Processing of Nanosensors Using a Sacrificial Template Approach

A new microsensor fabrication approach has been demonstrated based upon the use of nanostructures as templates. The fundamental idea is that existing nanostructures, such as carbon nano tubes or biological structures, have a material structure that can be used advantageously in order to provide new sensor systems but lack the advantages of some materials to, for example, operate at high temperatures. The approach is to start with a template using nanostructures such as a carbon nanotube. This template can then be coated by an oxide material with higher temperature capabilities. Upon heating in air, the carbon nanotube template is burned off, leaving only the metal oxide nanostructure. The resulting structure has a combination of the crystal structure and surface morphology of the carbon nanotube, combined with the material durability and hightemperature- sensing properties of the metal oxide. Further, since the metal oxide nanocrystals are deposited on the carbon nanotube, after burn-off what is left is a metal oxide porous nanostructure. This makes both the interior and the exterior of this nano structured sensor available for gas species detection. This, in effect, increases the surface area available for sensing, which has been shown in the past to significantly increase sensor performance.

Biaggi-Labiosa, Azlin M.↗

Real-Time, Non-Intrusive Detection of Liquid Nitrogen in Liquid Oxygen at High Pressure and High Flow

An integrated fiber-optic Raman sensor has been designed for real-time, nonintrusive detection of liquid nitrogen in liquid oxygen (LOX) at high pressures and high flow rates in order to monitor the quality of LOX used during rocket engine ground testing. The integrated sensor employs a high-power (3-W) Melles Griot diode-pumped, solid-state (DPSS), frequency-doubled Nd:YAG 532- nm laser; a modified Raman probe that has built-in Raman signal filter optics; two high-resolution spectrometers; and photomultiplier tubes (PMTs) with selected bandpass filters to collect both N2 and O2 Raman signals. The PMT detection units are interfaced with National Instruments Lab- VIEW for fast data acquisition. Studies of sensor performance with different detection systems (i.e., spectrometer and PMT) were carried out. The concentration ratio of N2 and O2 can be inferred by comparing the intensities of the N2 and O2 Raman signals. The final system was fabricated to measure N2 and O2 gas mixtures as well as mixtures of liquid N2 and LOX

Singh, Jagdish P.↗

Dynamic Range and Sensitivity Requirements of Satellite Ocean Color Sensors: Learning from the Past

Sensor design and mission planning for satellite ocean color measurements requires careful consideration of the signal dynamic range and sensitivity (specifically here signal-to-noise ratio or SNR) so that small changes of ocean properties (e.g., surface chlorophyll-a concentrations or Chl) can be quantified while most measurements are not saturated. Past and current sensors used different signal levels, formats, and conventions to specify these critical parameters, making it difficult to make cross-sensor comparisons or to establish standards for future sensor design. The goal of this study is to quantify these parameters under uniform conditions for widely used past and current sensors in order to provide a reference for the design of future ocean color radiometers. Using measurements from the Moderate Resolution Imaging Spectroradiometer onboard the Aqua satellite (MODISA) under various solar zenith angles (SZAs), typical (L(sub typical)) and maximum (L(sub max)) at-sensor radiances from the visible to the shortwave IR were determined. The Ltypical values at an SZA of 45 deg were used as constraints to calculate SNRs of 10 multiband sensors at the same L(sub typical) radiance input and 2 hyperspectral sensors at a similar radiance input. The calculations were based on clear-water scenes with an objective method of selecting pixels with minimal cross-pixel variations to assure target homogeneity. Among the widely used ocean color sensors that have routine global coverage, MODISA ocean bands (1 km) showed 2-4 times higher SNRs than the Sea-viewing Wide Field-of-view Sensor (Sea-WiFS) (1 km) and comparable SNRs to the Medium Resolution Imaging Spectrometer (MERIS)-RR (reduced resolution, 1.2 km), leading to different levels of precision in the retrieved Chl data product. MERIS-FR (full resolution, 300 m) showed SNRs lower than MODISA and MERIS-RR with the gain in spatial resolution. SNRs of all MODISA ocean bands and SeaWiFS bands (except the SeaWiFS near-IR bands) exceeded those from prelaunch sensor specifications after adjusting the input radiance to L(sub typical). The tabulated L(sub typical), L(sub max), and SNRs of the various multiband and hyperspectral sensors under the same or similar radiance input provide references to compare sensor performance in product precision and to help design future missions such as the Geostationary Coastal and Air Pollution Events (GEO-CAPE) mission and the Pre-Aerosol-Clouds-Ecosystems (PACE) mission currently being planned by the U.S. National Aeronautics and Space Administration (NASA).

chlorophyll fluorescence↗

The High Definition Earth Viewing (HDEV) Payload

The High Definition Earth Viewing (HDEV) payload enables long-term experimentation of four, commercial-of-the-shelf (COTS) high definition video, cameras mounted on the exterior of the International Space Station. The payload enables testing of cameras in the space environment. The HDEV cameras transmit imagery continuously to an encoder that then sends the video signal via Ethernet through the space station for downlink. The encoder, cameras, and other electronics are enclosed in a box pressurized to approximately one atmosphere, containing dry nitrogen, to provide a level of protection to the electronics from the space environment. The encoded video format supports streaming live video of Earth for viewing online. Camera sensor types include charge-coupled device and complementary metal-oxide semiconductor. Received imagery data is analyzed on the ground to evaluate camera sensor performance. Since payload deployment, minimal degradation to imagery quality has been observed. The HDEV payload continues to operate by live streaming and analyzing imagery. Results from the experiment reduce risk in the selection of cameras that could be considered for future use on the International Space Station and other spacecraft. This paper discusses the payload development, end-to- end architecture, experiment operation, resulting image analysis, and future work.

Muri, Paul↗

Mapping of the Resistance of a Superconducting Transition Edge Sensor as a Function of Temperature, Current, and Applied Magnetic Field

We have measured the resistance R (T, I, B(sub ext) of a superconducting transition edge sensor over the entire transition region on a fine scale, producing a four-dimensional map of the resistance surface. The dimensionless temperature and current sensitivities (alpha equivalence partial derivative log R/partial derivative log T|(sub I) and beta equivalence partial derivative log R/partial derivative log I|(sub T) of the TES resistance have been determined at each point. alpha and beta are closely related to the sensor performance, but show a great deal of complex, large amplitude fine structure over large portions of the surface that is sensitive to the applied magnetic field. We discuss the relation of this structure to the presence of Josephson weak link fringes.

Zhang, Shou↗

Low-Power, Chip-Scale, CO2 Gas Sensors for Spacesuit Monitoring

N5 Sensors, Inc. and NASA through a STTR program are jointly developing ultra-small, low-power carbon dioxide (CO2) gas sensors, suited for monitoring CO2 levels inside the spacesuits. Due to the unique environmental conditions within the spacesuits, such as high humidity, large temperature and operating pressure swings, measurement of key gases relevant to astronaut's safety and health such as carbon dioxide, is quite challenging. Conventional non-dispersive infrared absorption based CO2 sensors cannot be effectively implemented inside the spacesuits due to their sizes, weights, and power constraints. Metal-oxide based sensors have been effectively miniaturized for several applications, however detection of CO2 utilizing metal-oxide based sensors is challenging due to the chemical inertness and high stability of CO2 at room-temperatures. To mitigate these limitations, unique chip-scale, nanoengineered chemiresistive gas-sensing architecture has been developed - to allow the Metal-oxide sensors to operate in space-suite environmental conditions. Unique design combining the selective adsorption properties of the nanophotocatalytic clusters of metal-oxides and metals, provides selective detection of CO2 in high relative humidity conditions. All electronic design provides a compact and low-power solution, which can be implemented for multipoint detection of CO2 inside the spacesuits. This paper will describe a novel approach in refining the sensor architecture, development of new photocatalytic material for better sensor performance.

Thomson, Brian↗

Architecture Options for Navigation in Cislunar Space for Human Landing System Vehicles

Initial vehicles destined for the moon as part of the Human Landing Systems have tight requirements in terms of autonomous precision landing. This results in complex multi-element sensor suites and complex onboard fault redundancy approach. As additional infrastructure is placed into cislunar space, these requirements for onboard systems can be relaxed by relying on system-level observations. This paper provides results of studies supporting Human Landing Risk assessments identifying sensitivities to onboard sensor performance and describes options to support the architectural using a variety of infrastructure approaches. The results are applied to lunar cruise, ascent, and descent scenarios.

Evan Anzalone↗

Comprehensive Comparison of Airborne and Spaceborne SAR and LiDAR Estimates of Forest Structure in the Tallest Mangrove Forest on Earth

A recent suite of new global-scale satellite sensors and regional-scale airborne campaigns are providing a wealth of remote sensing data capable of dramatically advancing our current understanding of the spatial distribution of forest structure and carbon stocks. However, a baseline for forest stature and biomass estimates has yet to be established for the wide array of available remote sensing products. At present, it remains unclear how the estimates from these sensors compare to one another in terrestrial forests, with a clear dearth of studies in high carbon density mangrove ecosystems. In the tallest mangrove forest on Earth (Pongara National Park, Gabon), we leverage the data collected during the AfriSAR campaign to evaluate 17 state-of-the-art sensor data products across the full range of height and biomass known to exist globally in mangrove forest ecosystems, providing a much-needed baseline for sensor performance. Our major findings are: (Houghton, Hall, Goetz) height estimates are not consistent across products, with opposing trends in relative and absolute errors, highlighting the need for an adaptive approach to constraining height estimates (Panet al., 2011); radar height estimates had the lowest calibration error and bias, with further improvements using LiDAR fusion (Bonan, 2008); biomass variability and uncertainty strongly depends on forest stature, with variation across products increasing with canopy height, while relative biomass variation was highest in low-stature stands (Le Quéréet al., 2017); a remote sensing product's sensitivity to variations in canopy structure is more important than the absolute accuracy of height estimates (Mitchardet al., 2014); locally-calibrated area-wide totals are more representative than generalized global biomass models for high-precision biomass estimates. The findings presented here provide critical baseline expectations for height and biomass predictions across the full range of mangrove forest stature, which can be directly applied to current (TanDEM-X, GEDI, ICESat-2) and future (NISAR, BIOMASS) global-scale forest monitoring missions.

Atticus E.L. Stovall↗

Latest Development in Radiative Transfer Models and Retrieval Algorithms Using Principal Components

The radiative transfer model (RTMs) has a wide range of applications in satellite remote sensing and atmospheric radiation applications. However, millions of line-by-line (LBL) radiative transfer calculations at fine monochromatic frequencies are needed in order to properly calculate spectral contributions of water vapor and trace gases in the atmosphere in infrared and solar spectral regions. Therefore, fast and accurate RTMs are needed to efficiently process large amount of satellite data. A Principal Component-based Radiative Transfer Model (PCRTM) was first developed in 2004 at NASA Langley Research Centre to fulfil this need. By using PC-compression, one can reduce the data dimension significantly while maintaining original information content. The PCRTM can directly compute PC-scores and their derivatives with respect to retrieved parameters. The PCRTM can simulate the top-of-atmosphere (TOA) radiance or reflectance spectra from 0.250 µm (400000 cm-1) to 2000 µm (50 cm-1) with several orders of magnitude faster speed as compared to a LBL RTM. It is also extremely accurate compared to LBL RTM benchmarks (0.03 K RMS error in IR and 0.05% in solar). The PCRTM model has been developed for hyperspectral sensors such as AIRS, CrIS, IASI, NAST-I, SHIS, FIRST, and CLARREO-IR in thermal IR spectral region and CLARREO-Solar, CPF, TEMPO, EMIT, OMI, and SCIAMACHY in solar spectral region. The PCRTM accuracy has been demonstrated via RTM intercomparisons and with real satellite observations from AIRS, CrIS, IASI, SCHIAMACHY, and EMIT etc. In this presentation, we will describe two PCRTM-based inversion algorithms to retrieve atmospheric temperature, water vapor, and trace gas profiles, as well as cloud and surface properties from hyperspectral sounders such as AIRS, CrIS, IASI, and NAST-I. The first one is called Single Fieldof-view Sounder Atmospheric Product (SiFSAP) algorithm. It provides L2 products with 9-times higher area spatial resolution as compared to current cloud-clearing sounder algorithms. The SiFSAP L2 and L3 products are available at NASA's Goddard Earth Sciences Data and Information Services Center (GES DISC) for public access. The second inversion algorithm is called Climate Fingerprinting Atmospheric Product (ClimFiSP) algorithm. It is designed to produce high quality climate products (trends, anomalies, daily, and monthly profiles of temperature, water vapor, traces, clouds, and surface properties) from multiple satellite sensors such AIRS on Aqua and CrIS on multiple satellites. This product will be available at NASA GES DISC later this year. The PCRTMbased high fidelity simulators for CLARREO and CPF have been used for sensor performance trade studies, algorithm development, and inter-satellite calibrations. We have also used PCRTM generated TOA radiance spectra to train an AI-based algorithm and successfully retrieved cloud properties from EMIT solar hyperspectral imagers.

PCRTM↗

Effect of hand-based sensors on manipulator control performance

The effect of hand based sensors (e.g tactile, force, and proximity sensors) on the performance of manipulator control is discussed. A brief overview is presented on various experimental hand based information systems which provide the manipulator controller some nonvisual awareness of the task environment. It is established that differences in manipulator task categories and motion phases require different hand based information systems to cope with control performance requirements.

Bejczy, A. K.↗

Holt film wall shear instrumentation for boundary layer transition research

Measurements of the performance of hot-film wall-shear sensors were performed to aid development of improved sensors. The effect of film size and substrate properties on the sensor performance was quantified through parametric studies carried out both electronically and in a shock tube. The results show that sensor frequency response increases with decreasing sensor size, while at the same time sensitivity decreases. Substrate effects were also studied, through parametric variation of thermal conductivity and heat capacity. Early studies used complex dual-layer substrates, while later studies were designed for both single-layer and dual-layer substrates. Sensor failures and funding limitations have precluded completion of the substrate thermal-property tests.

Schneider, Steven P.↗

Michigan experimental multispectral mapping system: A description of the M7 airborne sensor and its performance

The development and characteristics of a multispectral band scanner for an airborne mapping system are discussed. The sensor operates in the ultraviolet, visual, and infrared frequencies. Any twelve of the bands may be selected for simultaneous, optically registered recording on a 14-track analog tape recorder. Multispectral imagery recorded on magnetic tape in the aircraft can be laboratory reproduced on film strips for visual analysis or optionally machine processed in analog and/or digital computers before display. The airborne system performance is analyzed.

Hasell, P. G., Jr.↗

Automatic Docking System Sensor Design, Test, and Mission Performance

The Video Guidance Sensor is a key element of an automatic rendezvous and docking program administered by NASA that was flown on STS-87 in November of 1997. The system used laser illumination of a passive target in the field of view of an on-board camera and processed the video image to determine the relative position and attitude between the target and the sensor. Comparisons of mission results with theoretical models and laboratory measurements will be discussed.

Jackson, John L.↗

Demonstration of Stereo Vision for Deorbit Descent and Landing

Planetary landers need to reduce velocity at low altitude for soft landing. Traditionally, estimating velocity and altitude has been performed with radar sensors whose performance meets the specific mission needs. There are not very many options for these sensors and they are difficult to include in a flight system either due to obsolescence, prohibitive cost or difficulty in accommodation. Recently, alternative sensing modalities are being pursued including Doppler LiDAR and vision. This paper describes results from a recent helicopter field test of a binocular stereo vision system for deorbit descent and landing applications. The system consisted of two 18.6 ̊ field of view cameras mounted 1.7m apart. Post processing of the images showed ranging accuracy better than 1% up to 500mand 17 cm/s velocimetry accuracy at 37m. For a flight system these images could be input into an FPGA-based processor which processes dense stereo and visual odometry in less than 1 second to achieve the stereo ranging frame rates required for soft landing. When coupled with vision based Terrain Relative Navigation this stereo system enables landing accuracies on the order of 10m.

Sternberg, David C.↗

Effect of hand-based sensors on manipulator control performance

Manipulator task categories and motion phases require various hand-based information systems to meet the control performance requirements. The effect of proximity, tactile and force/torque sensors on the performance of remote manipulator control is discussed. An overview is presented on various experimental hand-based information systems which provide the manipulator controller some non-visual 'awareness' of the task environment. The rest of the paper describes and evaluates various control experiments performed at JPL using hand-mounted proximity sensors to guide and control hand motion near solid objects.

Bejczy, A. K.↗

Design and Performance Evaluation of Sensors and Actuators for Advanced Optical Systems

Current state-of-the-art commercial sensors and actuators do not meet many of NASA s next generation spacecraft and instrument needs. Nor do they satisfy the DoD needs for satellite missions, especially micro/nano satellite missions. In an effort to develop advanced optical devices and instruments that meet mission requirements, NASA Langley recently completed construction of a new cleanroom housing equipment capable of fabricating high performance active optic and adaptive optic technologies including deformable mirrors, reconfigurable lenses (both refractive and diffractive), spectrometers, spectro-polarimeters, tunable filters and many other active optic devices. In addition to performance, these advanced optic technologies offer advantages in speed, size, weight, power consumption, and radiation tolerance. The active optic devices described in this paper rely on birefringent liquid crystal materials to alter either the phase or the polarization of the incoming light. Design considerations and performance evaluation results for various NASA applications are presented. Applications presented will include large space telescopes, optical communications, spacecraft windows, coronagraphs, and star trackers. Keywords: Photonics, Adaptive Optics, Tunable Filters, MEMs., MOEMs, Coronagraph, Star Tracker

Clark, Natalie↗