Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “standard normal variate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Method for simulating dose reduction in digital mammography using the Anscombe transformation

Purpose: This work proposes an accurate method for simulating dose reduction in digital mammography starting from a clinical image acquired with a standard dose. Methods: The method developed in this work consists of scaling a mammogram acquired at the standard radiation dose and adding signal-dependent noise. The algorithm accounts for specific issues relevant in digital mammography images, such as anisotropic noise, spatial variations in pixel gain, and the effect of dose reduction on the detective quantum efficiency. The scaling process takes into account the linearity of the system and the offset of the detector elements. The inserted noise is obtained by acquiring images of a flat-field phantom at the standard radiation dose and at the simulated dose. Using the Anscombe transformation, a relationship is created between the calculated noise mask and the scaled image, resulting in a clinical mammogram with the same noise and gray level characteristics as an image acquired at the lower-radiation dose. Results: The performance of the proposed algorithm was validated using real images acquired with an anthropomorphic breast phantom at four different doses, with five exposures for each dose and 256 nonoverlapping ROIs extracted from each image and with uniform images. The authors simulated lower-dose images and compared these with the real images. The authors evaluated the similarity between the normalized noise power spectrum (NNPS) and power spectrum (PS) of simulated images and real images acquired with the same dose. The maximum relative error was less than 2.5% for every ROI. The added noise was also evaluated by measuring the local variance in the real and simulated images. The relative average error for the local variance was smaller than 1%. Conclusions: A new method is proposed for simulating dose reduction in clinical mammograms. In this method, the dependency between image noise and image signal is addressed using a novel application of the Anscombe transformation. NNPS, PS, and local noise metrics confirm that this method is capable of precisely simulating various dose reductions.

60 APPLIED LIFE SCIENCES↗

Variations in tumor size and position due to irregular breathing in 4D-CT: A simulation study

Purpose: To estimate the position and volume errors in 4D-CT caused by irregular breathing. Methods: A virtual 4D-CT scanner was designed to reproduce axial mode scans with retrospective resorting. This virtual scanner creates an artificial spherical tumor based on the specifications of the user, and recreates images that might be produced by a 4D-CT scanner using a patient breathing waveform. 155 respiratory waveforms of patients were used to test the variability of 4D-CT scans. Each breathing waveform was normalized and scaled to 1, 2, and 3 cm peak-to-peak motion, and artificial tumors with 2 and 4 cm radius were simulated for each scaled waveform. The center of mass and volume of resorted 4D-CT images were calculated and compared to the expected values of center of mass and volume for the artificial tumor. Intrasubject variability was investigated by running the virtual scanner over different subintervals of each patient's breathing waveform. Results: The average error in the center of mass location of an artificial tumor was less than 2 mm standard deviation for 2 cm motion. The corresponding average error in volume was less than 4%. In the worst-case scenarios, a center of mass error of 1.0 cm standard deviation and volume errors of 30%-60% at inhale were found. Systematic errors were observed in a subset of patients due to irregular breathing, and these errors were more pronounced when the tumor volume is smaller. Conclusions: Irregular breathing during 4D-CT simulation causes systematic errors in volume and center of mass measurements. These errors are small but depend on the tumor size, motion amplitude, and degree of breathing irregularity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Snowmelt on the Greenland Ice Sheet as Derived From Passive Microwave Satellite Data

The melt extent of the snow on the Greenland ice sheet is of considerable importance to the ice sheet's mass and energy balance, as well as Arctic and global climates. By comparing passive microwave satellite data to field observations, variations in melt extent have been detected by establishing melt thresholds in the cross-polarized gradient ratio (XPGR). The XPGR, defined as the normalized difference between the 19-GHz horizontal channel and the 37-GHz vertical channel of the Special Sensor Microwave/Imager (SSM/I), exploits the different effects of snow wetness on different frequencies and polarizations and establishes a distinct melt signal. Using this XPGR melt signal, seasonal and interannual variations in snowmelt extent of the ice sheet are studied. The melt is found to be most extensive on the western side of the ice sheet and peaks in late July. Moreover, there is a notable increasing trend in melt area between the years 1979 and 1991 of 4.4% per year, which came to an abrupt halt in 1992 after the eruption of Mt. Pinatubo. A similar trend is observed in the temperatures at six coastal stations. The relationship between the warming trend and increasing melt trend between 1979 and 1991 suggests that a 1 C temperature rise corresponds to an increase in melt area of 73000 sq km, which in general exceeds one standard deviation of the natural melt area variability.

Abdalati, Waleed↗

Influence of Strain-Gage Balance Characteristics on the Precision Error of the Drag Coefficient

Improvements and results of a new method are presented that computes a pre-test estimate of the precision error of the drag coefficient of a wind tunnel model. The error estimate is defined as the part of the drag coefficient's precision error that is primarily associated with the precision error of the angle of attack measurement and physical characteristics of the chosen strain-gage balance. The method indirectly describes the precision error of the angle of attack measurement by using an assumed balance gage output variation of one microV/V. The physical characteristics of the balance, on the other hand, are described by partial derivatives of the axial and normal forces with respect to the strain-gage outputs. These derivatives can directly be obtained from the data reduction matrix of the balance. The precision error estimate itself is calculated by applying a simple explicit equation that uses the model reference area, the dynamic pressure, the angle of attack, the coefficients of the linear terms of the data reduction matrix, and the electrical output variation of one microvolt per volt as input. Precision errors at constant angle of attack may be visualized as contour plots by plotting them, for example, versus the Mach number and the total pressure. Characteristics of NASA's MC60E balance are used in combination with the reference area of a generic wind tunnel model in order to demonstrate that error estimates are independent of both the balance load format and the units chosen for the description of balance loads, model reference area, and the dynamic pressure. Finally, experimental data from a wind tunnel test of the Ames Check Standard Model in the NASA Ames 11-foot Transonic Wind Tunnel illustrates the application of the method to real-world test data.

precision error↗

MID-INFRARED SPECTRAL INDICATORS OF STAR FORMATION AND ACTIVE GALACTIC NUCLEUS ACTIVITY IN NORMAL GALAXIES

We investigate the use of mid-infrared (MIR) polycyclic aromatic hydrocarbon (PAH) bands, the continuum, and emission lines as probes of star formation (SF) and active galactic nucleus (AGN) activity in a sample of 100 'normal' and local (z {approx} 0.1) emission-line galaxies. The MIR spectra were obtained with the Spitzer Space Telescope Infrared Spectrograph as part of the Spitzer-SDSS-GALEX Spectroscopic Survey, which includes multi-wavelength photometry from the ultraviolet to the far-infrared and optical spectroscopy. The continuum and features were extracted using PAHFIT, a decomposition code which we find to yield PAH equivalent widths (EWs) up to {approx}30 times larger than the commonly used spline methods. Despite the lack of extreme objects in our sample (such as strong AGNs, low-metallicity galaxies, or ULIRGs), we find significant variations in PAH, continuum, and emission-line properties, and systematic trends between these MIR properties and optically derived physical properties, such as age, metallicity, and radiation field hardness. We revisit the diagnostic diagram relating PAH EWs and [Ne II]12.8 {mu}m/[O IV]25.9 {mu}m line ratios and find it to be in much better agreement with the standard optical SF/AGN classification than when spline decompositions are used, while also potentially revealing obscured AGNs. The luminosity of individual PAH components, of the continuum, and, with poorer statistics, of the neon emission lines and molecular hydrogen lines are found to be tightly correlated to the total infrared (TIR) luminosity, making individual MIR components good gauges of the total dust emission in SF galaxies. Like the TIR luminosity, these individual components can be used to estimate dust attenuation in the UV and in H{alpha} lines based on energy balance arguments. We also propose average scaling relations between these components and dust-corrected, H{alpha}-derived SF rates.

79 ASTRONOMY AND ASTROPHYSICS↗

A Simple Model of Cirrus Horizontal Inhomogeneity and Cloud Fraction

A simple model of horizontal inhomogeneity and cloud fraction in cirrus clouds has been formulated on the basis that all internal horizontal inhomogeneity in the ice mixing ratio is due to variations in the cloud depth, which are assumed to be Gaussian. The use of such a model was justified by the observed relationship between the normalized variability of the ice water mixing ratio (and extinction) and the normalized variability of cloud depth. Using radar cloud depth data as input, the model reproduced well the in-cloud ice water mixing ratio histograms obtained from horizontal runs during the FIRE2 cirrus campaign. For totally overcast cases the histograms were almost Gaussian, but changed as cloud fraction decreased to exponential distributions which peaked at the lowest nonzero ice value for cloud fractions below 90%. Cloud fractions predicted by the model were always within 28% of the observed value. The predicted average ice water mixing ratios were within 34% of the observed values. This model could be used in a GCM to produce the ice mixing ratio probability distribution function and to estimate cloud fraction. It only requires basic meteorological parameters, the depth of the saturated layer and the standard deviation of cloud depth as input.

Smith, Samantha A.↗

WE-D-303-05: Dosimetric Accuracy of CBCT Images Estimated by a Motion Modeling and Free-Form Deformation Technique for Radiotherapy of Lung Cancer

Purpose: To investigate the dosimetric accuracy of CBCTs estimated by a motion modeling and free-form deformation(MM-FD) technique for radiotherapy of lung cancer. Methods: Various inter-fractional variations featuring patient motion pattern change, tumor size change and tumor average position change were simulated from planning-CT to on-board images using both digital and physical motion phantoms. The doses calculated on the planning-CT (planned doses), the on-board CBCT estimated by MM-FD (MM-FD doses) and the on-board CBCT reconstructed by the conventional Feldkamp-Davis-Kress(FDK) algorithm (FDK doses) were compared to the on-board dose calculated on the ‘gold-standard’ on-board images (gold-standard doses). The absolute deviations of minimum dose (dDmin), maximum dose (dDmax), mean dose (dDmean) and dose coverage (dV100%) of PTV were evaluated. In addition, 4D on-board dose accumulations were performed using the 4D-CBCT images estimated by MM-FD. The accumulated doses were compared to measurements using OSL detectors and radiochromic films. Results: Of all the 50 scenarios simulated, the average(± standard deviation) dDmin, dDmax, dDmean and dV100% (values normalized by the prescription dose or the PTV volume) between the planned and the gold-standard PTV doses were 34.8% (± 29.2%), 3.2% (± 3.8%), 3.5% (± 3.5%) and 13.0% (± 11.4%), respectively. The corresponding values of FDK PTV doses were 3.1% (± 3.7%), 1.4% (± 1.1%), 2.1% (± 0.8%) and 14.5% (± 14.2%), respectively. In contrast, the corresponding values of MM-FD PTV doses were 0.4% (± 0.5%), 0.9% (± 0.7%), 0.6% (± 0.4%) and 0.9% (± 0.8%), respectively.For the 4D dose accumulation study, the average(± standard deviation) absolute dose deviation (normalized by local doses) between the accumulated doses and the OSL measured doses was 3.0% (± 2.4%). The average gamma pass-rate(3%/3mm) between the accumulated doses and the radiochromic film measured doses was 96.1%. Conclusion: MM-FD estimated CBCT enables accurate on-board dose calculation and accumulation for lung radiation therapy. The research was funded by the National Institutes of Health Grant No. R01-CA184173 and a grant from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Size effects on thermo-mechanical performance of U-10Mo monolithic fuel plates

Monolithic fuel is a fuel form that is considered for the conversion of high performance research reactors. This plate-type fuel consists of a high density U-Mo fuel in monolithic form that is sandwiched between zirconium diffusion barriers, and encapsulated in an aluminum cladding. To date, large number of plates have been irradiated with satisfactory perforamce. The program is now moving into the qualification phase, a predecessor to the timely conversion of the target reactors. It must be shown that the fuel system meets the safety standards and performs well in reactor. The requirement to satisfactory irradiation performance under normal operating conditions is primarily demonstrated by a successful testing. Since each reactor employs distinct fuel plate geometries for various consideration with unique plate design features and attributes, a single “generic” plate geometry capturing all of the extremities is not achievable. Furthermore, testing all these geometric and irradiation parameters on a large size plate is not practical. Therefore, a smaller, “down-scaled” versions of fuel plates, are often employed for experimental purposes. This limitation consequently requires much more cautious performance evaluations, as thermal and mechanical response of a plate with certain geometry may not be representative for a plate with a different geometry. To investigate if plate size has any effects on irradiation performance, the plates with various geometric dimensions were parametrically evaluated. In particular, length and width of the plates were varied between the bounding values. Temperature, deformation, stress values were comparatively evaluated. The results have indicated that effects of geometric ratios and plate size variations in length and width directions are insignificant. However, wider plates could become more prone to a warping-type deformation, if there are nonlinearities.

42 ENGINEERING↗

Size effects on thermo-mechanical performance of U-10Mo monolithic fuel plates

Monolithic fuel is a fuel form that is considered for the conversion of high performance research reactors. This plate-type fuel consists of a high density U-Mo fuel in monolithic form that is sandwiched between zirconium diffusion barriers, and encapsulated in an aluminum cladding. To date, large number of plates have been irradiated with satisfactory perforamce. The program is now moving into the qualification phase, a predecessor to the timely conversion of the target reactors. It must be shown that the fuel system meets the safety standards and performs well in reactor. The requirement to satisfactory irradiation performance under normal operating conditions is primarily demonstrated by a successful testing. Since each reactor employs distinct fuel plate geometries for various consideration with unique plate design features and attributes, a single “generic” plate geometry capturing all of the extremities is not achievable. Furthermore, testing all these geometric and irradiation parameters on a large size plate is not practical. Therefore, a smaller, “down-scaled” versions of fuel plates, are often employed for experimental purposes. This limitation consequently requires much more cautious performance evaluations, as thermal and mechanical response of a plate with certain geometry may not be representative for a plate with a different geometry. To investigate if plate size has any effects on irradiation performance, the plates with various geometric dimensions were parametrically evaluated. In particular, length and width of the plates were varied between the bounding values. Temperature, deformation, stress values were comparatively evaluated. The results have indicated that effects of geometric ratios and plate size variations in length and width directions are insignificant. However, wider plates could become more prone to a warping-type deformation, if there are nonlinearities.

42 ENGINEERING↗

Stress Analysis of Coated Particle Fuel in the Deep-Burn Pebble Bed Reactor Design

High fuel temperatures and resulting fuel particle coating stresses can be expected in a Pu and minor actinide fueled Pebble Bed Modular Reactor (400 MWth) design as compared to the ’standard’ UO2 fueled core. The high discharge burnup aimed for in this Deep-Burn design results in increased power and temperature peaking in the pebble bed near the inner and outer reflector. Furthermore, the pebble power in a multi-pass in-core pebble recycling scheme is relatively high for pebbles that make their first core pass. This might result in an increase of the mechanical failure of the coatings, which serve as the containment of radioactive fission products in the PBMR design. To investigate the integrity of the particle fuel coatings as a function of the irradiation time (i.e. burnup), core position and during a Loss Of Forced Cooling (LOFC) incident the PArticle STress Analysis code (PASTA) has been coupled to the PEBBED code for neutronics, thermal-hydraulics and depletion analysis of the core. Two deep burn fuel types (Pu with or without initial MA fuel content) have been investigated with the new code system for normal and transient conditions including the effect of the statistical variation of thickness of the coating layers.

99 GENERAL AND MISCELLANEOUS↗

Average motion, structure and orientation of the distant magnetotail determined from remote sensing of the edge of the plasma sheet boundary layer with E greater than 35 keV ions

We study gradients of the energetic ion intesity observed at the edge of the plasma sheet boundary layer (PSBL) by the energetic ion anisotropy spectrometer (EPAS) on International Sun Earth Explorer 3 (ISEE 3). In particular, we have determined the velocity of the boundary relative to the spacecraft in the direction perpendicular to the tail axis and the angle which the boundary normal makes to the spacecraft spin axis for 1160 PSBL encounters at X(sub GSM) greater than -240 R(sub E). By asuming that, on average, the edge of the PSBL is parallel to the cross-tail current sheet, we are then able to determine a number of properties of the structure, orientation and motion of the deep geomagnetic tail. We conclude the following: (1) Most crossings of the edge of the PSBL are caused by transverse motuion of the entire tail induced by solar wind direction variations, although some are caused by reconfiguration of the tail due to geomagnetic activity. (2) The typical velocity of the PSBL (and hence of the tail) in the direction perpendicular to the tail axis is 50-85 km/s. (3) The average twist of the tail is near zero, with the edge of the PSBL (and by inference the cross-tail current sheet) lying parallel to the ecliptic plane (however, large twists are found in individual events and the distribution of twists is broad, with one standard deviation of approximately 50 deg. (4) The width of the distribution decreases with downtail distance. (5) The variation of the distributions with cross-tail position reveals that this decreas in width is most likely due to the edge of the PSBL being concave, or significantly flared at the tail flanks, in the near-Earth region. (6) During days on which the Interplanetary Magnetic Field (IMF) has 'away' sector structure, the north lobe of the trail is twisted on average towards dawn by 7.0 +/-2.4 deg. (7) During days on which the IMF has 'toward' sector structure, the north lobe is tilted towards duskby 3.8 +/- 2.3. (8) A subset of events for which IMP 8 solar wind data are available show that, for southward IMF BH(sub z) the tail has a mean twist of -12.3 +/- 5.0 deg for IMF B(sub Y) greater than 0 and 5.5 +/- 3.8 deg for IMF B(sub Y) less than 0 (positive twist angles correspond to a tilt of the northern lobe towards dusk). (9) For northward IMF B(sub z) the tail has a twist of -23.9 +/- 5.0 deg for IMF B(sub Y) greater than 0 and 13.4 +/- 6.0 deg for IMF B(sub y) less than 0. Hence the tail appears more twisted on average for the IMF B(sub Z) northward case. (10) The distribution of tail twist is wider for lower levels of geomagnetic activity, indicating that the tail is able to twist more at lower levels of activity. (11) The data set reveals no evident effect of the earth's dipole wobble; tail orientation appears to be controlled by the solar wind and IMF, such that the GSE coordinate system may be appropriate for the study of field and plasma structures in the distant tail region.

Owen, C. J.↗

The role of ion-scale micro-turbulence in pedestal width of the DIII-D wide-pedestal QH mode

The low-edge rotation, intrinsically ELM-free, and improved confinement wide-pedestal quiescent H-mode (QH-mode), discovered in DIII-D tokamak, has pedestal widths exceeding the EPED-kinetic-ballooning mode (KBM) model scaling typically by at least 25%. Ion-scale ($k_yp_s$ < 1) microturbulence and its role in setting the pedestal structure is investigated using the radially local δ$f$ gyrokinetic code CGYRO. The electromagnetic trapped electron mode (TEM) is unstable at the pedestal top, while plasma beta (β$_e$) is ∼60% below the KBM onset threshold and the electron temperature gradient mode is found to be unstable in the peak gradient region. Nonlinear simulation reveals that the ion-scale turbulence could produce electron energy flux consistent with the flux inferred from power balance at the pedestal top, with a reasonable variation of the local shearing rate; and the local neoclassical transport from NEO is dominant over the simulated turbulent transport in the ion energy flux channel. The simulated ion-scale turbulence produces much lower electron energy flux than inferred from experiment in the pedestal peak gradient region. A correction to the EPED-KBM pedestal width scaling is obtained based on the two-dimensional scan of pedestal top plasma beta (β$_e$) and normalized electron density and temperature scale lengths,${a}$/${L_n}_e$, ${a}$/${L_T}_n$using CGYRO linear simulations. Mode transitions among TEM, micro-tearing mode, ion-temperature gradient mode and KBM, are observed in the 2D scan at the pedestal top. A fixed normalized growth rate for these drift-type modes is taken to determine the pedestal width scaling, which shows good consistency with the QH experimental database on pedestal heights and widths. The onset of KBM instabilities and the local E × B shear suppression criterion set the lower and upper limit for the pedestal width of standard QH-mode, wide-pedestal QH-mode and type-I ELMy H mode. A potentially higher and wider pedestal is expected from the new scaling of pedestal width. This work presents an improved understanding of the ion-scale micro-turbulence of wide-pedestal QH-mode and sheds light on a promising scenario for future reactors, including ITER and beyond.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cumulative sum quality control for calibrated breast density measurements

Purpose: Breast density is a significant breast cancer risk factor. Although various methods are used to estimate breast density, there is no standard measurement for this important factor. The authors are developing a breast density standardization method for use in full field digital mammography (FFDM). The approach calibrates for interpatient acquisition technique differences. The calibration produces a normalized breast density pixel value scale. The method relies on first generating a baseline (BL) calibration dataset, which required extensive phantom imaging. Standardizing prospective mammograms with calibration data generated in the past could introduce unanticipated error in the standardized output if the calibration dataset is no longer valid. Methods: Sample points from the BL calibration dataset were imaged approximately biweekly over an extended timeframe. These serial samples were used to evaluate the BL dataset reproducibility and quantify the serial calibration accuracy. The cumulative sum (Cusum) quality control method was used to evaluate the serial sampling. Results: There is considerable drift in the serial sample points from the BL calibration dataset that is x-ray beam dependent. Systematic deviation from the BL dataset caused significant calibration errors. This system drift was not captured with routine system quality control measures. Cusum analysis indicated that the drift is a sign of system wear and eventual x-ray tube failure. Conclusions: The BL calibration dataset must be monitored and periodically updated, when necessary, to account for sustained system variations to maintain the calibration accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Statistical Considerations of Data Processing in Giovanni Online Tool

The GES DISC Interactive Online Visualization and Analysis Infrastructure (Giovanni) is a web-based interface for the rapid visualization and analysis of gridded data from a number of remote sensing instruments. The GES DISC currently employs several Giovanni instances to analyze various products, such as Ocean-Giovanni for ocean products from SeaWiFS and MODIS-Aqua; TOMS & OM1 Giovanni for atmospheric chemical trace gases from TOMS and OMI, and MOVAS for aerosols from MODIS, etc. (http://giovanni.gsfc.nasa.gov) Foremost among the Giovanni statistical functions is data averaging. Two aspects of this function are addressed here. The first deals with the accuracy of averaging gridded mapped products vs. averaging from the ungridded Level 2 data. Some mapped products contain mean values only; others contain additional statistics, such as number of pixels (NP) for each grid, standard deviation, etc. Since NP varies spatially and temporally, averaging with or without weighting by NP will be different. In this paper, we address differences of various weighting algorithms for some datasets utilized in Giovanni. The second aspect is related to different averaging methods affecting data quality and interpretation for data with non-normal distribution. The present study demonstrates results of different spatial averaging methods using gridded SeaWiFS Level 3 mapped monthly chlorophyll a data. Spatial averages were calculated using three different methods: arithmetic mean (AVG), geometric mean (GEO), and maximum likelihood estimator (MLE). Biogeochemical data, such as chlorophyll a, are usually considered to have a log-normal distribution. The study determined that differences between methods tend to increase with increasing size of a selected coastal area, with no significant differences in most open oceans. The GEO method consistently produces values lower than AVG and MLE. The AVG method produces values larger than MLE in some cases, but smaller in other cases. Further studies indicated that significant differences between AVG and MLE methods occurred in coastal areas where data have large spatial variations and a log-bimodal distribution instead of log-normal distribution.

Suhung, Shen↗

On stability criteria for kinetic magnetohydrodynamics

The existence of a potential energy functional in the zero-Larmor-radius collisionless plasma theory of Kruskal & Oberman (Phys. Fluids, vol. 1, 1958 p. 275), Rosenbluth & Rostoker (Phys. Fluids, vol. 2, 1959, p. 23) allows us to derive easily sufficient conditions for linear stability. However, this kinetic magnetohydrodynamics (KMHD) theory does not have a self-adjointness property, making it difficult to derive necessary conditions. In particular, the standard methods to prove that an instability follows if some trial perturbation makes the incremental potential energy negative, which rely on the self-adjointness of the force operator or on the existence of a complete basis of normal modes, are not applicable to KMHD. This paper investigates KMHD linear stability criteria based on the time evolution of initial-value solutions, without recourse to the classic bounds or comparison theorems of Kruskal–Oberman and Rosenbluth–Rostoker for the KMHD potential energy. The adopted approach does not solve the kinetic equations by integration along characteristics and does not require that the particle orbits be periodic or nearly periodic. Most importantly, the investigation of a necessary condition for stability does not require the self-adjointness of the force operator or the existence of a complete basis of normal modes. Thus, it is thereby shown that stability in isothermal ideal-MHD is a sufficient condition for stability in KMHD and that, with a proviso on the long-time behaviour of oscillations about stable equilibria, stability in the double-adiabatic fluid theory, including the variation of the parallel fluid displacement, would be a necessary condition for stability in KMHD.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of spent nuclear fuel canister surface roughness using surface replicating molds

In this study we present a replication method to determine surface roughness and to identify surface features when a sample cannot be directly analyzed by conventional techniques. As a demonstration, this method was applied to an unused spent nuclear fuel dry storage canister to determine variation across different surface features. In this study, an initial material down-selection was performed to determine the best molding agent and determined that non-modified Polytek PlatSil23-75 provided the most accurate representation of the surface while providing good usability. Other materials that were considered include Polygel Brush-On 35 polyurethane rubber (with and without Pol-ease 2300 release agent), Polytek PlatSil73-25 silicone rubber (with and without PlatThix thickening agent and Pol-ease 2300 release agent), and Express STD vinylpolysiloxane impression putty. The ability of PlatSil73-25 to create an accurate surface replica was evaluated by creating surface molds of several locations on surface roughness standards representing ISO grade surfaces N 3 , N 5 , N 7 , and N 8 . Overall, the molds were able to accurately reproduce the expected roughness average (R a ) values, but systematically over-estimated the peak-valley maximum roughness (R z ) values. Using a 3D printed sample cell, several locations across the stainless steel spent nuclear fuel canister were sampled to determine the surface roughness. These measurements provided information regarding variability in normal surface roughness across the canister as well as a detailed evaluation on specific surface features (e.g., welds, grind marks, etc.). The results of these measurements can support development of dry storage canister ageing management programs, as surface roughness is an important factor for surface dust deposition and accumulation. This method can be applied more broadly to different surfaces beyond stainless steel to provide rapid, accurate surface replications for analytical evaluation by profilometry.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Estimating Net Primary Productivity Using Satellite and Ancillary Data

The net primary productivity (C) or annual rate of carbon accumulation per unit ground area by terrestrial plant communities is the difference of the rate of gross photosynthesis (A(sub g)) and autotrophic respiration (R) per unit ground area. Although available observations show that R is a large and variable fraction of A(sub g), viz., 0.3 to 0.7, it is generally recognized that much uncertainties exist in this fraction due to difficulties associated with the needed measurements. Additional uncertainties arise when these measurements are extrapolated to regional or global land surface using empirical equations, for example, using regression equations relating C to mean annual precipitation and air temperature. Here, a process-based approach has been taken to calculate A(sub g) and R using satellite and ancillary data. A(sub g) has been expressed as a product of radiation use efficiency, magnitude of intercepted photosynthetically active radiation (PAR), and normalized by stresses due to soil water shortage and air temperature away from the optimum range. A biophysical model has been used to determine the radiation use efficiency from the maximum rate of carbon assimilation by a leaf, foliage temperature, and the fraction of diffuse PAR incident on a canopy. All meteorological data (PAR, air temperature, precipitation, etc.) needed for the calculation are derived from satellite observations, while a land use, land cover data (based on satellite and ground measurements) have been used to assess the maximum rate of carbon assimilation by a leaf of varied cover type based on field measurements. R has been calculated as the sum of maintenance and growth components. The maintenance respiration of foliage and live fine roots at a standard temperature of different land cover has been determined from their nitrogen content using field and satellite measurements, while that of living fraction of woody stem (viz., sapwood) from the seasonal maximum leaf area index as determined from satellite observations. These maintenance respiration values were then adjusted to that corresponding to air temperature according to a prescribed non-linear variation of respiration with temperature. The growth respiration has been calculated from the difference of Ag and maintenance respiration, according to the two-compartment model. The results of calculations will be reported for 36 consecutive months (1987-1989) over large contiguous areas (ca. 10(exp 5) sq km) Of agricultural land and tropical humid evergreen forests, and compared with available field data.

Choudhury, B. J.↗

Fe Kα XANES, Fe Kβ HERFD XANES and EPMA flank method determinations of the oxidation state of Fe in garnet

The ferric to total iron ratios (Fe 3+ /ΣFe) of garnets can be paired with thermodynamic mineral activity models to quantify the oxygen fugacity of garnet-bearing rocks. However, techniques with a high analytical and spatial resolution are necessary to distinguish differences in garnet Fe 3+ /ΣFe ratios at the percent level and to accurately measure garnets that are zoned or contain inclusions. We acquired conventional Fe Kα and high-resolution energy fluorescence detection (HERFD) Fe Kβ X-ray absorption near edge structure (XANES) spectra and electron microprobe flank method analyses on a suite of 27 peridotitic and eclogitic garnets with Fe 3+ /ΣFe ratios previously determined by Mössbauer spectroscopy to evaluate the precision of each technique. We examined variations in the energy and intensity of three XANES spectral features as a function of Fe 3+ /ΣFe ratios: 1) the intensity ratio of two-post edge features (I-ratio; Fe Kα only); 2) the energy of the Fe edge at 90% normalized intensity (E 0.9 ; Fe Kα only) and 3) the pre-edge centroid energy (Fe Kα and HERFD Fe Kβ). In accordance with previous work, we find the energies of garnet pre-edge centroids are relatively insensitive to Fe 3+ /ΣFe ratios. The I-ratios of peridotitic and eclogitic garnets are offset from each other at low Fe 3+ /ΣFe ratios (≤0.13); I-ratio garnet XANES calibrations are composition-specific. The E 0.9 feature is independent of garnet major element composition in spectra that have been corrected for the effects of self-absorption. We produce two Fe Kα garnet XANES calibrations based on variations in the E0.9 feature; one calibration with all garnet reference materials included (Fe 3+ /ΣFe up to 1.0; “all garnet calibration”) and another calibration specific to garnets with low Fe 3+ /ΣFe ratios (“low ferric calibration”). Fe 3+ /ΣFe ratios calculated from the mean of up to 25 flank method measurements on eight garnet reference materials fall within 4% absolute of a one-to-one correlation with Fe 3+ /ΣFe ratios measured by Mössbauer. The standard error of the mean Fe 3+ /ΣFe ratio calculated from flank method approaches the Mössbauer-determined Fe 3+ /ΣFe ratio within estimated error (3%) after three analyses. Flank method precision is enhanced at higher beam current; however, the precision of the flank method does not approach the precision of XANES under any microprobe analytical condition tested here. Garnet reference materials detailed here are available by request to the Smithsonian Institution.

58 GEOSCIENCES↗