (DESI) and photometric lenses from the Dark Energy Survey (DES) calibrated with DESI redshifts. Using DESI spectroscopy from the first data release, we construct clean samples of galaxies with median stellar masses $\log_{10}(M_*/M_{\odot})=8.3-10.1$ and measure their weak lensing signals with sources from DES, KiDS, and SDSS, achieving detections with $S/N$ up to 14 for dwarf galaxies ($\log_{10}(M_*/M_{\odot})<$9.25) -- opening up a new regime for lensing measurements of low-mass systems. Leveraging DES photometry calibrated with DESI, we extend to a photometric dwarf sample of over 700,000 galaxies, enabling robust lensing detections of dwarf galaxies with combined $S/N=38$ and a significant measurement down to $\log_{10}(M_*/M_{\odot})=8.0$. We show that the one-halo regime (scales $\lesssim 0.15h^{-1}\rm Mpc$) is insensitive to various systematic and sample selection effects, providing robust halo mass estimates, while the signal in the two-halo regime depends on galaxy color and environment. These results demonstrate that DESI already enables precise dwarf lensing measurements, and that calibrated photometric samples extend this capability. Together, they pave the way for novel constraints on dwarf galaxy formation and dark matter physics with upcoming surveys like the Vera C. Rubin Observatory's LSST.

Treiber, Helena [Princeton U., Astrophys. Sci. Dep↗

Calibration of the CMS hadron calorimeters using proton-proton collision data at √ s = 13 TeV

Methods are presented for calibrating the hadron calorimeter system of the CMS detector at the LHC. The hadron calorimeters of the CMS experiment are sampling calorimeters of brass and scintillator, and are in the form of one central detector and two endcaps. These calorimeters cover pseudorapidities |η| < 3 and are positioned inside the solenoidal magnet. An outer calorimeter, outside the magnet coil, covers |η| < 1.26, and a steel and quartz-fiber Cherenkov forward calorimeter extends the coverage to |η| < 5.19. The initial calibration of the calorimeters was based on results from test beams, augmented with the use of radioactive sources and lasers. The calibration was improved substantially using proton-proton collision data collected at √ s = 7 , 8, and 13 TeV, as well as cosmic ray muon data collected during the periods when the LHC beams were not present. The present calibration is performed using the 13 TeV data collected during 2016 corresponding to an integrated luminosity of 35.9 fb -1 . The intercalibration of channels exploits the approximate uniformity of energy collection over the azimuthal angle. The absolute energy scale of the central and endcap calorimeters is set using isolated charged hadrons. The energy scale for the electromagnetic portion of the forward calorimeters is set using Z→ ee data. The energy scale of the outer calorimeters has been determined with test beam data and is confirmed through data with high transverse momentum jets. In this paper, we present the details of the calibration methods and accuracy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

RTN-099: Photometric Transformation Relations for the LSST Data Preview 1

This technical note provides photometric transformation relations between the Vera C. Rubin Observatory's LSSTCam and LSSTComCam systems and other photometric systems. These transformations are derived using both synthetic and empirical data and are intended to support calibration and comparison across survey systems. We present both polynomial equations and lookup-table-based methods, depending on the available data and desired accuracy. The transformations are generally valid for stars with typical spectral energy distributions (SEDs), and caution should be used when applying them to objects with strong emission lines or atypical colors.

79 ASTRONOMY AND ASTROPHYSICS↗

RTN-125: Photometric Transformation Relations for the LSST Data Preview 2

This technical note provides photometric transformation relations between the NSF-DOE Vera C. Rubin Observatory's Data Preview 2 (DP2) and other photometric systems. These transformations are derived using both synthetic and empirical data and are intended to support calibration and comparison across survey systems. We present both polynomial equations and lookup-table-based methods, depending on the available data and desired accuracy. The transformations are generally valid for stars with typical spectral energy distributions (SEDs), and caution should be used when applying them to objects with strong emission lines or atypical colors.

79 ASTRONOMY AND ASTROPHYSICS↗

Markov Process to Evaluate the Value Proposition of a Risk-Informed Predictive Maintenance Strategy

To achieve high-capacity factors, the nuclear fleet has relied on labor-intensive and time-consuming operation and preventive maintenance programs for plant systems. Manually performed inspection, calibration, testing, and maintenance of plant assets at periodic frequencies, along with time-based replacement of assets irrespective of condition, have resulted in a costly, labor-centric business model. Fortunately, there are technologies that can eliminate unnecessary preventive maintenance activities by deploying risk-informed predictive maintenance, enabling the transition to a technology-centric business model. The technology-centric business model will enable plants to optimize and automate maintenance activities, leading to cost reductions since labor is a rising cost and technology is a declining cost. The implementation of scalable technologies and methodologies across plant systems and across the nuclear fleet is critical for successful deployment of a risk-informed predictive maintenance strategy at commercial nuclear power plants. The work presented in the report is being developed as part of a collaborative research effort between Idaho National Laboratory and Public Service Enterprise Group Nuclear, LLC. This report describes the technical basis using the Markov Process to evaluate the value proposition for the risk-informed predictive maintenance strategy for the circulating water system. The plant process data from the Salem nuclear plant’s circulating water system is utilized to develop a Markov chain risk models and formulation to estimate the loss and gain in revenue based on plant availability. The outcomes presented in this report provides the technical basis for extensive quantitative evaluation of a scalable risk-informed predictive maintenance strategy as part of future research.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatially calibrating polycyclic aromatic hydrocarbons (PAHs) as proxies of area burned by vegetation fires: Insights from comparisons of historical data and sedimentary PAH fluxes

Many regions worldwide have experienced increasing wildfire activity in recent years and climate changes are predicted to result in more frequent and severe fires. Reconstruction of past fire activity offers paleoenvironmental context for modern and future burning. Pyrogenic polycyclic aromatic hydrocarbons (PAHs) have been increasingly used as a molecular biomarker for fire occurrence in the paleorecord and offer opportunity for nuanced reconstructions of fire characteristics. A suite of PAHs are produced during combustion, and the emission amount and assemblage is influenced by many variables including fuel type, fire temperature, and oxygen availability. Despite recent advances in understanding the controls and taphonomy of these biomass burning markers, the spatial scale of this proxy is unknown. In this paper, measurements of PAH fluxes preserved in a lake sediment archive from the Sierra Nevada, California were compared with a historical geographic information system dataset of area burned up to 150 km distance from the lake to determine the spatial scales for which these biomarkers are reliable proxies of burning. Comparisons of PAH fluxes with charcoal accumulation rates in the same sediments suggest that pyrogenic particulate transport modulates low to mid-molecular weight PAHs via adsorption. Overall, the results indicate that PAH records integrate a combination of spatial signals of area burned and measurement of individual PAHs may enable cross-scale paleofire reconstructions.

54 ENVIRONMENTAL SCIENCES↗

A Diffusion‐Based Uncertainty Quantification Method to Advance E3SM Land Model Calibration

Abstract Calibrating land surface models and accurately quantifying their uncertainty are crucial for improving the reliability of simulations of complex environmental processes. This, in turn, advances our predictive understanding of ecosystems and supports climate‐resilient decision‐making. Traditional calibration methods, however, face challenges of high computational costs and difficulties in accurately quantifying parameter uncertainties. To address these issues, we develop a diffusion‐based uncertainty quantification (DBUQ) method. Unlike conventional generative diffusion methods, which are computationally expensive and memory‐intensive, DBUQ innovates by formulating a parameterized generative model and approximates this model through supervised learning, which enables quick generation of parameter posterior samples to quantify its uncertainty. DBUQ is effective, efficient, and general‐purpose, making it suitable for site‐specific ecosystem model calibration and broadly applicable for parameter uncertainty quantification across various earth system models. In this study, we applied DBUQ to calibrate the Energy Exascale Earth System Model land model at the Missouri Ozark AmeriFlux forest site. Results indicated that DBUQ produced accurate parameter posterior distributions similar to those from Markov Chain Monte Carlo sampling but with 30 times less computing time. This significant improvement in efficiency suggests that DBUQ can enable rapid, site‐level model calibration at a global scale, enhancing our predictive understanding of climate impacts on terrestrial ecosystems.

54 ENVIRONMENTAL SCIENCES↗

A Model Calibration Method for Grid-Forming Inverters Using Iterative Bayesian Optimization

As inverter-based resources (IBRs) are rapidly deployed, especially at the distribution and microgrid levels, the need to include their accurate representations in power systems models increases. With well-calibrated models, IBR-interactions can be examined, preventing any stability and operational issues, especially in islanded systems. This paper proposes a method to calibrate generic inverter models using Bayesian optimization, but with a parameter-grouping approach to improve speed and accuracy. This approach is illustrated for a grid-forming inverter using synthetic data and field measurements from a simple IBRbased microgrid. Tests show that the calibration algorithm has modest computation cost and is robust to noisy measurements..

Biswas, Shuchismita↗

An open-source data storage and visualization platform for collaborative qubit control

Developing collaborative research platforms for quantum bit control is crucial for driving innovation in the field, as they enable the exchange of ideas, data, and implementation to achieve more impactful outcomes. Furthermore, considering the high costs associated with quantum experimental setups, collaborative environments are vital for maximizing resource utilization efficiently. However, the lack of dedicated data management platforms presents a significant obstacle to progress, highlighting the necessity for essential assistive tools tailored for this purpose. Current qubit control systems are unable to handle complicated management of extensive calibration data and do not support effectively visualizing intricate quantum experiment outcomes. In this paper, we introduce Qubit Control Storage and Visualization ( QubiCSV ), a platform specifically designed to meet the demands of quantum computing research, focusing on the storage and analysis of calibration and characterization data in qubit control systems. As an open-source tool, QubiCSV facilitates efficient data management of quantum computing, providing data versioning capabilities for data storage and allowing researchers and programmers to interact with qubits in real time. The insightful visualization are developed to interpret complex quantum experiments and optimize qubit performance. QubiCSV not only streamlines the handling of qubit control system data but also improves the user experience with intuitive visualization features, making it a valuable asset for researchers in the quantum computing domain.

97 MATHEMATICS AND COMPUTING↗

An improved Method for Determining Transient Fuel Dilution of Oil in an Internal-Combustion Engine Using Laser-Induced Florescence and Multivariate Least Square Calibration

An optical diagnostic, based on laser-induced fluorescence (LIF), has been developed for on-engine measurements of real-time fuel dilution of engine oil or fuel in oil (FIO). Fuel dilution of oil is broadly relevant to advancing engine technology including durability, calibration, and catalyst-system management, and believed to promote destructive stochastic pre-ignition (SPI) during high-load engine operations. While standard (e.g., ASTM D3524-90) methods are not capable of real-time transient measurements, the LIF technique resolves transient dilution on the minutes time scale. We have expanded on our original FIO instrument development by introducing an improved analysis based on multivariate least square chemometrics analysis. The measurement uses a fuel dye (180–1300 parts per million, by mass) and monitors for its presence in the oil using 532 nm excitation and LIF. While the original FIO instrument utilized a two-color ratio method for analysis, the improved chemometric analysis uses the fully resolved LIF dye spectra to provide better predictive FIO accuracy (>92%) over a wide FIO range (1.5–14%) typical of engine application. We also investigate the effect of oil temperature on the LIF signal. Limited engine applications for demonstrating and validating the improved FIO instrument are shown, and the related data used to quantify practical detection limit and sensitivity. The improved analysis is insensitive to laser power fluctuation and change in detector integration time, providing an excellent FIO sensitivity (1–2%) and detection limit (0.01 %FIO) over a wide range of loads and injection timings, illustrating this updated approach to be a promising tool for advancing engine technology.

42 ENGINEERING↗

New Absolute Cavity Pyrgeometer equation by application of Kirchhoff's law and adding a convection term

An equation for the Absolute Cavity Pyrgeometer (ACP) is derived from application of Kirchhoff's law and the addition of a convection term to account for the thermopile being open to the environment, unlike a domed radiometer. The equation is then used to investigate four methods to characterise key instrumental parameters using laboratory and field measurements. The first uses solar irradiance to estimate the thermopile responsivity, the second uses a minimisation method that solves for the thermopile responsivity and transmission of the cavity, and the third and fourth revisit the Reda et al. (2012) linear least squares calibration technique. Data were collected between January and November 2020, when the ACP96 and two IRIS radiometers monitoring terrestrial irradiances were available. The results indicate good agreement with IRIS irradiances using the new equation. The analysis also indicates that while the thermopile responsivity, concentrator transmission and emissivity of an ACP can be determined independently, as an open instrument, the impact of the convection term is minor in steady-state conditions but significant when the base of the instrument is being subjected to rapid artificial cooling or heating. Using laboratory characterisation of the transmission and emissivity, together with use of an estimated solar calibration of the thermopile, generated mean differences of less than 1.5 Wm -2 to the two IRIS radiometers. A minimisation method using each IRIS radiometer as the reference also provided similar results, and the derived thermopile responsivity was within 0.3 µV W -1 m 2 of the solar-calibration-derived infrared responsivity estimate of 10.5 µV W -1 m 2 estimated using a nominal solar calibration and provide irradiances within ±2 % of the terrestrial irradiance measured by the reference pyrgeometers traceable to the International System of Units (SI). The calibration method using linear least squares regression introduced by Reda et al. (2012) that relies on rapid cooling of the ACP base but utilising the new equation was found to produce consistent results but was dependent on the assumed temperature of the air above the thermopile. This study demonstrates the potential of the ACP as another independent reference radiometer for terrestrial irradiance once the magnitude of the convection coefficient and any potential variations in it have been resolved.

47 OTHER INSTRUMENTATION↗

Optimization of the number and locations of the calibration stations needed to monitor soil moisture using distributed temperature sensing systems: A proof-of-concept study

The single-probe heat-pulse (SPHP) technique combined with the Fiber-optic Distributed Temperature Sensing (DTS) technology can offer novel high-resolution measurements of soil moisture (θ) over spatial scales ranging from several centimeters to several kilometers. However, the key limitation of this method is in obtaining the calibration relationship between θ and soil thermal conductivity (λ) across a specific field. In a previous study, a new methodology using a Gaussian processes model was presented to account for the spatial variability in the λ-θ relationship. The model aggregated θ measurements from soil moisture sensors scattered over the SPHP transect with the corresponding DTS λ measurements at their locations. In this study, a novel methodology is tested to optimize the number and locations of soil moisture sensors required to account for the spatial variability of the λ - θ relationship to achieve higher accuracy from the SPHP technique. The proposed methodology utilizes hierarchical clustering to analyze the information contained in the spatial structure of the SPHP measurements as the soil dries from a nearly-saturated condition. The proposed methodology was tested using data from a field in Oklahoma. Monte-Carlo simulation was performed to validate the performance of the proposed methodology. The predictions obtained from the proposed methodology resulted in θ measurements accuracy comparable to those obtained from the 10% best Monte-Carlo iterations of randomly assigned soil moisture locations. Further, this study demonstrates that the proposed methodology is more efficient than the traditional practice of randomly spreading calibration soil moisture sensors along the SPHP transect.

54 ENVIRONMENTAL SCIENCES↗

SuperCam Calibration Targets: Design and Development

Abstract SuperCam is a highly integrated remote-sensing instrumental suite for NASA’s Mars 2020 mission. It consists of a co-aligned combination of Laser-Induced Breakdown Spectroscopy (LIBS), Time-Resolved Raman and Luminescence (TRR/L), Visible and Infrared Spectroscopy (VISIR), together with sound recording (MIC) and high-magnification imaging techniques (RMI). They provide information on the mineralogy, geochemistry and mineral context around the Perseverance Rover. The calibration of this complex suite is a major challenge. Not only does each technique require its own standards or references, their combination also introduces new requirements to obtain optimal scientific output. Elemental composition, molecular vibrational features, fluorescence, morphology and texture provide a full picture of the sample with spectral information that needs to be co-aligned, correlated, and individually calibrated. The resulting hardware includes different kinds of targets, each one covering different needs of the instrument. Standards for imaging calibration, geological samples for mineral identification and chemometric calculations or spectral references to calibrate and evaluate the health of the instrument, are all included in the SuperCam Calibration Target (SCCT). The system also includes a specifically designed assembly in which the samples are mounted. This hardware allows the targets to survive the harsh environmental conditions of the launch, cruise, landing and operation on Mars during the whole mission. Here we summarize the design, development, integration, verification and functional testing of the SCCT. This work includes some key results obtained to verify the scientific outcome of the SuperCam system.

Manrique, J. A. (ORCID:0000000220532819)↗