Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “shaped beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Optical Imaging of Laser-Driven Fast Electron Weibel-like Filamentation in Overcritical Density Plasma

We report on the measurement of filamented transport of laser-generated fast electron beams in near-critical density plasma. A relativistic intensity long-wave-infrared laser irradiated a hydrodynamically shaped helium gas flow at an electron density n e ≃ 10 25 m − 3 , generating a large flux of fast electrons that propagated beyond the critical surface. The beam-to-background electron density ratio was sufficiently high to drive growth of Weibel-like filamentation, which was measured by optical probing to extend up to 800 μ m with radii ∼ 10 μ m . Particle-in-cell simulations reproduce the main features of the filamentation generation, suggesting that collisionless processes are dominant in these interactions. Expansion of the filaments after formation infers a fast electron heated plasma temperature ∼ 400 eV in the overcritical density plasma. Published by the American Physical Society 2025

43 PARTICLE ACCELERATORS↗

Chromaticity compensation of a ghost collider

The GHOST collider final focus system is a pure quadrupole-drift beamline targeting ¿* = 2 mm at four serial interaction points, with peak ¿-functions reaching ~65 km in the final triplet. Beam tracking simulations reveal that a nominal bunch develops a pronounced C-shape in longitu- dinal phase space at IP1, with ¿¿ growing from 0.15 mm to ~2.3 mm — a factor of ~15× increase that directly re- duces luminosity. The mechanism is identified as chromat- ically amplified betatron path length: off-momentum par- ticles acquire enlarged betatron amplitudes in the high-¿ final triplet, generating excess path length via the geometric ¿¿ = - 1/2 ¿ (¿'2 + ¿'2) ¿¿ integral. Within the monoenergetic Balandin framework, ¿2¿2 with ¿ = - 1/2 ¿ ¿ ¿¿ dominates ¿2¿2 by over four million times; the full beam ¿¿ is a fur- ther factor of ~27 larger, driven by ¿¿ -induced chromatic amplitude growth. Phase-advance scans confirm that ¿¿ is insensitive to the apochromatic (¿ ˜ 0) condition. When combined with the geometric hourglass effect, this distor- tion poses a challenge to maximizing luminosity within the current lattice design.

Gamage, B. [Thomas Jefferson National Accelerator ↗

Apparatus for preparing medical radioisotopes

Apparatus for radioisotope production includes housing, a plurality of target disks inside the housing and a curved windows positioned convex inward toward the disks. During operation, coolant flows though the housing across the disks and windows while electron beams passes through the window and the disks. The window temperature increases, rising the fastest in the middle of the window where the electron beam hits the window. A flat window would buckle because the center would deform during thermal expansion against the relatively unaffected periphery, but the curved window shape allows the window to endure high thermal and mechanical stress created by a combination of heating from the electron beam(s) and elevated pressure from coolant on the inside of the window. Such a window may be used for applications in which a pressurized coolant acts on only one side of the window.

Woloshun, Keith A.↗

Effects of negative triangularity shaping on energetic particle driven Alfvén eigenmodes in DIII-D

Shape variations from positive to negative triangularity may lead to improved performance regimes in a tokamak with a reduction in microturbulence as well as improved thermal confinement. The motivation of this investigation is to model and compare the neutral beam driven Alfvén eigenmode (AE) activity in two DIII-D discharges with positive and negative triangularity shaping of plasma. The simulations are performed using the linear version of the FAR3d code, which solves the reduced MHD equations for thermal plasma with addition of moment equations for the energetic ion density and parallel velocity with appropriate Landau closure relations. Overall, our numerical results indicate that for similar physical parameters, the unstable AEs observed in the negative triangularity case have lower growth rates as compared to the positive triangularity regime. Our findings may be useful to analyze the influence of the reverse-D like geometry on the AE instabilities in DIII-D and may lead to better configurations for minimizing fast ion losses in a tokamak device.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evolution of ELMs, pedestal profiles and fluctuations in the inter-ELM period in NBI and ECH dominated discharges in DIII-D

In DIII-D, it has been observed that ELM frequency decreases by 40% and ELM spacing becomes more regular in time when heating is changed from pure neutral beam injection (NBI) to predominantly electron cyclotron heating (ECH) in ITER Similar Shape plasmas. In comparison with pure the NBI discharges, pedestal fluctuations in magnetics and density increase in the ECH dominated discharges. Recovery of the pedestal profiles like electron density (ne), temperature (Te) and pressure (pe) shows marked differences for these two heating schemes. Average profiles in the last 30% of the ELM cycle shows higher Te, lower ne, and similar pe at the pedestal top for the ECH discharge when compared to the NBI discharge. Here, the gradient of Te (∇Te) is also steeper at the pedestal in the ECH discharge. Magnetic fluctuations show 3 distinct modes in 13~116 kHz in the ECH discharges only. ne fluctuations show two modes evolving in the inter-ELM period of the ECH discharge, a low frequency (400 kHz) quasi-coherent mode (LFQC) and high frequency (~2 MHz) broadband (HFB) fluctuations. Evolution of these modes has marked correspondence with the inter-ELM ∇Te recovery. A sharp decrease in the Dα baseline is observed whenever the LFQC weakens and the HFB grows, prior to each large ELM. Transport coefficients obtained from TRANSP shows that MTM and/or TEM are plausible candidates for the observed fluctuations. Linear gyrofluid simulation (TGLF) corroborates this characterization. TGLF shows that the linear growth rate of the most dominant mode peaks at ion-scale (kθρs ~ 0.4) at the pedestal steep gradient and the frequency is in the electron diamagnetic direction. It is proposed that increased fluctuations in the ECH dominated case, due to increased ∇Te, caused an increase in fluctuation-driven transport in the pedestal and slowed the pedestal recovery between ELMs, leading to a reduction in the ELM frequency.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Amplification of mid-IR continuum for broadband 2D IR spectroscopy

We report the generation and characterization of microjoule level, broad bandwidth femtosecond pulses in the mid-infrared (MIR) using optical parametric amplification of continuum MIR seed pulses in GaSe. The signal (3 μm) and idler (6 μm) pulses have energies of 6 μJ and 3 μJ with bandwidths of ∼950 cm −1 and 650 cm −1 FWHM and pulse lengths of 34 fs and 80 fs. Broadband 2D IR spectra of O-H and N-H transitions are acquired with the signal beam demonstrating the capabilities of this source for cross peak and line shape measurements.

Optics↗

Measurement and modeling of beam transport in the FODO line of the Spallation Neutron Source Beam Test Facility

Ongoing studies at the Spallation Neutron Source (SNS) Beam Test Facility (BTF) seek to understand and model bunch dynamics in a high-power LINAC front-end. The BTF has recently been upgraded with a reconfiguration from a U-shaped line to a Straight line. We report the current state of model benchmarking, with a focus on RMS beam sizes within the FODO line. The beam measurement is obtained via three camera/screen pairs in the FODO line. This presentation discusses the methodology and results of this measurement.

Thompson, Trent↗

Time-average holographic estimation of Poisson's ratio by Cornu's method from mode shapes

More than 150 years ago, Marie Alfred Cornu first demonstrated his method of using interferometry to directly measure Poisson’s ratio from a radially bent beam. It is an elegant approach to measuring Poisson’s ratio of a beam requiring only two length measurements. Cornu’s method combines the high precision of interferometry with a four-point bending apparatus. This research simulates an interferometry technique called time-average scanning digital holography to make direct estimates of Poisson’s ratio from the antin odes of a mode shape. We show it is possible to make direct estimates of Poisson’s ratio from the antinode of a mode shape although the estimates diverge from the true value of Poisson’s ratio. We find that the di vergence is proportional to the distance between the nodes of a mode shape. We then develop an expression for converting our direct estimate back to within two percent of the true value of Poisson’s ratio for a thin, homogeneous, and hinged-hinged beam, or plate. The remainder of the research seeks to extend this method to combinations of clamped, free, and hinged boundary conditions.

42 ENGINEERING↗

The estimation of Poisson’s ratio by time-averaging and Cornu’s method for isotropic beams

Prior research suggests that direct static (e.g., uniaxial testing) and dynamic (e.g., ultrasonic wave propagation analysis) measurements differ in the estimation of Poisson’s ratio because anisotropies and heterogeneities in the sample material affect the two types of tests differently. Even assuming isotropic and homogeneous material properties, prior research further suggests that discrepancies between static/dynamic test results will exist because the error of the diagnostic techniques for the measurand are inherently different. Finally, thermodynamic effects are not present in static tests but can significantly affect dynamic test results. Given the potential for all these variables to produce discrepancies, it would be helpful to have the measurement of Poisson’s ratio obtainable from the same theory and experimental measurements by either static or dynamic testing methods. Our finite element calculations show that by combining time-averaged scanning digital holography with Cornu’s method, it is theoretically possible to estimate the effective Poisson’s ratio from the anticlastic contours at the antinode of the first out-of-plane bending mode shape. This is true regardless of frequency and therefore applicable for both static and dynamic measurements. Our results show that the estimate of Poisson’s ratio by Cornu’s method using data from simulations of mode shapes approaches the true value of Poisson’s ratio. Additionally, our research suggests that beam geometry and boundary conditions are fundamental factors limiting the convergence of the estimate of Poisson’s ratio to the true value of Poisson’s ratio regardless of performing a static or dynamic test.

42 ENGINEERING↗

Temporal pre-pulse shaping in dual pulse laser produced plasma for the optimization of the EUV source in tin microdroplet system

Dual-laser beams interacting with small droplets of liquid tin are currently the most efficient systems for producing the 13.5 nm EUV photon radiation source required for the next generation microchips. Usually, EUV light is produced during the second main-pulse stage, while the pre-pulse (PP) is used for target preparation, i.e., droplet preheating, vaporization, and target deformation. However, the PP laser energy can be utilized more efficiently if the EUV producing plasma is being developed during the PP stage as well. In this work, we study the ways of optimization of the PP laser temporal shape to achieve conditions for maximum EUV output during the pre-pulse. The size of the deformed droplet is kept optimized for the following main laser pulse. Our simulations showed a significant increase in the EUV output at the pre-pulse stage when a ramping profile is used for the laser temporal shape. Using the ramped square pre-pulse produces 24% gain in the EUV output in comparison with the standard Gaussian temporal profile (i.e., regular Nd:YAG shape) for the same energy of the laser pulse.

36 MATERIALS SCIENCE↗

Measurements of the beam longitudinal properties in the Fermilab Linac

The Fermilab Linac delivers 400$\,$MeV, 25$\,$mA H$^-$ beam to a rapid cycling synchrotron called the Booster. Parameters of the Linac beam affect Booster performance and therefore quantifying them is important. The longitudinal bunch parameters are reconstructed using a Bunch Shape Monitor (BSM) installed in the middle of the Linac. For that, the bunch length is measured as a function of the phase of an upstream cavity and fitted to simulations. The cavity gradient and its phase with respect to the beam are recovered from readings of Beam Position Monitors. Since the cavity provides a significant transverse defocusing, the BSM measurements are correlated with transverse beam size measurements by a wire scanner. Simulations connect these three types of measurements, allowing to deduce the longitudinal emittance and Courant-Snyder parameters.

Sharankova, Ralitsa [Fermilab] (ORCID:000000027014↗

Effects of Focused Ion Beam Lithography on La 2– x Sr x CuO 4 Single Crystals

Focused ion beam (FIB) milling is a mask-free lithography technique that allows the precise shaping of 3D materials on the micron and sub-micron scale. The recent discovery of electronic nematicity in La 2–x Sr x CuO 4 (LSCO) thin films triggered the search for the same phenomenon in bulk LSCO crystals. With this motivation, we have systematically explored FIB patterning of bulk LSCO crystals into micro-devices suitable for longitudinal and transverse resistivity measurements. We found that several detrimental factors can affect the result, ultimately compromising the possibility of effectively using FIB milling to fabricate sub-micrometer LSCO devices, especially in the underdoped regime.

36 MATERIALS SCIENCE↗

4D-STEM of Beam-Sensitive Materials

We report that a scanning electron nanobeam diffraction, or 4D-STEM (four-dimensional scanning transmission electron microscopy), is a flexible and powerful approach to elucidate structure from "soft" materials that are challenging to image in the transmission electron microscope because their structure is easily damaged by the electron beam. In a 4D-STEM experiment, a converged electron beam is scanned across the sample, and a pixelated camera records a diffraction pattern at each scan position. This four-dimensional data set can be mined for various analyses, producing maps of local crystal orientation, structural distortions, crystallinity, or different structural classes. Holding the sample at cryogenic temperatures minimizes diffusion of radicals and the resulting damage and disorder caused by the electron beam. The total fluence of incident electrons can easily be controlled during 4D-STEM experiments by careful use of the beam blanker, steering of the localized electron dose, and by minimizing the fluence in the convergent beam thus minimizing beam damage. This technique can be applied to both organic and inorganic materials that are known to be beam-sensitive; they can be highly crystalline, semicrystalline, mixed phase, or amorphous. One common example is the case for many organic materials that have a π-π stacking of polymer chains or rings on the order of 3.4-4.2 Å separation. If these chains or rings are aligned in some regions, they will produce distinct diffraction spots (as would other crystalline spacings in this range), though they may be weak or diffuse for disordered or weakly scattering materials. We can reconstruct the orientation of the π-π stacking, the degree of π-π stacking in the sample, and the domain size of the aligned regions. This Account summarizes illumination conditions and experimental parameters for 4D-STEM experiments with the goal of producing images of structural features for materials that are beam-sensitive. We will discuss experimental parameters including sample cooling, probe size and shape, fluence, and cameras. 4D-STEM has been applied to a variety of materials, not only as an advanced technique for model systems, but as a technique for the beginning microscopist to answer materials science questions. It is noteworthy that the experimental data acquisition does not require an aberration-corrected TEM but can be produced on a variety of instruments with the right attention to experimental parameters.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modelling of sawtooth-induced fast ion transport in positive and negative triangularity in TCV

Internal kinks are a common magneto hydro-dynamic (MHD) instability observed in tokamak operation when the q profile in the plasma core is close to unity. This MHD instability impacts both the transport of the bulk plasma (current, particle and energy transport) and minority species, such as fast ions. In TCV (R 0 /a = 0.88 m/0.25 m) the fast ion population is generated in the plasma by neutral beam tangential injection of energies up to 28 keV. TCV features 16 active shaping coils permitting a great flexibility in plasma shape, including negative triangularity (δ) configurations that show surprisingly high confinement. This study focuses on the transport of fast ions induced by sawteeth, by comparing two triangularity cases and simulation results with experimental data. Comparison of two equilibria with opposite δ shows that the fast ion drifts are larger for δ < 0. Furthermore, the sawtooth-induced transport in this case is larger than δ > 0 in similar conditions. Additionally, comparison with experimental data confirms the dominance of the modification of thermal kinetic profiles following the sawtooth crash in explaining drops in the neutron rates and FIDA signals. Additional fast ion diffusion, however, improves the interpretation of the experimental data. For δ < 0, the amplitude of the perturbation better representing the experimental data is larger. Finaly, an exploratory study for 50 keV particles (soon available in TCV) shows that the situation does not worsen for such particles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optics Reconstruction in the SCL Section of the FNAL Linac

The Side-CoupledLinac (SCL) section oftheFNAL linac acceleratesthe beamfrom 117 MeV to 401.5 MeV, operatingat 22-24mA beam current. Transverse focusing is performedby32 quadrupoles, and the beam orbit is guidedby19dipolecorrectors andmeasuredby29 BPMs. The bunch length is measured in a single location by a Bunch Shape Monitor (BSM). This paper presents a three-step reconstruction of the machine optics. First, the transverse and longitudinal Twiss parameters at the start of the SCL section are determined using quadrupole scans and BSM measurements at different settings o fan upstream cavity. Second, the quadrupole calibrations are adjusted based on differential-trajectory measurements. Finally, the beam is propagated along the SCL linac using the code Trace Win. A comparison between Trace Win simulations and the beam envelope measured bythe12wirescanners of the SCL linac was performed. Transverse and longitudinal beam parameters at the entrance of the transition section will be reported

Carneiro, Jean-Paul [Fermilab]↗

Surface Analysis Insight Note: Observations relating to photoemission peak shapes, oxidation state, and chemistry of titanium oxide films

It is common practice to describe the coordination of metal atoms in a binding configuration with their nearest neighbors in terms of oxidation state, a measure by which the number of electrons redistributed between atoms forming chemical bonds. In XPS terms, change to an oxidation state is commonly inferred by correlating photoemission signal with binding energy. The assumption, when classifying photoemission signals into distinct spectral shapes, is that a distribution of intensities shifted to lower binding energy is evidence of a reduction in oxidation state. In this Insight note, we raise the prospect that changes in photoemission peak shape may occur without obvious changes, determined by XPS in stoichiometry for a material. It is well known that TiO 2 measured by XPS yields reproducible Ti 2p photoemission peaks. However, on exposing TiO 2 to ion beams, Ti 2p photoemission evolves to complex distributions in intensity, which are particularly difficult to analyze by traditional fitting of bell-shaped curves to these data. For these reasons, in this Insight note, a thin film of TiO 2 deposited on a silicon substrate is chosen for analysis by XPS and linear algebraic techniques. Alterations in spectral shapes created from modified TiO 2 , which might be interpreted as the change in oxidation state, are assessed in terms of relative proportions of titanium to oxygen. It is found through detailed analysis of spectra that quantification by XPS, using procedures routinely used in practice, is not in accord with the typical interpretations of photoemission shapes. The data processing methods used and results presented in this work are of particular relevance to elucidating fundamental phenomena governing the surface evolution of materials-enabled energy processes where cyclic/non-steady usage changes the nature of bonding, especially in the presence of contaminants.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Deep underground measurement of B 11 ( α , n ) N 14

The primordial elemental abundance composition of the first stars leads to questions about their modes of energy production and nucleosynthesis. The formation of 12 C has been thought to occur primarily through the 3α process, however, alternative reaction chains may contribute significantly, such as 7 Li (α, γ) 11 B (α,n) 14 N. This reaction sequence cannot only bypass the mass A = 8 stability gap, but could also be a source of neutrons in the first star environment. However, the efficiency of this reaction chain depends on the possible enhancement of its low energy cross section by α-cluster resonances near the reaction threshold. A new study of the reaction 11 B(α,n) 14 N has been undertaken at the CASPAR underground facility at beam energies from 300–700 keV. A 4π neutron detector in combination with pulse shape discrimination at low background conditions resulted in the ability to probe energies lower than previously measured. Further, resonance strengths were determined for both the resonance at a laboratory energy of 411 keV, which was measured for the second time, and for a new resonance at 337 keV that has been measured for the first time. This resonance, found to be significantly weaker than previous estimates, dominates the reaction rate at lower temperatures (T < 0.2 KG) and reduces the reaction rate in first star environments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Tandem neural network-based controller for x-ray bimorph mirrors

Nanometer-scale shape control of x-ray mirrors is crucial for coherent x-ray beam experiments at low-emittance synchrotron beamline instruments. Piezoelectric bimorph mirrors offer adaptive control but are hindered by nonlinearities such as cross talk, creep, and hysteresis. To overcome these limitations, we present a novel feedback-free control solution, inspired by the proportional–integral–derivative (PID) scheme, driven by tandem neural networks (TNNs). Using task-specific datasets, the TNN-based system predicts actuator voltages with greater speed, accuracy, and stability than a single NN-based model. This approach is ideal for real-time applications, such as adapting beam focus to dynamic sample sizes while maintaining precise wavefront quality. Our findings highlight the potential of artificial intelligence in rapidly optimizing adaptive optics and managing nonlinear control systems.

Zhang, Runyu↗