Replacing Transmission Infrastructure with Solar and Energy Storage Systems: An Islanded Microgrid Case Study.
Abstract not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
This analysis was conducted under the first round of the Solar Energy Innovation Network (SEIN), a program led by the National Renewable Energy Laboratory (NREL) that assembles diverse teams of stakeholders to research solutions to real-world challenges associated with solar energy adoption. This analysis supported the efforts of the Montana Solar Powered Community Transportation Initiative, a team consisting of the Montana Renewable Energy Association, Montana Energy Office at the Department of Environmental Quality, City of Missoula, City of Bozeman, City of Whitefish, Climate Smart Missoula, and Yellowstone-Teton Clean Cities. The team is investigating the synergies between solar generation and electric vehicle (EV) charging, including the potential opportunities and challenges related to co-locating solar energy and charging infrastructure to reduce costs and enhance co-benefits of the electrification of transportation. The City of Missoula's transit agency has purchased six electric buses. This analysis supports the team's efforts to understand the potential costs and specific options for using solar and storage to reduce EV bus charging costs.
Potential for rooftop solar in Florida is massive (47% of retail sales, 3rd overall nationally), yet adoption lags (12th nationally). A 2018 Florida Public Service Commission ruling authorizing solar third-party ownership (leasing) has substantially increased attention on distributed solar in the state. The city of Orlando has committed to a 100% clean-energy target by 2050 and deployment of solar and storage are expected to contribute significantly to reaching the goal. Deployment of customer-adopted solar, unlike utility-procured solar, is uncertain, but known to be spatially correlated with demographic factors and existing adoption. We develop a new method to adapt NREL's dGen model in order to represent building-level agents in adoption forecasts for the Orlando Utility Commission (OUC) service territory. Using the agent-based model we develop projections of solar adoption, subject to scenarios varying future solar costs and valuation, and aggregate adoption predictions by OUC distribution feeder. We find substantial spatial heterogeneity in the projected level of adoption by OUC distribution feeder. For instance, 25% of all projected adoption through 2050 would be concentrated on just 5% of feeders and 88% of projected adoption on 50% of feeders. Because of the uncertainty in adoption, bottoms-up solar adoption forecasting methods at the household-level are integral to long-term resource planning by anticipating system needs as customers increasingly adopt distributed solar, storage, electric vehicles, and other distributed energy resources.
Solar and other renewable energy driven gas-solid thermochemical energy storage (TCES) technology is a promising solution for the next generation energy storage systems due to its high operating temperature, efficient energy conversion, ultra-long storage duration, and potential high energy density. Experimental and theoretical studies suggest that the respective gravimetric and volumetric TCES energy storage densities vary from 200 to 3000 kJ kg –1 and 1–3 GJ m –3 . Solar radiation or heat generated from electric furnaces powered by renewable electricity can be stored in the form of chemical energy through endothermic reactions, while the stored chemical energy can be converted to thermal energy via an exothermic reaction when needed. The design of highly effective reactors requires a deep understanding of materials, thermodynamics, chemical kinetics, and transport phenomena. At time of writing, TCES reactors are yet to be deployed at commercially relevant scales, leaving a substantial gap between development efforts and commercial feasibility. Therefore, this review aims to examine the state-of-the-art design and performance of particle-based TCES reactors with different reactive materials. Fundamentals related to TCES reactive materials, reaction conditions, thermodynamics and kinetics, and transport phenomena are reviewed in detail to provide a comprehensive understanding of the reactor design and operation. Five major types of TCES reactors have been comprehensively reviewed and compared, including fixed, moving, rotary, fluidized, and entrained bed reactors. Most reported prototype reactors in the literature operate at lab scale with thermal inputs below 40 kW, and scaled TCES reactors (e.g., at megawatt level) are yet to be demonstrated. The nominal reactor operating temperatures range from 300 to 1500 °C, depending on the selected chemistry, reactive material, and heat sources. To evaluate their designs, the reactors are assessed in aspects of performance, cost, and durability. Discrepancies in performance indicators of energy storage density, extent of reaction, and various energy efficiencies are highlighted. The scale-up of reactors and power block integration, which hold the key to the successful commercialization of TCES systems, are critically analyzed. Furthermore, advanced materials (both reactive materials and ceramic reactor housing materials), effective particle flow control, advanced modeling tools, and novel system design may bring significant improvement to the energy efficiency, storage density and cost competitiveness of particle-based TCES reactors.
The economic potential of a behind-the-meter (BTM) PV-battery system depends greatly on how the battery is dispatched. Different utility rates, system sizes, generation and load profiles can all require different dispatch strategies. This paper presents price signals dispatch, a new algorithm for automated economic dispatch of BTM PV-battery systems, which utilizes 24-hour PV and load forecasts, degradation data, and utility rates. The algorithm is integrated with the System Advisor Model (SAM) tool and is tested with a nonlinear generic electrochemical battery model. Price signals dispatch outperforms SAM's existing algorithms in cases requiring a balance between demand charge management and energy arbitrage, and in cases where battery degradation imposes a significant cost.
This report benchmarks U.S. solar photovoltaic (PV) system installed costs as of the first quarter of 2020 (Q1 2020). We use a bottom-up method, accounting for all system and project-development costs incurred during the installation to model the costs for residential (with and without storage), commercial (with and without storage), and utility-scale systems (with and without storage). We also incorporate other system characteristics and performance factors, as well as ongoing costs, to benchmark LCOE for PV-standalone systems, and LCOSS for solar+storage.
Oxide particles can serve as both the heat transfer and thermal energy storage (TES) media for next-generation concentrating solar power (CSP) plants where high-temperature TES enables dispatchable electricity from efficient power cycles with firing temperatures above 600 °C. Transferring heat to flowing particles at such high temperatures in a MW-scale central tower receiver remains a challenge for the CSP community. For indirect receivers with external walls to contain the particles, maintaining wall temperatures below the limits of structural metal alloys requires high heat transfer coefficients between the wall and the moving particle stream. Bubbling fluidization of downward-flowing particles can sustain high bed-wall heat transfer coefficients (> 1000 W m -2 K -1 ). Using experimentally calibrated correlations for bed-wall heat transfer and vertical particle dispersion, this study implements an axially discretized zonal model of a counterflow fluidized bed receiver to explore how bubbling fluidization may enable indirect cavity particle receivers. High bed-wall heat transfer coefficients support solar fluxes on angled cavity walls > 200 kW m -2 at peak aperture fluxes of 980 kW m -2 while maintaining external wall temperatures < 950 °C. Lateral particle dispersion enables hotter particles near the receiver leading edge to mix with cooler particles further from the leading edge to lower maximum external wall temperatures. Parametric studies identify how mass fluxes, particle dispersion, and solar concentrations impact indirect receiver thermal efficiency and uniformity for a CSP plant. These studies provide a basis for the design of indirect fluidized-bed cavity receivers that can maintain particle outlet temperatures for TES above 750 °C.
Concentrating solar power (CSP) plants convert energy from sunlight into electricity. Generally, a heliostat field is used to reflect sunlight and concentrate it onto a receiver, which heats the receiver and/or the media flowing through it. A flow loop transports the media through the system to a heat exchanger before returning the media back to the receiver to be reheated. The heat extracted by the heat exchanger is then converted into electricity using a conventional heat engine.
Veritel Energy LLC has successfully demonstrated the feasibility of its innovative adaptive solar energy and power storage platform designed for multimetered properties in Phase I of its DOE SBIR grant. The project centered around the development and initial deployment of proprietary hardware and software system that manages and distributes site-generated renewable energy to multiple tenants efficiently. This system integrates seamlessly with existing building infrastructure and utility systems, making it a viable solution for aging multifamily properties often located in at-risk communities. The pilot system was installed in a multifamily building with a single master-meter, and functioned as a pilot to demonstrate a scalable model for renewable energy system adoption across similar properties. This installation not only showed potential for significant reductions in greenhouse gas emissions but also improved the economic viability of renewable installations by allowing property owners to recoup investments through increased energy savings and tenant billing. The Phase I project set the groundwork for further enhancements and testing in Phase II which will aim to apply the technology to projects with dozens of sub-meters, further contributing to the decarbonization of the built environment.
Buildings with solar photovoltaic (PV) generation and a stationary battery energy storage system (BESS) may self-sustain an uninterrupted full-level electricity supply during power outages. The duration of off-grid operation is dependent on the time of the power fault and the capabilities of the home energy management system (HEMS). In this paper, building resilience is quantified by analyzing the self-sustainment duration for all possible power outages throughout an entire year. An evaluation method is proposed and exercised on a reference house in California climate zone 9 for which the detailed electricity usage is simulated using the EnergyPlus software. The influence of factors such as energy use behavioral patterns, energy storage capacity from the BESS, and an electric vehicle (EV) battery on the building resilience is evaluated. Varying combinations of energy storage and controllable loads are studied for optimally improved resilience based on user preferences. It is shown that for the target home and region with a solar PV system of 7.2 kW, a BESS with a capacity of 11 kWh, and an EV with a battery of 80 kWh permanently connected to the home, off-grid self-sustained full operation is guaranteed for at least 72 h.
A large entropy of reduction is crucial in achieving materials capable of high-efficiency solar thermochemical hydrogen (STCH) production through two-step thermochemical water splitting cycles. We have recently demonstrated that the onsite electronic entropy of reduction attains an extreme value of 4.26 kB at 1500 K in Ce 4+ → Ce 3+ redox reactions, which explains the high performance and uniqueness of CeO 2 as an archetypal STCH material. However, ceria requires high temperatures (T > 1500 °C) to achieve a reasonable reduction extent because of its large reduction enthalpy, which is a major obstacle in practical applications. Therefore, new materials with a large entropy of reduction and lower reduction enthalpy are required. Here, we perform a systematic screening to search for Ce 4+ -based oxides which possess thermodynamics superior to CeO 2 for STCH production. We first search the Inorganic Crystal Structure Database (ICSD) and literature for Ce 4+ -based oxides and subsequently use density functional theory to compute their reduction enthalpies (i.e., oxygen vacancy formation energies). Here, we find that CeTi 2 O 6 with the brannerite structure is the most promising candidate for STCH because it possesses three essential characteristics of an STCH material: (i) a smaller reduction enthalpy compared to ceria yet large enough to split water, (ii) a high thermal stability, as reported experimentally, and (iii) a large entropy of reduction associated with Ce 4+ → Ce 3+ redox. Our proposed design strategy suggests that further exploration of Ce 4+ oxides for STCH production is warranted.
The Government of India has a target of deploying 175 GW from renewable energy by 2022 and 40% of electricity capacity from renewable energy by 2030 and has indicated that ambitions for 2030 could be higher. Rapid changes in technology costs and performance could drive further deployment of wind and solar capacity beyond these policy targets. Increased deployment of variable renewable energy (VRE) raises new questions for power system planning regarding the optimal siting of generation capacity, trade-offs between generation and transmission infrastructure, and system flexibility needs. This study aims to evaluate least-cost pathways for India's electric power system over the period 2017-2047. Uniquely, this work considers an expanded planning horizon and range of scenarios not previously analyzed in national planning studies in India. The data collection and model design processes undertaken for this study provides a framework for recurring planning studies. This study finds anticipated changes in electricity demand and component costs can drive a significant shift in India's future electricity supply and how this system will be operated. In the Base scenario, the share of generation from VRE reaches 54% by 2047. Reducing the capital cost of wind has a larger impact on VRE penetration than reducing the capital cost of solar PV or battery storage. In the lowest wind cost scenario (40% capital cost decline by 2047 relative to the Base scenario), the penetration of VRE in the generation mix reaches 722%, exceeding the penetration levels achieved when the cost of battery storage or solar PV are reduced by an even greater 50%. In a future system with high penetrations of RE, capacity additions are driven by the coincidence of demand and RE generation rather than peak demand alone. This study finds the system could have surplus capacity during the peak demand months of July–September because this period corresponds to periods with high wind speeds and more wind generation available to meet peak demand. By contrast, new capacity is needed to meet demand during moderate demand months of October–November when output from wind plants falls more than 75% nationally compared to the previous two months. Finally, the success for gas for electricity production may depend on cost competitiveness rather than fuel availability. Increasing the amount of gas available for electricity production had no significant impact on the capacity or generation mix by 2047, as determined from a scenario that significantly increases fuel availability throughout the planning horizon. In fact, over 80% of new gas fuel available for the power sector remains unused. This suggests the high cost of gas plant operations relative to other technologies may constrain the expansion of gas generation in India more than fuel availability.
This report is the final in NREL's Storage Futures Study, a multiyear research project that explored the role and impact of energy storage in the evolution and operation of the U.S. power sector. The SFS examined the potential impact of energy storage technology advancement on the deployment of utility-scale storage and the adoption of distributed storage, and the implications for future power system infrastructure investment and operations. The research findings and supporting data were published across a series of six reports, culminating in this final, seventh publication that draws upon findings from across the study, previous work, and additional analysis to identify eight key learnings about the future of energy storage and its impact on the power system. The key learnings can help policymakers, technology developers, and grid operators prepare for the coming way of energy storage deployment.
The Storage Futures Study (SFS) is a multiyear research project that explored the role and impact of energy storage in the evolution and operation of the U.S. power sector. The SFS examined the potential impact of energy storage technology advancement on the deployment of utility-scale storage and the adoption of distributed storage, and the implications for future power system infrastructure investment and operations. The research findings and supporting data were published across a series of six reports, culminating in the final, seventh publication that draws upon findings from across the study, previous work, and additional analysis to identify eight key learnings about the coming decades. This presentation is from an NREL webinar to discuss the eight key learnings.
To assess the economic value of batteries in hybrid PV-battery systems, one must create a dispatch profile for the battery. Many analyses of battery value assume perfect forecasts of PV generation and load, determining an upper limit on the value of the battery. Prior work that accounts for forecast uncertainty often does so in the context of a single dispatch algorithm, which does not provide a baseline for comparison. Furthermore, when multiple dispatch algorithms are assessed with uncertainty, the benefits considered are for diesel generation in a microgrid, not retail rate savings. This work addresses the gaps in the literature by comparing the performance of both heuristic and optimal dispatch algorithms for retail rate savings under forecast uncertainty, and provides comparisons of the robustness of these algorithms and their associated estimates of economic value. We find that using a perfect forecast can overestimate the value of hybrid PV-battery systems between 1% and 8% compared to the reality of using a day-ahead forecast, depending on the dispatch algorithm used. Thus, accounting for forecast uncertainty in system design and analysis will significantly improve the accuracy of modeled system values.
The thermal energy storage (TES) system is a critical component in concentrated solar power (CSP) plants that increases the plant's capacity factor and economic competitiveness by reducing the levelized cost of energy (LCOE) while simultaneously increasing the value of the delivered energy. Failures including molten-salt leaks and diverse localized cracking after several months to a few years of operation have been reported in hot tanks for CSP plants operating around the world. A model of a molten salt thermal energy storage tank was developed and validated to analyze the impact of different tank design features on the temperature and stress distributions as a function of typical plant operation conditions. Design features included the floor plate thicknesses, friction coefficients between the tank floor and the foundation, and the sparger ring location. Maximum stresses in the tank floor frequently surpassed the yield point of the material during operation, leading to a detriment of the tank's lifetime. Recommendations on design features to improve the reliability of new molten salt tanks for CSP plants are provided.
In this project, we developed a techno-economic analysis (TEA) model that can be used to evaluate the viability of a proposed Geological Thermal Energy Storage (GeoTES) design. This MATLAB-based model integrates distinct subsystem models for the reservoir, wells, power cycle, and solar field to capture their distinct characteristics. It applies this approach in simulating GeoTES storage and dispatch operations for durations ranging from hourly to seasonal. Using cases studies based on GeoTES designs provided by industry partners - Premier Resource Management (PRM) and EarthBridge Energy - we validated the TEA model estimations of system performance and costs (such as thermal and electrical power/energy inflow and outflow, capital costs, and levelized costs of energy and storage) for both concentrating solar thermal (CST) and Carnot Battery (CB) pairings with GeoTES (CST-GeoTES and CB-GeoTES). For the CST-GeoTES case, the model was validated against the proposed system designed by PRM. It showed good agreement with PRM's estimations when well and pump costs derived from PRM's estimations were used. When GETEM-based costs were used, there was a slight overprediction due to GETEM's project/site agnostic assumption of these costs. From a sensitivity analysis perspective, the levelized cost of electricity (LCOE) of the CST-GeoTES case was most sensitive to well flow rate and the charging temperature. An optimal design scenario resulted in an LCOE of 0.11 $\$$/kWhe. CST-GeoTES can also provide a source of heat to meet seasonal demands. With 12-hour and 24-hour levelized cost of heat (LCOH) of 0.018 $\$$/kWhth and 0.022 $\$$/kWhth, respectively, CST-GeoTES could be competitive in the California market with an average industrial price of natural gas in California between 0.041-0.047 $\$$/kWhth. The levelized cost of storage (LCOS) for CST-GeoTES depends on the energy storage duration. Although the LCOS is relatively higher for shorter durations (e.g., ~0.50 $\$$/kWhe for 1 hour of storage), it is an order of magnitude lower (0.06 $\$$/kWhe) for longer storage durations and competitive with lithium-ion batteries (beyond 12 hours of storage) and molten-salt thermal energy storage (beyond 32 hours). Energy. Three options were explored and applied to the EarthBridge case study: (1) A Carnot Battery design using R125 working fluid with both hot and cold storage; (2) A Carnot Battery design using R125 working fluid with only hot storage; (3) A Carnot Battery using a commercially available heat pump with carbon dioxide (CO2) working fluid and hot storage only. The CB-GeoTES with cold storage only had a slight (round-trip) efficiency advantage over the system without (43.4% vs. 42.8%). This is because the cold storage is limited by the freezing point of water, so the cold storage is not much colder than the environment. The system using commercially available technologies was the least efficient - partly because different cycles were used in the heat pump (CO2) and heat engine (binary cycle) which leads to some inefficiencies. Using the commercially available design, the levelized cost of energy (LCOS) from the model (0.10 $\$$/kWhe) was higher than that estimated by EarthBridge (0.068 $\$$/kWhe). This is because of the low round-trip (38.7%) efficiency of the commercially available design. Sensitivity analysis reveals that the model is most sensitive to electricity price. Including electricity price in the TEA for CB-GeoTES leads to an increase in LCOS from the base value to 0.25 $\$$/kWhe. To determine storage sites suitable for GeoTES, we gathered and analyzed geological, petrophysical, and geophysical data of oil and gas reservoir and aquifers in California and Texas. We down-selected possible sites based on cut-off values for site characteristics (e.g., reservoir temperature, formation thickness, permeability, porosity, depth, and brine salinity) and preliminary costs. Using this approach, the Carrizo-Wilcox, Yegua-Jackson, and Dockum brackish aquifers in Texas were identified as having the highest suitability. Similarly, in the central California region, the White Wolf, Belridge South Tulare, and Belridge South Reef Ridge were the most suitable. Going further, we assessed the storage potential in the selected sites. To do this we developed distributions of reservoir characteristic data and applied a Monte Carlo-based analysis to account for intrinsic uncertainty in the acquired data. The analysis revealed that the Carrizo-Wilcox aquifer had the highest storage potential with a mean capacity of 554 TWhth (i.e., 63 TWhe). The estimated capacity serves as an upper limit of storage potential given that not all fields in the basin will be developed. We participated in multiple outreach activities including conference presentations, panel session discussions, and the facilitation of a GeoTES workshop at the NREL Golden campus.
The LA100 Equity Strategies project integrates community guidance with robust research, modeling, and analysis to identify strategy options that can increase equitable outcomes in Los Angeles' clean energy transition. This chapter focuses on community solar as a means to provide equitable access to local solar and storage benefits in Los Angeles. Specifically, NREL identified potential community solar sites that could host 30 kilowatts (kW)1 of solar or more and evaluated economic and equity metrics under various program design options. Analysis included a Baseline scenario (business-as-usual) and an Equity scenario, which modeled program enhancements to increase access and benefits to low-income customers. Both scenarios modeled the economics of solar and storage under the LADWP Feed-in Tariff (FiT) program (LADWP 2023b) and the LADWP Feed-in-Tariff Plus Pilot program (LADWP 2023d) compared to a community solar financial model. This research was guided by input from the community engagement process, and associated equity strategies are presented in alignment with that guidance.