Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “suspensions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

A preliminary investigation of the dynamic force-calibration of a magnetic suspension and balance system

The aerodynamic forces and moments acting upon a magnetically suspended wind tunnel model are derived from calibrations of suspension electro magnet currents against known forces. As an alternative to the conventional calibration method of applying steady forces to the model, early experiences with dynamic calibration are outlined, that is a calibration obtained by oscillating a model in suspension and deriving a force/current relationship from its inertia force and the unsteady components of currents. Advantages of dynamic calibration are speed and simplicity. The two methods of calibration applied to one force component show good agreement.

Goodyer, M. J.↗

Study on needs for a magnetic suspension system operating with a transonic wind tunnel

The U.S. aeronautical industry was surveyed to determine if current and future transonic testing requirements are sufficient to justify continued development work on magnetic suspension and balance systems (MSBS) by NASA. The effort involved preparation of a brief technical description of magnetic suspension and balance systems, design of a survey form asking specific questions about the role of the MSBS in satisfying future testing requirements, selecting nine major aeronautics companies to which the description and survey forms were sent, and visiting the companies and discussing the survey to obtain greater insight to their response to the survey. Evaluation and documentation of the survey responses and recommendations which evolved from the study are presented.

Martindale, W. R.↗

Atrophy and growth failure of rat hindlimb muscles in tail-cast suspension

The primary objective of the present study is related to an evaluation of a modified tail-cast suspension model as a means of identifying metabolic factors which control or are associated with muscle atrophy and growth failure. Two different control conditions (normal and tail-casted weight bearing) were studied to determine the appropriate control for tail-cast suspension. A description is presented of a model which is most useful for studying atrophy of hindlimb muscles under certain conditions. Female Sprague-Dawley rats were employed in the experiments. Attention is given to growth rate and urinary excretion of urea and ammonia in different types of rats, the relationship between body weight and skeletal muscle weight, and the relationship between animal body weight and rates of protein synthesis and protein degradation.

Jaspers, S. R.↗

An airfoil flutter model suspension system to accommodate large static transonic airloads

A pitch/plunge flutter model suspension system and associated two-dimensional MBB-A3 airfoil models is described. The system is designed for installation in the Langley 6-by-19-inch and 6-by-18-inch transonic blowdown wind tunnels to enable systematic study of the transonic flutter characteristics and static pressure distributions of supercritical airfoils at transonic Mach numbers. A compound spring suspension concept is introduced which simultaneously meets requirements for low plunge-mode stiffness, lightweight suspended model, and large steady lift due to angle of attack without the need for excessive static deflections of the plunge spring. The system features variable pitch and plunge frequencies, changeable airfoil rotation axes, and a self aligning control system to maintain a constant mean position of the model with changing airload.

Reed, W. H., III↗

Analytical determination of space station response to crew motion and design of suspension system for microgravity experiments

The objective of this investigation is to make analytical determination of the acceleration produced by crew motion in an orbiting space station and define design parameters for the suspension system of microgravity experiments. A simple structural model for simulation of the IOC space station is proposed. Mathematical formulation of this model provides the engineers a simple and direct tool for designing an effective suspension system.

Liu, F. C.↗

Effects of suspension hypokinesia/hypodynamia on rat skeletal muscle

The effects of suspension hypokinesia/hypodynamia (H/H) on properties of soleus and plantaris muscles of rats were studied. The objective was to compare the effects of this model to those of disuse atrophy. After 12 d of H/H, there were significant decreases in soleus and plantaris muscle wet weight and citrate synthase activity. Soleus muscle was affected to a greater extent than plantaris muscle. There was a significant decrease in noncollagen protein content of H/H soleus muscle. Triceps brachii muscles did not display significant changes in any parameters measured, suggesting that observed changes were not due to systemic factors. There was no significant change in the water content of H/H soleus or plantaris muscles. Suspension H/H causes muscle changes different from those secondary to limb immobilization, in which soleus and plantaris muscles are equally affected.

Max, S. R.↗

Responses of amino acids in hindlimb muscles to recovery from hypogravity and unloading by tail-cast suspension

Amino acids were assayed in muscles from rats exposed to 7 days of hypogravity and 12 h of gravity (F) or 6 days of suspension with (R) or without (H) 12 h of loading. In these groups, lower aspartate was common only to the soleus (SOL) relative to control muscles, the smallest difference being in group R. This difference in aspartate for F and H, but not for R, correlated with lower malate suggesting diminution of citric acid cycle intermediates. The R SOL value was increased over the H SOL. Therefore desite 12 h of loading, the F SOL was more comparable to the H SOL. The role of stress in preventing recovery of the F SOL was apparent from the ratios of glutamine/glutamate. Synthesis of glutamine is enhanced by glucocorticoids and is reflected by an increased ratio. In 5 of the 6 F muscles studied, this ratio was greater than in controls. In contrast, the ratio in all R muscles was similar to controls and showed recovery from the values in H muscles. Hence the post-flight treatment of F rats may have produced additional stress. Despite this stress, in some respects the SOL responses to hypogravity were similar to its responses to unloding by suspension.

Tischler, M. E.↗

Analytical determination of space station response to crew motion and design of suspension system for microgravity experiments

The objective of this investigation is to make analytical determination of the acceleration produced by crew motion in an orbiting space station and define design parameters for the suspension system of microgravity experiments. A simple structural model for simulation of the IOC space station is proposed. Mathematical formulation of this model provides the engineers a simple and direct tool for designing an effective suspension system.

Liu, Frank C.↗

Airfoil flutter model suspension system

A wind tunnel suspension system for testing flutter models under various loads and at various angles of attack is described. The invention comprises a mounting bracket assembly affixing the suspension system to the wind tunnel, a drag-link assembly and a compound spring arrangement comprises a plunge spring working in opposition to a compressive spring so as to provide a high stiffness to trim out steady state loads and simultaneously a low stiffness to dynamic loads. By this arrangement an airfoil may be tested for oscillatory response in both plunge and pitch modes while being held under high lifting loads in a wind tunnel.

Reed, Wilmer H.↗

Electrokinetic properties of particles in concentrated suspensions

The electrokinetic behavior of concentrated suspensions is studied under conditions where the double layer is thin. Bulk electrical conductivity and single particle electrophoretic mobilities were studied as functions of the particle concentration in the suspension. It is found that the interactions between particles affect the conduction processes.

Zukoski, C. F.↗

Large-Angle Magnetic Suspension (LAMS)

Spherical LAMS is magnetic syspension that provides dual functions of magnetic bearing and rotorgimbal system. Provides two degrees of angular freedom within single magnetic suspension system. Approach employs spherically-shaped magnetic-gap surfaces to achieve much-larger angular freedom than available from previous suspensions.

Oglevie, Ronald E.↗

Status of magnetic suspension technology

The reasons for the continuing interest in the Magnetic Suspension and Balance System (MSBS) are highlighted. Typical problems that can arise because of model-support interference in a transonic wind tunnel are shown to illustrate the need for MSBS. The two magnetic suspension systems in operation at Langley are the only ones active in the U.S. One of these systems is the 13 inch MSBS which was borrowed from the Air Force Arnold Engineering Development Center. The other system is the 6 inch MSBS which was developed by MIT Aerophysics Laboratory with NASA and DOD funding. Each of these systems is combined with a subsonic wind tunnel. Ongoing research in both of these systems is covered. Last year, Madison Magnetics, Inc., completed a contractual design and cost study utilizing some advance concepts for a large MSBS which would be compatible with an 8 foot transonic wind tunnel and the highlights of the study are presented. Sverdrup Technology, Inc., recently performed a study under contract for Langley on the potential usefulness to the aerospace industry of a proposed large MSBS combined with a suitable transonic wind tunnel. The results of that study are discussed. Langley has partially funded the MSBS work at the University of Southampton for about 6 years under a grant arrangement and the major results are summarized.

Boyden, Richmond P.↗

Physiological comparison of rat muscle in body suspension and weightlessness

Hind limb unloading is achieved with whole body suspension (WBS) and with tail suspension (TS). Comparable levels of muscle mass loss and decreases in protein levels result during one to three weeks of exposure to microgravity (microG), WBS, and TS. Losses are most apparent in soleus (S), intermediate in gastrocnemius (G) and least in extensor digigorum longus (EDL). Comparison of S and EDL type I and II fiber changes (numbers and area) after seven days of microG flight and WBS showed, in S, an increase in Type I and Type II fiber density and a decrease in area. Except for a decrease in Type I fiber density in EDL, all other parameters remained comparable. The general conclusions were that the S under microG and WBS responds in a similar manner. The EDL, for the most part, shows little change under both conditions.

Musacchia, X. J.↗

Debarment and suspension

The changing Government attitude toward contractor debarment and suspension is examined, with emphasis on the fact that the Government is more alert to fraud, waste, and abuse. Consideration is given to causes of debarment or suspension, procedures and due process hearings, settlement agreements, compliance programs, and recent related legislation. It is concluded that the change in the Government contracting environment in recent years should be sufficient incentive for contractors to monitor their operations more closely.

Whelan, Thomas J.↗

The nonlinear behavior of a passive zero-spring-rate suspension system

Various concepts for advanced syspension systems have been proposed for counteracting gravity loads in ground vibration testing of large space structures. Approximating the flight modes of a low-frequency flexible structure in a ground test requires a very soft suspension system. The dynamic behavior of a passive zero-spring-rate mechanism, sometimes used for such ground testing, is analyzed. This mechanism reduces the stiffness inherent in suspending a test specimen by cables. However, the mechanism is shown to be sensitive to imperfections. Imperfections can initiate nonlinear behavior which becomes more pronounced at lower operating frequencies. Furthermore, large pendular motion of the suspension system couples with the vertical motion, producing additional nonlinearity.

Woodard, Stanley E.↗

A forecast of new test capabilities using Magnetic Suspension and Balance Systems

This paper outlines the potential of Magnetic Suspension and Balance System (MSBS) technology to solve existing problems related to support interference in wind tunnels. Improvement of existing test techniques and exciting new techniques are envisioned as a result of applying MSBS. These include improved data accuracy, dynamic stability testing, two-body/stores release testing, and pilot/designer-in-the-loop tests. It also discusses the use of MSBS for testing exotic configurations such as hybrid hypersonic vehicles. A new facility concept that combines features of ballistic tubes, magnetic suspension, and cryogenic tunnels is described.

Lawing, Pierce L.↗

Adaptation of bone and tendon to prolonged hindlimb suspension in rats

The effect of a sustained deprivation of ground reaction forces on mineralized and soft connective tissues was investigated in rats subjected to 28-d-long hind-limb suspension. The results of morphological and biochemical studies carried out on femurs and patellar tendons obtained from suspended and nonsuspended 110-d-old rats showed that prolonged suspension led to an increase of the minimum diameter of the femur middiaphysis (by 12 percent), without any significant alterations in cortical area, density, mineral and collagen concentrations, femur wet weight, length, and DNA and uronic acid concentrations. However, in the patellar tendons of suspended rats, the collagen and proteoglycan concentrations were 28 percent lower than in tendons obtained from nonsuspended animals. These results suggest that ground reaction forces are important for the maintenance of cortical bone and patellar tendon homeostasis during weight-bearing conditions.

Vailas, Arthur C.↗

Periodic weight support effects on rat soleus fibers after hindlimb suspension

The morphological and histochemical properties of rat soleus muscles were investigated following one week of hindlimb suspension. Short-duration daily weight support activity is shown to ameliorate, but not prevent, soleus atrophy induced by hindlimb suspension. The results indicate that fiber cross-sectional area is more responsive to periodic weight support in dark than light ATPas fibers, and that muscle fiber atrophy need not be associated with a loss in succinate dehydrogenase activity.

Hauschka, Edward O.↗