Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “setup”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

TH-CD-209-04: Fuzzy Robust Optimization in Intensity-Modulated Proton Therapy Planning to Account for Range and Patient Setup Uncertainties

Purpose: We propose to apply a robust optimization model based on fuzzy-logic constraints in the intensity-modulated proton therapy (IMPT) planning subject to range and patient setup uncertainties. The purpose is to ensure the plan robustness under uncertainty and obtain the best trade-off between tumor dose coverage and organ-at-risk(OAR) sparing. Methods: Two IMPT plans were generated for 3 head-and-neck cancer patients: one used the planning target volume(PTV) method; the other used the fuzzy robust optimization method. In the latter method, nine dose distributions were computed - the nominal one and one each for ±3mm setup uncertainties along three cardinal axes and for ±3.5% range uncertainty. For tumors, these nine dose distributions were explicitly controlled by adding hard constraints with adjustable parameters. For OARs, fuzzy constraints that allow the dose to vary within a certain range were used so that the tumor dose distribution was guaranteed by minimum compromise of that of OARs. We rendered this model tractable by converting the fuzzy constraints to linear constraints. The plan quality was evaluated using dose-volume histogram(DVH) indices such as tumor dose coverage(D95%), homogeneity(D5%-D95%), plan robustness(DVH band at D95%), and OAR sparing like D1% of brain and D1% of brainstem. Results: Our model could yield clinically acceptable plans. The fuzzy-logic robust optimization method produced IMPT plans with comparable target dose coverage and homogeneity compared to the PTV method(unit: Gy[RBE]; average[min, max])(CTV D95%: 59 [52.7, 63.5] vs 53.5[46.4, 60.1], CTV D5% - D95%: 11.1[5.3, 18.6] vs 14.4[9.2, 21.5]). It also generated more robust plans(CTV DVH band at D95%: 3.8[1.2, 5.6] vs 11.5[6.2, 16.7]). The parameters of tumor constraints could be adjusted to control the tradeoff between tumor coverage and OAR sparing. Conclusion: The fuzzy-logic robust optimization generates superior IMPT with minimum compromise of OAR sparing. This research was supported by the National Cancer Institute Career Developmental Award K25CA168984, by the Fraternal Order of Eagles Cancer Research Fund Career Development Award, by The Lawrence W. and Marilyn W. Matteson Fund for Cancer Research, by Mayo Arizona State University Seed Grant, and by The Kemper Marley Foundation. eRA Person ID(s) for the Principal Investigator: 11017970 (Research Supported by National Institutes of Health)

60 APPLIED LIFE SCIENCES↗

Interferometric studies of the radiation wave front on the Luch setup

A radial shear interferometer for studying the shape of the wave front and aberrations of the optical system of the Luch setup were designed and created. To improve the interferometric pattern, the interferometer was simulated numerically by using the Fresnel software package. The parameters of the interferometer were optimized. The interferometer allows one to record interferograms of pulsed radiation at the first and second harmonics of a neodymium laser, as well as of continuous IR radiation with a short coherence length. A new method was developed for recovering the wave front by using the WinFringe software for interferograms with a reference front. Aberrations introduced by different parts and the entire optical system of the setup were measured. The wave fronts of the first and second harmonics obtained in full-scale experiments are presented. The experimental results agree with the radiation divergence measured by other methods.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Setup for Measuring the Thermoelectric Properties of Ultrathin Wires

An experimental setup is developed to measure the thermoelectric properties of semiconductor nanowires with diameters of up to 5 nm in dielectric matrices. This setup makes it possible to measure the electrical resistance and thermoelectric power of nanostructured samples in the temperature range of 77–400 K.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Experimental Setup for Neutron Lifetime Measurements with a Large Gravitational Trap at Low Temperatures

Currently the most accurate measurements of neutron lifetime are being performed at the Petersburg Nuclear Physics Institute with ultracold neutrons (UCNs) stored in a gravitational trap. A modified setup with a large gravitational trap and cooling to 10–15 K is presented. The results of measurements of temperature dependence of UCN losses in collisions with walls, which were coated with a perfluorinated grease (Fomblin UT 18), at 300–77 K, are detailed. The probable heat inflow to the trap is estimated, and the feasibility of cooling to indicated temperatures in experiments with the modified setup is demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of longitudinal displacement using lateral shearing cyclic path optical configuration setup and phase shifting interferometry

We present a technique for the measurement of longitudinal displacement using a lateral shearing cyclic path optical configuration (CPOC) setup and phase shifting interferometry. In the technique, a plane mirror mounted on a linear translation stage, placed slightly away from the focal plane of a lens, introduces a longitudinal focal shift to the incident focusing beam. The resulting spherical wavefront emerging from the lens is sheared into two orthogonally polarized beams using the CPOC setup. By applying polarization phase shifting interferometry (PPSI), the longitudinal focal shift of the beam focus is calculated by determining the slope of the optical path difference variation between the sheared beams. Similarly, the additional focal shift introduced due to longitudinal translation of the mirror, by an unknown amount, is determined using PPSI. Half of the difference between the two longitudinal focal shifts measured gives the longitudinal displacement of the mirror. The technique can be used for an extended range of distance measurement. The novelty of the technique is the introduction of CPOC for the distance measurement. The advantages of the technique compared to other related methods are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spectroscopic setup for submicrometer-resolution mapping of low-signal absorption and luminescence using photothermal heterodyne imaging and photon-counting techniques

A spectroscopic setup that enables one to map the absorption and photoluminescence with submicrometer spatial resolution and high sensitivity is described. Here a photothermal heterodyne imaging pump/probe technique is employed for absorption mapping, and low-signal, spatially resolved photoluminescence is recorded using photon counting. High-spatial-resolution mapping is accomplished by using high-numerical-aperture microscope objective focusing laser beams (pump and probe) into a submicrometer spot and raster-scanning sample mounted on the nanopositioning translation stage. Performance of the setup is illustrated by mapping absorption and luminescence of the hafnium oxide film with embedded hafnium nanoparticles and multilayer dielectric grating. In both cases submicrometer spatial resolution is demonstrated and possible physical mechanisms leading to image contrast on a submicrometer scale is discussed

47 OTHER INSTRUMENTATION↗

First Measurements and Results With a Stretched Wire Test Setup

The LINAC Coherent Light Source [LCLS] is a free electron laser, designed to produce high brilliant X-ray beams using Self Amplified Spontaneous Emission [SASE]. Due to the physics of SASE, the electron beam has to be held very precisely on the same trajectory as the X-ray light beam generated by the undulator magnets. To optimize the SASE output, trajectory deviations between both beams have to be minimized to a few micrometers along the entire undulator section and held stable over the time period between beam-based-alignment processes. Consequently, extremely high position stability of all magnets in the undulator section is required to operate the LCLS successfully. The knowledge of any magnet movement exceeding few micrometers during periods of several weeks is essential for efficient X-ray generation. A well known principle of monitoring transverse component positions along beam lines is the application of stretched wires, associated with suitable wire position sensors and electronics. The particular challenge at LCLS is the required wire system performance in conjunction with the length of the undulator section and the large number of monitors. Verification of system stability and resolution under real conditions is the primary goal of this test setup. A stretched wire test setup has been implemented to gain experience for the final design of a wire system, which will meet the position monitoring requirements in the LCLS undulator section. The report briefly introduces the system's architecture and describes first measurements and results.

43 PARTICLE ACCELERATORS↗

Majorana Thermosyphon Prototype Experimental Setup

This report presents the experimental setup of Pacific Northwest National Laboratory’s MAJORANA DEMONSTRATOR thermosyphon prototype cooling system. A nitrogen thermosyphon prototype of such a system has been built and tested at PNNL. This document presents the experimental setup of the prototype that successfully demonstrated the heat transfer performance of the system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

LANL Problem Setup [Slides]

This talk is a roughly 20-30 minute presentation to be given during the meshing and parallel partitioning session of the NNSA/CEA Computing Sciences Collaboration Workshop in Sedona on June 7, 2011. The purpose of the talk is to introduce the participants to the types of geometry, meshing, and general problem setup issues of interest to the ASC program at LANL and specifically those of interest to the ASC Simulation Setup Project. The presentation the discussions be focused on areas of possible research collaboration among LANL, LLNL, SNL, and the CEA.

97 MATHEMATICS AND COMPUTING↗

Development and design of a multi-column experimental setup for Kr/Xe separation

As a precursor to FY-15 Kr/Xe separation testing, design modifications to an existing experimental setup are warranted. The modifications would allow for multi-column testing to facilitate a Xe separation followed by a Kr separation using engineered form sorbents prepared using an INL patented process. A new cooling apparatus capable of achieving test temperatures to -40° C and able to house a newly designed Xe column was acquired. Modifications to the existing setup are being installed to allow for multi-column testing and gas constituent analyses using evacuated sample bombs. The new modifications will allow for independent temperature control for each column enabling a plethora of test conditions to be implemented. Sample analyses will be used to evaluate the Xe/Kr selectivity of the AgZ-PAN sorbent and determine the Kr purity of the effluent stream following Kr capture using the HZ-PAN sorbent.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Search for hybrid baryons with CLAS12 experimental setup

It is crucial to study the meson electroproduction in the kinematic region dominated by the formation of resonances. CLAS12 setup in Hall B at Jefferson Lab is particularly suitable for this task, since it is able to detect scattered electrons at low polar angles thanks to the Forward Tagger (FT) component. The process that we propose to study is ep → e'K + Λ, where the electron beam will be provided by the CEBAF accelerator with energies of 6.6, 8.8, and 11 GeV. This thesis work describes the setup and calibration of the FT calorimeter and the studies related to the search of hybrid baryons through the measurement of the K + Λ electroproduction cross section.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Decrease time-to-solution through improved linear-system setup and solve

The goal of the ExaWind project is to enable predictive simulations of wind farms composed of many MW-scale turbines situated in complex terrain. Predictive simulations will require computational fluid dynamics (CFD) simulations for which the mesh resolves the geometry of the turbines, and captures the rotation and large deflections of blades. Whereas such simulations for a single turbine are arguably petascale class, multi-turbine wind farm simulations will require exascale-class resources. The primary code in the ExaWind project is Nalu, which is an unstructured-grid solver for the acoustically-incompressible Navier-Stokes equations, and mass continuity is maintained through pressure projection. The model consists of the mass-continuity Poisson-type equation for pressure and a momentum equation for the velocity. For such modeling approaches, simulation times are dominated by linear-system setup and solution for the continuity and momentum systems. For the ExaWind challenge problem, the moving meshes greatly affect overall solver costs as re-initialization of matrices and re-computation of preconditioners is required at every time step We describe in this report our efforts to decrease the setup and solution time for the mass-continuity Poisson system with respect to the benchmark timing results reported in FY18 Q1. In particular, we investigate improving and evaluating two types of algebraic multigrid (AMG) preconditioners: Classical Ruge-Stfiben AMG (C-AMG) and smoothed-aggregation AMG (SA-AMG), which are implemented in the Hypre and Trilinos/MueLu software stacks, respectively. Preconditioner performance was optimized through existing capabilities and settings.

17 WIND ENERGY↗

Setup and Testing of the RS105 Wire Array Pulser

The report covers the RS105 Wire Array Pulser testbed. The setup of the wire array at Reapplication, building 996, is laid out. Setup instructions are provided. Details of the commissioning test are given. Measurement data from the commissioning test shows the field output of the array exceeds 50 kV/m and that tuning the pulser output with a peaking switch can provide a rise time of ~2.3 ns and a pulse width of ~23 ns. The field levels and timeframes shown are within the tolerance conditions of

42 ENGINEERING↗

Optimized cryogenic setup for microwave loss characterization of superconducting coaxial cables

As superconducting quantum systems scale up to enable applications like large-scale quantum computing, challenges such as fabrication yield, wiring complexity, and microwave crosstalk drive the need for high-fidelity, low-loss, modular interconnects. In recent experiments, the performance of these interconnects is often limited by cable loss, a factor that becomes even more critical as we aim for higher fidelity operations and connect increasingly coherent modules. In this talk, we present our cryogenic microwave loss characterization setup, carefully designed to minimize losses external to the coaxial cables under test. We also share results for several commercially-available superconducting cables measured with this setup and briefly discuss our ongoing efforts to develop custom coaxial cables capable of achieving state-of-the-art performance.

Vallières, André [Northwestern U.]↗

Optimized cryogenic setup for microwave loss characterization of superconducting coaxial cables

As superconducting quantum systems scale up to enable applications like large-scale quantum computing, challenges such as fabrication yield, wiring complexity, and microwave crosstalk drive the need for high-fidelity, low-loss, modular interconnects. In recent experiments, the performance of these interconnects is often limited by cable loss, a factor that becomes even more critical as we aim for higher fidelity operations and connect increasingly coherent modules. In this talk, we present our cryogenic microwave loss characterization setup, carefully designed to minimize losses external to the coaxial cables under test. We also share results for several commercially-available superconducting cables measured with this setup and briefly discuss our ongoing efforts to develop custom coaxial cables capable of achieving state-of-the-art performance.

Vallières, André [Northwestern U.]↗

Benchtop-Scale High Temperature Molten Salt Electrochemical Reactors: Experimental Setup and Considerations

Molten salt electrochemical reduction (MSER) is the dominant production method for aluminum and titanium, and emerging technologies for producing other commodity metals with these highly electrified techniques have demonstrated promising results. However, the scale up of MSER of materials such as iron and silicon are limited by the challenging issues of materials compatibility and impurity control. This work describes an experimental MSER setup using both chloride and carbonate salts. This setup is designed for operations outside of a glovebox, which is practical from an industrial perspective, but creates unique challenges. This work serves as a practical guide to discuss some key operational difficulties such as temperature control, air and humidity, material compatibility, developing strong electrical measurements and techniques, and safety.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of Centralized Model-Based FLISR in a Lab Setup: Preprint

Utilities are installing advanced distribution management systems (ADMS) around the globe to improve the sensing and control of distribution systems. ADMS is becoming a critical component to improve the resiliency and reliability of distribution systems. These management systems host a multitude of applications that can be used to sense, control, and operate distribution systems. Fault location, isolation, and service restoration (FLISR) is one of the ADMS applications that is critical to improving resilience during fault conditions. FLISR applications use smart, controllable devices that are installed in the distribution system for FLISR operation. These controllable devices include distributed energy resources (DER) and reclosers. Evaluating such ADMS applications before installation in the field can help de-risk the field implementation and avoid costly failures in the field. This paper presents a background on experimental setup that are typically used to evaluate ADMS applications. This is followed by briefly presenting the setup used to evaluate the FLISR application in an off-the-shelf ADMS tool. Finally, results from the evaluation experiments are presented.

94 GMLC - Grid Modernization Laboratory Consortium↗