Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sampler”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Plug & play directed evolution of proteins with gradient-based discrete MCMC

Abstract A long-standing goal of machine-learning-based protein engineering is to accelerate the discovery of novel mutations that improve the function of a known protein. We introduce a sampling framework for evolving proteins in silico that supports mixing and matching a variety of unsupervised models, such as protein language models, and supervised models that predict protein function from sequence. By composing these models, we aim to improve our ability to evaluate unseen mutations and constrain search to regions of sequence space likely to contain functional proteins. Our framework achieves this without any model fine-tuning or re-training by constructing a product of experts distribution directly in discrete protein space. Instead of resorting to brute force search or random sampling, which is typical of classic directed evolution, we introduce a fast Markov chain Monte Carlo sampler that uses gradients to propose promising mutations. We conduct in silico directed evolution experiments on wide fitness landscapes and across a range of different pre-trained unsupervised models, including a 650 M parameter protein language model. Our results demonstrate an ability to efficiently discover variants with high evolutionary likelihood as well as estimated activity multiple mutations away from a wild type protein, suggesting our sampler provides a practical and effective new paradigm for machine-learning-based protein engineering.

59 BASIC BIOLOGICAL SCIENCES↗

Characterization of the Emissions and Crystalline Silica Content of Airborne Dust Generated from Grinding Natural and Engineered Stones

Abstract In this study, we systematically characterized the airborne dust generated from grinding engineered and natural stone products using a laboratory testing system designed and operated to collect representative respirable dust samples. Four stone samples tested included two engineered stones consisting of crystalline silica in a polyester resin matrix (formulations differed with Stones A having up to 90wt% crystalline silica and Stone B up to 50wt% crystalline silica), an engineered stone consisting of recycled glass in a cement matrix (Stone C), and a granite. Aerosol samples were collected by respirable dust samplers, total dust samplers, and a Micro-Orifice Uniform Deposit Impactor. Aerosol samples were analyzed by gravimetric analysis and x-ray diffraction to determine dust generation rates, crystalline silica generation rates, and crystalline silica content. Additionally, bulk dust settled on the floor of the testing system was analyzed for crystalline silica content. Real-time particle size distributions were measured using an Aerodynamic Particle Sizer. All stone types generated similar trimodal lognormal number-weighted particle size distributions during grinding with the most prominent mode at an aerodynamic diameter of about 2.0-2.3 μm, suggesting dust formation from grinding different stones is similar. Bulk dust from Stone C contained no crystalline silica. Bulk dust from Stone A, Stone B, and granite contained 60, 23, and 30wt% crystalline silica, respectively. In Stones A and B, the cristobalite form of crystalline silica was more plentiful than the quartz form. Only the quartz form was detected in granite. The bulk dust, respirable dust, and total dust for each stone had comparable amounts of crystalline silica, suggesting that crystalline silica content in the bulk dust could be representative of that in respirable dust generated during grinding. Granite generated more dust per unit volume of material removed than the engineered stones, which all had similar normalized dust generation rates. Stone A had the highest normalized generation rates of crystalline silica, followed by granite, Stone B, and Stone C (no crystalline silica), which likely leads to the same trend of respirable crystalline silica (RCS) exposure when working with these different stones. Manufacturing and adoption of engineered stone products with formulations such as Stone B or Stone C could potentially lower or eliminate RCS exposure risks. Combining all the effects of dust generation rate, size-dependent silica content, and respirable fraction, the highest normalized generation rate of RCS consistently occurs at 3.2-5.6 µm for all the stones containing crystalline silica. Therefore, removing particles in this size range near the generation sources should be prioritized when developing engineering control measures.

Public, Environmental & Occupational Health↗

nautilus : boosting Bayesian importance nested sampling with deep learning

ABSTRACT We introduce a novel approach to boost the efficiency of the importance nested sampling (INS) technique for Bayesian posterior and evidence estimation using deep learning. Unlike rejection-based sampling methods such as vanilla nested sampling (NS) or Markov chain Monte Carlo (MCMC) algorithms, importance sampling techniques can use all likelihood evaluations for posterior and evidence estimation. However, for efficient importance sampling, one needs proposal distributions that closely mimic the posterior distributions. We show how to combine INS with deep learning via neural network regression to accomplish this task. We also introduce nautilus, a reference open-source python implementation of this technique for Bayesian posterior and evidence estimation. We compare nautilus against popular NS and MCMC packages, including emcee, dynesty, ultranest, and pocomc, on a variety of challenging synthetic problems and real-world applications in exoplanet detection, galaxy SED fitting and cosmology. In all applications, the sampling efficiency of nautilus is substantially higher than that of all other samplers, often by more than an order of magnitude. Simultaneously, nautilus delivers highly accurate results and needs fewer likelihood evaluations than all other samplers tested. We also show that nautilus has good scaling with the dimensionality of the likelihood and is easily parallelizable to many CPUs.

97 MATHEMATICS AND COMPUTING↗

EvoProtGrad (Directed Evolution for Proteins with Gradients) [SWR-23-48]

A Python package for directed evolution on a protein sequence with gradient-based discrete Markov chain monte carlo (MCMC). Users are able to compose custom models that map sequence to function with pretrained models, including protein language models (PLMs), to guide and constrain search. Our package natively integrates with the HuggingFace platform and supports PLMs from transformers. Our MCMC sampler identifies promising amino acids to mutate via model gradients taken with respect to the input (i.e., sensitivity analysis). We allow users to compose their own custom target function for MCMC by leveraging the Product of Experts MCMC paradigm. Each model is an "expert" that contributes its own knowledge about the protein's fitness landscape to the overall target function. The sampler is designed to be more efficient and effective than brute force and random search while maintaining most of the generality and flexibility. Additional information can be found in the related publication: https://iopscience.iop.org/article/10.1088/2632-2153/accacd

Emami, Patrick↗

Generalized Bayesian Framework for Evaluation of Integral Benchmark Experiments

A recently published generalized Bayesian optimization framework has provided a way to retract any or all of the three common assumptions underlying the conventional Generalized Linear Least Squares (GLLS) optimization method based on the concepts introduced in Ref. [2]. These assumptions are: 1. Perfection: The model used for data evaluation and the prior probability distribution function (PDF) of generalized data are perfect. 2. Normality: The prior and posterior PDF are normal. 3. Linearity: The model is linear. In this work we outline how the framework in [1] could be directly adopted for improved evaluation of nuclear criticality integral benchmark experiments (IBEs) by: 1. Removing the first assumption alone by utilizing the concept of imperfections introduced in [1] to enable evaluation in the presence of discrepancies between the data and model or of missing covariance information by a GLLS method that will be seen as a generalization of the conventional GLLS method employed by the TSURFER code, and by 2. Removing the remaining two assumptions by implementing a Markov Chain Monte Carlo method for computation of the posterior PDF in the SAMPLER code, where TSURFER and SAMPLER are the uncertainty quantification (UQ) codes for IBEs in the SCALE code system based on the GLLS and the stochastic method, respectively. The graphic in Figure 1 categorizes the methods discussed in terms of the assumptions that they employ to determine posterior PDFs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Automated Airborne Pathogen Monitoring for Agriculture (CRADA Final Report)

As part of the Cyclotron Road program, Root Applied Sciences investigated the use of DNA-based assays under field conditions to detect airborne plant pathogens in environmental samples. Robust DNA-based assays are critical for automated monitoring of plant pathogen concentrations in the air using Root’s air samplers. A fully automated air sampler coupled with DNA-based assays capable of operating under field conditions will accelerate the delivery of disease risk alerts based on airborne inoculum loads. Timely and accurate alerts of pathogen loads in the air can help growers manage airborne diseases more precisely, avoiding fungicide applications when there is no threat, and focusing cultural practices in the right areas. This project built upon other work done by Root to study the in-field performance of a liquid DNA-based assay for detection of grape powdery mildew. Growers working with Root’s airborne powdery mildew monitoring system have reported 20-80% reductions in pesticides.

60 APPLIED LIFE SCIENCES↗

Deployment of salt sample extraction system at an engineering-scale electrorefiner

The goal of the salt sampling program at Argonne is to develop and deploy automated molten salt sampling approaches for interfacing relevant unit operations with salt analysis to improve the timeliness of sampling-based accountancy measurements. Two technologies under development in support of this goal are a vacuum sampling loop module and a high-throughput pneumatic sample generator module. Compared to traditional point sampling approaches (i.e., dip probes), the vacuum sampling loop facilitates the collection of a larger cross-section of the bulk salt in order to collect more representative samples. The vacuum sampling approach also eliminates the risk of dross contamination of samples and avoids the use of moving parts in the salt. The pneumatic sample generator module is used to facilitate high-throughput sample analysis to improve the measurement precision of any given analytical technique by averaging out random sampling and measurement errors. In FY21, two methods for integrating these two modules were tested including direct fluidic coupling and coupling using a solid salt transfer mechanism. Solid salt transfer was ultimately selected over fluidic coupling, primarily to enable the transport of samples over longer distances to support automated at-line integration with high-precision techniques (such as microcalorimetry) that cannot withstand the conditions near an electrorefining process. To facilitate rapid solid salt coupling, new mechanisms were developed for rapidly charging and discharging salt sample tubes at the vacuum sampling loop and pneumatic sample generator modules, respectively. While the charging mechanism will be deployed in FY22, the discharge mechanism was tested in FY21 and is described here. The solid salt tube transfer method was deployed at one of Argonne’s engineering-scale electrorefiners to implement at-line high-throughput pneumatic micro-sample generation capabilities. The approach was used to generate precise uranium- and lanthanide-bearing electrorefiner micro-samples with the specific dimensions requested by researchers at Los Alamos National Laboratory for use in testing their novel microcalorimeter x-ray techniques. The solid salt transfer mechanism proved not only to be an effective means of integrating the precision sample generator with vacuum sampling, but also improved the performance of the sampler generator. To discharge salt from the sample tubes at the sampler generator, tube segments were inserted directly into the sample generator’s Helmholtz chamber and pressure pulse actuations were used to generate precision molten salt samples directly from the tube segments. The direct insertion of sample tubes into the sample generator enabled rapid loading of the salt and prevented salt from contacting most of the interior surfaces of the sample generator, which eliminated cross-contamination between runs. The vacuum sampling-loop tube charging mechanism will support high-throughput tube sampling operations by employing a dynamic vacuum filling process to fill short charge tubes that are configured to be rapidly connected and disconnected from the loop. The dynamic vacuum sampling operation will be automated, and sample tube handling can be executed with simple overhead actuation. Because the modular sampling approach described here eliminates the need for new high-radiation sample handling capabilities, salt-wetted seals, salt-wetted moving parts, and heated transfer lines outside the electrorefiner, it will address most of the remaining technical challenges for the at-line deployment of high-precision analytical techniques which will enable significant reductions in the time delay for sampling-based high-precision accountancy measurements.

42 ENGINEERING↗

Addressing GPU memory limitations for Graph Neural Networks in High-Energy Physics applications

Introduction Reconstructing low-level particle tracks in neutrino physics can address some of the most fundamental questions about the universe. However, processing petabytes of raw data using deep learning techniques poses a challenging problem in the field of High Energy Physics (HEP). In the Exa.TrkX Project, an illustrative HEP application, preprocessed simulation data is fed into a state-of-art Graph Neural Network (GNN) model, accelerated by GPUs. However, limited GPU memory often leads to Out-of-Memory (OOM) exceptions during training, due to the large size of models and datasets. This problem is exacerbated when deploying models on High-Performance Computing (HPC) systems designed for large-scale applications. Methods We observe a high workload imbalance issue during GNN model training caused by the irregular sizes of input graph samples in HEP datasets, contributing to OOM exceptions. We aim to scale GNNs on HPC systems, by prioritizing workload balance in graph inputs while maintaining model accuracy. Our paper introduces diverse balancing strategies aimed at decreasing the maximum GPU memory footprint and avoiding the OOM exception, across various datasets. Results Our experiments showcase memory reduction of up to 32.14% compared to the baseline. We also demonstrate the proposed strategies can avoid OOM in application. Additionally, we create a distributed multi-GPU implementation using these samplers to demonstrate the scalability of these techniques on the HEP dataset. Discussion By assessing the performance of these strategies as data loading samplers across multiple datasets, we can gauge their effectiveness in both single-GPU and distributed environments. Our experiments, conducted on datasets of varying sizes and across multiple GPUs, broaden the applicability of our work to various GNN applications that handle input datasets with irregular graph sizes.

Lee, Claire Songhyun↗

A Comparative Multi-System Approach to Characterizing Bioactivity of Commonly Occurring Chemicals

A 2019 retrospective study analyzed wristband personal samplers from fourteen different communities across three different continents for over 1530 organic chemicals. Investigators identified fourteen chemicals (G14) detected in over 50% of personal samplers. The G14 represent a group of chemicals that individuals are commonly exposed to, and are mainly associated with consumer products including plasticizers, fragrances, flame retardants, and pesticides. The high frequency of exposure to these chemicals raises questions of their potential adverse human health effects. Additionally, the possibility of exposure to mixtures of these chemicals is likely due to their co-occurrence; thus, the potential for mixtures to induce differential bioactivity warrants further investigation. This study describes a novel approach to broadly evaluate the hazards of personal chemical exposures by coupling data from personal sampling devices with high-throughput bioactivity screenings using in vitro and non-mammalian in vivo models. To account for species and sensitivity differences, screening was conducted using primary normal human bronchial epithelial (NHBE) cells and early life-stage zebrafish. Mixtures of the G14 and most potent G14 chemicals were created to assess potential mixture effects. Chemical bioactivity was dependent on the model system, with five and eleven chemicals deemed bioactive in NHBE and zebrafish, respectively, supporting the use of a multi-system approach for bioactivity testing and highlighting sensitivity differences between the models. In both NHBE and zebrafish, mixture effects were observed when screening mixtures of the most potent chemicals. Observations of BMC-based mixtures in NHBE (NHBE BMC Mix) and zebrafish (ZF BMC Mix) suggested antagonistic effects. In this study, consumer product-related chemicals were prioritized for bioactivity screening using personal exposure data. High-throughput high-content screening was utilized to assess the chemical bioactivity and mixture effects of the most potent chemicals.

60 APPLIED LIFE SCIENCES↗

TRACER-Tethersonde VOC data

One objective of TRACER-Tethersonde campaign was to deploy a volatile organic compound (VOC) sampler on the Tethered Balloon System (TBS) to create vertical profiles and characterize VOC composition. Volatile organic compounds (VOCs) are highly reactive precursor species that undergo atmospheric processing to form secondary products, including aerosol. VOC emissions are influenced by many factors that include but are not limited to temperature, time of day, local anthropogenic activities, and local vegetation, which result in large spatiotemporal variability. The vertical distribution of volatile species is crucial for understanding gas-phase processing for particle production but challenging to accomplish using currently available sampling devices. The standalone sampler built during the campaign enabled the execution of robust experimental designs, including sample collection using resin tubes at multiple altitudes on subsequent flights. Following field sampling, resin tubes were transported back to Baylor University for chemical analysis using a Markes International thermal desorption unit coupled with a gas chromatograph-tandem mass spectrometer (Thermo Scientific). The target analyte list includes biogenic and anthropogenic VOCs.

54 ENVIRONMENTAL SCIENCES↗

tbsinp (00)

The ice nucleation spectrometer (INS) is an offline analytical measurement system used to process filter samples for freezing temperature spectra of immersion-mode ice-nucleating particle (INP) number concentrations. It is almost identical to the Colorado State University (CSU) ice spectrometer design. The INS-AIR is specific to filter samples collected on aerial platforms, such as the DOE ARM tethered balloon system (TBS) operated by Sandia National Laboratories, using miniaturized aerosol filter samplers. Users are referred to the INS instrument handbook for INS-AIR sampler details. INS-AIR filter samples are collected during intensive operational periods at various ARM sites and then processed on the INS at CSU. This filter log contains the detailed metadata at all ARM sites where INP filter sample collection has occurred or is currently ongoing, including both ground-based routine INP sampling (INS) and TBS INP sampling (INS-AIR). Metadata include start and end times, vacuum line pressures and temperatures, and flow rates; total accumulated flow through each filter; and notes on collection issues or weather conditions. Users can also keep up to date with the status of filter and data processing, even before data are available on ARM’s Data Discovery. Users can contact INP mentors Jessie Creamean or Thomas Hill with any questions.

54 ENVIRONMENTAL SCIENCES↗

Dynamics of plankton populations in upwelling areas

There are no author-identified significant results in this report. Repeated coverage over the test site along the northwest coast of Africa showed that the structure of chlorophyll distribution is much more complicated than expected from continuous recordings. ERTS-1 data showed a very fast change in the chlorophyll distribution and it seems that also the concentration changes quickly. ERTS-1 showed on some frames offshore transportation of dust from the Sahara. All frames from Channel 7 will be arranged as a montage to derive the transportation pattern of dust. This step is important in biological aspects of interpreting ERTS-1 data, because the dissolution kinetics of eolian dust particles may influence significantly the chemistry of the surface water. Since visibility and the biochemistry of the test site off Africa are influenced by the dust transport, dust collection will be included in the ground truth program. Besides chlorophyll and other hydrographical parameters, the dust load in the test area will be measured. The collection plan is discussed along with a description of the high volume air sampler and the Anderson particle sizing head sampler to be used for the dust measurements.

Szekielda, K.↗

Use of Whatman-41 filters in air quality sampling networks (with applications to elemental analysis)

The operation of a 16-site parallel high volume air sampling network with glass fiber filters on one unit and Whatman-41 filters on the other is reported. The network data and data from several other experiments indicate that (1) Sampler-to-sampler and filter-to-filter variabilities are small; (2) hygroscopic affinity of Whatman-41 filters need not introduce errors; and (3) suspended particulate samples from glass fiber filters averaged slightly, but not statistically significantly, higher than from Whatman-41-filters. The results obtained demonstrate the practicability of Whatman-41 filters for air quality monitoring and elemental analysis.

Neustadter, H. E.↗

Electrets used to measure exhaust cloud effluents from Solid Rocket Motor (SRM) during demonstration model (DM-2) static test firing

Electrets were compared with fixed flow samplers during static test firing. The measurement of the rocket exhaust effluents by samplers and electrets indicated that the Solid Rocket Motor had no significant effect on the air quality in the area sampled. The results show that the electrets (a passive device which needs no power) can be used effectively alongside existing measuring devices (which need power). By placing electrets in areas where no power is available, measurements may be obtained. Consequently, it is a valuable complementary instrument in measuring rocket exhaust effluents in areas where other measuring devices may not be able to assess the contaminants.

Susko, M.↗

Wallops waveform analysis of SEASAT-1 radar altimeter data

Fitting a six parameter model waveform to over ocean experimental data from the waveform samplers in the SEASAT-1 radar altimeter is described. The fitted parameters include a waveform risetime, skewness, and track point; from these can be obtained estimates of the ocean surface significant waveheight, the surface skewness, and a correction to the altimeter's on board altitude measurement, respectively. Among the difficulties encountered are waveform sampler gains differing from calibration mode data, and incorporating the actual SEASAT-1 sampled point target response in the fitted wave form. There are problems in using the spacecraft derived attitude angle estimates, and a different attitude estimator is developed. Points raised in this report have consequences for the SEASAT-1 radar altimeter's ocean surface measurements are for the design and calibration of radar altimeters in future oceanographic satellites.

Hayne, G. S.↗

Sample fields of the Viking landers, physical properties, and aeolian processes

Surface sampler activities on Mars during the Viking extended mission are considered, including excavation of deep trenches, construction of conical piles of materials, backhoe touchdown experiments, and acquisition of contiguous pictures of the surface beneath number 2 terminal descent engines using mirrors. Results of the Physical Properties Investigation that are relevant to aeolian processes are also discussed. Both pictures and surface sampler data indicate that the surface materials in the sample fields of the Viking landers may be grouped, in order of increasing strength, into drift material, crusty to cloddy material, blocky material and rocks.

Moore, H. J.↗

Sea-state-related altitude errors in the Seasat radar altimeter

A significant waveheight-dependent bias is identified in Seasat-measured surface heights which cannot be neglected when using Seasat data at accuracies within 10 cm. Ten-second averages of the data from 63 waveform sampling rates in the Seasat radar altimeter were least squares fitted with a six-parameter model, the time-origin parameter of which provides a measure of the position of the actual mean radar waveform relative to the sampling rate and therefore provides altitude measurement corrections. Attention is given to actual altimeter point target response function, waveform sampler noise baseline, waveform sampler gain calibration, attitude angle and sea surface skewness, as effects not accounted for in Seasat altimeter measurements and standard data processing.

Hayne, G. S.↗

Batch Gas-Sampling System

Sampler collects air or other gases in consistent way and stabilizes them for later chemical analysis. Device used for concentrations ranging from few parts per million to 100 percent. Also separates and collects particles in gas for analysis. Gas flows into vacuum sphere when solenoid valve opened. As it passes through conversion tube, constituent of gas forms stable compound that remains in conversion tube for analysis at later time. Sampler parts made of glass, polytetrafluoroethylene, and stainless steel so they do not react with sample.

Diaz, Vernon, Jr.↗