Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system analysis module”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

MFVI Energy Efficiency Audit Training Module 2.2: Plug Loads Analysis [Slides]

This guide is designed to help trained energy efficiency professionals conduct an energy efficiency audit for commercial and industrial buildings, particularly for micro-, small-, and medium-sized businesses in Mexico. This guide is focused on auditing plug load systems. As such, it will assist its user in documenting the plug loads in the space and then identifying the most efficient means of delivering those plug loads.

21CPP↗

Silica-copper catalyst interfaces enable carbon-carbon coupling towards ethylene electrosynthesis

Membrane electrode assembly (MEA) electrolyzers offer a means to scale up CO 2 -to-ethylene electroconversion using renewable electricity and close the anthropogenic carbon cycle. To date, excessive CO 2 coverage at the catalyst surface with limited active sites in MEA systems interferes with the carbon-carbon coupling reaction, diminishing ethylene production. With the aid of density functional theory calculations and spectroscopic analysis, here we report an oxide modulation strategy in which we introduce silica on Cu to create active Cu-SiO x interface sites, decreasing the formation energies of OCOH* and OCCOH*—key intermediates along the pathway to ethylene formation. We then synthesize the Cu-SiO x catalysts using one-pot coprecipitation and integrate the catalyst in a MEA electrolyzer. By tuning the CO 2 concentration, the Cu-SiO x catalyst based MEA electrolyzer shows high ethylene Faradaic efficiencies of up to 65% at high ethylene current densities of up to 215 mA cm -2 ; and features sustained operation over 50 h.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Novel, Low-Cost, Portable Device for Counterfeit and Noncompliant Refrigerant Detection

The increasing prevalence of counterfeit refrigerants presents significant risks to Heating, Ventilation, Air Conditioning, and Refrigeration (HVACR) systems, including compromised equipment performance, safety hazards, and environmental non-compliance. This report details the development of a novel, cost-effective, and portable detection device designed to accurately identify counterfeit refrigerants. The device utilizes a controlled gas sampling and analysis system within a sealed chamber, ensuring precise measurements while maintaining safety through a purging mechanism. The system features a high-sensitivity sensor integrated with an onboard control module that analyzes gas composition in real-time, providing users with clear visual indicators for refrigerant authenticity.Laboratory validation demonstrated the device’s high accuracy (exceeding 95%) in detecting unauthorized refrigerant blends. Key advantages include affordability, ease of use, rapid response time, and compatibility with a wide range of refrigerants. This solution supports compliance with regulatory frameworks such as the American Innovation and Manufacturing (AIM) Act, enhances safety in HVACR operations, and mitigates the risks associated with counterfeit refrigerants. Future developments will focus on expanding refrigerant detection capabilities, integrating machine learning for enhanced accuracy, implementing cost-reduction strategies to improve accessibility and market adoption, and optimizing system packaging for enhanced field portability.

99 GENERAL AND MISCELLANEOUS↗

A Novel, Low-Cost, Portable Device for Counterfeit and Noncompliant Refrigerant Detection

The increasing prevalence of counterfeit refrigerants presents significant risks to Heating, Ventilation, Air Conditioning, and Refrigeration (HVACR) systems, including compromised equipment performance, safety hazards, and environmental non-compliance. This report details the development of a novel, cost-effective, and portable detection device designed to accurately identify counterfeit refrigerants. The device utilizes a controlled gas sampling and analysis system within a sealed chamber, ensuring precise measurements while maintaining safety through a purging mechanism. The system features a high-sensitivity sensor integrated with an onboard control module that analyzes gas composition in real-time, providing users with clear visual indicators for refrigerant authenticity. Laboratory validation demonstrated the device’s high accuracy (exceeding 95%) in detecting unauthorized refrigerant blends. Key advantages include affordability, ease of use, rapid response time, and compatibility with a wide range of refrigerants. This solution supports compliance with regulatory frameworks such as the AIM Act, enhances safety in HVACR operations, and mitigates the risks associated with counterfeit refrigerants. Future developments will focus on expanding refrigerant detection capabilities, integrating machine learning for enhanced accuracy, implementing cost-reduction strategies to improve accessibility and market adoption, and optimizing system packaging for enhanced field portability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hardware, methodology and applications of 2 + D backscatter Mössbauer spectroscopy with simultaneous x-ray and γ-ray detection

Abstract A unique method is presented for the acquisition and analysis of 57 Fe backscatter Mössbauer spectra with simultaneous detection of the resonant 14.4 keV γ -rays and the characteristic 6.4 keV x-rays, using a custom-built multi-parameter analyser constructed on the basis of commercial analogue to digital converters and high-speed digital latches. The system allows for the simultaneous registration of Doppler-modulation velocities and photon energies, with up to 4096 and 8192 digital channels respectively. This arrangement is in contrast to most related systems, which detect at a single narrow energy window per detector. Samples of arbitrary atomic structure, morphology and surface topography can be studied without altering the setup or the analysis procedure, provided that the samples are at least micrometre sized. The hardware and software that are used to acquire data with minimal dead time are described and the custom and self-contained methods for post-measurement energy discrimination, background correction and velocity-axis folding are discussed. The data are fit using a general Hamiltonian model for the nuclear energy levels of 57 Fe and a quantum mechanical description of the angular momentum coupling is utilised, with consideration of the crystalline and chemical disorder of the sample under examination. Three examples of distinct magnetic systems, with thicknesses ranging from 5 μ m to 6 mm, that were studied using this method are presented, these are: an amorphous CoFeB-based ribbon with ultra-soft coercivity for high-frequency applications, magnetically hard Nd-Fe-B thick films on Si substrates, examined in both as-deposited and annealed states, and a sample from the nickel-rich iron meteorite NWA 6259 that contains the atomically ordered, elevated coercivity, L 1 0 phase of FeNi, tetrataenite. The wide applicability and usefulness of this method is thus demonstrated on three distinct sample morphologies that required little to no surface preparation prior to examination.

Engineering↗

Quasinormal Coupled-Mode Analysis of Dynamic Gain in Exceptional-Point Lasers

One of the key features of lasers operating near exceptional points (EPs) is that the gain medium can support an oscillating population inversion above a pump threshold, leading to self-modulated laser dynamics. This unusual behavior opens up new possibilities for frequency comb generation and temporal modulation. However, the dynamic population inversion couples signals with different frequencies and is difficult to capture using conventional temporal coupled-mode theory (TCMT) based on stationary saturable gain. In this paper, we develop a perturbative coupled-mode analysis framework to capture the spatial-temporal dynamics of near-EP lasers. By decomposing discrete frequency generation into multiple excitations of resonant modes, our analysis establishes a minimal physical model that translates the local distribution of dynamic population-inversion into a resonant modal interpretation of laser gain. Furthermore, this work enables the exploration of unique properties in this self-time-modulated systems, such as time-varying scattering and nonreciprocal transmission.

Absorption↗

Influence of isoelectronic mass modulation on phonon decay and transport in layered pnictogen-carbon systems

This study systematically investigates the structural, electronic, and thermal transport properties of layered pnictogen–carbon (Pn 2 C 2 ; Pn = P, As, Sb, Bi) monolayers, revealing a profound influence of isoelectronic mass modulation on phonon dynamics and thermal conductivity. Through first-principles calculations and lattice dynamics analysis, we demonstrate that increasing the atomic mass of pnictogens leads to elongated Pn-C bonds, weakened interatomic interactions, and enhanced phonon-phonon scattering, resulting in a dramatic reduction in lattice thermal conductivity (κ). Specifically, κ decreases exponentially from 65.6 W/m-K in P 2 C 2 to an ultralow 0.37 W/m-K in Bi 2 C 2 , driven by suppressed acoustic-optical phonon gaps Δ$^{Γ}_{A-0}$, increased anharmonicity, and reduced phonon lifetimes and group velocities. The transition from semiconducting to metallic behavior in heavier pnictogen-based systems further enhances phonon-electron scattering, contributing to thermal conductivity suppression. Structural analysis highlights the strengthening of out-of-plane C—C bonds and the contraction of C—Pn—C bond angles, which disrupt in-plane phonon transport. Further, these findings establish a design framework for engineering ultralow-κ materials through chemical substitution and structural tuning, offering significant potential for thermoelectric and thermal management applications. This work provides fundamental insights into phonon decay mechanisms and thermal transport in 2D materials, paving the way for advanced phononic and energy-efficient devices.

2D materials↗

Muon radiography applied to volcanoes imaging: the MURAVES experiment at Mt. Vesuvius

Muon radiography is a technique based on the measurement of absorption profiles of muons as they pass through matter. This measurement allows to obtain an image of the inner structure of large volume objects and is suitable to be applied in several fields, such as volcanology, archaeology and civil engeneering. One of the main applications concerns the study of volcanic structures; indeed it is possible to use this technique to measure the mass distribution inside the edifice of a volcano providing useful information to better understand the possible eruption mechanisms. The MURAVES (MUon RAdiography of VESuvius) project aims to the study of the summital cone of Mt. Vesuvius near Naples in Italy, one of the most dangerous active volcanoes in the world. The MURAVES apparatus is a modular, robust muon hodoscope system with a low power consumption, optimized to be used in inhospitable environments like the surroundings of volcanoes. The complete detection system is an array of identical tracking modules, each with an area of 1 m2, based on the use of plasic scintillators. The technologies, the status and the data analysis strategy of the experiment will be presented in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Light and Elevated Temperature Induced Degradation (LeTID) in a Utility-Scale Photovoltaic System

Here, we present a detailed case study of degradation in monocrystalline silicon photovoltaic modules operating in a utility-scale power plant over the course of approximately three years. We present the results of degradation analysis on arrays within the site, and find that five of the six arrays degraded faster than the best performing array, even though the arrays consist of modules of the same manufacturer and model. We also describe the results of extensive laboratory characterization of modules returned from the field, including module- and cell-level current–voltage characterization, luminescence imaging, and accelerated testing. The laboratory test results and the field performance are consistent with light and elevated temperature induced degradation (LeTID). Notably, we observe differences in back contact technology between affected and unaffected modules. This article also demonstrates a method to identify possible LeTID degradation in the field and confirm the result with laboratory testing of a small number of modules.

14 SOLAR ENERGY↗

Analytic Thermal Model of an Optical Fiber Based Gamma Thermometer and its Application in a University Research Reactor

This paper describes and validates, by comparison with numerical modeling results, an analytical model of thermal transport in an optical fiber based gamma thermometer (OFBGT) that is appropriate for use in university research reactors. The maximum temperature difference between the thermal mass and the outer sheath ( &#x0394;<!-- Δ --> T ) for the OFBGT design that we have considered is approximately 50 &#x2218;<!-- ° --> C , for the OFBGT in the Central Irradiation Facility of the Ohio State University Research Reactor (OSURR) with the reactor operating at full power (450 kW). The maximum value of &#x0394;<!-- Δ --> T that is predicted by the analytic model for the OFBGT design is smaller by approximately 1.1 °C than the value of &#x0394;<!-- Δ --> T which is predicted by the numerical model, for the same OFBGT design, but including all the details of the design. We have used the analytical model of thermal transport in an OFBGT to determine a normalized Modulation Transfer Function M T F &#x2032; ( k ) ) for the OFBGT. We conclude that MTF &#x2032;<!-- ' --> ( k OSU ) > 0.99 , where k OSU is the spatial frequency for the axial dependence of the reactor power distribution in the

47 OTHER INSTRUMENTATION↗

Exploring the Atmospheric Dynamics of the Extreme Ultrahot Jupiter KELT-9b Using TESS Photometry

We carry out a phase-curve analysis of the KELT-9 system using photometric observations from NASA’s Transiting Exoplanet Survey Satellite (TESS). The measured secondary eclipse depth and peak-to-peak atmospheric brightness modulation are 650{sub −15}{sup +14} and 566 ± 16 ppm, respectively. The planet’s brightness variation reaches maximum 31 ± 5 minutes before the midpoint of the secondary eclipse, indicating a 5.°2 ± 0.°9 eastward shift in the dayside hot spot from the substellar point. We also detect stellar pulsations on KELT-9 with a period of 7.58695 ± 0.00091 hr. The dayside emission of KELT-9b in the TESS bandpass is consistent with a blackbody brightness temperature of 4600 ± 100 K. The corresponding nightside brightness temperature is 3040 ± 100 K, comparable to the dayside temperatures of the hottest known exoplanets. In addition, we detect a significant phase-curve signal at the first harmonic of the orbital frequency and a marginal signal at the second harmonic. While the amplitude of the first harmonic component is consistent with the predicted ellipsoidal distortion modulation assuming equilibrium tides, the phase of this photometric variation is shifted relative to the expectation. Placing KELT-9b in the context of other exoplanets with phase-curve observations, we find that the elevated nightside temperature and relatively low day–night temperature contrast agree with the predictions of atmospheric models that include H{sub 2} dissociation and recombination. The nightside temperature of KELT-9b implies an atmospheric composition containing about 50% molecular and 50% atomic hydrogen at 0.1 bar, a nightside emission spectrum that deviates significantly from a blackbody, and a 0.5–2.0 μm transmission spectrum that is featureless at low resolution.

79 ASTRONOMY AND ASTROPHYSICS↗

Serpent - Bison - THM Preliminary Multiphysics Modeling of a Nuclear Thermal Propulsion System Fuel Assembly

This work demonstrates the Monte Carlo neutronic and Thermo-Hydraulic coupling scheme using the Serpent code and MOOSE application Bison and Thermo Hydraulic Module. The coupling scheme is then applied to the reference BWX Technologies Nuclear Ther- mal Propulsion system at he fuel assembly level where it’s used to perform an analysis of the isothermal material coefficients and potential material reactivity worth. A method is developed to isolate which feedback effects should be considered for proceeding with reduced order deterministic neutronic modeling where branch off analysis must be con- ducted. The convergence behavior of the coupling scheme is demonstrated where it fol- lows the standard Picard iteration approach. Verification studies for the method of deduc- ing relevant feedback effects is also demonstrated.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Comparative Analysis of Direct and Indirect Cooling of Wide-Bandgap Power Modules and Performance Enhancement of Jet Impingement-Based Direct Substrate Cooling

With the development of high-power and high-torque machines, requirements for high-power density electronics are increasing. Thermal management of such systems requires high heat extraction. Conventional air cooling based heat sinks and cold plate based liquid cooling have their own benefits for various applications but has limitations for high power density applications. The current study explores a jet impingement based direct substrate cooling system that was implemented for a SiC based direct bonded Cu substrate for various power losses. Numerical comparison between jet impingement cooling and conventional horizontal/indirect cooling (pin fin heat sink and genetic algorithm-optimized heat sink) showed that the area weighted average of the heat transfer coefficient (HTC) is high for both horizontal cooling designs, and the local HTC is higher for jet impingement. Design iterations were undertaken to resolve the bottleneck of this cooling system. Increasing the number of nozzles helped to cover more area at the direct bonded Cu bottom plate, which drops the chip temperature considerably. With a constant flow rate, increasing the number of nozzles would decrease local jet velocity, which reduces the heat extraction by jet impingement. This issue can be addressed by reducing the diameter of nozzle but doing so results in a high pressure drop where the design constraint is 2 psi. A flared nozzle design is proposed, which has a higher spreading angle of the jet that increases the flow coverage and reduces the pressure drop of the coolant loop.

Barua, Himel↗

Development of a Reference Design for a Cyber-Physical System

The purpose of this thesis is to develop a reference design to assist in the selection of security practices in power electronics design. A prototype will be developed from this reference design for evaluation. This evaluation will include a brief cost/benefit analysis to gauge the efficacy of implementing each layer of security throughout the power electronics design process. This thesis will also describe the obstacles and effectiveness of integrating a Trusted Platform Module (TPM) into a cyber-hardened grid-connected device. The TPM device is a secured crypto processor that assists in generating, storing, and restricting the use of cryptographic keys. The emphasis of this research is to establish integrity, authenticity, and confidentiality within a system by providing a baseline of security concerns for segments of the system. This research considers communication, control, and hardware level securities. The scope of this thesis will review the necessary security methods as well as consider the effects these methods have on the embedded system, to assess the desired security to responsiveness trade off. Applying this approach to a design process will alleviate various unknowns of appending security to a power electronics design. This thesis describes the specific vulnerabilities introduced within this grid-edge environment, and how the liabilities within the system can be mitigated. Initially, common security techniques will be considered to establish a guideline to benchmark performance and resource costs of the system. The foundation will be a non-hardened power electronic system platform with industry standard communication protocols. Several security techniques and attack vectors will then be evaluated to contribute to the base level platform. Other fail-safe features take place to gauge progress of the selected approach, non-inclusive to the TPM. Collectively, this investigation will determine a valid experiment by appraising and categorizing resource allocation, performance overhead, and monetary cost analysis results into a reference design. The prototype will then demonstrate methods to relieve common threats that are purposefully implemented into the design.

Blair, Nicholas Paul↗

Dynamic PRA-Based Estimation of PWR Coping Time Using a Surrogate Model for Accident Tolerant Fuel

In this study, we propose an interpolation-based response surface surrogate methodology to manage a large number of scenarios in dynamic probabilistic risk assessment. It adopts the shape Dynamic Time Warping algorithm to cluster the interpolation neighborhood from time series sample data. The interpolation method was adapted from Taylor Kriging to allow a reduced-order model of the Taylor series. In order to demonstrate its applicability to complex issues in risk assessment for nuclear engineering, an example risk response surface to estimate emergency core cooling system (ECCS) criteria for triplex silicon carbide (SiC) accident-tolerant fuel was constructed. The response surface was exploited to estimate the cumulative failure probability of the fuel cladding structure due to the uncertainties in operator actions and safety systems. The functional failures were assessed based on a combination of individual layer failures computed by coupling Risk Analysis Virtual Environment software with a pressurized water reactor 1000-MW(electric) RELAP5 model and the in-house fuel performance assessment module. Results showed that SiC cladding failure probability spiked less than 1 min after a large-break loss-of- coolant accident whenever the current ECCS criteria for Zircaloy-4 (Zr-4) cladding was used. However, it still provides an increased safety margin of three orders of magnitude compared to Zr-4. This positive margin could be utilized to relax active ECCS requirements by allowing deviations of up to 450 s in its actuation time. The proposed surrogate methodology generated a response surface of SiC cladding failure probability reasonably well, with a significant savings of computation time. This methodology is expected to be useful in the analysis of system response with complex uncertainty sources.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Theorems in Service of Sound Composition, Rapid Modeling and Scalable Analysis

This project extends the state of the art in formal verification modeling with modules and automatically checkable data-sharing patterns such that component modules can retain their assurance case when composed within a larger system. For users, smaller models make reasoning easier and help to ensure they accurately reflect text specifications. For automated methods, smaller models give exponential benefits for verification algorithm execution time.

97 MATHEMATICS AND COMPUTING↗

Fundamental insights on ignition and combustion of natural gas in an active fueled pre-chamber spark-ignition system

Pre-chamber spark-ignition (PCSI), either fueled or non-fueled, is a leading concept with the potential to enable diesel-like efficiency in medium-duty (MD) and heavy-duty (HD) natural gas (NG) engines. However, the inadequate scientific base and simulation tools to describe/predict the underlying processes governing PCSI systems is one of the key barriers to market penetration of PCSI for MD/HD NG engines. To this end, experiments were performed in a heavy-duty, optical, single-cylinder engine fitted with an active fueled PCSI module. Furthermore, the spatial and temporal progress of ignition and subsequent combustion of lean-burn natural gas using PCSI system were studied using optical diagnostic imaging and heat release analysis based on main-chamber and pre-chamber pressure measurements.

42 ENGINEERING↗