Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “slit”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Solar Coronal Structure Study

The subject of this investigation is the study the physics of the solar corona through the analysis of the EUV and UV data produced by two flights (12 May 1992 and 25 April 1994) of the Lockheed Solar Plasma Diagnostics Experiment (SPDE) sounding rocket payload, in combination with Yohkoh and groundbased data. These joint datasets are useful for understanding the physical state of the solar atmosphere from the photosphere to the corona at the time of the rocket flights. Each rocket flight produced both spectral and imaging data. Highlights of this initial year of the contract included compilation, scaling and co-alignment of image sets, substantial progress on the Bright Point study, initial work on the Active Region and Large Scale Structure studies, DRSC slit-aspect determination work and calibration activities. One paper was presented at the 1997 Annual Meeting of the AAS/SPD in Bozeman, Montana. An initial set of calibrated spectra were placed into the public domain via the World Wide Web. Three Quarterly Progress Reports have been submitted; progress for the fourth quarter of the contract is summarized in this Final Contract Report. The intent of the investigation is to compare the physics of small- and medium-scale structure with that of large-scale structures with weak fields. A study has been identified in each size domain. The calibration of the rocket data forms an important element of the work. Of equal importance is the slit-aspect solution, which determines the correspondence between locations along the spectrograph slit and points on the solar disk.

Bruner, Marilyn E.↗

Convex Diffraction Grating Imaging Spectrometer

A 1:1 Offner mirror system for imaging off-axis objects is modified by replacing a concave spherical primary mirror that is concentric with a convex secondary mirror with two concave spherical mirrors M1 and M2 of the same or different radii positioned with their respective distances d1 and d2 from a concentric convex spherical diffraction grating having its grooves parallel to the entrance slit of the spectrometer which replaces the convex secondary mirror. By adjusting their distances d1 and d2 and their respective angles of reflection alpha and beta, defined as the respective angles between their incident and reflected rays, all aberrations are corrected without the need to increase the spectrometer size for a given entrance slit size to reduce astigmatism, thus allowing the imaging spectrometer volume to be less for a given application than would be possible with conventional imaging spectrometers and still give excellent spatial and spectral imaging of the slit image spectra over the focal plane.

Chrisp, Michael P.↗

Spectral Emittance and Reflectance Measurements at the Jet Propulsion Laboratory

In late 1959 a spectrophotometer laboratory was established at JPL to be used as a support for temperature-control programs. The immediate task was spectroradiometric measurements of light sources to be used in a simulated-deep-space environment chamber. It was also necessary to have permanent provisions for measuring reflectances of surfaces for the calculation of solar absorptance alpha, and thermal emittance epsilon. The spectral distribution of an unknown source, in this case a Ventarc carbon-arc lamp, was derived from the ratio of detector outputs (with monochromatic light) of the arc lamp and a tungsten lamp, and the spectral intensity of the tungsten lamp. The tungsten lamp is a ribbonfilament lamp calibrated from 0.25 to 2.6 microns. A recording of pen deflection (linearly proportional to detector output) of each source over the visible and near infrared range is made with all parameters (slit width, amplifier gain, and source focusing) identical; then the ratios are computed at discrete wavelengths from these recordings. Because the spectral intensities of the tungsten lamp and a solar simulator are very different in most of the range, an adjustable slit is placed immediately in front of the detector to obtain comparable pen deflections for the two sources. This slit is set by means of a feeler gage, and the attenuation coefficient is evaluated by a transmission measurement.

Maclay, James E.↗

Temperature Variations from HST Imagery and Spectroscopy of NGC 7009

We present new HST/WFPC2 imagery and STIS long-slit spectroscopy of the planetary nebula NGC 7009. The primary goal was to obtain high spatial resolution of the intrinsic line ratio [O III] 4364/5008 and thereby evaluate the electron temperature (Te) and the mean-square Te variation (t(sup 2, sub A)) across the nebula. The observations here do not address Te fluctuation along the line of sight. The WFPC2 Te map is rather uniform; almost all values are between 9000 - 11,000 K, with the higher Te's closely coinciding with the inner He(++)-zone. The results indicate very small values - certainly less than 0.01 - for t(sup 2, sub A) throughout. Our STIS data allow an even more direct determination of Te and t(sup 2, sub A), albeit for a much smaller area than with WFPC2. We present results from binning the data along the slit into tiles that are 0.5 in square (matching the slit width). The average [O III] temperature using 45 tiles (excluding the central star and STIS fiducial bars) is 10,146 K; t(sup 2, sub A) is 0.0036. Although we have measured t(sup 2, sub A) in only 2-dimensions, we conclude that temperature fluctuations alone are unlikely to explain for NGC 7009 the large discrepancy between heavy element abundances inferred from emission lines that are collisionally excited compared with those that are due to recombination lines.

Rubin, R. H.↗

Small Deflection Energy Analyzer for Energy and Angular Distributions

The development of the Small Deflection Energy Analyzer (SDEA) charged-particle spectrometer for energy and angle distributions responds to a longstanding need to measure the wind velocity vector in Earth s thermosphere, and to obtain the ion-drift vector in the ionosphere. The air and ions above 120 km are endowed with bulk velocities and temperatures just like air near the ground, but with separate spatial and temporal variations. It is important to understand these not only for study of the physics and chemistry of the Sun-Earth connection, but also for spacecraft orbit predictions, and communications through the ionosphere. The SDEA consists of a pair of parallel conducting plates separated by a small distance, with an entrance slit on one end, and an exit slit on the other. A voltage applied to these plates develops an electric field between the plates, and this field deflects ions passing through it. If an ion has too little energy, it will strike one of the plates. If it has too much, it will strike the back wall. An ion with the amount of energy being searched for will have its trajectory bent just enough to exit the back slit. The SDEA units are compact, rectangular, and operate with low voltages. The units can be built up into small arrays. These arrays could be used either to widen the field of view or to sharpen an existing one. This approach can also be used to obtain angular distributions in two planes simultaneously, thus cutting down the ion source power requirements in half. This geometry has enabled a new mass-spectrometer concept that can provide miniaturized mass spectrometers for use in industrial plants, air-pollution monitoring, and noxious-gas detection.

Herrero, Federico A.↗

Apparatus and method for a light direction sensor

The present invention provides a light direction sensor for determining the direction of a light source. The system includes an image sensor; a spacer attached to the image sensor, and a pattern mask attached to said spacer. The pattern mask has a slit pattern that as light passes through the slit pattern it casts a diffraction pattern onto the image sensor. The method operates by receiving a beam of light onto a patterned mask, wherein the patterned mask as a plurality of a slit segments. Then, diffusing the beam of light onto an image sensor and determining the direction of the light source.

Leviton, Douglas B.↗

Constraining the Absolute Orientation of eta Carinae's Binary Orbit: A 3-D Dynamical Model for the Broad [Fe III] Emission

We present a three-dimensional (3-D) dynamical model for the broad [Fe III] emission observed in Eta Carinae using the Hubble Space Telescope/Space Telescope Imaging Spectrograph (HST/STIS). This model is based on full 3-D Smoothed Particle Hydrodynamics (SPH) simulations of Eta Car's binary colliding winds. Radiative transfer codes are used to generate synthetic spectro-images of [Fe III] emission line structures at various observed orbital phases and STIS slit position angles (PAs). Through a parameter study that varies the orbital inclination i, the PA(theta) that the orbital plane projection of the line-of-sight makes with the apastron side of the semi-major axis, and the PA on the sky of the orbital axis, we are able, for the first time, to tightly constrain the absolute 3-D orientation of the binary orbit. To simultaneously reproduce the blue-shifted emission arcs observed at orbital phase 0.976, STIS slit PA = +38deg, and the temporal variations in emission seen at negative slit PAs, the binary needs to have an i approx. = 130deg to 145deg, Theta approx. = -15deg to +30deg, and an orbital axis projected on the sky at a P A approx. = 302deg to 327deg east of north. This represents a system with an orbital axis that is closely aligned with the inferred polar axis of the Homunculus nebula, in 3-D. The companion star, Eta(sub B), thus orbits clockwise on the sky and is on the observer's side of the system at apastron. This orientation has important implications for theories for the formation of the Homunculus and helps lay the groundwork for orbital modeling to determine the stellar masses.

Madura, T. I.↗

GESE: A Small UV Space Telescope to Conduct a Large Spectroscopic Survey of Z-1 Galaxies

One of the key goals of NASA's astrophysics program is to answer the question: How did galaxies evolve into the spirals and elliptical galaxies that we see today? We describe a space mission concept called Galaxy Evolution Spectroscopic Explorer (GESE) to address this question by making a large spectroscopic survey of galaxies at a redshift, z is approximately 1 (look-back time of approximately 8 billion years). GESE is a 1.5-meter space telescope with an ultraviolet (UV) multi-object slit spectrograph that can obtain spectra of hundreds of galaxies per exposure. The spectrograph covers the spectral range, 0.2-0.4 micrometers at a spectral resolving power, R approximately 500. This observed spectral range corresponds to 0.1-0.2 micrometers as emitted by a galaxy at a redshift, z=1. The mission concept takes advantage of two new technological advances: (1) light-weighted, wide-field telescope mirrors, and (2) the Next- Generation MicroShutter Array (NG-MSA) to be used as a slit generator in the multi-object slit spectrograph.

galaxy evolution↗

Galaxy Evolution Spectroscopic Explorer: Scientific Rationale

GESE is a mission concept consisting of a 1.5-m space telescope and UV multi-object slit spectrograph designed to help understand galaxy evolution in a critical era in the history of the universe, where the rate of star-formation stopped increasing and started to decline. To isolate and identify the various processes driving the evolution of these galaxies, GESE will obtain rest-frame far-UV spectra of 100,000 galaxies at redshifts, z approximately 1-2. To obtain such a large number of spectra, multiplexing over a wide field is an absolute necessity. A slit device such as a digital micro-mirror device (DMD) or a micro-shutter array (MSA) enables spectroscopy of a hundred or more sources in a single exposure while eliminating overlapping spectra of other sources and blocking unwanted background like zodiacal light. We find that a 1.5-m space telescope with a MSA slit device combined with a custom orbit enabling long, uninterrupted exposures (approximately 10 hr) are optimal for this spectroscopic survey. GESE will not be operating alone in this endeavor. Together with x-ray telescopes and optical/near-IR telescopes like Subaru/Prime Focus Spectrograph, GESE will detect "feedback" from young massive stars and massive black holes (AGN's), and other drivers of galaxy evolution.

digital micro-mirror device (DMD)↗

Modeling the Scattering Polarization of the Hydrogen Ly-alpha Line Observed by CLASP in a Filament Channel

The 400 arcsec spectrograph slit of CLASP crossed predominantly quiet regions of the solar chromosphere, from the limb towards the solar disk center. Interestingly, in the CLASP slit-jaw images and in the SDO images of the He I line at 304 A, we can identify a filament channel (FC) extending over more than 60 arcsec crossing the spectrograph slit. In order to interpret the peculiar spatial variation of the Q/1 and U/1 signals observed by CLASP in the hydrogen Ly-alpha line (1216 A) and in the Si Ill line (1206 A) in such a filament channel, it is necessary to perform multi-dimensional radiative transfer modeling. In this contribution, we show the first results of the two-dimensional calculations we are carrying out in given filament models, with the aim of determining the filament thermal and magnetic structure by comparing the theoretical and the observed polarization signals.

CLASP↗

Automated Fiber Placement Manufactured Composites for Science Applications

Science instruments with large collecting areas that maintain dimensional stability, such as James Webb Space Telescope and Wide Field Space Telescope, help achieve next generation science advancements. Composite materials often used for science applications include high modulus fibers in cyanate ester matrices to result in dimensionally stable structures with low contamination. Hand lay-up fabrication is the most common approach for science instrument structures. Automated Fiber Placement (AFP) using intermediate modulus fibers is commonplace in aircraft production reducing manufacturing time and increasing quality and consistency. AFP manufacturing for future large science instruments can similarly reduce costs and increase reliability. However, high modulus fibers are more prone to damage than intermediate modulus fibers. This study investigates the manufacturing viability of M55J/RS3C (Tencate) slit tape material using AFP processing. Tencate provides slit tape materials. NASA Langley Research Center (LaRC) manufactured hand layup and AFP lay-up laminates under room temperature for initial trials, Marshall Space Flight Center (MSFC) manufactured AFP laminates under room temperature and elevated temperature conditions to evaluate processing affects. Goddard Space Flight Center (GSFC) tests and evaluates tension and Coefficient of Thermal Expansion (CTE) properties by hand lay-up and AFP slit tape automated manufacturing for large science applications. These results show processing material warm reduces process induced fiber fracture; leading to stiffness and CTE properties consistent with hand lay-up, while observing a slight degradation in tensile strength.

Segal, Kenneth N.↗

WFIRST CGI: Prism and Polarizer Characterization Modes

As part of its technology demonstration, the WFIRST coronagraph instrument (CGI) will demonstrate point source spectroscopy and polarization measurements of disks. The specific implementation of spectroscopy is a zero-deviation Amici prism and slit to be placed on the planet after high contrast has been achieved by CGI. The polarization optics are a set of Wollaston prisms so that orthogonal polarization states can be measured simultaneously. The CGI spectral characterization mode, being designed and built and Goddard Space Flight Center (GSFC), has a spectral resolution of R50 and is designed to accommodate a 15% bandpass spanning 610-785nm. In order to recover Stokes information, there are two sets of Wollaston prisms clocked 45 degrees with respect to one another with each measurement taken in series. The Wollaston design and optical elements are a contribution by the Japanese Aerospace Exploration Agency, with final alignment and testing being done at GSFC. The spectroscopy mode is designed to target Methane absorption features around 730nm, keeping the spectral resolution as low as possible to improve the signal-to-noise ratio and hence reduce detection time. We highlight the requirements for these modes and address the challenge of on-orbit spectral calibration for a deployable slit in the presence of pointing drifts. Of unique interest is how the observatory error budget couples into good stellar spectrum calibration and subsequent speckle subtraction. We also provide further detail on the optomechanical design, its stability based on thermal and structural predictions, modeled performance, and operations concept. These performance metrics are simulated to demonstrate how a slit located at an arbitrary field point is homed onto the planet and converted to a calibrated spectrum.

Tyler D Groff↗

Spectral Measurement Errors due to CCD Serial Pixel-to-Pixel Readout Interference in the Ocean Color Instrument of the NASA PACE Mission

The Ocean Color Instrument on NASA’s PACE mission is a hyperspectral imager with a spatial resolution of 1km x 1km and spectral resolution of 5nm in 2.5nm steps over 320-890nm. The detection system is based on two Charge-Coupled Devices (CCDs) operating in Time Delay Integration (TDI) mode to achieve high signal-to-noise ratio. The front-end optical imager is a rotating mirror-based system that images the ground-scene onto a slit with a field of view of 16km x 1km. The slit-image is re-imaged and wavelength dispersed on the CCDs. As the ground-scene moves through the slit, it moves along the CCD columns as charge is moved along with it. The accumulated charge at the end of each column is collected in a serial pixel. Each of the 16 CCD outputs read out 32 columns of the same ground scene spaced 0.625nm apart. The 32-pixel serial register is swiftly read out before the next TDI cycle. The telescope is spinning at 5.77Hz to achieve the required spatial resolution. This results in a serial pixel readout speed of 8.5MHz. Each serial read-cycle goes through a reset and video period that are each sampled to create a low-noise correlated double sample value. This only allows 59ns for the reset and video to be asserted and settled before sampling. Due to the short time period, the response of the CCD exhibits serial pixel-to-pixel readout interference as the reset and video signals do not have time to fully settle before sampling. Each serial pixel value therefore has a dependence on the value of the preceding pixel value. This leads to a spectral measurement error of up to 0.3%. We explain the operation of the detection system, the behavior of the interference and the resulting wavelength error with results from ground testing and on-orbit characterization.

Ulrik B Gliese↗

Changes in water vapor adsorption and water film thickness in clayey materials as a function of relative humidity

Abstract Soil water, with adsorbed water being an important component, plays an important role in fluid flow and chemical movement in the unsaturated zone. The adsorbed water consists of water film and interlayer water, and its content is related to the relative humidity (RH). This study theoretically and experimentally focuses on the variation in adsorbed water content in clayey materials as the RH changes. Based on a slit‐pore model, three types of water (water film, interlayer water, and capillary water) could be present in the water vapor adsorption process. The variation of water film is obtained from the analysis of interfacial forces, and then the total water content can be quantitatively subdivided into these three types of water for different RH values. The slit‐pore adsorption model was used with experimental measurements (water vapor adsorption and N 2 physisorption) to quantify the amounts and interrelationships of these three different types of water to six clayey materials, namely three clay minerals (kaolinite, montmorillonite, and illite–smectite mixed layer) and three clay‐rich sediments from the Jianghan Plain in China. The main results are that (a) the volumes of water vapor adsorption are much greater than those of N 2 adsorption except for kaolinite; (b) interlayer water largely dominates the growth of total water content in montmorillonite and results in a concentration of 0.090 ml g −1 at 95% RH; and (c) the minimum thickness of water film is calculated to be 0.23 nm, and the maximum value is one‐third of the pore width by considering the interfacial forces.

54 ENVIRONMENTAL SCIENCES↗

Bridging adsorption behavior of confined CH 4 -CO 2 binary mixtures across scales

An accurate understanding of the competitive adsorption of CH 4 -CO 2 binary mixtures in nano-confined systems is critical for engineering CO 2 storage in shale gas reservoirs. Due to difficulties in making reliable experimental observations in nano-scale, atomistic simulations (ASs), such as the Grand Canonical Monte Carlo (GCMC) method, provide a viable approach to studying the adsorption behavior of confined fluids. ASs are, however, limited in the size of the compositional domain due to the high computational cost. This work proposes a framework that combines AS and the lattice Boltzmann (LB) method to bridge the physics of confined fluids across scales. The Peng–Robinson equation of state (PR-EoS) produces fugacity coefficients, which serve as input for conducting multi-component GCMC simulations. These GCMC simulations explore the competitive adsorption behavior of CH 4 -CO 2 in nano-slits at various composition, pressure, and channel-width conditions. Both components generate adsorption layers with high densities near the walls with CO 2 preferentially adsorbing compared to CH 4 on the organic walls of carbon sheets. At the mesoscale, a pseudopotential model represents the intermolecular forces in multi-component, multiple-relaxation-time LB simulations. The LB simulations are in good agreement with the GCMC results, allowing us to obtain values for tunable LB parameters. We then extend the use of LB to simulate adsorption behavior in complex networks with nano-sized channels. The phase behavior and fluid properties in the complex geometries of nano-channels differ from nano-slits and bulk systems. Furthermore, the bridging of physics from GCMC (microscale) to LB (mesoscale) via the macroscale PR-EoS connects the adsorption behavior of binary systems across scales.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Structural Anomalies and Electronic Properties of an Ionic Liquid under Nanoscale Confinement

Ionic liquids (ILs) promise far greater electrochemical performance compared to aqueous systems, yet key physicochemical properties governing their assembly at interfaces within commonly used graphitic nanopores remain poorly understood. Here, we combine synchrotron X-ray scattering with first-principles molecular dynamics simulations to unravel key structural characteristics of 1-alkyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide ([TFSI] – ) ionic liquids confined in carbon slit pores. X-ray scattering reveals selective pore filling due to size exclusion, while filled pores exhibit disruption in the IL intermolecular structure, the extent of which increases for narrower slit pores. First-principles simulations corroborate this finding and quantitatively describe how perturbations in the local IL structure, particularly the hydrogen-bond network, depend strongly on the degree of confinement. Despite significant deviations in structure under confinement, electrochemical stability remains intact, which is important for energy storage based on nanoporous carbon electrodes (e.g., supercapacitors).

36 MATERIALS SCIENCE↗

Nonlinear Shear Rheology of Entangled Polymer Rings

Steady-state shear viscosity η($\bar{γ}$) of unconcatenated ring polymer melts as a function of the shear rate $\bar{γ}$ is studied by a combination of experiments, simulations, and theory. Experiments using polystyrenes with Z ≈ 5 and Z ≈ 11 entanglements indicate weaker shear thinning for rings compared to linear polymers exhibiting power law scaling of shear viscosity η ~ $\bar{γ}$ –0.56 ± 0.02 , independent of chain length, for Weissenberg numbers up to about 10 2 . Nonequilibrium molecular dynamics simulations using the bead-spring model reveal a similar behavior with η ~ $\bar{γ}$ -0.57 ± 0.08 for 4 ≤ Z ≤ 57. Viscosity decreases with chain length for high $\bar{γ}$. In our experiments, we see the onset of this regime, and in simulations, which we extended to Wi ~ 10 4 , the nonuniversality is fully developed. In addition to a naive scaling theory yielding for the universal regime η ~ $\bar{γ}$ –0.57 , we developed a novel shear slit model explaining many details of observed conformations and dynamics as well as the chain length-dependent behavior of viscosity at large $\bar{γ}$. The signature feature of the model is the presence of two distinct length scales: the size of tension blobs and much larger thickness of a shear slit in which rings are self-consistently confined in the velocity gradient direction and which is dictated by the size of a chain section with relaxation time 1/$\bar{γ}$. These two length scales control the two normal stress differences. In this model, the chain length-dependent onset of nonuniversal behavior is set by tension blobs becoming as small as about one Kuhn segment. This model explains the approximate applicability of the Cox–Merz rule for ring polymers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Selectivity of nitrate and chloride ions in microporous carbons: the role of anisotropic hydration and applied potentials

Understanding ion transport in porous carbons is critical for a wide range of technologies, including supercapacitors and capacitive deionization for water desalination, yet many details remain poorly understood. For instance, an atomistic understanding of how ion selectivity is influenced by the molecular shape of ions, morphology of the micropores and applied voltages is largely lacking. In this work, we combined molecular dynamics simulations with enhanced sampling methods to elucidate the mechanism of nitrate and chloride selectivity in subnanometer graphene slit-pores. We demonstrate that nitrate is preferentially adsorbed over chloride in the slit-like micropores. This preferential adsorption was found to stem from the weaker hydration energy and unique anisotropy of the ion solvation of nitrate. Beside the effects of ion dehydration, we found that applied potential plays an important role in determining the ion selectivity, leading to a lower selectivity of nitrate over chloride at a high applied potential. We conclude that the measured ion selectivity results from a complex interplay between voltage, confinement, and specific ion effects-including ion shape and local hydration structure.

36 MATERIALS SCIENCE↗