Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “solutions center”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

The HPC Container Experience on the Summit Supercomputer

Containers are seeing widespread use in the world of High Performance Computing, with many HPC Centers either providing their own containerization solution or adopting existing ones like Singularity and Apptainer. The demand for containerization options come from users who want to take advantage of the portability and reproducibility containers can provide, as well as being able to build and use applications that are only distributed in container form or are otherwise unsuited to natively run in an HPC environment. The users served by the Oak Ridge Leadership Computing Facility are no exception. We go over the past and current containerization offerings at the Oak Ridge Leadership Computing Facility, mainly focusing on the Summit supercomputer. We arrive at using a combination of Podman and Singularity to allow users to build and run containers directly on Summit, without requiring external resources or hardware for any step of the process. We look at a couple of projects running on Summit that greatly benefited from being able to use containers on Summit. And we compare benchmarks running natively and in containers on Summit at different scales, observing minimal performance difference and consistent behavior across all tests.

Abraham, Subil↗

An analytic guidance technique for planetary and lunar approach trajectories.

An explicit, analytic guidance technique is developed for the hyperbolic approach phases of interplanetary and lunar spacecraft trajectories. The guidance technique is based upon a first-order analytic solution for the perturbed planet-centered (or moon-centered) trajectory. This trajectory is represented as the sum of two components: (1) the unperturbed osculating hyperbola at pericenter, and (2) first-order position and velocity perturbations due to gravitational effects of the sun and other planets. A closed-form analytic approximation for these perturbations valid for the entire approach trajectory is derived, thereby eliminating the need for numerical integration of the equations of motion. By means of this analytic trajectory model, the approach guidance problem is reduced to an equivalent two-body problem. The guidance objectives are specified in terms of actual, attainable conditions at pericenter, and the required corrective velocity is determined explicitly for both fixed and variable times of arrival.

Carlson, N. A.↗

The figure of Mars and its effect on radar-ranging.

Formulae are given which indicate the errors made in computing the radar-range to a planet when one assumes the planet to have a spherical surface, centered at the center of mass. These formulae are evaluated for Mars, using an ellipsoidal fit of the martian surface obtained from the occultation measurements of the Mariner 9 spacecraft. The secularlike part of the errors amounts to about 4 km in range over the past 3 oppositions, due mainly to the flattening of 0.006 and to a 3 km southerly displacement of the center of figure from the center of mass. The method of solution is given in the appendix along with a method for applying the ellipsoidal model to the reduction of radar-range data.

Standish, E. M., Jr.↗

Correlations between solar activity and operationally determined satellite drag variation parameters

Operational orbit determination of the Earth Radiation Budget Satellite (ERBS) and the Solar Maximum Mission (SMM) spacecraft using the Goddard Trajectory Determination System (GTDS) in the Flight Dynamics Facility (FDF) of the Goddard Space Flight Center (GSFC) has yielded an orbit solution data base of 3 years for ERBS and 8 years for SMM. One of the parameters in each data base is the drag variation parameter used in the GTDS atmospheric drag model; this parameter is solved routinely to accommodate the different atmospheric densities as they are encountered solution to solution. These two data bases of the drag variation parameter solutions are analyzed to evaluate correlations in the variations of the parameter with changes in the 10.7-cm wavelength solar flux, F10.7, and the geomagnetic index. The data for SMM span a wider range of solar flux values and show a stronger correlation. The data for ERBS, which is at a higher altitude and inclination than SMM, show a significant degree of scatter. For both satellites, the data indicate that changes in the drag variation parameter are more strongly correlated with the F10.7 solar flux than with the geomagnetic index. Correlations with the geomagnetic index are apparent only for severe geomagnetic storm conditions. Results from this analysis enhance the understanding of the drag model and the accommodation density variations in operational orbit determination support.

Smith, E. A.↗

A simplified self-adaptive grid method, SAGE

The formulation of the Self-Adaptive Grid Evolution (SAGE) code, based on the work of Nakahashi and Deiwert, is described in the first section of this document. The second section is presented in the form of a user guide which explains the input and execution of the code, and provides many examples. Application of the SAGE code, by Ames Research Center and by others, in the solution of various flow problems has been an indication of the code's general utility and success. Although the basic formulation follows the method of Nakahashi and Deiwert, many modifications have been made to facilitate the use of the self-adaptive grid method for single, zonal, and multiple grids. Modifications to the methodology and the simplified input options make this current version a flexible and user-friendly code.

Davies, C.↗

Comparison of 3-D viscous flow computations of Mach 5 inlet with experimental data

A time marching 3-D full Navier-Stokes code, called PARC3D, is validated for an experimental Mach 5 inlet configuration using the data obtained in the 10 x 10 ft supersonic wind tunnel at the NASA Lewis Research Center. For the first time, a solution is obtained for this configuration with the actual geometry, the tunnel conditions, and all the bleed zones modeled in the computation. Pitot pressure profiles and static pressures at various locations in the inlet are compared with the corresponding experimental data. The effect of bleed zones, located in different places on the inlet walls, in eliminating the low energy vortical flow generated from the 3-D shock-boundary layer interaction is simulated very well even though some approximations are used in applying the bleed boundary conditions and in the turbulence model. A further detailed study of the effect of individual bleed ports is needed to understand fully the actual mechanism of efficiently eliminating the vortical flow from the inlet. A better turbulence model would help to improve the accuracy even further in predicting the corner flow boundary layer profiles.

Reddy, D. R.↗

Discrete-vortex model for the symmetric-vortex flow on cones

A relatively simple but accurate potential flow model was developed for studying the symmetric vortex flow on cones. The model is a modified version of the model first developed by Bryson, in which discrete vortices and straight-line feeding sheets were used to represent the flow field. It differs, however, in the zero-force condition used to position the vortices and determine their circulation strengths. The Bryson model imposed the condition that the net force on the feeding sheets and discrete vortices must be zero. The proposed model satisfies this zero-force condition by having the vortices move as free vortices, at a velocity equal to at the local crossflow velocity at their centers. When the free-vortex assumption is made, a solution is obtained in the form of two nonlinear algebraic equations that relate the vortex center coordinates and vortex strengths to the cone angle and angle of attack. The vortex center locations calculated using the model are in good agreement with experimental values. The cone normal forces as well as center locations are in good agreement with the vortex cloud method of calculating symmetric flow fields.

Gainer, Thomas G.↗

Unstructured grid methods for compressible flows

The implementation of the finite element method on unstructured triangular grids is described and the development of centered finite element schemes for the solution of the compressible Euler equation on general triangular and tetrahedral grids is discussed. Explicit and implicit Lax-Wendroff type methods and a method based upon the use of explicit multistep timestepping are considered. In the latter case, the convergence behavior of the method is accelerated by the incorporation of a fully unstructured multigrid procedure. The advancing front method for generating unstructured grids of triangles and tetrahedra is described and the application of adaptive mesh techniques to both steady and transient flow analysis is illustrated.

Morgan, K.↗

Improved Slip Casting Of Ceramic Models

Improved technique of investment slip casting developed for making precise ceramic wind-tunnel models. Needed in wind-tunnel experiments to verify predictions of aerothermodynamical computer codes. Ceramic materials used because of their low heat conductivities and ability to survive high temperatures. Present improved slip-casting technique enables casting of highly detailed models from aqueous or nonaqueous solutions. Wet shell molds peeled off models to ensure precise and undamaged details. Used at NASA Langley Research Center to form superconducting ceramic components from nonaqueous slip solutions. Technique has many more applications when ceramic materials developed further for such high-strength/ temperature components as engine parts.

Buck, Gregory M.↗

Mission activities planning for a Hermes mission by means of AI-technology

Mission Activities Planning is a complex task to be performed by mission control centers. AI technology can offer attractive solutions to the planning problem. This paper presents the use of a new AI-based Mission Planning System for crew activity planning. Based on a HERMES servicing mission to the COLUMBUS Man Tended Free Flyer (MTFF) with complex time and resource constraints, approximately 2000 activities with 50 different resources have been generated, processed, and planned with parametric variation of operationally sensitive parameters. The architecture, as well as the performance of the mission planning system, is discussed. An outlook to future planning scenarios, the requirements, and how a system like MARS can fulfill those requirements is given.

Pape, U.↗

Two-phase flow research using the learjet apparatus

Low-gravity, gas-liquid flow research can be conducted aboard the NASA Lewis Learjet, the Lewis DC-9, or the Johnson Space Center KC-135. Air and water solutions serve as the test liquids in cylindrical test sections with an inner diameter of 1.27 cm and lengths up to 1.5 m. Superficial velocities range from 0.1 to 1.1 m/sec for liquids and from 0.1 to 25 m/sec for air. Flow rate, differential pressure, void fraction, film thickness, wall-shear stress, and acceleration data are measured and recorded throughout the 20 sec duration of the experiment. Flow is visualized by photographing at 400 frames with a high-speed, 16-mm camera.

Mcquillen, John B.↗

Two-phase flow research using the DC-9/KC-135 apparatus

Low-gravity gas-liquid flow research can be conducted aboard the NASA Lewis Research Center DC-9 or the Johnson Space Center KC-135. Air and water solutions serve as the test liquids in cylindrical test sections with constant or variable inner diameters of approximately 2.54 cm and lengths of up to 3.0 m. Superficial velocities range from 0.1 to 1.1 m/sec for liquids and from 0.1 to 25 m/sec for air. Flow rate, differential pressure, void fraction, film thickness, wall shear stress, and acceleration data are measured and recorded at data rates of up to 1000 Hz throughout the 20-sec duration of the experiment. Flow is visualized with a high-speed video system. In addition, the apparatus has a heat-transfer capability whereby sensible heat is transferred between the test-section wall and a subcooled liquid phase so that the heat-transfer characteristics of gas-liquid two-phase flows can be determined.

McQuillen, John B.↗

Satellite Communications for Aeronautical Applications: Recent research and Development Results

Communications systems have always been a critical element in aviation. Until recently, nearly all communications between the ground and aircraft have been based on analog voice technology. But the future of global aviation requires a more sophisticated "information infrastructure" which not only provides more and better communications, but integrates the key information functions (communications, navigation, and surveillance) into a modern, network-based infrastructure. Satellite communications will play an increasing role in providing information infrastructure solutions for aviation. Developing and adapting satellite communications technologies for aviation use is now receiving increased attention as the urgency to develop information infrastructure solutions grows. The NASA Glenn Research Center is actively involved in research and development activities for aeronautical satellite communications, with a key emphasis on air traffic management communications needs. This paper describes the recent results and status of NASA Glenn's research program.

Kerczewski, Robert J.↗

Eye Surgery Light

During eye surgery, the surgeon uses an illuminating instrument called an opthalmoscope for close examination of the retina or the interior of the eye. Ordinarily, electric power for the head-mounted light is supplied through a cord from an overhead swivel arm or a floor pedestal. Within limits of cord length and swivel arm movement, the surgeon has considerable freedom of motion. But when more than one opthalmoscope is involved, tangling and interference of the power cords becomes a problem. St. Luke's Hospital, Cleveland, Ohio asked Lewis Research Center for assistance in finding a solution. Lewis responded with a battery-powered system that totally frees the surgeon of attached cords and swivels. Borrowing from space technology, Lewis used small, lightweight nickel-cadmium batteries that can deliver high intensity light for an hour and can be recharged overnight. The Opthalmoscope Powerpack consists of eight batteries in three containers affixed to a webbed belt, and a novel on-off switch equipped with a spring-loaded plexiglass 'flapper.' The belt pack is worn underneath the surgical gown and the flapper permits the doctor to activate the switch by elbow pressure. Lewis built five units and they have been in service at St. Luke's Hospital for a year. Used for routine examinations as well as for surgery, they have demonstrated excellent reliability.

Source record↗

Method of Conjugate Radii for Solving Linear and Nonlinear Systems

This paper describes a method to solve a system of N linear equations in N steps. A quadratic form is developed involving the sum of the squares of the residuals of the equations. Equating the quadratic form to a constant yields a surface which is an ellipsoid. For different constants, a family of similar ellipsoids can be generated. Starting at an arbitrary point an orthogonal basis is constructed and the center of the family of similar ellipsoids is found in this basis by a sequence of projections. The coordinates of the center in this basis are the solution of linear system of equations. A quadratic form in N variables requires N projections. That is, the current method is an exact method. It is shown that the sequence of projections is equivalent to a special case of the Gram-Schmidt orthogonalization process. The current method enjoys an advantage not shared by the classic Method of Conjugate Gradients. The current method can be extended to nonlinear systems without modification. For nonlinear equations the Method of Conjugate Gradients has to be augmented with a line-search procedure. Results for linear and nonlinear problems are presented.

Nachtsheim, Philip R.↗

Eye Surgery Light

During eye surgery, the surgeon uses an illuminating instrument called an opthalmoscope for close examination of the retina or the interior of the eye. Ordinarily, electric power for the head-mounted light is supplied through a cord from an overhead swivel arm or a floor pedestal. Within limits of cord length and swivel arm movement, the surgeon has considerable freedom of motion. But when more than one opthalmoscope is involved, tangling and interference of the power cords becomes a problem. St. Luke's Hospital, Cleveland, Ohio asked Lewis Research Center for assistance in finding a solution. Lewis responded with a battery-powered system that totally frees the surgeon of attached cords and swivels. Borrowing from space technology, Lewis used small, lightweight nickel-cadmium batteries that can deliver high intensity light for an hour and can be recharged overnight. The Opthalmoscope Powerpack consists of eight batteries in three containers affixed to a webbed belt, and a novel on-off switch equipped with a springloaded plexiglass "flapper." The belt pack is worn underneath the surgical gown and the flapper permits the doctor to activate the switch by elbow pressure. Lewis built five units and they have been in service at St. Luke's Hospital for a year. Used for routine examinations as well as for surgery, they have demonstrated excellent reliability.

Source record↗

Space Shuttle Orbiter Atlantis Liquid Oxygen Pre-Valve Detent Roller Cracking Investigation

During routine inspections of the Space Shuttle s Main Propulsion System Liquid Oxygen (LO2) pre-valve, the mechanism provided to maintain the valve in the open position was found cracked. The mechanism is a Vespel roller held against the valve visor by a stack of Belleville springs. The roller has been found cracked 3 times. All three instances were in the same valve in the same location. There are 6 pre-valves on each orbiter, and only one has exhibited this problem. Every-flight inspections were instituted and the rollers were found to be cracked after only one flight. Engineers at Marshall Space Flight Center, Johnson Space Center, and Kennedy Space Center worked together to determine a solution. There were several possible contributors to the failure: a misaligned visor, an out-of-specification edge with a sharp radius, an out-of-specification tolerance stack up of a Belleville spring stack that caused un-predicted loads on the Vespel SP-21 roller, and a dimple machined into the side of the roller to indicate LO2 compatibility that created a stress riser. The detent assembly was removed and replaced with parts that were on the low side of the tolerance stack up to eliminate the potential for high loads on the detent roller. After one flight, the roller was inspected and showed fewer signs of wear and no cracks.

Holleman, Elizabeth↗

Space Shuttle Orbiter Atlantis Liquid Oxygen Prevalve Detent Roller Cracking Investigation

During routine inspections of the Space Shuttle's Main Propulsion System (MPS) Liquid Oxygen (LO2) pre-valve, the mechanism provided to maintain the valve in the open position was found cracked. The mechanism is a Vespel roller held against the valve visor by a stack of Belleville springs. The roller has been found cracked 3 times. All three instances were in the same valve in the same location. There are 6 pre-valves on each orbiter, and only one has exhibited this problem. Every-flight inspections were instituted and the rollers were found to be cracked after only one flight. Engineers at Marshall Space Flight Center, Johnson Space Center and Kennedy Space Center worked together to determine a solution. There were several possible contributors to the failure: a mis-aligned visor, an out of specification edge with a sharp radius, an out of specification tolerance stack up of a Belleville spring stack that caused un-predicted loads on the Vespel SP-21 roller, and a dimple machined into the side of the roller to indicate LO2 compatibility that created a stress riser. The detent assembly was removed and replaced with parts that were on the low-side of the tolerance stack up to eliminate the potential for high loads on the detent roller. After one flight, the roller was inspected and showed fewer signs of wear and no cracks.

Holleman, Elizabeth↗