Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “shape measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Development and validation of a gamma-ray detection response model for neutron-diagnosed subcritical experiments

In a neutron-diagnosed subcritical experiment, a highly sensitive and fast detector is required to accurately determine the true fission γ-ray emission rate from an object composed of special nuclear material under interrogation, in addition to a proper detector response model for use in forward modeling. We present the development of a detector response model that is based in GEANT4 and uses post-processing techniques to include photomultiplier tube time and pulse height response effects. We also define a set of detector performance evaluation metrics that emphasized our experimental objectives. A suite of time and pulse height response measurements for several diverse detector assemblies are described. These assemblies were simulated with this response model and benchmarked against the laboratory measurements. This response model reproduces the pulse height curve shapes and performance hierarchy of the measured detectors well. Additionally, the simulated time response curves exhibit reasonable agreement with counterpart measurements. These measurements and simulation results together suggest that a large volume EJ-299-49 plastic scintillator that is mated to an ultraviolet transmitting plastic light guide and relies on total internal reflection for light transport to the photocathode will provide significantly faster timing, increase pulse height by a factor of 3, and require 25% less γ rays to meet experimental needs, compared to the candidate detector design developed prior to the availability of this response model. Application of this response model and associated performance metrics in the context of large-scale design sensitivity studies is also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using multimodal X-ray computed tomography to advance 3D petrography: A non-destructive investigation of olivine inside a carbonaceous chondrite

Rocks form in three dimensions through time and studying them provides information from inside dynamic systems we cannot otherwise observe. Yet how we typically access the interior of the rocks themselves to gain that information may limit our understanding and influence how we reconstruct the processes that formed them. Here, we demonstrate combined non-destructive 3D X-ray imaging techniques that produce quantitative densitometric and crystallographic maps of entire individual grains inside a rock. Olivine grains throughout a sample of the carbonaceous chondrite Northwest Africa (NWA) 11346 were each characterized by size, shape, composition, zoning intensity, and crystallographic orientation. The addition of 3D crystallographic mapping to calibrated 3D densitometric analysis—used to calculate chemical composition—demonstrates a fully non-destructive petrographic method and provides unique insight. For instance, in our case, using crystallographic data to delineate individual grains and then measuring the 3D size, shape, and composition of each distinguishes variably reset relict grains from those later crystallized after a melting event. Intersection in a 2D slice could not have led to this interpretation because the integration of three-dimensional size, rounding, composition, location, and crystallographic orientation measured from each grain forms the key patterns. Multimodal laboratory X-ray imaging has strong potential to advance 3D petrography.

36 MATERIALS SCIENCE↗

Computing a Stable Distance on Merge Trees

Distances on merge trees facilitate visual comparison of collections of scalar fields. Two desirable properties for these distances to exhibit are 1) the ability to discern between scalar fields which other, less complex topological summaries cannot and 2) to still be robust to perturbations in the dataset. The combination of these two properties, known respectively as stability and discriminativity, has led to theoretical distances which are either thought to be or shown to be computationally complex and thus their implementations have been scarce. In order to design similarity measures on merge trees which are computationally feasible for more complex merge trees, many researchers have elected to loosen the restrictions on at least one of these two properties. The question still remains, however, if there are practical situations where trading these desirable properties is necessary. Here we construct a distance between merge trees which is designed to retain both discriminativity and stability. While our approach can be expensive for large merge trees, we illustrate its use in a setting where the number of nodes is small. This setting can be made more practical since we also provide a proof that persistence simplification increases the outputted distance by at most half of the simplified value. As a result, we demonstrate our distance measure on applications in shape comparison and on detection of periodicity in the von Kármán vortex street.

97 MATHEMATICS AND COMPUTING↗

Extending empirical constraints on the SZ–mass scaling relation to higher redshifts via HST weak lensing measurements of nine clusters from the SPT-SZ survey at z ≳ 1

We present a Hubble Space Telescope (HST) weak gravitational lensing study of nine distant and massive galaxy clusters with redshifts 1.0 ≲ z ≲ 1.7 (z median = 1.4) and Sunyaev Zel’dovich (SZ) detection significance ξ > 6.0 from the South Pole Telescope Sunyaev Zel’dovich (SPT-SZ) survey. We measured weak lensing galaxy shapes in HST/ACS F606W and F814W images and used additional observations from HST/WFC3 in F110W and VLT/FORS2 in U HIGH to preferentially select background galaxies at z ≳ 1.8, achieving a high purity. We combined recent redshift estimates from the CANDELS/3D-HST and HUDF fields to infer an improved estimate of the source redshift distribution. We measured weak lensing masses by fitting the tangential reduced shear profiles with spherical Navarro-Frenk-White (NFW) models. We obtained the largest lensing mass in our sample for the cluster SPT-CL J2040—4451, thereby confirming earlier results that suggest a high lensing mass of this cluster compared to X-ray and SZ mass measurements. Combining our weak lensing mass constraints with results obtained by previous studies for lower redshift clusters, we extended the calibration of the scaling relation between the unbiased SZ detection significance ζ and the cluster mass for the SPT-SZ survey out to higher redshifts. We found that the mass scale inferred from our highest redshift bin (1.2 < z < 1.7) is consistent with an extrapolation of constraints derived from lower redshifts, albeit with large statistical uncertainties. Thus, our results show a similar tendency as found in previous studies, where the cluster mass scale derived from the weak lensing data is lower than the mass scale expected in a PlanckνΛCDM (i.e. νΛ cold dark matter) cosmology given the SPT-SZ cluster number counts.

79 ASTRONOMY AND ASTROPHYSICS↗

Microsecond Isomer at the N = 20 Island of Shape Inversion Observed at FRIB

Excited-state spectroscopy from the first experiment at the Facility for Rare Isotope Beams (FRIB) is reported. A 24(2)-μs isomer was observed with the FRIB Decay Station initiator (FDSi) through a cascade of 224- and 401-keV γ rays in coincidence with 32 Na nuclei. This is the only known microsecond isomer (1 μs ≤T 1/2 <1 ms) in the region. This nucleus is at the heart of the N=20 island of shape inversion and is at the crossroads of the spherical shell-model, deformed shell-model, and ab initio theories. It can be represented as the coupling of a proton hole and neutron particle to 32 Mg, 32 Mg+π -1 +ν +1 . This odd-odd coupling and isomer formation provides a sensitive measure of the underlying shape degrees of freedom of 32 Mg, where the onset of spherical-to-deformed shape inversion begins with a low-lying deformed 2 + state at 885 keV and a low-lying shape-coexisting 0$^+_2$ state at 1058 keV. Here, we suggest two possible explanations for the 625-keV isomer in 32 Na: a 6 - spherical shape isomer that decays by E2 or a 0 + deformed spin isomer that decays by M2. The present results and calculations are most consistent with the latter, indicating that the low-lying states are dominated by deformation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Higgs Self Couplings Measurements at Future proton-proton Colliders

The Higgs boson trilinear and quartic self-couplings are directly related to the shape of the Higgs potential; measuring them with precision is extremely important, as they provide invaluable information on the electroweak symmetry breaking and the electroweak phase transition.In this paper, we perform a detailed analysis of double Higgs boson production, through the gluon-gluon fusion process, in the most promising decay channels $b\bar{b} \gamma\gamma$, $b\bar{b} \tau\tau$, and $b\bar{b}b\bar{b}$ for several future colliders: the HL-LHC at 14 TeV and the FCC-hh at 100 TeV, assuming respectively 3 $ab^{-1}$ and 30 $ab^{-1}$ of integrated luminosity.In the HL-LHC scenario, we expect an upper limit on the di-Higgs cross-section production of 0.76 at 95\% confidence level, corresponding to a significance of 2.8 $\sigma$.In the FCC-hh scenario, depending on the assumed detector performance and systematic uncertainties, we expect that the Higgs self-coupling will be measured with a precision in the range 4.8-8.5\% at 95\% confidence level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Discovering new forces with gravitational waves from supermassive black holes

Supermassive black hole binary mergers generate a stochastic gravitational wave background detectable by pulsar timing arrays. While the amplitude of this background is subject to significant uncertainties, the frequency dependence is a robust prediction of general relativity. Here we show that the effects of new forces beyond the Standard Model can modify this prediction and introduce unique features into the spectral shape. In particular, we consider the possibility that black holes in binaries are charged under a new long-range force, and we find that pulsar timing arrays are capable of robustly detecting such forces. Supermassive black holes and their environments can acquire charge due to high-energy particle production or dark sector interactions, making the measurement of the spectral shape a powerful test of fundamental physics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of charged-current $\nu_\mu$ and $\bar{\nu}_\mu$ cross sections on hydrocarbon in a shallow inelastic scattering region

This MINERvA analysis is the first neutrino and antineutrino study of a shallow inelastic scattering region, which is the transition region between resonant production and deep inelastic scattering processes. This transition is explicitly included in this study by expanding the scope of shallow inelastic scattering to include not only the mainly lower-$Q^2$ nonresonant pion production but also the kinematic region where pion production off quarks within the nucleon becomes significant with $Q^2$ below the onset of the deep-inelastic scattering region defined in this analysis. To reduce the resonance background the kinematic region 1.5 $<$$W$$<$ 2 GeV/$c^2$ was chosen. In addition to the inclusive differential cross section measurements, to emphasize SIS interactions off quarks within the nucleon a sample with $Q^2$$\geq$ 1 GeV/$c^2$ was also analyzed. The measurements of one-dimensional cross sections at $\left\langle E_\nu \right\rangle \sim 6$ GeV on hydrocarbon of $Q^2$, Bjorken x and muon momentum variables are compared with modified predictions from the GENIE 2 neutrino generator as well as predictions of other neutrino simulators GiBUU, NEUT, NuWro and an alternative GENIE 3 version. Significant discrepancies both in shape and magnitude between measurements and neutrino simulator predictions of all variables have been observed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Charged-particle multiplicity distributions over a wide pseudorapidity range in p–Pb collisions at $\sqrt{s_{NN}}$ = 5.02 TeV

This paper presents the primary charged-particle multiplicity distributions in proton–lead collisions at a centre-of-mass energy per nucleon–nucleon collision of $\sqrt{s_{NN}}$ = 5.02 TeV. The distributions are reported for non-single diffractive collisions in different pseudorapidity ranges. The measurements are performed using the combined information from the Silicon Pixel Detector and the Forward Multiplicity Detector of ALICE. The multiplicity distributions are parametrised with a double negative binomial distribution function which provides satisfactory descriptions of the distributions for all the studied pseudorapidity intervals. The data are compared to models and analyzed quantitatively, evaluating the first four moments (mean, standard deviation, skewness, and kurtosis). The shape evolution of the measured multiplicity distributions is studied in terms of KNO variables and it is found that none of the considered models reproduces the measurements. This paper also reports on the average charged-particle multiplicity, normalised by the average number of participating nucleon pairs, as a function of the collision energy. The multiplicity results are then compared to measurements made in proton–proton and nucleus–nucleus collisions across a wide range of collision energies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Performance assessment of PHITS simulations for the inverse-kinematic p( 7 Li,n) 7 Be reaction based on fast-neutron measurements with a diamond detector

The inverse-kinematics p( 7 Li,n) 7 Be reaction produces forward-focused neutron emission, offering enhanced usable flux and reduced shielding requirements. Reliable simulation of such neutron fields is essential for the development of compact accelerator-based neutron sources. In this study, a PHITS-based simulation framework for the reaction was experimentally assessed using fast-neutron measurements. Forward-directed neutrons were measured with a diamond neutron detector and quantitatively compared with simulations with newly prepared IK-Frag cross-section file based on the proton-induced reaction data in ENDF/B-VIII.1, TENDL-2023, and JENDL-4.0/HE. Measurements and simulations were performed for incident 7 Li 3+ energies ranging from 15.0 to 25.0 MeV using a 50 μm-thick polypropylene target. For all conditions, the PHITS-based simulation framework reproduced the deposited energy spectra at the correct order of magnitude. The comparison of deposited energy spectra in the diamond detector showed high correlation coefficients across all investigated energies, indicating reasonable agreement in spectral shape between simulations and measurements. This work represents an initial step toward establishing a benchmark for PHITS simulations of the inverse kinematic reaction between an incident lithium-ion and a proton target.

43 PARTICLE ACCELERATORS↗

Biomass char gasification kinetic rates compared to data, including ash effects

This investigation provides both experimental and theoretical analyses of biomass char gasification kinetics over 1150–1350 °C in the environment of CO 2 , H 2 O and combinations of these reactants. The experimental data include continuous measurements of particle mass, external and internal temperatures, shape, and size with periodic but not continuous measurements of char porosity, pore size distribution, and pore surface area. The model describes heterogeneous char gasification for poplar wood, corn stover and switchgrass in different shapes and industrially relevant sizes (12.5 mm and smaller). Nonlinear least-squares regression produces optimized power-law model parameters for global kinetics that describe biomass char gasification with respect to both CO 2 and H 2 O separately and in combination. A single set of kinetic parameters describes reaction rates for all three fuels. Model simulations agree with measured data at all stages of char conversion even though the observed mass loss rates change significantly with conversion. In conclusion, the change in rate with conversion depends strongly on ash content, and this investigation provides a simple and theoretically based reaction rate expression that includes the effect of inert ash occupying an increasing portion of the reactive surface with increased conversion.

09 BIOMASS FUELS↗

Mechanical Comparison of Short Models of Nb$_3$ Sn Low-$\beta$ Quadrupole for the Hi-Lumi LHC

MQXF is the Nb 3 Sn Low-β quadrupole magnet that the HL-LHC project is planning to install in the LHC interaction regions in 2026 to increase the LHC integrated luminosity. The magnet will be fabricated in two different lengths: 4.2 m for MQXFA, built in the US by the Accelerator Upgrade Project (AUP), and 7.15 m for MQXFB, fabricated by CERN. In order to qualify the magnet design and characterize its performance with different conductors, cable geometries and pre-load configurations, five short model magnets, called MQXFS, were fabricated, assembled and tested. We compare the mechanical behavior of short model magnets using experimental data and new numerical models that take into account the measured coil sizes as a function of position.

43 PARTICLE ACCELERATORS↗

Multidifferential study of identified charged hadron distributions in Z -tagged jets in proton-proton collisions at $\sqrt{s} =13$ TeV

Jet fragmentation functions are measured for the first time in proton-proton collisions for charged pions, kaons, and protons within jets recoiling against a Z boson. The charged-hadron distributions are studied longitudinally and transversely to the jet direction for jets with transverse momentum 20 < p T < 100 GeV and in the pseudorapidity range 2.5 < η <4. The data sample was collected with the LHCb experiment at a center-of-mass energy of 13 TeV, corresponding to an integrated luminosity of 1.64 fb –1 . Triple differential distributions as a function of the hadron longitudinal momentum fraction, hadron transverse momentum, and jet transverse momentum are also measured for the first time. This helps constrain transverse-momentum-dependent fragmentation functions. Differences in the shapes and magnitudes of the measured distributions for the different hadron species provide insights into the hadronization process for jets predominantly initiated by light quarks.

79 ASTRONOMY AND ASTROPHYSICS↗

Self-calibration strategies for reducing systematic slope measurement errors of autocollimators in deflectometric profilometry

Deflectometric profilometers are used to precisely measure the form of beam shaping optics of synchrotrons and X-ray free-electron lasers. They often utilize autocollimators which measure slope by evaluating the displacement of a reticle image on a detector. Based on our privileged access to the raw image data of an autocollimator, novel strategies to reduce the systematic measurement errors by using a set of overlapping images of the reticle obtained at different positions on the detector are discussed. It is demonstrated that imaging properties such as, for example, geometrical distortions and vignetting, can be extracted from this redundant set of images without recourse to external calibration facilities. This approach is based on the fact that the properties of the reticle itself do not change – all changes in the reticle image are due to the imaging process. Firstly, by combining interpolation and correlation, it is possible to determine the shift of a reticle image relative to a reference image with minimal error propagation. Secondly, the intensity of the reticle image is analysed as a function of its position on the CCD and a vignetting correction is calculated. Thirdly, the size of the reticle image is analysed as a function of its position and an imaging distortion correction is derived. It is demonstrated that, for different measurement ranges and aperture diameters of the autocollimator, reductions in the systematic errors of up to a factor of four to five can be achieved without recourse to external measurements.

47 OTHER INSTRUMENTATION↗

Novel X-ray scanning technique for in-situ alignment of photo-detectors in the MEGII calorimeter

Here, we describe and show results of a novel technique to measure with high precision the positions of photodetectors installed in the upgraded liquid xenon calorimeter of the MEG II experiment. The measurement was done by detecting the signal in individual photo-detectors as the front surface of the calorimeter was scanned in axial (Z) and azimuthal (Φ) directions with a precisely controlled, thin, collimated beam of X-rays obtained from a 57 CoX-ray source. The measurements were made when the calorimeter was cold and operational, under which conditions they could not otherwise be made. This technique is used to check for changes in the photodetector positions due to the effects of cooling and thermal cycling of the support structure and to provide a reference between the positions of the operational photodetectors and alignment markers on the cryostat exterior. The use of an essentially monochromatic X-ray source allowed ancillary measurements of photodetector properties, including pulse shape, relative gain, and variation in response over the photodetector surface. Measurement uncertainties below 0.6mm in Z and 0.7 mrad in Φ have been achieved, well within the requirements for the MEG II performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Higgs Self Couplings Measurements at Future proton-proton Colliders: a Snowmass White Paper

The Higgs boson trilinear and quartic self-couplings are directly related to the shape of the Higgs potential; measuring them with precision is extremely important, as they provide invaluable information on the electroweak symmetry breaking and the electroweak phase transition. In this paper, we perform a detailed analysis of double Higgs boson production, through the gluon gluon fusion process, in the most promising decay channels di-bottom-quark di-photons, di-bottom-quark di-tau, and four-bottom-quark for several future colliders: the HL-LHC at 14 TeV and the FCC-hh at 100 TeV, assuming respectively 3 inverse ab and 30 inverse ab of integrated luminosity. In the HL LHC scenario, we expect an upper limit on the di Higgs cross section production of 0.76 at 95% confidence level, corresponding to a significance of 2.8 sigma. In the FCC-hh scenario, depending on the assumed detector performance and systematic uncertainties, we expect that the Higgs self-coupling will be measured with a precision in the range 4.8-8.5% at 95% confidence level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Simple, compact, high-resolution monochromatic x-ray source for characterization of x-ray calorimeter arrays

X-ray calorimeters routinely achieve very high spectral resolution, typically a few eV full width at half maximum (FWHM). Measurements of calorimeter line shapes are usually dominated by the natural linewidth of most laboratory calibration sources. This compounds the data acquisition time necessary to statistically sample the instrumental line broadening and can add systematic uncertainty if the intrinsic line shape of the source is not well known. To address these issues, we have built a simple, compact monochromatic x-ray source using channel cut crystals. A commercial x-ray tube illuminates a pair of channel cut crystals that are aligned in a dispersive configuration to select the Kα1 line of the x-ray tube anode material. The entire device, including the x-ray tube, can be easily hand-carried by one person and may be positioned manually or using a mechanical translation stage. The output monochromatic beam provides a collimated image of the anode spot with magnification of unity in the dispersion direction (typically 100 μm–200 μm for the x-ray tubes used here) and is unfocused in the cross-dispersion direction so that the source image in the detector plane appears as a line. We measured output count rates as high as 10 count/s/pixel for the Hitomi soft x-ray spectrometer, which had 819 μm square pixels. We implemented different monochromator designs for energies of 5.4 keV (one design) and 8.0 keV (two designs), which have effective theoretical FWHM energy resolution of 0.125 eV, 0.197 eV, and 0.086 eV, respectively; these are well-suited for optimal calibration measurements of state-of-the art x-ray calorimeters. We measured an upper limit for the energy resolution of our Cr Kα1 monochromator of 0.7 eV FWHM at 5.4 keV, consistent with the theoretical prediction of 0.125 eV.

47 OTHER INSTRUMENTATION↗

Performance of a Prototype Heliostat Having a Twisting Mechanism to Maintain Focus Throughout the Day

A prototype heliostat has been designed and built with a rectangular reflector whose shape is altered automatically through the day, to maximize concentration at the receiver. The shape changes needed to form solar disc images, which give the highest possible concentration, can be realized by twisting the reflector from its corners, provided that a target-oriented, dual-axis mount is used. Then a cam mechanism connected to the second (cross) axis drive, turning with the angle of incident sunlight, may be used to twist the reflector as needed. Our prototype reflector comprises a single glass mirror, 2.4 m x 3.3 m, attached to a steel frame. Four diagonal back struts extend from the central mechanism out to the rectangular frame corners. The glass mirror of the prototype is attached to the steel frame by 58 screw actuators. Before twisting the frame, the glass shape is adjusted to the biconic shape needed to form a 1 m diameter disc image on a 113 m distant target when sunlight is incident at 60°. To form disc images over the full range of angles of incidence from 0° (normal incidence) to 70°, the struts push the corners up and down by up to 17 mm. A reflectometry metrology system has been used to set the 58 adjustment screws for the initial shape to an accuracy of ≤ 0.6 mrad, and to measure the accuracy of the different twisted shapes. The prototype will be tested at NSTTF early next year.

14 SOLAR ENERGY↗