As renewable energy is rapidly integrated into the grid, the challenge has become storing intermittent renewable electricity. Technologies including flow batteries and CO 2 conversion to dense energy carriers are promising storage options for renewable electricity. To achieve this technological advancement, the development of next generation electrolyte materials that can increase the energy density of flow batteries and combine CO 2 capture and conversion is desired. Liquidlike nanoparticle organic hybrid materials (NOHMs) composed of an inorganic core with a tethered polymeric canopy (e.g., polyetheramine (HPE)) have a capability to bind chemical species of interest including CO 2 and redox-active species. In this study, the unique response of NOHM-I-HPE-based electrolytes to salt addition was investigated, including the effects on solution viscosity and structural configurations of the polymeric canopy, impacting transport behaviors. The addition of 0.1 M NaCl drastically lowered the viscosity of NOHM-based electrolytes by up to 90%, reduced the hydrodynamic diameter of NOHM-I-HPE, and increased its self-diffusion coefficient, while the ionic strength did not alter the behaviors of untethered HPE. This study is the first to fundamentally discern the changes in polymer configurations of NOHMs induced by salt addition and provides a comprehensive understanding of the effect of ionic stimulus on their bulk transport properties and local dynamics. These insights could be ultimately employed to tailor transport properties for a range of electrochemical applications.
Abstract not provided.
Explore the source record for details and available documents.
Idaho National Laboratory (INL), supported by the Department of Energy Office of Nuclear Energy (DOE-NE) through the Nuclear Science User Facilities, provides access to supercomputer systems and data storage along with support staff for system management, software installation, cybersecurity, and user support to the broader DOE-NE user community. A key component of this is providing long-term or perpetual data storage as part of efforts to improve reproducibility in modeling and simulation in addition to supporting simulations with regulatory compliance requirements. This milestone details the deployment of a new type of storage option for users requiring tamper resistant perpetual storage of data and the associated support for data control and release via the data storage web interface. The perpetual data storage system is integrated within the Open OnDemand framework deployed at INL and is called the ?WORM? in recognition of its write-once read-many characteristics.
The Energy & Environmental Research Center (EERC), in partnership with Minnkota Power Cooperative Inc. (Minnkota), SLB, and Computer Modelling Group Ltd. (CMG), supported wide-scale deployment of carbon capture and storage (CCS) as part of the U.S. Department of Energy (DOE) National Energy Technology Laboratory Carbon Storage Assurance Facility Enterprise (CarbonSAFE) Initiative Phase III. This phase included the acquisition, analysis, and development of information to fully characterize two storage complexes to demonstrate viable storage resources for commercial volumes of CO2 (defined by DOE as a minimum of 50 million tonnes [MMt] of CO2 within a 30-year period) (National Energy Technology Laboratory, 2024). Phase III also involved the preparation, submission, and approval of North Dakota underground injection control (UIC) Class VI storage facility permits (SFPs)—required precursors to applications for Class VI injection well permits. The presumed viability of commercial-scale CCS, situated adjacent to Minnkota’s Milton R. Young Station (MRYS), is validated by Minnkota’s continued pursuit of Project Tundra—an initiative to build the world’s largest lignite-based CCS project in central North Dakota (www.projecttundrand.com). Project Tundra comprises two scopes of work, Tundra Capture (installation of postcombustion CO2 capture at MRYS) and Tundra SGS (secure geologic storage). The efforts of North Dakota CarbonSAFE Phase III, Site Characterization and Permitting, supported Tundra SGS. Extensive site-specific characterization activities included a successful multimeasurement geophysical approach and drilling a stratigraphic test well (J-ROC 1, subsequently renamed Liberty-1) adjacent to MRYS. Core collection and analyses, downhole testing and fluid sampling, and geophysical logging were performed on J-ROC 1 and on a nearby stratigraphic test well (known as J-LOC 1), which was drilled, cored, and tested under a complementary project funded by the North Dakota Lignite Research Program. The injection tests performed on J-LOC 1 positively impacted the CarbonSAFE project, resulting in fewer proposed injection wells and significant construction, operations, and monitoring cost savings. The characterization data collected and analyses performed were integrated into geologic models, and successive numerical simulations were run to determine CO2 plume extent and subsurface pressure buildup associated with the planned CO2 injection rate of nearly 4 MMt per year. The latter doubles the CarbonSAFE Initiative goal with an estimated 100 MMt of CO2 stored in 20 years. Application of the U.S. Environmental Protection Agency’s (EPA’s) method for estimating the Class VI Rule area of review (AOR) to the overpressurized Broom Creek Formation inspired an alternative method of calculation, called risk-based AOR delineation. This peer-reviewed method was applied for the first time during the storage facility-permitting process. The two SFP applications submitted in 2021 successfully resulted in North Dakota Industrial Commission (NDIC) orders in 2022 authorizing the creation of the storage facility areas and amalgamation of pore space as well as establishing financial responsibility requirements. After approval of the SFPs, Minnkota filed in 2022 applications for permits to reenter the J-ROC 1 well and to drill two new wells—all with the intended purpose to become Class VI injection wells. To establish eligibility under the Internal Revenue Code for Section 45Q tax incentives, a monitoring, reporting, and verification (MRV) plan was prepared and submitted by Minnkota to EPA in 2022, resulting in the first such plan approved in North Dakota. Also in 2022, under the National Environmental Policy Act (NEPA), Minnkota prepared and submitted an environmental information volume (EIV) describing the proposed CCS project and associated potential environmental impacts. Based on the EIV, DOE determined that the proposed construction project required an environmental assessment, and Minnkota submitted the first draft in 2023 and a revised draft in 2024. Both submissions were followed by a public comment period. Subsequently, DOE issued a finding of no significant impact (FONSI) on September 13, 2024. A successful outreach program, strongly based in the production, presentation, and dissemination of informational material, fostered an environment to aid stakeholders in making informed decisions regarding the planned project. Opportunities for public input were provided at various steps along the way, including at county planning and zoning meetings, before and during the SFP administrative hearing, and during environmental assessment public comment periods. In addition, land/pore space owners and mineral owners had various points of contact, including granting access rights, securing pore space leasing, and mineral owner notifications. Based upon the successful storage facility permitting issued by NDIC, approval of the MRV plan by EPA, and receipt of a FONSI under the NEPA, Minnkota is continuing its pursuit of Project Tundra. In December 2023, the Office of Clean Energy Demonstrations under its Carbon Capture Demonstrations Projects Program announced funding for the capture system (Office of Clean Energy Demonstrations, 2023) and a proposal for CarbonSAFE Phase IV: Construction funding was submitted in March 2024 for the storage project. A go/no-go decision to proceed with construction and operations in the Broom Creek Formation is anticipated in 2024. References National Energy Technology Laboratory, CarbonSafe Initiative, https://netl.doe.gov/carbon-management/carbon-storage/carbonsafe (accessed August 2024). Office of Clean Energy Demonstrations, 2023, OCED selects three projects in CA, ND, and TX to reduce harmful carbon pollution, create new economic opportunities, and advance carbon reducing technologies, December, www.energy.gov/oced/articles/oced-selects-three-projects-ca-nd-and-tx-reduce-harmful-carbon-pollution-create-new (accessed August 2024).
The novel tri-port current-source medium-voltage string inverter (TCS-MVSI) is a promising candidate for large-scale PV-plus-storage (PVS) farms owing to its galvanic isolation, easy storage integration, soft-switching capability across entire load range, controlled low dv/dt and EMI, benign fault tolerance, etc. Due to its low inertia feature, traditional PI-based control cannot manage large transients effectively. Instead, a model-based predictive control (MPC) is proposed to achieve robust and stable operation. As is well known, the control performance of MPC is compromised by the sampling and computational delay during implementation significantly, if not well addressed. This paper analyzed and quantified these delays and then proposes feed-forward compensation (FFC) for the MPC method to compensate the delays and the large parameter variations due to the low-inertia nature. In addition, this method also compensates for the high dc-link ripple within each switching cycle, a unique issue for low-inertia converters. Here, the proposed method requires low computational effort, allowing it to be extended for multiple ports. The effectiveness of the proposed method has been validated in experiments. In 10 kW test, the proposed method decreases the average dc-link current by 17%, leading to ~20% conduction losses and ~0.5% increase in converter efficiency. In addition, the peak dc-link current also decreases by 15%, resulting in reduced transformer size. As a result, an increased power density can be achieved with the proposed method. Similar improvements have been observed across the power range from 2 kW to 10 kW.
Abstract Composite materials comprising polymers and inorganic nanoparticles (NPs) are promising for energy storage applications, though challenges in controlling NP dispersion often result in performance bottlenecks. Realizing nanocomposites with controlled NP locations and distributions within polymer microdomains is highly desirable for improving energy storage capabilities but is a persistent challenge, impeding the in‐depth understanding of the structure–performance relationship. In this study, a facile entropy‐driven self‐assembly approach is employed to fabricate block copolymer‐based supramolecular nanocomposite films with highly ordered lamellar structures, which are then used in electrostatic film capacitors. The oriented interfacial barriers and well‐distributed inorganic NPs within the self‐assembled multilaminate nanocomposites effectively suppress leakage current and mitigate the risk of breakdown, showing superior dielectric strength compared to their disordered counterparts. Consequently, the lamellar nanocomposite films with optimized composition exhibit high energy efficiency (>90% at 650 MV m −1 ), along with remarkable energy density and power density. Moreover, finite element simulations and statistical modeling have provided theoretical insights into the impact of the lamellar structure on electrical conduction, electric field distribution, and electrical tree propagation. This work marks a significant advancement in the design of organic–inorganic hybrids for energy storage, establishing a well‐defined correlation between microstructure and performance.
Conference presentation at Underground Injection Control Annual Meeting of the Groundwater Protection Council, San Antonio, Texas, February 18, 2020. An overview of the Plains CO 2 Reduction (PCOR) Partnership Initiative and carbon capture, utilization, and storage (CCUS) activity in the region. Includes permitting process for CCUS deployment in North Dakota.
The stability of multiparalleled grid-tied inverters remains a challenging issue especially during low-voltage ride-through (LVRT) in the presence of grid impedance. SiC device-based grid-tied inverters can achieve advantages such as higher efficiency, reduced size of interface filters, and fast dynamics; however, they can exacerbate this stability issue particularly when LVRT occurs along with high inrush current due to their low inertia characteristics. In this article, a direct deadbeat control method without any PI control loop is proposed for multiparallel grid-tied SiC inverters. The proposed control achieves instantaneous current regulations within switching cycles. In addition, it mitigates high inrush currents and maintains stability during LVRT transients without requiring mode transitions between normal and LVRT operation modes, thereby achieving an ultrafast response and seamless operation through this unified control method. The Lyapunov method is applied to analyze the multiparallel inverter stability in the presence of grid impedance with proposed deadbeat control method. The inverter V-I trajectories during LVRT transients are derived to illustrate the ultrafast and stable feature of proposed control. Finally, the experimental results of two grid-tied SiC inverters operating at LVRT transients are provided to verify the advantages of the proposed control method.
A general problem when designing functional nanomaterials for energy storage is the lack of control over the stability and reactivity of metastable phases. Using the high-capacity hydrogen storage candidate LiAlH4 as an exemplar, we demonstrate an alternative approach to the thermodynamic stabilization of metastable metal hydrides by coordination to nitrogen binding sites within the nanopores of N-doped CMK-3 carbon (NCMK-3). The resulting LiAlH 4 @NCMK-3 material releases H 2 at temperatures as low as 126 °C with full decomposition below 240 °C, bypassing the usual Li 3 AlH 6 intermediate observed in bulk. Moreover, >80% of LiAlH 4 can be regenerated under 100 MPa H 2 , a feat previously thought to be impossible. Nitrogen sites are critical to these improvements, as no reversibility is observed with undoped CMK-3. Density functional theory predicts a drastically reduced Al–H bond dissociation energy and supports the observed change in the reaction pathway. Finally, the calculations also provide a rationale for the solid-state reversibility, which derives from the combined effects of nanoconfinement, Li adatom formation, and charge redistribution between the metal hydride and the host.
For the U.S. Department of Energy’s (DOE) 2016 Small Business Voucher for Marine and Hydrokinetic (MHK) System, Second Round 2016, ORPC intends to work with the National Renewable Energy Laboratory (NREL) to perform dynamometer testing of the MHK generator systems and its associated controls and inverters. ORPC will provide the generator, variable frequency drives (VFD), controls, and inverter for this testing. NREL will utilize the NREL Energy Systems Integration Facility (ESIF) and dynamometer facilities at the National Wind Technology Center (NWTC) for this work. Modification 6: Additionally, NREL will conduct a feasibility study for implementing passive DC rectification at the turbine.
Project overcomes frequency stability and system control issues when operating distribution microgrids in a low inertia, high PV penetration environment without fossil fuel generators. The team implemented a grid-forming inverter and advanced control features at SDG&E's Borrego Springs Microgrid to demonstrate islanding and blackstart using renewable resources. Simulation and emulation in advance of deployment de-risks field operations.
Pumped Thermal Energy Storage (PTES) uses electricity to power a heat pump; transferring heat from a cold space to a hot space forms a hot and a cold thermal reservoir, thereby storing energy. To discharge, the temperature difference between the two stores is used to drive a heat engine which generates electricity. In this chapter, PTES systems which store energy in liquids will be described. The chapter will concentrate on Joule-Brayton power cycles with molten salt storage. Part-load operation of Joule-Brayton PTES with liquid storage can be managed with "inventory control," and it is demonstrated that this control method leads to relatively good performance over a range of operating points.
Today, consumer battery installations are isolated, physical devices. Virtual power plants (VPPs) allow consumer devices to aggregate for grid services, but they are are vertically integrated, vendor controlled systems (e.g., Tesla’s VPP). Consumer batteries are therefore unable to participate in energy markets or other grid services outside what their vendor provides. We describe a software system that provides software control of multiple, networked battery energy storage systems in the electric grid. The system introduces two new ideas that enable flexible and dependable management of energy storage. The first is a virtual battery, which can either partition a battery or aggregate multiple batteries. The second is a reservation-based API which allows asynchronous control of batteries to meet contractual guarantees in a safe and dependable manner. Virtual batteries and a reservation-based API address the unique challenges of achieving high and efficient utilization of energy storage systems, including heterogeneity of battery systems such as varying C-rates, participation in energy markets, utility bill management systems, community resource sharing, and reliability. Using a testbed comprised of sonnen Inc. storage units installed in several homes and a lab, we demonstrate that virtualized batteries can seamlessly replace physical batteries, flexibly manage energy storage resources, isolate multiple clients using a shared battery, and create new energy storage applications.
Microgrids continue to proliferate, particularly those that rely on inverter-based resources as the microgrid's voltage and frequency leader. Hardware-in-the-loop simulations can de-risk microgrid deployments, and therefore we need power-hardware-in-the-loop (PHIL) interfaces for grid-forming (GFM) inverters to enable simulations of seamless transitions between islanded and grid-connected operation. Such interfaces are particularly challenging when the inverters need to switch modes, i.e., between grid-following (GFL) and GFM as the microgrid transitions between grid-connected and islanded operation. This presentation shows the use of PHIL interfaces for such microgrids and the preliminary experimental results.
The aging U.S. building stock requires various retrofit measures to enhance their energy efficiency. Here, this study explores the integration of thermal energy storage and advanced building controls as viable retrofit solutions for load flexibility and peak demand response while maintaining the occupants' comfort. A detailed assessment is conducted on the energy use of an administrative building in Sumner County, Kansas, focusing on the implementation of phase change materials (PCMs) in the ceiling of occupied zones. First, a time-resolved, whole-building energy model is developed in EnergyPlus, incorporating complex thermal behaviors such as air exchange between the plenum space and occupied zones, envelope leakage, and operational schedules. The model is then validated using experimental field test data, and subsequently a parametric assessment of key PCM properties and application strategies is performed to evaluate cooling electricity demand benefits. The parametric study shows that the optimal retrofit strategy, comprising a PCM with 23°C peak melting temperature, 0.125 in. (3.17 mm) thickness, and 150 kJ/kg latent heat, combined with active controls that include 8 h of precooling, forced convection under the ceiling, and a 2°C thermostat setback during peak hours, can result in a maximum load shift during the peak period of 99.6 % and the total electricity savings during the peak period of 98.9 % for the optimum case and thus provide significant cost savings under time-of-use pricing scenarios.