Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “strain imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Progress of a Cross-Correlation Based Optical Strain Measurement Technique for Detecting Radial Growth on a Rotating Disk

The Aeronautical Sciences Project under NASA's Fundamental Aeronautics Program is interested in the development of novel measurement technologies, such as optical surface measurements for the in situ health monitoring of critical constituents of the internal flow path. In situ health monitoring has the potential to detect flaws, i.e. cracks in key components, such as engine turbine disks, before the flaws lead to catastrophic failure. The present study, aims to further validate and develop an optical strain measurement technique to measure the radial growth and strain field of an already cracked disk, mimicking the geometry of a sub-scale turbine engine disk, under loaded conditions in the NASA Glenn Research Center's High Precision Rotordynamics Laboratory. The technique offers potential fault detection by imaging an applied high-contrast random speckle pattern under unloaded and loaded conditions with a CCD camera. Spinning the cracked disk at high speeds (loaded conditions) induces an external load, resulting in a radial growth of the disk of approximately 50.0-μm in the flawed region and hence, a localized strain field. When imaging the cracked disk under static conditions, the disk will be undistorted; however, during rotation the cracked region will grow radially, thus causing the applied particle pattern to be 'shifted'. The resulting particle displacements between the two images is measured using the two-dimensional cross-correlation algorithms implemented in standard Particle Image Velocimetry (PIV) software to track the disk growth, which facilitates calculation of the localized strain field. A random particle distribution is adhered onto the surface of the cracked disk and two bench top experiments are carried out to evaluate the technique's ability to measure the induced particle displacements. The disk is shifted manually using a translation stage equipped with a fine micrometer and a hotplate is used to induce thermal growth of the disk, causing the particles to become shifted. For both experiments, reference and test images are acquired before and after the induced shifts, respectively, and then processed using PIV software. The controlled manual translation of the disk resulted in detection of the particle displacements accurate to ~1.75% of full scale and the thermal expansion experiment resulted in successful detection of the disk's thermal growth as compared to the calculated thermal expansion results. After validation of the technique through the induced shift experiments, the technique is implemented in the Rotordynamics Lab for preliminary assessment in a simulated engine environment. The discussion of the findings and plans for future work to improve upon the results are addressed in the paper.

rotordynamics↗

Ring Pull Strain Analysis

Ring Pull Strain Analysis (RPSA) is a framework for analysis of Digital Image Correlation (DIC) data of gaugeless ring pull testing. It is meant for analysis of rings cut from tube cross sections and pulled in a displacement-controlled tensile test. This code takes load frame data, images take during testing, and csv files from the DIC analysis of those images and allows the user to analyze and plot data from the test. Some important features of the software include getting the strain values as a function of radial distance and angle, plotting of the strain around the ring, and stress-strain analysis of the load frame data.

Beck, Peter↗

Low-temperature state in strontium titanate microcrystals using in situ multireflection Bragg coherent x-ray diffraction imaging

Strontium titanate is a classic quantum paraelectric oxide material that has been widely studied in bulk and thin films. It exhibits a well-known cubic-to-tetragonal antiferrodistortive phase transition at 105 K, characterized by the rotation of oxygen octahedra. A possible second phase transition at lower temperature is suppressed by quantum fluctuations, preventing the onset of ferroelectric order. However, recent studies have shown that ferroelectric order can be established at low temperatures by inducing strain and other means. Here, we used in situ multireflection Bragg coherent x-ray diffraction imaging to measure the strain and rotation tensors for two strontium titanate microcrystals at low temperature. We observe strains induced by dislocations and inclusion-like impurities in the microcrystals. Based on radial magnitude plots, these strains increase in magnitude and spread as the temperature decreases. Pearson's correlation heat maps show a structural transition at 50 K, which could possibly be the formation of a low-temperature ferroelectric phase in the presence of strain. We do not observe any change in local strains associated with the tetragonal phase transition at 105 K.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dynamic fracture processes in hydrogen embrittled iron

Mechanistic understanding of hydrogen embrittlement is critical to the transport and storage of hydrogen as a sustainable fuel. Experimental observation of dynamic fracture processes in hydrogen environments has been challenging. Here, in-situ transmission X-ray microscopy is used to image polycrystalline iron foils that are concurrently strained and electrochemically charged with hydrogen. Using this technique, voids and microcracks down to ∼30 nm in size are identified at or near the crack tip and tracked as strain is increased. We observe both hydrogen-induced transgranular failure and hydrogen-induced intergranular failure with distinct fracture processes. We find that transgranular fracture occurs through the formation of sharp branched structures at the main crack tip that are reminiscent of slip band formation. This is followed by void growth and coalescence, and interaction with secondary cracks that lead to propagation of the main crack. Intergranular fracture is found to occur through void coalescence along grain boundaries, along with significant secondary cracking near the crack tip. The crack growth rate is greater for void-mediated intergranular failure than for slip-mediated transgranular failure. Additionally, the removal of hydrogen results in recovered ductility for a crack initially propagated under hydrogen charging.

36 MATERIALS SCIENCE↗

The physics of desiccation cracks 1: Ductile fracturing and dependence on relative humidity

Ductile deformation is ubiquitously found in the shrinkage of geomaterials. The existence of ductility requires elastoplastic mechanics when analyzing the structure deformation under external stress. Here, in this work, we explore the physics of ductile fracturing based on the results from desiccation experiments and triaxial tests. By using the digital image correlation (DIC) method to generate the strain maps of samples undergoing desiccation cracking under different relative humidities, we obtain results showing the previously postulated Cnoidal Wave ductile failure patterns propagating under atmospheric condition-controlled crack velocities. We then correlate these observations with rate-dependent plasticity models calibrated through triaxial tests undergoing several unloading–reloading cycles and velocity stepping. This work demonstrates the necessity to consider ductility in soil cracking, indicating that the formation of crack patterns in soil desiccation is a slow and predictable process.

58 GEOSCIENCES↗

In vitro activity and in vivo efficacy of omadacycline against Plasmodium species

Abstract Background Doxycycline is currently the only tetracycline-class antibiotic recommended for malaria prophylaxis. Omadacycline, a semisynthetic aminomethylcycline approved for treatment of adults with community-acquired bacterial pneumonia and acute bacterial skin and skin structure infections, has a well-established safety profile. This study evaluated the in vitro activity of omadacycline againstPlasmodium falciparumandPlasmodium cynomolgiand its in vivo efficacy againstPlasmodium bergheiin experimental malaria models to assess its potential as an antimalarial drug. Methods Fluorescence-based assays were used to assess the in vitro blood and liver stage activity of omadacycline and doxycycline againstP. falciparumandP. cynomolgilaboratory clones. In vivo liver and early-stage blood stage efficacy were evaluated in a murine model ofP. bergheiinfection, utilizing in vivo imaging of luciferase-expressingP. berghei(ANKA strain) sporozoites in female albino C57Bl/6 mice. Parasitaemia was monitored by flow cytometry for up to 30 days post-infection. Results Omadacycline demonstrated comparable in vitro activity to doxycycline against both drug-sensitive and drug-resistantP. falciparumclones, while doxycycline showed reduced activity against two drug-resistant clones. Notably, omadacycline exhibited superior anti-schizont activity in theP. cynomolgiliver stage assay. In theP. bergheimurine model, omadacycline was efficacious in both liver and early blood stages compared to the untreated control group, and demonstrated improved survival compared to doxycycline. Conclusions Omadacycline demonstrated enhanced antimalarial efficacy over doxycycline in vitro in liver stage activity and in overcoming resistance in the blood stage, and in survival in an in vivo model ofP. bergheiinfection. These findings support further investigation of omadacycline as a potential candidate for malaria prophylaxis and treatment.

Infectious Diseases↗

Sterilization of N95 Respirators via Gamma Radiation: Comparison of Post-sterilization Efficacy

This study evaluated gamma irradiation for sterilization and reuse of two models of N95 respirators after gamma radiation sterilization as a method to increase availability of N95 respirators during a shortage. The Sandia National Laboratories Gamma Irradiation Facility was used to irradiate two different models of N95 filtering facepiece respirators at doses ranging from 0 kGy(tissue) to 50 kGy(tissue). The following tests were used to determine the efficacy of the respirator after irradiation sterilization: Ambient Aerosol Condensation Nuclei Counter Quantitative Fit Test, tensile test, strain cycling, oscillatory dynamic mechanical analysis, microscopic image analysis of fiber layers, and electrostatic field measurements. Both of the respirator models exhibited statistically significant changes after gamma irradiation as shown by the Quantitative Fit Test, electrostatic testing and the aerosol testing. The change in electrostatic capability of the filter reduced the efficiency of challenging particles near the 200 nm size by approximately 40-50%. Both tested respirators showed statistically significant changes associated with gamma sterilization. However, our results indicate that choices in materials and manufacturing methods to achieve N95 filtration lead to different magnitudes of damage when exposed to gamma radiation at sterilization relevant doses. This damage results in lower filtration performance. While our sample size (2 different types of respirators) was small, we did observe a change in electrostatic properties on a filter layer that coincided with the failure on the Quantitative Fit Test.

61 RADIATION PROTECTION AND DOSIMETRY↗

Sterilization of N95 Respirators via Gamma Radiation: Comparison of Post-sterilization Efficacy

This study evaluated gamma irradiation for sterilization and reuse of two models of N95 respirators after gamma radiation sterilization as a method to increase availability of N95 respirators during a shortage. The Sandia National Laboratories Gamma Irradiation Facility was used to irradiate two different models of N95 filtering facepiece respirators at doses ranging from 0 kGy(tissue) to 50 kGy(tissue). The following tests were used to determine the efficacy of the respirator after irradiation sterilization: Ambient Aerosol Condensation Nuclei Counter Quantitative Fit Test, tensile test, strain cycling, oscillatory dynamic mechanical analysis, microscopic image analysis of fiber layers, and electrostatic field measurements. Both of the respirator models exhibited statistically significant changes after gamma irradiation as shown by the Quantitative Fit Test, electrostatic testing and the aerosol testing. The change in electrostatic charge of the filter was correlated with a reduction in capturing particles near the 200 nm size by approximately 40-50%. Both tested respirators showed statistically significant changes associated with gamma sterilization. However, our results indicate that choices in materials and manufacturing methods to achieve N95 filtration lead to different magnitudes of damage when exposed to gamma radiation at sterilization relevant doses. This damage results in lower filtration performance. While our sample size (2 different types of respirators) was small, we did observe a change in electrostatic properties on a filter layer that coincided with the failure on the Quantitative Fit Test and reduction in aerosol filtering efficiency. Key Words: N95 respirators, respirators, airborne transmission, pandemic prevention, COVID-19, gamma sterilization

COVID-19↗

Crystal Growth and Characterization of CdTe Grown by Vertical Gradient Freeze

In this study, crystals of CdTe were grown from melts by the unseeded vertical gradient freeze method. The quality of grown crystal were studied by various characterization techniques including Synchrotron White Beam X-ray Topography (SWBXT), chemical analysis by glow discharge mass spectroscopy (GDMS), low temperature photoluminescence (PL), and Hall measurements. The SWBXT images from various angles show nearly strain-free grains, grains with inhomogeneous strains, as well as twinning nucleated in the shoulder region of the boule. The GDMS chemical analysis shows the contamination of Ga at a level of 3900 ppb, atomic. The low temperature PL measurement exhibits the characteristic emissions of a Ga-doped sample. The Hall measurements show a resistivity of 1 x l0(exp 7) ohm-cm at room temperature to 3 x 10(exp 9) ohm-cm at 78K with the respective hole and electron concentration of 1.7 x 10(exp 9) cm(exp -3) and 3.9 x 10(exp 7) cm(exp -3) at room temperature.

Su, Ching-Hua↗

Experimental Methods in Materials for Structural Impact Dynamics

Over the past two decades significant technological advances have completely changed the way in which experimental testing is conducted in Structural Impact Dynamics applications. Probably the two most significant advances have been the advent of high speed digital video cameras and the use of Digital Image Correlation techniques to measure deformations and strains at high rates. These advances have led to significantly more accurate measurements of material and structural response under high rate loading, which has also led to advances in computational modeling techniques for Impact Dynamics. In this address we will review the past, present and what the future may hold for experimental methods in the field of Structural Impact Dynamics.

Structural Impact Dynamics↗

Paint and Shoot

Through an initial SBIR contract with Langley Research Center, Stress Photonics, Inc. was able to successfully market their thermal strain measurement device, known as the Delta Therm 1000. The company was able to further its research on structural integrity analysis by signing another contract with Langley, this time a STTR contract, to develop its polariscope stress technology. Their commercial polariscope, the GFP 1000, involves a single rotating optical element and a digital camera for full-field image acquisition. The digital camera allows automated data to be acquired quickly and efficiently. Software analysis presents the data in an easy to interpret image format, depicting the magnitude of the shear strains and the directions of the principal strains.

Source record↗

Long-term super-resolution inner mitochondrial membrane imaging with a lipid probe

The inner mitochondrial membrane (IMM) generates power to drive cell function, and its dynamics control mitochondrial health and cellular homeostasis. Here, we describe the cell-permeant, lipid-like small molecule MAO-N 3 and use it to assemble high-density environmentally sensitive (HIDE) probes that selectively label and image the IMM in live cells and multiple cell states. MAO-N 3 pairs with strain-promoted azide–alkyne click chemistry-reactive fluorophores to support HIDE imaging using confocal, structured illumination, single-molecule localization and stimulated emission depletion microscopy, all with significantly improved resistance to photobleaching. These probes generate images with excellent spatial and temporal resolution, require no genetic manipulations, are non-toxic in model cell lines and primary cardiomyocytes (even under conditions that amplify the effects of mitochondrial toxins) and can visualize mitochondrial dynamics for 12.5 h. This probe will enable comprehensive studies of IMM dynamics with high temporal and spatial resolution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Synchrotron CT imaging of lattice structures with engineered defects

Understanding mechanical failure, crack propagation, and compressive behavior at the micrometer scale is essential for tailoring material properties for structural performance in cellular materials. Typically, modeling of traditional polymer foam materials is clouded by the lack of control in material morphology and its inherent stochastic structure. Additive manufacturing with sub-micrometer resolution provides a direct path for experimenters to specifically tailor structures needed by modelers to explicitly probe mechanical performance. Using laboratory-based 3D X-ray computed tomographic imaging (CT), the examination of deformation and damage provides a critical path to understand how these soft materials behave. Additionally, synchrotron CT yields realistic information at higher strain rates to directly validate the robustness of our finite element modeling. For this study, nanolithographic printing was employed to generate a series of engineered lattices with increasing levels of defects through the random removal of ligaments. These structures were mechanically tested and imaged with laboratory-based microCT. Additionally, synchrotron experiments were conducted in which the structures were imaged in 3D at 14 Hz during compression at a 0.4 s –1 strain rate. These 3D images show the changes in the structure as the ligaments bend, buckle and fracture in real time. This technique provides a robust framework for developing our methodologies and future exploration of engineered structures.

36 MATERIALS SCIENCE↗

In-situ strain behavior and BISON simulations of Zircaloy cladding subjected to temperature cycling separate-effects tests in a steam environment

Understanding fuel system performance during anticipated transients without scram (ATWSs) in boiling water reactors (BWRs) is necessary for refining current and future safety limits. High-fidelity material models and simulations are fundamental to rigorous assessment of zirconium-based cladding performance. However, experimental thermomechanical data during simulated ATWSs to validate these modes are limited. To provide relevant in-situ data, Zircaloy-4 cladding was subjected to cyclic heating in a steam environment to simulate an out-of-pile BWR ATWS. Digital image correlation was used to capture the cladding strain behavior in-situ for comparison against simulations using the BISON finite element code. Conventional high-temperature models were compared using multiple schemes to gain a better understanding of the applicability of three BISON models to BWR ATWS: (1) the default combination of creep models in BISON, (2) the high-temperature Erbacher model alone, and (3) the low-temperature Limback-Andersson model alone. The cases run with the Limback-Andersson model alone produced the lowest root mean square error (RMSE). The lowest RMSE for the Limback-Andersson model alone was 0.659%, and the highest RMSE reported was 4.22%. A data gap within the model in the temperature regime of interest was also identified, and to account for this gap, the current model in BISON is linearly interpolated between two separate datasets. In conclusion, this evaluation highlights the need to either develop a new model or to improve the existing model to capture transient creep effects resulting from a cyclic temperature transient.

Anticipated transient without SCRAM↗

In Situ Strain Evolution on Pt Nanoparticles during Hydrogen Peroxide Decomposition

Fundamental understanding of structural changes during catalytic reactions is crucial to understanding the underlying mechanisms and optimizing efficiencies. Surface energy and related catalytic mechanisms are widely studied. However, the catalyst lattice deformation induced by catalytic processes is not well understood. Here, we study the strain in an individual platinum (Pt) nanoparticle (NP) using Bragg coherent diffraction imaging under in situ oxidation and reduction reactions. When Pt NPs are exposed to H 2 O 2 , a typical oxidizer and an intermediate during the oxygen reduction reaction process, alternating overall strain distribution near the surface and inside the NP is observed at the (111) Bragg reflection. In contrast, relatively insignificant changes appear in the (200) reflection. Density functional theory calculations are employed to rationalize the anisotropic lattice strain in terms of induced stress by H 2 O 2 adsorption and decomposition on the Pt NP surface. Our study provides deeper insight into the activity-structure relationship in this system.

3D imaging↗

Digital Image Correlation Techniques Applied to Large Scale Rocket Engine Testing

Rocket engine hot-fire ground testing is necessary to understand component performance, reliability and engine system interactions during development. The J-2X upper stage engine completed a series of developmental hot-fire tests that derived performance of the engine and components, validated analytical models and provided the necessary data to identify where design changes, process improvements and technology development were needed. The J-2X development engines were heavily instrumented to provide the data necessary to support these activities which enabled the team to investigate any anomalies experienced during the test program. This paper describes the development of an optical digital image correlation technique to augment the data provided by traditional strain gauges which are prone to debonding at elevated temperatures and limited to localized measurements. The feasibility of this optical measurement system was demonstrated during full scale hot-fire testing of J-2X, during which a digital image correlation system, incorporating a pair of high speed cameras to measure three-dimensional, real-time displacements and strains was installed and operated under the extreme environments present on the test stand. The camera and facility setup, pre-test calibrations, data collection, hot-fire test data collection and post-test analysis and results are presented in this paper.

Gradl, Paul R.↗

Sand Shear Band Thickness Measurements by Digital Imaging Techniques

Digital imaging analysis was used to study localized deformations in granular materials tested under plane strain condition. Two independent techniques were applied and compared. In the first, the digitized optical images of a grid printed on the latex membrane were used to measure the shear band orientation angle and thickness, and were found to be 54.5' and 3.01 mm respectively. The second technique involved introducing an ultra-low viscosity resin into the specimen in preparation for thin- sectioning and microscopic study of the internal fabric. A total of 24 microscopic images obtained from four thin sections were analyzed and void ratio variation was measured. The shear band thickness measurements from images located along the shear band axis (at two locations) were equal to 3.19 mm and 3.29 mm which are very close to the average value obtained from surface analysis. The study was then extended to investigate the effects of sand grain-size and properties, specimen density, and confining pressure on shear band thickness. It was found that the normalized shear band thickness decreases as grain-size and confining pressure increase and as density decreases. Finally, shear band thickness is highly influenced by the specimen dilatancy.

Alshibli, Khalid A.↗