Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “scan report”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Direct measurement of the thermal expansion coefficient of epitaxial WSe 2 by four-dimensional scanning transmission electron microscopy

Current reports of thermal expansion coefficients (TEC) of two-dimensional (2D) materials show large discrepancies that span orders of magnitude. Determining the TEC of any 2D material remains difficult due to approaches involving indirect measurement of samples that are atomically thin and optically transparent. We demonstrate a methodology to address this discrepancy and directly measure TEC of nominally monolayer epitaxial WSe 2 using four-dimensional scanning transmission electron microscopy (4D-STEM). Experimentally, WSe 2 from metal-organic chemical vapor deposition (MOCVD) was heated through a temperature range of 18- 564 °C using a barrel-style heating sample holder to observe temperature-induced structural changes without additional alterations or destruction of the sample. By combining 4D-STEM measurements with quantitative structural analysis, the thermal expansion coefficient of nominally monolayer polycrystalline epitaxial 2D WSe 2 was determined to be (3.5 ± 0.9) × 10 -6 K -1 and (5.7 ± 2) × 10 -5 K -1 for the in- and out-of-plane TEC, respectively, and (3.6 ± 0.2) × 10 -5 K -1 for the unit cell volume TEC, in good agreement with historically determined values for bulk crystals.

2D materials↗

Atomic-resolution scanning transmission electron microscopy through 50-nm-thick silicon nitride membranes

Silicon nitride membranes can be used for windows of environmental chambers for in situ electron microscopy. We report that aberration corrected scanning transmission electron microscopy (STEM) achieved atomic resolution on gold nanoparticles placed on both sides of a 50-nm-thick silicon nitride membrane at 200 keV electron beam energy. Spatial frequencies of 1/1.2 A were visible for a beam semi-angle of 26.5 mrad. Imaging though a 100-nm-thick membrane was also tested. The achieved imaging contrast was evaluated using Monte Carlo simulations of the STEM imaging of a sample of with a representative geometry and composition.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effectiveness and Safety of Spot Scanning Proton Radiation Therapy for Chordomas and Chondrosarcomas of the Skull Base: First Long-Term Report

Purpose: To evaluate effectiveness and safety of spot-scanning-based proton radiotherapy (PT) in skull-base chordomas and chondrosarcomas. Methods and Materials: Between October 1998 and November 2005, 64 patients with skull-base chordomas (n = 42) and chondrosarcomas (n = 22) were treated at Paul Scherrer Institute with PT using spot-scanning technique. Median total dose for chordomas was 73.5 Gy(RBE) and 68.4 Gy(RBE) for chondrosarcomas at 1.8-2.0 Gy(RBE) dose per fraction. Local control (LC), disease specific survival (DSS), and overall survival (OS) rates were calculated. Toxicity was assessed according to CTCAE, v. 3.0. Results: Mean follow-up period was 38 months (range, 14-92 months). Five patients with chordoma and one patient with chondrosarcoma experienced local recurrence. Actuarial 5-year LC rates were 81% for chordomas and 94% for chondrosarcomas. Brainstem compression at the time of PT (p = 0.007) and gross tumor volume >25 mL (p = 0.03) were associated with lower LC rates. Five years rates of DSS and OS were 81% and 62% for chordomas and 100% and 91% for chondrosarcomas, respectively. High-grade late toxicity consisted of one patient with Grade 3 and one patient with Grade 4 unilateral optic neuropathy, and two patients with Grade 3 central nervous system necrosis. No patient experienced brainstem toxicity. Actuarial 5-year freedom from high-grade toxicity was 94%. Conclusions: Our data indicate safety and efficacy of spot-scanning based PT for skull-base chordomas and chondrosarcomas. With target definition, dose prescription and normal organ tolerance levels similar to passive-scattering based PT series, complication-free, tumor control and survival rates are at present comparable.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Enhanced phase contrast transfer using ptychography combined with a pre-specimen phase plate in a scanning transmission electron microscope

We report the ability to image light elements in both crystalline and noncrystalline materials at near atomic resolution with an enhanced contrast is highly advantageous to understand the structure and properties of a wide range of beam sensitive materials including biological specimens and molecular hetero-structures. This requires the imaging system to have an efficient phase contrast transfer at both low and high spatial frequencies. Here, we introduce a new phase contrast imaging method in a scanning transmission electron microscope (STEM) using a pre-specimen phase plate in the probe forming aperture, combined with a fast pixelated detector to record diffraction patterns at every probe position, and phase reconstruction using ptychography. The phase plate significantly enhances the contrast transfer of low spatial frequency information, and ptychography maximizes the extraction of the phase information at all spatial frequencies. In addition, the STEM probe with the presence of the phase plate retains its atomic resolution, allowing simultaneous incoherent Z-contrast imaging to be obtained along with the ptychographic phase image. An experimental image of Au nanoparticles on a carbon support shows high contrast for both materials. Multislice image simulations of a DNA molecule shows the capability of imaging soft matter at low dose conditions, which implies potential applications of low dose imaging of a wide range of beam sensitive materials.

36 MATERIALS SCIENCE↗

Optical identification of 4U1907 + 09 using the HEAO-1 scanning modulation collimator position

The paper reports an optical identification of 4U1907 + 09 with a m(v) = 16.4 stellar object in the location determined by the scanning modulation collimator experiment on the first High Energy Astronomy Observatory (HEAO-1). The identification is based on the presence of very strong and broad H-alpha emission. The optical data constrain the distance to be 2-13 kpc, and this gives a range of uncertainty to the typical 2-10 keV luminosity of (1 x 10 to the 35th to 3 x 10 to the 36th) erg/s. The X-ray spectrum and variability is reported, and consideration is given to the hypothesis that the object is an OB supergiant, although its faintness in the blue makes precise spectral classification impossible. It is suggested that this system is an example of a luminous, massive primary emitting a stellar wind which is accreted on the compact object.

Schwartz, D. A.↗

A terraced scanning superconducting quantum interference device susceptometer with submicron pickup loops

Superconducting quantum interference devices (SQUIDs) can have excellent spin sensitivity depending on their magnetic flux noise, pickup loop diameter, and distance from the sample. We report a family of scanning SQUID susceptometers with terraced tips that position the pickup loops 300 nm from the sample. The 600 nm-2 {mu}m pickup loops, defined by focused ion beam, are integrated into a 12-layer optical lithography process allowing flux-locked feedback, in situ background subtraction and optimized flux noise. These features enable a sensitivity of {approx}70 electron spins per root hertz at 4 K.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a scanning surface probe for nanoscal tip-enhanced desorption/ablation

We report on the development of a versatile scanning apparatus for nanoscale surface sampling that utilizes the interaction of laser radiation at a sharp probe tip to effect desorption/ablation on opaque substrates. The process, which currently yields surface craters as small as ~50 nm diameter X5 nm deep, has been demonstrated with both metal-coated and bare silicon tips. Desorption/ablation under the tip occurs at illumination intensities below the corresponding optical far-field threshold, suggesting that the latter process should not degrade the spatial resolution attainable for proposed chemical imaging methods based on the scanning surface probe.

47 OTHER INSTRUMENTATION↗

Multipurpose active scanning probe cantilevers for near-field spectroscopy, scanning tunnel imaging, and atomic-resolution lithography

In this work, we report progress on developing a multipurpose scanning probe cantilever applying gallium nitride nanowires as the probe tip. Gallium nitride nanowires possess high potential as probes due to their straight profile, tunable electrical and optical properties, high Young’s Modulus, durability, and high-yield fabrication process. Their wide bandgap enables them to be pumped to emit ultraviolet pulses which can be used for optical imaging and spectroscopy. They can be doped during growth to be electrically conductive, and their sharp tips obtained during epitaxial growth enable confinement of a high electric field at tip–sample interface. Their sharp tips are obtained during fabrication by their epitaxial growth which eliminates the need for postprocess sharpening that is typically required for standard STM tips. We present results of using gallium nitride nanowires for scanning tunnel microscopy applications of atomic-resolution imaging and lithography, and atomic force microscopy applications of imaging and lithography in vacuum and atmospheric environments.

Engineering↗

Fiber Scanning Array for 3 Dimensional Topographic Imaging

We report on the design and development of a fiber optic scanning 3-D LIDAR employing a switched fiber array. This design distributes ns length laser pulses over a sample field, collects the return pulses, and assembles them into a 3-D image. This instrument is a reduced size version consisting of 35 beams, and will serve as a proof-of-principle demonstration for a planned 1000 beam instrument for Earth and planetary topographical missions.

3D↗

Demonstration of an AI-driven workflow for autonomous high-resolution scanning microscopy

Abstract Modern scanning microscopes can image materials with up to sub-atomic spatial and sub-picosecond time resolutions, but these capabilities come with large volumes of data, which can be difficult to store and analyze. We report the Fast Autonomous Scanning Toolkit (FAST) that addresses this challenge by combining a neural network, route optimization, and efficient hardware controls to enable a self-driving experiment that actively identifies and measures a sparse but representative data subset in lieu of the full dataset. FAST requires no prior information about the sample, is computationally efficient, and uses generic hardware controls with minimal experiment-specific wrapping. We test FAST in simulations and a dark-field X-ray microscopy experiment of a WSe 2 film. Our studies show that a FAST scan of <25% is sufficient to accurately image and analyze the sample. FAST is easy to adapt for any scanning microscope; its broad adoption will empower general multi-level studies of materials evolution with respect to time, temperature, or other parameters.

47 OTHER INSTRUMENTATION↗

IMS Rapid Response FY21 Summary Report for: Integrating Patterned Probes with Four-Dimensional Scanning Transmission Electron Microscopy for Unrivaled Crystallographic Structure Determination in Nanomaterials

The initial goal of our 4-dimensional scanning transmission electron microscopy (4D-STEM)-based project was to develop strain resolution two orders of magnitude better than what is now currently possible with electron-based scattering techniques, all while collecting scattering information from 7 different tilt axes at one time [multi-beam electron diffraction (MBED)1 ] through the development of a new electron probe-forming aperture with non-circular features (patterned probes 2 ). We set out to accomplish this through a collaboration with Drs. Colin Ophus and Ben Savitsky at Lawrence Berkeley Laboratory (they are the world-leading experts in developing the complex computational codes required to perform orientation analysis and quantitative strain mapping on our 4D-STEM data sets. We are motivated to invest in this area as it will be the only technique sensitive enough to perform three- dimensional automated crystallographic orientation mapping (ACOM) and strain mapping for materials exposed to external stimulus (a focus of our larger efforts).

36 MATERIALS SCIENCE↗

State Charlton 4-30 Core Description

CT and core scanning data associated with Technical Report Series report Vornlocher, J.; Betters, C.; Paronish. T.; Crandall, D.; Moore, J,; Schmitt, R.; Harrison, III, W.B. Computed Tomography Scanning and Geophysical Measurements of Core from the State Charlton #4-30 Well; NETL-TRS-8-2019; NETL Technical Report Series; US Department of Energy, National Energy Technology Laboratory; Morgantown, WV, 2019; p 64.

Carbon Storage,Computed Tomography,Core Scanning↗

SU-G-206-11: The Effect of Table Height On CTDIvol and SSDE in CT Scanning: A Phantom Study

Purpose: Localizer projection radiographs acquired prior to CT scans are used to estimate patient size, affecting the function of Automatic Tube Current Modulation (ATCM) and calculation of the Size Specific Dose Estimate (SSDE). Due to geometric effects, the projected patient size varies with scanner table height and with the orientation of the localizer (AP versus PA). Consequently, variations in scanner table height may affect both CTDIvol and the calculated size-corrected dose index (SSDE). This study sought to characterize these effects. Methods: An anthropomorphic phantom was imaged using an AP localizer, followed by a diagnostic scan using ATCM and our institution’s routine abdomen protocol. This was repeated at various scanner table heights, recording the scanner-reported CTDIvol for each diagnostic scan. The width of the phantom was measured from the localizer and diagnostic images using in-house software. The measured phantom width and scanner-reported CTDIvol were used to calculate SSDE. This was repeated using PA localizers followed by diagnostic scans. Results: 1) The localizer-based phantom width varied by up to 54% of the nominal phantom width between minimum and maximum table heights. 2) Changing the table height caused a variation in scanner-reported CTDIvol of a factor greater than 4.6 when using a PA localizer and almost 2 when using an AP localizer. 3) SSDE, calculated from measured phantom size and scanner-reported CTDIvol, varied by a factor of more than 2.8 when using a PA localizer and almost 1.5 when using an AP localizer. Conclusion: Our study demonstrates that off-center patient positioning affects the efficacy of ATCM, more severely when localizers are acquired in the PA rather than AP projection. Further, patient positioning errors can cause a large variation in the calculated SSDE. This hinders interpretation of SSDE for individual patients and aggregate SSDE data when evaluating CT protocols and clinical practices.

60 APPLIED LIFE SCIENCES↗

Computed Tomography Scanning and Geophysical Measurements of the Smackover Formation from the Roberson 18-19 Core

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the U.S. Department of Energy’s (DOE) National Energy Technology Laboratory (NETL) site in Morgantown, West Virginia, were used to characterize the Upper Jurassic (Oxfordian) Smackover limestone in the Roberson 18-19 1-15H core retrieved from the Atlanta Field, Columbia County, Arkansas. The 365.68-ft long Roberson core came from a vertical well at depths 8,802 ft to 9,169.60 ft, drilled by Southwestern Energy targeting the Smackover Formation as a potential unconventional oil reservoir. The primary impetus of this work was to non-destructively characterize core from the Smackover Formation that was acquired through a core exchange with Southwestern Energy. The Smackover Formation is an unconventional limestone play in southern Arkansas. This report and the associated scans provide detailed datasets not typically made publicly available from unconventional limestone for analysis. The resultant datasets are presented in this report and can be accessed from NETL’s Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/roberson-smackover.

58 GEOSCIENCES↗

SU-E-T-509: Inter-Observer and Inter-Modality Contouring Analysis for Organs at Risk for HDR Gynecological Brachytherapy

Purpose This study quantifies errors associated with MR-guided High Dose Rate (HDR) gynecological brachytherapy. Uncertainties in this treatment results from contouring, organ motion between imaging and treatment delivery, dose calculation, and dose delivery. We focus on interobserver and inter-modality variability in contouring and the motion of organs at risk (OARs) in the time span between the MR and CT scans (∼1 hour). We report the change in organ volume and position of center of mass (CM) between the two imaging modalities. Methods A total of 8 patients treated with MR-guided HDR brachytherapy were included in this study. Two observers contoured the bladder and rectum on both MR and CT scans. The change in OAR volume and CM position between the MR and CT imaging sessions on both image sets were calculated. Results The absolute mean bladder volume change between the two imaging modalities is 67.1cc. The absolute mean inter-observer difference in bladder volume is much lower at 15.5cc (MR) and 11.0cc (CT). This higher inter-modality volume difference suggests a real change in the bladder filling between the two imaging sessions. Change in Rectum volume inter-observer standard error of means (SEM) is 3.18cc (MR) and 3.09cc (CT), while the inter-modality SEM is 3.65cc (observer 1), and 2.75cc (observer 2). The SEM for rectum CM position in the superior-inferior direction was approximately three times higher than in other directions for both the inter—observer (0.77 cm, 0.92 cm for observers 1 and 2, respectively) and inter-modality (0.91 cm, 0.95 cm for MR and CT, respectively) variability. Conclusion Bladder contours display good consistency between different observers on both CT and MR images. For rectum contouring the highest inconsistency stems from the observers’ choice of the superior-inferior borders. A complete analysis of a larger patient cohort will enable us to separate the true organ motion from the inter-observer variability.

60 APPLIED LIFE SCIENCES↗

Laser Fabrication of Two-Dimensional Rotating-Lattice Single Crystal

A rotating lattice single (RLS) crystal is a unique form of solid, which was fabricated recently as one-dimensional architecture in glass via solid state transformation induced by laser irradiation. In these objects, the lattice rotates gradually and predictably about an axis that lies in the plane of the crystal and is normal to the laser scanning direction. This paper reports on the fabrication of Sb 2 S 3 two-dimensional (2D) RLS crystals on the surface of 16SbI 3 -84Sb 2 S 3 glass, as a model example: individual RLS crystal lines are joined together using "stitching" or "rastering" as two successful protocols. The electron back scattered diffraction mapping and scanning Laue X-ray microdiffraction of the 2D RLS crystals show gradual rotation of lattice comprising of two components, one along the length of each line and another normal to this direction. The former component is determined by the rotation of the first line of the 2D pattern, but the relative contribution of the last component depends on the extent of overlap between two successive lines. By the appropriate choice of initial seed orientation and the direction of scanning, it is possible to control the lattice rotation, and even to reduce it down to 5 for a 50 × 50 μm 2 2D pattern of Sb 2 S 3 crystal.

36 MATERIALS SCIENCE↗