Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spectrum monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Spectroscopic observations of beam and source plasma light and testing Cs-deposition monitor in the large area negative ion source for LHD-NBI

In the large area negative ion source for the LHD negative-ion-(H{sup -})-based neutral beam system, (I) we used the spectrometer to measure caesium lines in the source plasma during beam shots. (II) With Doppler-shifted measurements, the H{sub {alpha}} line at three different locations along the beam as well as the spectrum profile for cases of different plasma grid areas. (III) Caesium deposition monitor with a high speed shutter was tested to measure the weight of the deposited Cs layer. In the observation, cleaner spectra of Doppler-shifted H{sub {alpha}} line with only a small level of background light were obtained at a new observation port which viewed the blueshifted light in the drift region after the accelerator of a LHD ion source. Both the amounts of Cs I (852 nm, neutral Cs{sup 0}) and Cs II (522 nm, Cs{sup +}) in the source plasma light rose sharply when beam acceleration began, and continued rising during a 10 s pulse. It was thought that this was because the cesium was evaporated/sputtered from the source back plate by the back-streaming positive ions. Cs deposition rate to the crystal sensor measured by adjusting the shutter open time was evaluated to be 2.9 nanograms/s cm{sup 2} for preliminary testing. More neutral Cs tended to be evolved in the source after arc discharge. Much Cs could be consumed in a high rate-pulsed operation (such as LHD source)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

FTIR Monitoring Of Curing Of Composites

Infrared-sensing optical fiber system developed to monitor principal infrared absorption bands resulting from vibrations of atoms and molecules as chemical bonds form when resin cured. System monitors resin chemistry more directly. Used to obtain Fourier transform infrared (FTIR) spectrum from graphite fiber/polyimide matrix resin prepreg. Embedded fiber optic FTIR sensor used to indicate state of cure of thermosetting composite material. Developed primarily to improve quality of advanced composites, many additional potential applications exist because principal of operation applicable to all organic materials and most inorganic gases. Includes monitoring integrities of composite materials in service, remote sensing of hazardous materials, and examination of processes in industrial reactors and furnaces.

Druy, Mark A.↗

Antineutrino Monitoring of Spent Nuclear Fuel

Military and civilian applications of nuclear energy have left a significant amount of spent nuclear fuel over the past 70 years. Currently, in many countries worldwide, the use of nuclear energy is on the rise. Therefore, the management of highly radioactive nuclear waste is a pressing issue. In this work, we explore antineutrino detectors as a tool for monitoring and safeguarding nuclear-waste material. We compute the flux and spectrum of antineutrinos emitted by spent nuclear fuel elements as a function of time, and we illustrate the usefulness of antineutrino detectors in several benchmark scenarios. In particular, we demonstrate how a measurement of the antineutrino flux can help to reverify the contents of a dry storage cask in case the monitoring chain by conventional means gets disrupted. We then comment on the usefulness of antineutrino detectors at long-term storage facilities such as Yucca mountain. Finally, we put forward antineutrino detection as a tool in locating underground “hot spots” in contaminated areas such as the Hanford site in Washington state.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

XTE Proposal #20102--"SS 433's High Energy Spectrum"

We observed the jet-producing compact binary system SS 433 with RXTE during three multiwavelength campaigns, the first in conjunction with ASCA observations, the second simultaneous with a VLA-VLBA-MERLIN campaign, and the third associated with a Nobeyama millimeter-band campaign. All these campaigns included optical observations. Occurring at different jet precession and binary phases, the observations also monitored the system during a radio flare. The data provide SS 433's X-ray spectrum over more than an energy decade, and track the spectral variations as the X-ray source was partially eclipsed. The continuum can be modeled as a power law with an exponential cutoff, which can be detected to approximately 50 keV. Strong line emission is evident in the 5-10 keV range which can be modeled as a broad line whose energy is precession independent and a narrow line whose energy does vary with jet precession phase; this line model is clearly an over simplification since the PCA does not have sufficient energy resolution to detect the lines ASCA observed. The eclipses are deeper at high energy and at jet precession phases when the jets are more inclined towards and away from us. A large radio flare occurred between two sets of X-ray monitoring observations; an X-ray observation at the peak of the flare found a softer spectrum with a flux approximately 1/3 that of the quiescent level.

Band, David L.↗

Applications of LIF to Document Natural Variability of Chlorophyll Content and Cu Uptake in Moss

Chlorophyll has long been used as a natural indicator of plant health and photosynthetic efficiency. Laser-induced fluorescence (LIF) is an emerging technique for understanding broad spectrum organic processes and has more recently been used to monitor chlorophyll response in plants. Previous work has focused on developing a LIF technique for imaging moss mats to identify metal contamination with the current focus shifting toward application to moss fronds and aiding sample collection for chemical analysis. Two laser systems (CoCoBi a Nd:YGa pulsed laser system and Chl-SL with two blue continuous semiconductor diodes) were used to collect images of moss fronds exposed to increasing levels of Cu (1, 10, and 100 nmol/cm 2 ) using a CMOS camera. The best methods for the preprocessing of images were conducted before the analysis of fluorescence signatures were compared to a control. The Chl-SL system performed better than the CoCoBi, with dynamic time warping (DTW) proving the most effective for image analysis. Manual thresholding to remove lower decimal code values improved the data distributions and proved whether using one or two fronds in an image was more advantageous. A higher DTW difference from the control correlated to lower chlorophyll a/b ratios and a higher metal content, indicating that LIF, with the aid of image processing, can be an effective technique for identifying Cu contamination shortly after an event.

59 BASIC BIOLOGICAL SCIENCES↗

On the detectability of millimeter wavelength spectral lines from planetary atmospheres

This paper adopts a simple line-formation model to estimate detection limits on the fractional absorption produced by molecular lines in the spectra of the planets, when observed with the 14-m antenna and low-noise receivers of the Five College Radio Astronomy Observatory. The results, which can readily be adjusted for receiver and telescope characteristics of other observatories, indicate that three kinds of observing programs may prove fruitful: (1) programs to monitor temporal variations of the strong CO absorption in the spectrum of Venus and Mars; (2) searches for weak absorption lines of other molecules, which are particularly promising for Venus: and (3) efforts to measure broad features in the continuous spectra of Venus, and possibly Jupiter, produced by molecules deep in the planetary atmospheres. Except for delineation of broad features of NH3 and possibly H2O near 25 GHz, hardly any useful observations can be made at frequencies less than 60 GHz.

White, R. E.↗

Automatic communication signal monitoring system

A system is presented for automatic monitoring of a communication signal in the RF or IF spectrum utilizing a superheterodyne receiver technique with a VCO to select and sweep the frequency band of interest. A first memory is used to store one band sweep as a reference for continual comparison with subsequent band sweeps. Any deviation of a subsequent band sweep by more than a predetermined tolerance level produces an alarm signal which causes the band sweep data temporarily stored in one of two buffer memories to be transferred to long-term store while the other buffer memory is switched to its store mode to assume the task of temporarily storing subsequent band sweeps.

Bernstein, A. J.↗

IUE observations of the X-ray source HZ Herculis/Her X-1

The results of a campaign of monitoring HZ Her with the IUE satellite are presented. The spectrum and light variation outside of eclipse are fairly consistent with the Milgrom and Salpeter (1975) model for emission from the X-ray heated photosphere of the primary. Near eclipse there is UV flux in excess of the prediction of the heated photosphere model. This suggests an additional emitting component whose relative importance decreases toward shorter wavelengths. The excess flux near 1500A appears to vary with 35 day phase in a manner consistent with the model of Gerend and Boynton (1976) in which the flux contributed by the accretion disk is modulated by precession.

Gursky, H.↗

The observations of the X-ray source HZ Herculis/Hercules X-1

The results of a campaign of monitoring HZ Her with the IUE satellite are presented. The spectrum and light variation outside of eclipse are consistent with the Milgrom and Salpeter model for emission from the X-ray heated photosphere of the primary. Near eclipse there is UV flux in excess of the prediction of the heated photosphere model, which shows significant 35 day variations and is consistent with an origin in a precessing disk, as described by Gerend and Boynton. The spectrum shows the strong emission lines of N V and C IV, which generally vary in the sense of the continuum. The N V/C IV ratio is greater than 2 near orbital phase 0.5 and approaches unity near eclipse. It is suggested that these emission lines are optically thick and arise from both the heated photosphere and the accretion disk.

Gursky, H.↗

Kelvin wave-induced trace constituent oscillations in the equatorial stratosphere

Kelvin wave induced oscillations in ozone (O3), water vapor (H2O), nitric acid (HNO3) and nitrogen dioxide (NO2) in the equatorial stratosphere are analyzed using Limb Infrared Monitor of the Stratosphere (LIMS) data. Power and cross-spectrum analyses reveal coherent eastward propagating zonal wave 1 and 2 constituent fluctuations, due to the influence of Kelvin waves previously documented in the LIMS data. Comparison is made between a preliminary and the archival versions of the LIMS data; significant differences are found, demonstrating the sensitivity of constituent retrievals to derived temperature profiles. Because Kelvin waves have vanishing meridional velocity, analysis of tracer transport in the meridional plane is substantially simplified. Kelvin wave vertical advection is demonstrated by coherent, in-phase temperature-tracer oscillations, co-located near regions of strong background vertical gradients.

Randel, William J.↗

Coarsening following a morphological instability in the one-sided model

We study the coarsening of the interfacial pattern separating two coexisting phases after the pattern becomes morphologically unstable. Shortly after the instability, the scale of the structure is given by the most unstable wave number in the linear regime. At later times, nonlinear interactions cause the structure to coarsen. Coarsening is studied by monitoring the time dependence of the two-dimensional power spectrum of the pattern, especially for wave vectors transverse to the direction of growth. Characteristic length scales of the pattern obtained from moments of the power spectrum are asymptotically linear in time. Furthermore, the power spectrum is seen to satisfy a scaling relation, in agreement with previous studies. A normal-velocity autocorrelation function is calculated and found to decay substantially over length scales that are of the order of the scale of the pattern. The issue of spatial anisotropy in the correlation functions is also discussed.

Vinals, Jorge↗

Small satellite space operations

CTA Space Systems has played a premier role in the development of the 'lightsat' programs of the 80's and 90's. The high costs and development times associated with conventional LEO satellite design, fabrication, launch, and operations continue to motivate the development of new methodologies, techniques, and generally low cost and less stringently regulated satellites. These spacecraft employ low power 'lightsat' communications (versus TDRSS for NASA's LEO's) and typically fly missions with payload/experiment suites that can succeed, for example, without heavily redundant backup systems and large infrastructures of personnel and ground support systems. Such small yet adaptable satellites are also typified by their very short contract-to-launch times (often one to two years). This paper reflects several of the methodologies and perspectives of our successful involvement in these innovative programs and suggests how they might relieve NASA's mounting pressures to reduce the cost of both the spacecraft and their companion mission operations. It focuses on the use of adaptable, sufficiently powerful yet inexpensive PC-based ground systems for wide ranging user terminal (UT) applications and master control facilities for mission operations. These systems proved themselves in successfully controlling more than two dozen USAF, USN, and ARPA satellites at CTA/SS. UT versions have linked with both GEO and LEO satellites and functioned autonomously in relay roles often in remote parts of the world. LEO applications particularly illustrate the efficacy of these concepts since a user can easily mount a lightweight antenna, usually an omni or helix with light duty rotors and PC-based drivers. A few feet of coax connected to a small transceiver module (the size of a small PC) and a serial line to an associated PC establishes a communications link and together with the PC constitute a viable ground station. Applications included geomagnetic mapping; spaceborne solid state recorder validation; global store-and-forward data communications for both scientific and military purposes such as Desert Storm; UHF transponder services for both digital data and voice using a constellation; remote sensor monitoring of weather and oceanographic conditions; classified payloads; and UHF spectrum surveillance. Ground processing has been accomplished by automatic unattended or manual operation. Management of multiple assets highlights the relative ease with which two constellations totaling nine satellites were controlled from one system including constellation station keeping. Our experience in small end-to-end systems including concurrent design, development, and testing of the flight and operational ground systems offers low cost approaches to NASA scientific satellite operations of the 1990's.

Reiss, Keith↗

Investigation and Development of Data-Driven D-Region Model for HF Systems Impacts

Space Environment Corporation (SEC) and RP Consultants (RPC) are to develop and validate a weather-capable D region model for making High Frequency (HF) absorption predictions in support of the HF communications and radar communities. The weather-capable model will assimilate solar and earth space observations from NASA satellites. The model will account for solar-induced impacts on HF absorption, including X-rays, Solar Proton Events (SPE's), and auroral precipitation. The work plan includes: I . Optimize D-region model to quickly obtain ion and electron densities for proper HF absorption calculations. 2. Develop indices-driven modules for D-region ionization sources for low, mid, & high latitudes including X-rays, cosmic rays, auroral precipitation, & solar protons. (Note: solar spectrum & auroral modules already exist). 3. Setup low-cost monitors of existing HF beacons and add one single-frequency beacon. 4. Use PENEX HF-link database with HF monitor data to validate D-region/HF absorption model using climatological ionization drivers. 5. Develop algorithms to assimilate NASA satellite data of solar, interplanetary, and auroral observations into ionization source modules. 6. Use PENEX HF-link & HF-beacon data for skill score comparison of assimilation versus climatological D-region/HF absorption model. Only some satellites are available for the PENEX time period, thus, HF-beacon data is necessary. 7. Use HF beacon monitors to develop HF-link data assimilation algorithms for regional improvement to the D-region/HF absorption model.

Eccles, J. V.↗

Landsat-7 ETM+ On-Orbit Reflective-Band Radiometric Stability and Absolute Calibration

The Landsat-7 spacecraft carries the Enhanced Thematic Mapper Plus (ETM+) instrument. This instrument images the Earth land surface in eight parts of the electromagnetic spectrum, termed spectral bands. These spectral images are used to monitor changes in the land surface, so a consistent relationship, i.e., calibration, between the image data and the Earth surface brightness, is required. The ETM+ has several on- board calibration devices that are used to monitor this calibration. The best on-board calibration source employs a flat white painted reference panel and has indicated changes of between 0.5% to 2% per year in the ETM+ response, depending on the spectral band. However, most of these changes are believed to be caused by changes in the reference panel, as opposed to changes in the instrument's sensitivity. This belief is based partially on on-orbit calibrations using instrumented ground sites and observations of "invariant sites", hyper-arid sites of the Sahara and Arabia. Changes determined from these data sets indicate are 0.1% - 0.6% per year. Tests and comparisons to other sensors also indicate that the uncertainty of the calibration is at the 5% level.

FROM↗

Fabrication and Testing of Micro Flux Monitors in the High Flux Isotope Reactor

Neutron dosimetry is a critical technique to measure the neutron flux, fluence, and energy spectrum of nuclear reactors and can be used to indicate fuel reloading, high-power operations, or changes in cycle length. This work presents results of a novel device named the micro flux monitor, which is a miniaturized neutron dosimeter made from small quantities (100s of nanograms) of Ti, Al, Ni, and Au metals deposited on Si and high-purity fused silica substrates using standard semiconductor fabrication techniques. Approximately 1,250 of these devices were produced, and 40 were irradiated in the pneumatic tube facility of the Neutron Activation Analysis Laboratory at the High Flux Isotope Reactor. Testing demonstrated that dosimeter metals can be deposited predictably and repeatedly in multiple geometries, including as quick response (QR) codes. Neutron flux measurements with these devices were within 3% of measurements made using standard flux monitors, demonstrating the efficacy of these devices. Devices were also tested at 500°C under a N2 atmosphere and showed minimal degradation, suggesting they could be deployed for neutron dosimetry measurements in high-temperature advanced reactors.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Analysis of long term heart rate variability: methods, 1/f scaling and implications

The use of spectral techniques to quantify short term heart rate fluctuations on the order of seconds to minutes has helped define the autonomic contributions to beat-to-beat control of heart rate. We used similar techniques to quantify the entire spectrum (0.00003-1.0 Hz) of heart rate variability during 24 hour ambulatory ECG monitoring. The ECG from standard Holter monitor recordings from normal subjects was sampled with the use of a phase locked loop, and a heart rate time series was constructed at 3 Hz. Frequency analysis of the heart rate signal was performed after a nonlinear filtering algorithm was used to eliminate artifacts. A power spectrum of the entire 24 hour record revealed power that was inversely proportional to frequency, 1/f, over 4 decades from 0.00003 to 0.1 Hz (period approximately 10 hours to 10 seconds). Displaying consecutive spectra calculated at 5 minute intervals revealed marked variability in the peaks at all frequencies throughout the 24 hours, probably accounting for the lack of distinct peaks in the spectra of the entire records.

Non-NASA Center↗