Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “stress testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Vamistor resistor investigation

Results are presented of the failure investigation conducted on resistors produced by the Vamistor Divison, Wagner Electric Corporation. This failure investigation included; failure analyses, chemical and metallurgical analyses, failure mechanism studies, seal leak analyses, and nondestructive stress tests. The data, information, conclusions, and recommendation can be helpful in assessing current usage of these resistors.

Source record↗

Diffusional creep and creep-degradation in dispersion-strengthened Ni-Cr base alloys.

Dispersoid-free regions were observed in the dispersion-strengthened alloy TD-NiCr (Ni-20 Cr-2 ThO2) after slow strain rate testing (stress rupture, creep, and fatigue) in air from 1145 to 1590 K. Formation of the dispersoid-free regions appears to be the result of diffusional creep. The net effect of creep in TD-NiCr is the degradation of the alloy to a duplex microstructure. Creep degradation of TD-NiCr is further enhanced by the formation of voids and intergranular oxidation in the dispersoid-free bands. Void formation was observed after as little as 0.13% creep deformation at 1255 K. The dispersoid-free regions apparently provide sites for void formation and oxide growth since the strength and oxidation resistance of Ni-20 Cr-2 ThO2.

Whittenberger, J. D.↗

Lower body negative pressure: Third manned Skylab mission

The crew of the Skylab 4 Mission exhibited physiological changes during their 84-day mission that resembled but in several important areas did not reach the magnitude of changes exhibited in crewmen of the two earlier Skylab flights. At rest all three crewmen showed, in comparison to preflight levels, elevated mean systolic and pulse pressures and decreased mean diastolic and mean arterial pressures. Similar changes were seen in most Skylab 2 and Skylab 3 crewmen. While mean resting heart rates of both the Skylab 3 and Skylab 4 crews were elevated, those of the Skylab 2 crew were, however, lower than during preflight tests. Stressed heart rates followed previous patterns in being consistently elevated over preflight values. Postflight changes in cardiovascular parameters for the most part resembled those seen in previous crewmen of space missions. Their recovery to preflight limits occurred rapidly. In-flight data and subjective impressions of the crewmen confirmed that lower body negative pressure in weightlessness imposed a greater stress upon the cardiovascular system than in earth's gravity.

Johnson, R. L.↗

Evaluation of the electromechanical properties of the cardiovascular system

Cardiovascular electromechanical measurements were collected on returning Skylab crewmembers at rest and during both lower body negative pressure and exercise stress testing. These data were compared with averaged responses from multiple preflight tests. Systolic time intervals and first heart sound amplitude changes were measured. Clinical cardiovascular examinations and clinical phonocardiograms were evaluated. All changes noted returned to normal within 30 days postflight so that the processes appear to be transient and self limited. The cardiovascular system seems to adapt quite readily to zero-g, and more importantly it is capable of readaptation to one-g after long duration space flight. Repeated exposures to zero-g also appear to have no detrimental effects on the cardiovascular system.

Bergman, S. A., Jr.↗

On the effect of emotional states on operator thinking

A combination sonic and electrical skin stimuli stress test is reported that is suitable for the psychological selection of individuals to perform operator functions. The behavior of these people is characterized by a fighting spirit, increased work capacity, minimum expenditure of strength and insignificant fatigue.

Solodkova, A. V.↗

Theory to test comparisons for selected aerospace multishell structures and their interfaces under thermomechanical loadings

Guidelines for structural shell analyses were obtained on the basis of theory-to-test comparisons made on two large-scale aerospace structures subject to thermomechanical loads. The first structural test was the cylindrical aluminum skin-stringer-ring construction of the S-IC forward skirt and S-II interstage. The second structural test included the truncated, cone-shaped, bonded honeycomb sandwich shell of the Spacecraft Lunar Module Adapter; the cylindrical bonded aluminum honeycomb sandwich construction of the Instrument Unit; and the skin-stringer construction with rings and intercostals of the S-IVB forward skirt. Analyses were made for loadings simulating the flight environment. Elementary shear lag theory was superimposed on shell analysis for interface junctions between stages to obtain favorable theory-to-test stress comparisons.

Ferdie, R. D.↗

Fail-safe hydraulic shaker protection

Nine channel system controls acceleration and force on structure undergoing vibration stress testing. System has automatic and manually operative abort feature.

Woodbury, R. C.↗

Clinical aspects of crew health

While the primary goal of the Apollo Program was to land men on the moon and return them safely to Earth, there were other very important medical objectives. The earlier Mercury and Gemini programs bad raised some concerns about the health and safety of future crews. For example, the high metabolic energy expenditure of extravehicular activity during the Gemini missions was unexpected. Before Apollo astronauts could safely explore the lunar surface, reliable predictors of energy cost and real-time monitoring techniques had to be developed. Physiological changes were noted in individual crewmen, some more consistently than others. The most important of these changes was in cardiopulmonary status demonstrated by decreased exercise capacity, loss of red blood cell mass, and cardiovascular deconditioning demonstrated by a decrease in the effectiveness of antigravity cardiovascular responses during postflight stress testing.

W. Royce Hawkins↗

Changes in the performance characteristics of a GaAs near infrared light emitting diode when exposed to various current and thermal stresses

The changes that occurred in the optical and electrical characteristics of a near infrared, GaAs light emitting diode, when operated under various levels and combinations of current and thermal stresses are discussed. A total of forty parts were operated for two thousand hours under eight different sets of dc current and ambient temperature conditions. Degradation in the radiant optical power of these devices was thirty-four percent when operated at their rated current and an ambient temperature of 298K (25 C). Derating the current and/or the thermal stress reduced the degradation of this parameter in approximately a linear manner. All degraded devices behaved similarly, exhibiting rapid nonlinear degradation followed by a gradual linear degradation and finally a period of stable operation. An attempt was made to correlate initial device condition to degradation during stress testing, but met with little success.

Thomas, E. F., Jr.↗

Exercise cardiac output following Skylab missions - The second manned Skylab mission

Cardiac output was measured during preflight and postflight exercise-stress tests on the Skylab astronauts. In the postflight tests immediately following the 28-, 59-, and 84-d earth orbital missions, the astronauts exhibited an approximate 30% decrease in cardiac output coupled with an approximate 50% decrease in cardiac stroke volume during exercise. These changes were accompanied by elevated heart rates and significant increases in total systemic peripheral vascular resistance. Mean arterial pressure was unchanged. All parameters returned to normal preflight values within 30 d of the end of the orbital period. Duration of the zero-G exposure did not appear to influence either the magnitude of the hemodynamic changes or the time-course of their return to normal. These results are discussed in relation to other cardiovascular findings and possible mechanisms responsible for the observations are outlined.

Buderer, M. C.↗

Advanced acoustic and aerodynamic 20-inch fan program

The aerodynamic analyses, mechanical analyses, and stress tests of a 20-inch diameter advanced fan design intended for acoustic investigation by NASA-LeRC are discussed. A high tip speed transonic fan rotor was scaled directly to 20.0 inches (0.508 m) from a 28.74-inch (0.73-m) diameter rotor. A new stator was designed and fabricated for the fan and incorporated with a test rig housing and adapter hardware for installation in the NASA-LeRC Jet Noise Facility for acoustic evaluation. The stator was designed to allow mounting at three axial locations, and the fan, housing, and adapters are reversible so that either the inlet or the exhaust ends of the assembly face the open room of the test facility. Excellent aerodynamic performance is predicted, and a low noise signature is expected since the unique aerodynamic design features of this fan are directly conductive to producing minimum sound power.

Erwin, J. R.↗

Ceramic regenerator systems development program

Ceramic regenerator cores are considered that can be used in passenger car gas turbine engines, Stirling engines, and industrial/truck gas turbine engines. Improved materials and design concepts aimed at reducing or eliminating chemical attack were placed on durability test in Ford 707 industrial gas turbine engines. The results of 19,600 hours of turbine engine durability testing are described. Two materials, aluminum silicate and magnesium aluminum silicate, continue to show promise toward achieving the durability objectives of this program. A regenerator core made from aluminum silicate showed minimal evidence of chemical attack damage after 6935 hours of engine test at 800 C and another showed little distress after 3510 hours at 982 C. Results obtained in ceramic material screening tests, aerothermodynamic performance tests, stress analysis, cost studies, and material specifications are also included.

Cook, J. A.↗

Ceramic regenerator systems development program

Ceramic regenerator cores are considered that can be used in passenger car gas turbine engines, Stirling engines, and industrial/truck gas turbine engines. Improved materials and design concepts aimed at reducing or eliminating chemical attack were placed on durability tests/in industrial gas turbine engines. A regenerator core made from aluminum silicate shows minimal evidence of chemical attack damage after 7804 hours of engine test at 800 C and another showed little distress after 4983 hours at 982 C. The results obtained in ceramic material screening tests, aerothermodynamic performance tests, stress analysis, cost studies, and material specifications are also included.

Cook, J. A.↗

Systems identification and application systems development for monitoring the physiological and health status of crewmen in space

The use of automated, analytical techniques to aid medical support teams is suggested. Recommendations are presented for characterizing crew health in terms of: (1) wholebody function including physiological, psychological and performance factors; (2) a combination of critical performance indexes which consist of multiple factors of measurable parameters; (3) specific responses to low noise level stress tests; and (4) probabilities of future performance based on present and periodic examination of past performance. A concept is proposed for a computerized real time biomedical monitoring and health care system that would have the capability to integrate monitored data, detect off-nominal conditions based on current knowledge of spaceflight responses, predict future health status, and assist in diagnosis and alternative therapies. Mathematical models could play an important role in this approach, especially when operating in a real time mode. Recommendations are presented to update the present health monitoring systems in terms of recent advances in computer technology and biomedical monitoring systems.

Leonard, J. I.↗

Microprocessor-based cardiotachometer

Instrument operates reliably even with stress-test electrocardiogram (ECG) signals subject to noise, baseline wandering, and amplitude change. It records heart rate from preamplified, single-lead ECG input signal and produces digital and analog heart-rate outputs which are fed elsewhere. Analog hardware processes ECG input signal, producing 10-ms pulse for each heartbeat. Microprocessor analyzes resulting pulse train, identifying irregular heartbeats and maintaining stable output during lead switching. Easily modified computer program provides analysis.

Crosier, W. G.↗

Cardiopulmonary data acquisition system. Version 2.0, volume 1: User's guide

The Cardiopulmonary Data Acquisition System is a computerized method of both collecting and analyzing physiological data on subjects during a treadmill or ergometer stress test in the clinic. The real time acquisition of the physiological data, such as, heart rate, blood pressure, work load, and respiratory gases is accomplished by an LSI-11 microcomputer which displays this data on a hard copy terminal. The data are also concurrently stored on a mass storage device and anytime after the test period a selectable number of copies of the plots or minute reports can be reproduced at the terminal.

Source record↗

Ceramic regenerator systems development program

The DOE/NASA Ceramic Regenerator Design and Reliability Program aims to develop ceramic regenerator cores that can be used in passenger car and industrial/truck gas turbine engines. The major cause of failure of early gas turbine regenerators was found to be chemical attack of the ceramic material. Improved materials and design concepts aimed at reducing or eliminating chemical attack were placed on durability test in Ford 707 industrial gas turbine engines late in 1974. Results of 53,065 hours of turbine engine durability testing are described. Two materials, aluminum silicate and magnesium aluminum silicate, show promise. Five aluminum silicate cores attained the durability objective of 10,000 hours at 800 C (1472 F). Another aluminum silicate core shows minimal evidence of chemical attack after 8071 hours at 982 C (1800 F). Results obtained in ceramic material screening tests, aerothermodynamic performance tests, stress analysis, cost studies, and material specifications are included.

Fucinari, C. A.↗

Measurement of cardiopulmonary performance during acute exposure to a 2440-m equivalent atmosphere

Each of 20 subjects (ranging in age from 18 to 38 years, 15 being male, five female) was given two Bruce Protocol symptom-limited maximum treadmill stress tests, breathing sea-level compressed air (20.9% O2) for one test and a 2440-m equivalent (15.5% O2) for the other. A significant difference was found to exist between measured VO2 max (p less than 0.0002) and exercise time (p less than 0.0004) for the two conditions. No significant differences were observed in heart rate or the recovery time to a respiratory quotient of less than 1. Hemoglobin saturation, as measured by an ear oximeter, averaged 95% for sea-level and 91% for the 2440-m equivalent gases. These results support a 2440-m equivalent contingency atmosphere in the Space Shuttle prior to donning a low-pressure suit for the purpose reducing nitrogen washout times.

Levitan, B. M.↗