Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “steam flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Counter-Current Flow Limitation Studies in Complex Geometries Utilizing Interface Capturing Simulations Coupled with PID Flow Rate Controller

In nuclear thermal-hydraulic studies, counter-current flow limitation (CCFL) typically refers to steam rising at a fast rate such that it prevents coolant from draining down within a confined channel. CCFL is a crucial issue in nuclear reactor safety analysis. This study investigates CCFL in debris bed channels using high-resolution interface-capturing simulations. A novel proportional-integral-derivative flow rate controller is developed to efficiently achieve the CCFL conditions. Verification studies confirm that CCFL occurs under the same conditions with or without the controller, demonstrating that PID control ensures accurate prediction. Three debris bed channel geometries were examined: a cylindrical channel, a channel with small obstacles, and a channel with large obstacles. Results show that obstacles significantly impact flow behavior, interfacial shear, wall shear, and pressure gradients required for CCFL. Furthermore, the comparison with experimental data confirmed that simulations incorporating geometric complexities align more closely with experimental CCFL conditions. A pressure gradient correlation was also developed for CCFL prediction.

Counter-current flow limitation↗

Modeling of crystallization fouling on a horizontal-tube falling-film evaporator for thermal desalination

Scale formation within horizontal-tube falling-film evaporators is an important issue for thermal desalination, because of the deterioration of heat transfer performance and added maintenance costs. Predicting the fouling process is crucial for desalination plant design, operation, and maintenance. In this paper, a model is developed to predict the crystallization fouling process during seawater falling-film flow over a horizontal tube bundle. The scaling is estimated based on deposition theory, with couple heat transfer including the in-tube steam condensation, conduction through the tube wall and the scale layer, and falling-film evaporation. The spatial and temporal variations of temperature, heat transfer coefficient, and scale thickness are predicted, and the effects of variations in process parameters of steam, feed seawater, and tube properties on the scale thickness, evaporation rate, and heat transfer coefficient for falling-film evaporation are analyzed. Comparisons to existing experimental data show the scaling layer thickness falls in the general range of reported measurements, with a slight overestimation due to neglecting the delay of scaling onset under real conditions. The scale layer thickness increases dramatically as the in-tube steam pressure is increased or the seawater flow rate is decreased. In general, the scaling layer becomes thicker on the lower tubes in the tube bundle, due to the heat and mass transfer of the falling film. The effect of tube material on scaling appears mainly dependent on thermal conductivity; thus, using polymer rather than a stainless steel tube decreases scaling and evaporation rate 96% and 88%, respectively. Finally, this work has potential to guide thermal desalination plant design, material selection, and operating parameter optimization.

42 ENGINEERING↗

Steam Generator Model Design Parameter Sensitivity Study Using Advanced Optimization Tools

This study focuses on design parameter sensitivity studies pertaining to a steam generator (SG) model, using both Python and machine-learning tools. The SG model is a mathematical representation (including fluid flow and heat transfer equations/models/correlations) of a steam-generating unit in a pressurized water reactor (PWR)-type small modular reactor (SMR) system. Design studies involve changing the model’s input design parameters (e.g., temperature, pressure, mass flow rate) to observe the resulting effects on the output of the system (e.g., heat transfer coefficient [HTC], Nusselt number, heat transfer performance). Sensitivity studies analyze the degree to which system output and/or desired parameters (e.g., HTC or heat transfer performance) are sensitive to changes in input parameters. By using machine-learning tools such as the Risk Analysis Virtual Environment (RAVEN) developed at Idaho National Laboratory (INL), detailed design parametric sensitivity studies and model optimization were performed. Six input parameters—namely, the pressure, temperature, and mass flow rate for the inlet of the primary-side (hot fluid) and secondary-side (cold fluid) of the SG—were randomly perturbed via RAVEN’s Monte Carlo Sampler module, using uniform distributions (±1% relative changes). The analysis results give valuable insights into SG system performance and optimization, and provide justification for researching optimized sensor placement to effectively monitor and obtain experimental data.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Steam Generator Model Design Parameter Sensitivity Study Using Advanced Optimization Tools

This study focuses on design parameter sensitivity studies pertaining to a steam generator (SG) model, using both Python and machine-learning tools. The SG model is a mathematical representation (including fluid flow and heat transfer equations/models/correlations) of a steam-generating unit in a pressurized water reactor (PWR)-type small modular reactor (SMR) system. Design studies involve changing the model’s input design parameters (e.g., temperature, pressure, mass flow rate) to observe the resulting effects on the output of the system (e.g., heat transfer coefficient [HTC], Nusselt number, heat transfer performance). Sensitivity studies analyze the degree to which system output and/or desired parameters (e.g., HTC or heat transfer performance) are sensitive to changes in input parameters. By using machine-learning tools such as the Risk Analysis Virtual Environment (RAVEN) developed at Idaho National Laboratory (INL), detailed design parametric sensitivity studies and model optimization were performed. Six input parameters—namely, the pressure, temperature, and mass flow rate for the inlet of the primary-side (hot fluid) and secondary-side (cold fluid) of the SG—were randomly perturbed via RAVEN’s Monte Carlo Sampler module, using uniform distributions (±1% relative changes). The analysis results give valuable insights into SG system performance and optimization, and provide justification for researching optimized sensor placement to effectively monitor and obtain experimental data.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Steam Condensation Scaled Experiment in the Presence of Non-condensable Gas for Reactor Containment Passive Safety Analysis

This study presents scaled experiments using steam condensation with non-condensable gas (NCG)—helium, simulating hydrogen—as these experiments are pivotal for water-cooled reactor passive containment cooling system (PCCS) design and analysis. Research into PCCSs for small modular reactors (SMRs) is especially important in light of SMR system design; however, studies in the literature reflect limitations due to test geometry and operational condition variations, without considering SMR prototypic design. To address these challenges, a scaled test facility was developed to accurately replicate SMR PCCSs. This facility includes vertical down-flow condensing test sections with 1-, 2-, and 4-in.-diameter condensing tubes, accompanied by annular water cooling. Experiments were conducted using both superheated and saturated steam, with steam mass flow rates varying from 55 to 66 kg/hr., in the presence of helium as the NCG mass flow rate ranges from 1.8 to 22 kg/hr. Test data were collected on (a) the axial temperatures of the annular cooling water; (b) the outer wall temperature of the condensers; and (c) the mass flow rate, temperature, and pressure at the test section inlets and outlets. These primary test data were used in conjunction with a standard data reduction methodology to estimate essential thermal parameters such as heat fluxes, heat transfer coefficients, and condensation rates. The effects of NCGs on steam condensation within the geometry of the scaled test sections were then presented in regard to various testing conditions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Presentation: Steam Condensation Scaled Experiment in the Presence of Non-condensable Gas for Reactor Containment Passive Safety Analysis

This study presents scaled experiments using steam condensation with non-condensable gas (NCG)—helium, simulating hydrogen—as these experiments are pivotal for water-cooled reactor passive containment cooling system (PCCS) design and analysis. Research into PCCSs for small modular reactors (SMRs) is especially important in light of SMR system design; however, studies in the literature reflect limitations due to test geometry and operational condition variations, without considering SMR prototypic design. To address these challenges, a scaled test facility was developed to accurately replicate SMR PCCSs. This facility includes vertical down-flow condensing test sections with 1-, 2-, and 4-in.-diameter condensing tubes, accompanied by annular water cooling. Experiments were conducted using both superheated and saturated steam, with steam mass flow rates varying from 55 to 66 kg/hr., in the presence of helium as the NCG mass flow rate ranges from 1.8 to 22 kg/hr. Test data were collected on (a) the axial temperatures of the annular cooling water; (b) the outer wall temperature of the condensers; and (c) the mass flow rate, temperature, and pressure at the test section inlets and outlets. These primary test data were used in conjunction with a standard data reduction methodology to estimate essential thermal parameters such as heat fluxes, heat transfer coefficients, and condensation rates. The effects of NCGs on steam condensation within the geometry of the scaled test sections were then presented in regard to various testing conditions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Application of the new IAPWS Guideline on the fast and accurate calculation of steam and water properties with the Spline-Based Table Look-Up Method (SBTL) in RELAP-7

The numerical simulation of thermalhydraulic processes in nuclear power plants requires very accurate and extremely fast algorithms for calculating the thermophysical properties of water and steam. In order to provide such algorithms, the International Association for the Properties of Water and Steam (IAPWS) has adopted the new “IAPWS Guideline on the Fast Calculation of Steam and Water Properties with the Spline-Based Table Look-Up Method (SBTL)”. In this article, the SBTL method is applied to property functions of specific volume and specific internal energy (v,e) based on the scientific formulation IAPWS-95 and the latest IAPWS formulations for transport properties. From the newly generated SBTL functions, thermodynamic and transport properties as well as their derivatives and inverse functions are calculable in the fluid range of state for pressures up to 100 MPa and for temperatures up to 1273 K, including the metastable liquid and the metastable vapor regions. The SBTL functions reproduce the underlying formulations with an accuracy of 10–100 ppm and significantly reduced computing times. The SBTL method has been implemented into the nuclear reactor system safety analysis code RELAP-7 [2] to consider the real fluid behavior of water and steam in a novel 7-equation two-phase flow model.

42 ENGINEERING↗

Effects of wall thickness on the flow instability of supercritical pressure water in a tube - 18568

The subcritical steam generators in the current high-temperature-reactor pebble-bed module, HTR-PM, in China can be replaced by supercritical steam generators to better coordinate the reactors and the supercritical steam turbines to improve thermal efficiencies with no phase change at supercritical pressures. This study numerically studied the heat transfer and flow instability of supercritical pressure water in a vertical tube with zero- and finite-thickness walls. The effect of the wall thickness on the heat transfer of supercritical pressure water at steady state was negligible. In the transient calculations, the fluid flow rate oscillated intensely beyond a certain heat flux with zero-thickness wall, while the flows in the tube with the finite-thickness walls acted totally different. The wall properties including the density and specific heat were varied to analyze why the oscillations were suppressed when the finite-thickness wall was considered in the calculation. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Three-Dimensional Electrical Resistivity Tomography of the Solfatara Crater (Italy): Implication for the Multiphase Flow Structure of the Shallow Hydrothermal System: Resistivity Model of Solfatara Crater

The Solfatara volcano is the main degassing area of the Campi Flegrei caldera, characterized by 30 of unrest. Assessing and understanding such renewal activity is a challenging task because hydrothermal interactions with magmatic gases remain poorly understood. In this study, we decipher the complex structure of the shallow Solfatara hydrothermal system by performing the first 3-D, high-resolution, Electrical Resistivity Tomography (ERT) of the volcano. The 3-D resistivity model was obtained from the inversion of 43,432 resistance measurements performed on an area of 0.68 km 2 . The proposed interpretation of the multiphase hydrothermal structures is based on the resistivity model, a high-resolution infrared surface temperature image, and 1,136 soil CO 2 flux measurements. In addition, we realized 27 soil Cation Exchange Capacity (CEC) and pH measurements demonstrating a negligible contribution of surface conductivity to the shallow bulk electrical conductivity. Hence, we demonstrate that the resistivity changes are mainly controlled by fluid content and temperature. The high-resolution tomograms identify for the first time the structure of the gas-dominated reservoir at 50 m depth that feeds the Bocca Grande fumarole through a ~10-m-thick channel. In addition, the resistivity model reveals a channel-like conductive structure where the liquid produced by steam condensation around the main fumaroles flows down to the Fangaia area within a buried fault. The model delineates the emplacement of the main geological structures: Mt Olibano, Solfatara crypto-dome, and tephra deposits. It also reveals the anatomy of the hydrothermal system, especially two liquid-dominated plumes, the Fangaia mud pool and the Pisciarelli fumarole, respectively.

58 GEOSCIENCES↗

Plant-wide simulation model for transient studies on the XE-100 - 18464

This paper gives an overview of the plant-wide simulation model that is used by X-energy LLC for developing their plant design and control philosophy, as well as assessing plant upset conditions. The simulation model was created in Flownex{sup R} thermal-fluid system simulation software, which solves mass, momentum and energy equations for compressible, incompressible and homogeneous two-phase flow. The plant model encompasses all major components, from reactor to condenser, including main control loop elements. The paper pays particular attention to the validation of the two-phase flow framework used for the secondary steam cycle. Two steady-state validation cases are done using operational data from the THTR. Validation of transient operation is done by simulating density wave oscillations, a type of system-level boiling phenomenon. This is regarded as a thorough test of transient capability because of the challenges this phenomenon poses to several aspects of the calculation and to the consistency of the code as a whole. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

EARLY HAWAIIANS AND VOLCANIC HEAT

This research serves as the first-known compilation of accounts of early Hawaiians using volcanic heat. Western explorers in the 1800s wrote about native Hawaiians near $K\bar{i}lauea$ Volcano using volcanic heat for cooking and bathing. They cooked their food wrapped in leaves underground or above a steam crack at Sulphur Banks, $K\bar{i}lauea$ Iki, and the $N\bar{a}pau$ Crater Trail. Early Hawaiians bathed in the warm waters of Waiwelawela for health. To confirm the presence of volcanic heat, this study used geothermal resource maps by the Hawai‘i Play Fairway project. According to a probability map for volcanic heat, the areas where Hawaiians used volcanic heat have a probability of volcanic heat of 0.8 to 1.0. On a map with temperatures of water wells, water wells close to where Hawaiians used volcanic heat have elevated temperatures. Historically, the areas where Hawaiians used volcanic heat experienced volcanic steam release, volcanic eruptions, and lava flows.

Geology↗

DTK C/Fortran Interface Development for NEAMS FSI Simulations

This report documents the development of DataTransferKit (DTK) C and Fortran interfaces for fluid-structure-interaction (FSI) simulations in NEAMS. In these simulations, the codes Nek5000 and Diablo are being coupled within the SHARP framework to study flow-induced vibration (FIV) in reactor steam generators. We will review the current Nek5000/Diablo coupling algorithm in SHARP and the current state of the solution transfer scheme used in this implementation. We will then present existing DTK algorithms which may be used instead to provide an improvement in both flexibility and scalability of the current SHARP implementation. We will show how these can be used within the current FSI scheme using a new set of interfaces to the algorithms developed by this work. These new interfaces currently expose the mesh-free solution transfer algorithms in DTK, a C++ library, and are written in C and Fortran to enable coupling of both Nek5000 and Diablo in their native Fortran language. They have been compiled and tested on Cooley, the test-bed machine for Mira at ALCF.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Combined Heat and Power Technology Fact Sheet Series: District Energy

This fact sheet provides an overview of district energy systems, which are characterized by one or more central plants producing hot water, steam, and/or chilled water, which then flows through a network of insulated pipes to provide hot water, space heating, and/or air conditioning for nearby buildings. District energy systems serve a variety of end-use markets, including downtowns (central business districts), college and university campuses, hospitals and healthcare facilities, airports, military bases, and industrial complexes. By combining loads for multiple buildings, district energy systems create economies of scale that help reduce energy costs and enable the use of high-efficiency technologies such as combined heat and power (CHP).

Combined Heat and Power, CHP, District Energy, Tec↗

Compressibility Effects in Aeronautical Engineering

Compressible-flow research, while a relatively new field in aeronautics, is very old, dating back almost to the development of the first firearm. Over the last hundred years, researches have been conducted in the ballistics field, but these results have been of practically no use in aeronautical engineering because the phenomena that have been studied have been the more or less steady supersonic condition of flow. Some work that has been done in connection with steam turbines, particularly nozzle studies, has been of value, In general, however, understanding of compressible-flow phenomena has been very incomplete and permitted no real basis for the solution of aeronautical engineering problems in which.the flow is likely to be unsteady because regions of both subsonic and supersonic speeds may occur. In the early phases of the development of the airplane, speeds were so low that the effects of compressibility could be justifiably ignored. During the last war and immediately after, however, propellers exhibited losses in efficiency as the tip speeds approached the speed of sound, and the first experiments of an aeronautical nature were therefore conducted with propellers. Results of these experiments indicated serious losses of efficiency, but aeronautical engineers were not seriously concerned at the time became it was generally possible. to design propellers with quite low tip. speeds. With the development of new engines having increased power and rotational speeds, however, the problems became of increasing importance.

Stack, John↗

One-Way Coupled Flow-Induced Vibration Analysis for a Twisted-Tube Heat Exchanger

The NEAMS program aims to develop an integrated multi-physics simulation capability “pellet-to-plant” for the design and analysis of future generations of nuclear power plants. In particular, the Reactor Product Line code suite's multi-resolution hierarchy is being designed to ultimately span the full range of length and time scales present in relevant reactor design and safety analyses, as well as scale from desktop to petaflop computing platforms. Flow-induced vibration (FIV) is a widespread problem in energy systems because they rely on fluid movement for energy conversion. Vibrating structures may be damaged as fatigue or wear occurs. Given the importance of reliable components in the nuclear industry, flow-induced vibration has long been a major concern in safety and operation of nuclear reactors. Nuclear fuel rods and steam generators have been known to suffer from flow-induced vibration and related failures.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Comparison of numerical simulation and experimental data for steam-in-place sterilization

A complex problem involving convective flow of a binary mixture containing a condensable vapor and noncondensable gas in a partially enclosed chamber was modelled and results compared to transient experimental values. The finite element model successfully predicted transport processes in dead-ended tubes with inside diameters of 0.4 to 1.0 cm. When buoyancy driven convective flow was dominant, temperature and mixture compositions agreed with experimental data. Data from 0.4 cm tubes indicate diffusion to be the primary air removal method in small diameter tubes and the diffusivity value in the model to be too large.

Young, Jack H.↗

The Thermal Response of a Packed Bed Thermal Energy Storage System upon Saturated Steam Injection Using Distributed Temperature Sensing

The effectiveness of a thermal energy storage (TES) system is typically characterized with the help of thermal stratification or temperature gradients along the direction of heat injection, which is typically the flow direction of heat transfer fluid. The steepness of temperature gradients are a direct indicator of the effectiveness or efficiency of the heat storage or dispatch process. The temperature gradient evolution along the packed bed of ceramic particles upon saturated steam injection is presented in this work. Distributed temperature sensing based on optical frequency domain reflectometry was deployed in a packed bed of ceramic particles to capture the thermal front evolution in the axial direction. The physical processes accompanying steam injection in packed beds are complex due to phase change, transitioning two-phase flow, and changes in condensate accumulation. Therefore, the variation of thermal response of the TES system for various steam injection flow rates was experimentally studied using a high-resolution distributed temperature sensing system in a chemically inert alumina particle-packed bed. Distinct zones of different heat transfer modes were observed during the steam injection experiments. A distinct conduction zone, evident from diffuse thermal fronts, was observed at low flow rates, and these thermal gradients became sharper as the flow rate increased. The diffuse thermal fronts in the heat storage media suggest a low exergy efficiency of the TES system, as energy losses started initiating before a significant fraction of the bed was saturated with steam.

25 ENERGY STORAGE↗

A High-Fidelity Approach for the Simulation of Flow-Induced Vibration

Flow-induced vibration (FIV) is a widespread problem in energy systems becausethey rely on fluid movement for energy conversion. Vibrating structures may be damaged as fatigue or wear occur. Given the importance of reliable components in the nuclear industry, flow-induced vibrations have long been a major concern in the safety and operation of nuclear reactors. In particular,nuclear fuel and steam generators have been known to suffer from flow-induced vibrations and related failures. Over the past five years, the Nuclear EnergyAdvanced Modeling and Simulation program has developed the integrated multiphysics code suite SHARP. The goal of developing such a tool is to perform multiphysics modeling of the components inside a reactor core, the full reactor core or portions of it, and be able to achieve that with various levelsof fidelity. This flexibility allows users to select the appropriate level of fidelity for their computational resources and design constraints.In particular SHARP contains high-fidelity single-physics codes for structural mechanics and fluid mechanics calculations: the structural mechanics implicit code Diablo and the computational fluid dynamics spectral element code Nek5000. Both codes are state-of-the-art.highly scalable (up to millions of processors in the case of Nek5000) tools that have been extensively validated. These tools form a strong basis on which to build an FIV modeling capability.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗