Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “scintillator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Observations regarding inclusions in the growth of $\mathrm{Cs}$ 2 $\mathrm{HfCl}$ 6 single crystal scintillators

Cs 2 HfCl 6 (CHC) is a promising high density, high-Z, non-hygroscopic, and high energy resolution scintillator. In CHC, many crystals have CsCl inclusions that form during growth. In this paper, we investigate how material synthesis, growth rate, and thermal gradient affect the formation of CsCl inclusions and their effect on scintillation performance. First, precursor material was made through a methanol synthesis process both with and without hydrochlorination. Next, five crystals were grown using Bridgman method, at growth rates of 1 or 0.5 mm/h, and thermal gradients of 21 °C or 34 °C per millimeter. The best overall performance was observed in a 22 mm diameter crystal produced using hydrochlorination which was grown at 1 mm/h in a thermal gradient of 34 °C per millimeter. It had a light yield of 36,000 photons/MeV and an energy resolution of 4.0% at 662 keV. Finally, we have also shown that poorer scintillation performance in the lower quality crystals is most likely due to reduced light collection caused by a higher concentration of inclusions.

36 MATERIALS SCIENCE↗

Crystal growth of new high light yield halide perovskite scintillator RbSrI 3

X-ray radiography systems are a key national security technology enabling non-invasive cargo screening. However, the scintillators currently used in these systems have limitations in performance that prompt research for new suitable materials. Here, in this work, crystal growth, physical properties, and optical and scintillation properties of a new halide perovskite scintillator RbSrI 3 were investigated for the first time. The melting point was determined to be 453 °C. Divalent europium and ytterbium were investigated as potential luminescent activators. Light yield and energy resolution of RbSrI 3 :Eu 5 mol% was 78,700 ph/MeV and 2.8 % at 662 keV, and that of RbSrI 3 :Yb 0.5 mol% was 24,000 ph/MeV and 4.9 % at 662 keV.

36 MATERIALS SCIENCE↗

Boron-loaded organic glass scintillators

Herein we report the progress towards an organic glass scintillator with fast and thermal neutron sensitivity providing “triple” pulse shape discrimination (PSD) through the inclusion of a boron-incorporated aromatic molecule. Here, the commercially available molecule 2-(p-tolyl)-1,3,2-dioxaborinane (TDB) can be readily synthesized in one step using inexpensive materials and incorporated into the organic glass scintillator at 20% by weight or 0.25% 10 B by mass. In addition, we demonstrate that TDB can be easily scaled up and formulated into organic glass scintillator samples to produce a thermal neutron capture signal with a light yield equivalent to 120.4 ± 3.7 keVee, which is the highest value reported in the literature to date.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

How silicon and boron dopants govern the cryogenic scintillation properties of N -type GaAs

This work is the first report describing how the concentrations of silicon and boron govern the cryogenic scintillation properties of n-type GaAs. It shows that valence band holes are promptly trapped on radiative centers and then combine radiatively with silicon donor band electrons at rates that increase with the density of free carriers. It also presents the range of silicon and boron concentrations needed for efficient light emission under X-ray excitation, which along with its low band gap and apparent absence of afterglow, make scintillating GaAs suitable for the detection of rare, low-energy electronic excitations from interacting dark matter particles. A total of 29 samples from four different suppliers were studied. Luminosities and timing responses were measured for the four principal emission bands centered at 860, 930, 1070, and 1335 nm, and for the total emissions. Excitation pulses of 40 kVp X-rays were provided by a light-excited X-ray tube driven by an ultra-fast laser. Scintillation emissions from 800 to 1350 nm were measured using an InGaAs photomultiplier. Within the concentration ranges of free carriers from 2 x 10 16 /cm 3 to 6 x 10 17 /cm 3 and boron from 1.5 × 10 18 /cm 3 to 6 x 10 18 /cm 3 , nine samples have luminosities > 70 photons/keV and two have luminosities > 110 photons/keV. Other samples in that range have lower luminosities due to higher concentrations of non-radiative centers. The decay times decrease by typically a factor of ten with increasing free carrier concentrations from 10 17 /cm 3 to 2 x 10 18 /cm 3 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhanced Neutron and γ-Ray Detection via 6 Li Substitution in Undoped and Tl-Doped Zero-Dimensional Perovskite Cs 3 Cu 2 I 5 Scintillators

Radiation detectors are crucial in a wide variety of research and commercial applications, such as oil and gas exploration, medical imaging, nuclear nonproliferation, and homeland security. Neutron and gamma-ray detectors are fundamental components in portal monitors at ports and border crossings, bolstering national security against radiological threats. This study presents a dual-mode scintillator, undoped and Tl-doped 6 Li-Cs 3 Cu 2 I 5 , and demonstrates its potential as a promising material for simultaneous thermal neutron and gamma-ray detection. We explore the Bridgman growth of both undoped and thallium doped Li → Cu and Li → Cs substitutional systems with various Li doping levels and assess their impact on scintillation properties. Under 662 keV gamma-ray excitation, the undoped crystals had light yields up to 35,900 ph/MeV, with energy resolutions down to 4.5%. The Tl-doped crystals performed better than the undoped crystals with light yields peaking at 65,900 ph/MeV and energy resolutions as low as 3.5%. When exposed to a moderated 252 Cf excitation source, our crystals had light yields between 102,900 and 167,200 photons per thermal neutron capture, with a full energy thermal neutron peak reaching 3 MeV in gamma equivalent energy. Pulse shape discrimination studies reveal well-separated gamma and neutron events, resulting in Figure-Of-Merit (FOM) as high as 3.7. Furthermore, these findings highlight the potential of Li-doped Cs 3 Cu 2 I 5 as a viable candidate for next-generation dual-mode scintillators.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fast Rossi-alpha Measurements of Plutonium Using Organic Scintillators

In this work, Rossi-alpha measurements were simultaneously performed with a 3 He-based detection system and an organic scintillator-based detection system. The assembly is 15 kg of plutonium (93 wt% 239 Pu) reflected by copper and moderated by lead. The goal of Rossi-alpha measurements is to estimate the prompt neutron decay constant, alpha. Simulations estimate $k_{eff}$ = 0:624 and α = 52:3 ± 2:5 ns for the measured assembly. The organic scintillator system estimated α = 47:4 ± 2:0 ns, having a 9.37% error (though the 1.09 standard deviation confidence intervals overlapped). The 3 He system estimated α = 37 μs. The known slowing down time of the 3 He system is 35-40 μs, which means the slowing down time dominates and obscures the prompt neutron decay constant. Subsequently, the organic scintillator system should be used for assemblies with alpha much less than 35 μs.

3He↗

Scintillator detector characterization for laser-driven proton beam imaging

The spatial resolution and imaging characteristics of plastic scintillators are characterized using laser-driven proton beams. Laser-driven proton beams typically have broad energy spectra and are accompanied by relativistic electrons and high-energy photons, both potentially contributing to background noise. Different types and thicknesses of Eljen Technology scintillators are compared to determine their intrinsic point spread function. Point-projection imaging of a mesh is used to compare the imaging resolution of the scintillator to the usual imaging detector, radiochromic film, and is found to be reasonably comparable and sufficient for many experimental applications.

47 OTHER INSTRUMENTATION↗

Proton damage in (Y,Lu,Gd) 3 (Al,Ga) 5 O 12 :Ce mixed garnet scintillators

Scintillators are vital components for nuclear instrumentation and its applications, including plasma diagnostics and imaging. As yields in controlled fusion experiments increase, the radiation tolerance of scintillator candidates for use in instrumentation is of particular importance. High radiation exposure can damage scintillating materials and alter the optical properties. The effects of radiation damage in Ce-doped mixed garnet ceramics over the compositional range (Y,Gd,Lu) 3 (Al,Ga) 5 O 12 are investigated using optical techniques. The samples were exposed to 200 keV protons to an accumulated fluence of 10 16 protons per square centimeter, then characterized using diffuse reflectance spectroscopy (DRS). DRS with visible light can assess the radiation tolerance of opaque poly-crystalline samples, which can be easily sintered from powders and thus offer distinct advantages in characterization compared to single crystals. Qualitative trends in induced absorption are presented as a function of composition, and the ideal cerium dopant concentration for Y 2 LuAl 5 O 12 is determined to be 0.60–0.75 mol.%.

47 OTHER INSTRUMENTATION↗

Nonlinear light-output calibration of the oxygenated xylene scintillators used in OMEGA neutron time-of-flight spectrometers

Neutron time-of-flight (nTOF) spectrometers are essential instruments for measuring and evaluating the performance of inertial confinement fusion implosions. The neutron spectrometers utilized for the OMEGA laser include two liquid-based scintillators, each consisting of a large volume filled with xylene that is coupled to four photomultiplier tubes. Analysis of the signal from these detectors requires detailed knowledge of the scintillator’s light output, which is needed to fit the nTOF spectrum, from which the neutron energy spectrum is informed. The light output is nonlinearly proportional to the neutron energy, which, in turn, affects the interpretation of the neutron energy spectrum from a TOF signal. A recent campaign on OMEGA was performed to calibrate the xylene detectors and infer the shape of the light-output curve. The campaign utilized materials with increasing Z placed in the OMEGA target chamber to initiate scattering events with the 14 MeV fusion neutrons. This process leads to the production of backscatter neutrons of varying energies that appear as peaks in the nTOF data. Simulations using a neutron transport code were combined with the measured deuterium–tritium neutron yields to calculate the expected backscattered neutron yields from the well-known scattering cross sections of each material. Furthermore, the neutron-energy dependent light output of the scintillator inferred from the experiment is compared to the light-output curve simulated with a neutron transport code for the following neutron energies: 1.5, 2.5, 6, and 14 MeV.

47 OTHER INSTRUMENTATION↗

Scintillation light detection in polycrystalline diamond using single photon detectors

Here, this study investigates the scintillation properties of polycrystalline diamond for particle detection applications, particularly in neutron and alpha radiation environments. Polycrystalline diamonds provide a cost-effective alternative to monocrystalline diamonds while retaining essential detection properties. Photoluminescence measurements were performed to analyze emission spectra, revealing distinct characteristics based on impurity content and crystallinity. Scintillation responses were assessed using Silicon Photomultipliers (SiPMs), demonstrating the capability of polycrystalline diamond powders to respond to alpha irradiation, albeit with reduced resolution compared to traditional scintillators. A prototype neutron detector was developed by combining diamond powder with neutron-sensitive 6 LiF, and its performance was evaluated through experimental testing and Geant4 simulations. The findings indicate that polycrystalline diamond-based detectors can achieve significant detection efficiency while remaining insensitive to gamma radiation, offering potential for portable neutron detection applications.

47 OTHER INSTRUMENTATION↗

Role of Lithium Codoping in Enhancing the Scintillation Yield of Aluminate Garnets

The aim of this work is to clarify the scintillation-yield enhancement in Lu YAG : Pr scintillators obtained by Li codoping via integrated study of the valence state of activators, the preferential site occupancy of Li codopants, and defect structures from experimental and theoretical insights. Here, with Li codoping, the light yield and energy resolution of 10 × 10 × 10 mm 3 Lu YAG : Pr samples are improved from 156000 to 248000 photons/MeV, and 5.3 to 4.3% at 662 keV,respectively.The optical absorption spectra indicate that Li codoping does not induce conversion of stable Pr 3 + to Pr 4 + in Lu YAG : Pr single crystals. Based on the formation energies of substitutional and interstitial Li sites using density-functional-theory (DFT) calculations and the 7 Li nuclear magnetic resonance results, it is shown that the Li ions prefer to dominantly occupy the fourfold coordinated interstitial sites and fourfold coordinated Al sites. The systematic analysis of thermoluminescence glow curves, positron annihilation lifetime spectroscopies, and defect formation energies derived from DFT calculations reveals that the concentration of isolated Lu and Al vacancies as dominant acceptor defects is reduced by Li codoping, whilst the shallow Li i interstitial defects and the deep V O oxygen vacancies are introduced simultaneously. We propose that the lowering of hole trapping at defects resulting from Li codoping contributes to the scintillation-yield enhancement.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Detection of uranium-photofission neutrons with a 4 He scintillation detector

The use of photon active interrogation to detect special nuclear material has held significant theoretical promise, as the interrogating source particles, photons, are fundamentally different from one of the main signatures of special nuclear material: neutrons produced in nuclear fission. However, neutrons produced by photonuclear reactions in the accelerator target, collimator, and environment can obscure the fission neutron signal. These (γ, n) neutrons could be discriminated from fission neutrons by their energy spectrum, but common detectors sensitive to the neutron spectrum, like organic scintillators, are typically hampered by the intense photon background characteristic of photon-based active interrogation. In contrast, high-pressure 4 ⁢He-based scintillation detectors are well-suited to photon active interrogation, as they are similarly sensitive to fast neutrons and can measure their spectrum, but show little response to gamma rays. Here, in this work, a photon active interrogation system utilizing a 4 ⁢He scintillation detector and a 9 MeV linac-bremsstrahlung x-ray source was experimentally evaluated. The detector was shown to be capable of operating in intense gamma-ray environments and detecting photofission neutrons from 238 ⁢U when interrogated by this x-ray source. The photofission neutrons show clear spectral separation from (γ, n) neutrons produced in lead, a common shielding material.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scintillation yield from electronic and nuclear recoils in superfluid He 4

Superfluid $^4$He is a promising target material for direct detection of light ($<$ 1 GeV) dark matter. Possible signal channels available for readout in this medium include prompt photons, triplet excimers, and roton and phonon quasiparticles. The relative yield of these signals has implications for the sensitivity and discrimination power of a superfluid $^4$He dark matter detector. Using a 16~cm$^3$ volume of 1.75~K superfluid $^4$He read out by six immersed photomultiplier tubes, we measured the scintillation from electronic recoils ranging between 36.3 and 185~keV$_\mathrm{ee}$, yielding a mean signal size of $1.25^{+0.03}_{-0.03}$~phe/keV$_\mathrm{ee}$, and nuclear recoils from 53.2 to 1090~keV$_\mathrm{nr}$. We compare the results of our relative scintillation yield measurements to an existing semiempirical model based on helium-helium and electron-helium interaction cross sections. As a result, we also study the behavior of delayed scintillation components as a function of recoil type and energy, a further avenue for signal discrimination in superfluid $^4$He.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Crystal Growth and Characterization of Europium-Doped Rubidium Calcium Bromide Scintillators

National security strategies like gamma spectroscopy and high-energy X-ray radiography are limited, in part, by the scintillator used, prompting research into novel materials with improved properties. In this paper, Eu 2+ activated rubidium calcium bromide scintillators were grown via the vertical Bridgman method with a range of dopant concentrations. Light yield, energy resolution, and the afterglow of Rb 4 CaBr 6 :Eu and RbCaBr 3 :Eu improved with increasing Eu 2+ concentration, and scintillation decay time increased. The highest light yields of Rb 4 CaBr 6 :Eu and RbCaBr 3 :Eu were 71000 and 45000 ph/MeV, respectively.

36 MATERIALS SCIENCE↗

Proton Quenching in Rare-Earth Inorganic Scintillators: GAGG:Ce and YSO:Ce

Scintillator detectors are an integral component of radiation detection systems for a variety of applications such as medical imaging, accelerator diagnostics, and space science. Typically, a scintillator detector’s response is characterized using gamma sources to understand the detection response to different types of radiation, including charged particle detection. However, there exists a nonlinearity of the amount of light produced from an incident gamma ray of specific energy and the light produced from an incident charged particle of the same energy. This important effect, known as quenching, must be accounted for to interpret energies from charged particles incident on detectors. In this article, we present results of quenching parameterization for two types of cerium-doped inorganic scintillators, Y2SiO5:Ce (YSO:Ce) and Gd3Al2Ga3O12:Ce (GAGG:Ce). We measured the light output from incident proton energies from 1 to 25 MeV using a 3-MV tandem accelerator and two reactions: Au(p,p)Au and 3He(d,p)⁴He. Using gamma-ray sources to calibrate the detectors, we compared the measured electron-equivalent energy versus the incident energy expected. Using an adaptation of the Birks semi-empirical formula, we extracted the Birks parameter (kB) to understand quenching. For one of the GAGG:Ce samples, the kB parameter of 0.0072 [g cm-2 MeV-1] is comparable to a similar study where the value of kB was 0.0065 [g cm-2 MeV-1]. For YSO:Ce, no other kB values were found in the literature. Three different types of GAGG:Ce were used to collect measurements of kB as a function of dopant concentration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of the Rossi-alpha method to simulations of HEU and organic scintillators

The International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook contains thousands of high-quality benchmark measurements that include detailed descriptions of experiment designs and exhaustive accounting of uncertainties. These benchmarks are used extensively by the criticality safety and nuclear data communities. A subcritical benchmark involving bare, highly enriched uranium (HEU) has yet to be accepted to the handbook. The Measurement of Uranium Subcritical and Critical (MUSiC) was proposed to address this gap. MUSiC will be performed at the National Criticality Experiments Research Center (NCERC) and will leverage bare HEU hemisphere shells that can be assembled in a variety of configurations. The measurement has the following key benefits: it will be the first set of fast, subcritical measurements of HEU to be submitted to ICSBEP; ten configurations will be measured spanning from nearly no multiplication to critical (e.g., it is a measurement of similar systems with different re activities); measurements of an all-HEU system will be of value for nuclear data validation, providing results that assist in determining biases in both measurements and simulations. A variety of detector systems will be used including a Neutron Multiplicity Array Detector (NoMAD) system (similar to the MC-15), four small volume 0.635 cm (#8960;) × 7.59 cm 3He detectors (ideal for measuring prompt neutron decay constants due to their fast recovery speed), and an array of eight 5.08 cm (#8960;) × 5.08 cm EJ-309 organic scintillator detectors. The focus of this work is the simulation of the subcritical MUSiC configurations including the EJ-309 detectors and the application of the Rossi-α method. The EJ-309 organic scintillator detector array is a new detection system that will be deployed at NCERC. Organic scintillators are ideal for measurements of fast, subcritical systems due to their short time response on the order of nanoseconds.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and implementation of the new scintillation light detection system of ICARUS T600

ICARUS T600 is the far detector of the Short Baseline Neutrino program at Fermilab (U.S.A.), which foresees three Liquid Argon Time Projection Chambers along the Booster Neutrino Beam line to search for LSND-like sterile neutrino signal. The T600 detector underwent a significant overhauling process at CERN, introducing new technological developments while maintaining the already achieved performances. The realization of a new liquid argon scintillation light detection system is a primary task of the detector overhaul. As the detector will be subject to a huge flux of cosmic rays, the light detection system should allow the 3D reconstruction of events contributing to the identification of neutrino interactions in the beam spill gate. The design and implementation of the new scintillation light detection system of ICARUS T600 is described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of scintillation light collection, production and propagation in a 4 tonne dual-phase LArTPC

The 3×1×1 m3 demonstrator is a dual phase liquid argon time projection chamber that has recorded cosmic rays events in 2017 at CERN. The light signal in these detectors is crucial to provide precise timing capabilities. The performance of the photon detection system, composed of five PMTs, are discussed. The collected scintillation and electroluminescence light created by passing particles has been studied in various detector conditions. In particular, the scintillation light production and propagation processes have been analyzed and compared to simulations, improving the understanding of some liquid argon properties.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗