Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sample preparation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Assessment and Non-Destructive Evaluation of the Influence of Residual Solvent on a Two-Part Epoxy-Based Adhesive Using Ultrasonics

Polymers are increasingly being used in higher demanding applications due to their ability to tailor the properties of structures while allowing for a weight and cost reduction. Solvents play an important role in the manufacture of polymeric structures since they allow for a reduction in the polymer’s viscosity or assist with the dispersion of fillers into the polymer matrix. However, the incorrect removal of the solvent affects both the physical and chemical properties of polymeric materials. The presence of residual solvent can also negatively affect the curing kinetics and the final quality of polymers. Destructive testing is mainly performed to characterize the properties of these materials. However, this type of testing involves using lab-type equipment that cannot be taken in-field to perform in situ testing and requires a specific sample preparation. Here, a method is presented to non-destructively evaluate the curing process and final viscoelastic properties of polymeric materials using ultrasonics. In this study, changes in longitudinal sound speed were detected during the curing of an aerospace epoxy adhesive as a result of variations in polymer chemistry. To simulate the presence of residual solvent, samples containing different weight percentages of isopropyl alcohol were manufactured and tested using ultrasonics. Thermogravimetric analysis was used to show changes in the decomposition of the adhesive due to the presence of IPA within the polymer structure. Adding 2, 4, and 6 wt.% of IPA decreased the adhesive’s lap shear strength by 40, 58, and 71%, respectively. Ultrasonics were used to show how the solvent influenced the curing process and the final sound speed of the adhesive. Young’s modulus and Poisson’s ratio were determined using both the longitudinal and shear sound speeds of the adhesive. Using ultrasonics has the potential to non-invasively characterize the quality of polymers in both an in-field and manufacturing settings, ensuring their reliability during use in demanding applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of Off-Stoichiometry on Electrical Conductivity in Ni-Fe and Mn-Co Spinel Systems

This study seeks to clarify the effects of off-stoichiometry on the electrical conductivity of spinels in the (Ni,Fe) 3 O 4 and (Mn,Co) 3 O 4 systems. Spinels with the compositions Ni x Fe 3–x O 4 (where x = 0.85, 0.875, 0.9, 1.0, 1.05, and 1.15) and Mn x Co 3–x O 4 (where x = 1.0, 1.2, 1.35, 1.5, 1.75, and 2.0) were prepared using conventional solid-state process. Electrical conductivity measurements were taken between 500 °C and 800 °C using the 4-point DC method. The conductivity in Ni-Fe spinels increased with increasing Fe content. Similarly, the conductivity of Mn-Co spinels increased drastically with increasing Co content. The coefficients of thermal expansion (CTEs) of these samples were also evaluated. All the (Ni,Fe) 3 O 4 spinels were found to exhibit excellent CTE matching with prospective stack components. However, thermal expansion characteristics were highly dependent on the composition in the (Mn,Co) 3 O 4 system, and only a narrow range of compositions was well-matched in CTE with prospective stack components. The significant effect of cation off-stoichiometry and sample preparation on the electrical behavior of spinels was discussed as a possible explanation for the large discrepancies in reported conductivity values for both systems.

08 HYDROGEN↗

Micro- to nano-scale areal heterogeneity in pore structure and mineral compositions of a sub-decimeter-sized Eagle Ford Shale

Mineral and organic matter compositions & pore structures of fine-grained shale influence reservoir properties. To improve the understanding of spatial heterogeneity in core-sized samples, methods of microscale X-ray fluorescence (μXRF) mapping, (ultra-) small-angle x-ray scattering [(U)SAXS] and wide-angle X-ray scattering (WAXS) have been used to determine elemental, pore-structure variations at scales up to ~10 cm on two samples prepared at circular and rectangular orientations from a piece of Eagle Ford Shale outcrop in South Texas, USA. In addition, thin section petrography and field emission-scanning electron microscopy observations, X-ray diffraction (XRD), total organic carbon, and pyrolysis were utilized to investigate the potential spatial heterogeneity of pore types, mineral and organic matter compositions for cm-sized samples at both orientations. Overall, the siliceous-carbonate mineral contents in these two samples (8 cm×8 cm×0.08 cm and 5 cm × 8 cm × 0.08 cm, in terms of width×length×thickness) of carbonate-rich Eagle Ford Shale vary between laminations at mm scales. For the circular sample, porosity and specific surface area (SSA) variations range from 0.82 to 3.04% and 1.51 to 14.1 m 2 /g, respectively. For the rectangular sample, values for porosity and SSA vary from 0.93 to 2.50% and 3.95 to 10.8 m 2 /g. By analyzing six selected sub-samples on each of two samples with (U)SAXS and XRD techniques, nm-sized pores are mainly interparticle ones in the higher calcite regions, where the porosity is also relatively lower, while the lower calcite regions consist of both interparticle and intraparticle pore types with higher porosity. Lastly, the μXRF and (U)SAXS mappings are combined to generate porosity distribution maps to provide more insights about sample heterogeneity related to the laminations and fractures at our observational scales.

58 GEOSCIENCES↗

GeoSoilEnviroCARS (Sector 13) at the Advanced Photon Source: a comprehensive synchrotron radiation facility for Earth science research at ambient and extreme conditions

GeoSoilEnviroCARS (GSECARS) is a comprehensive analytical laboratory for Earth and environmental science research using X-ray beams from the Advanced Photon Source, Argonne National Laboratory. State-of-the-art instruments are available for (1) high-pressure/high- or low-temperature diffraction, total scattering, and spectroscopy (Brillouin, Raman, and VIS-IR) using the laser heated diamond anvil cell (DAC); (2) high-pressure/high-temperature diffraction, scattering, and imaging as well as acoustic emission (AE) and ultrasonics using the large-volume press (LVP); (3) powder, single crystal, and surface/interface diffraction; (4) X-ray absorption fine structure spectroscopy; (5) X-ray fluorescence microprobe analysis; and (6) microtomography. As shown here, experiments are facilitated by senior level staff who collaborate on all aspects of the analytical work including experiment design, sample preparation, data collection, data interpretation, and publication preparation. Both technical and scientific synergies occur as a result of the intimate association of the various techniques and scientists experienced in the applications of synchrotron radiation to Earth, environmental, and planetary science problems. The facility includes state-of-the-art instrumentation designed and built in-house, including custom X-ray optics, online and offline laser-based systems, specialized sample environments and positioning systems, as well as pixel-array and multi-crystal energy dispersive X-ray detectors, which are available to be shared among the experimental stations.

36 MATERIALS SCIENCE↗

Silver-mediated separations: A comprehensive review on advancements of argentation chromatography, facilitated transport membranes, and solid-phase extraction techniques and their applications

The use of silver(I) ions in chemical separations, also known as argentation separations, is a powerful approach for the selective separation and analysis of many natural and synthetic organic compounds. In this review, a comprehensive discussion of the most common argentation separation techniques, including argentation-liquid chromatography (Ag-LC), argentation-gas chromatography (Ag-GC), argentation-facilitated transport membranes (Ag-FTMs), and argentation-solid phase extraction (Ag-SPE) is provided. For each of these techniques, notable advancements, optimized separations, and innovative applications are discussed. The review begins with an explanation of the fundamental chemistry underlying argentation separations, mainly the reversible π-complexation between silver(I) ions and carbon-carbon double bonds. Within Ag-LC, the use of silver(I) ions in thin-layer chromatography, high-performance liquid chromatography, as well as preparative LC are explored. This discussion focuses on how silver(I) ions are employed in the stationary and mobile phase to separate unsaturated compounds. For Ag-GC and Ag-FTMs, different silver compounds and supporting media are discussed, often with relation to olefin-paraffin separations. Ag-SPE has been widely employed for the selective extraction of unsaturated compounds from complex matrices in sample preparation. This comprehensive review of Ag-LC, Ag-GC, Ag-FTMs, and Ag-SPE techniques emphasizes the immense potential of argentation separations in separations science and serves as a valuable resource for researchers seeking to learn, optimize, and utilize argentation separations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Bio‐based glycerol plasticizers for flexible poly(vinyl chloride) blends

Abstract A series of glycerol‐based compounds were investigated for their application as plasticizers for flexible poly(vinyl chloride) (PVC) blends. The effect of plasticizer chemical structure on the performance, migration behavior, and blend morphology were evaluated and compared to blends produced using the commercial plasticizer dioctyl terephthalate (DOTP). Blends containing 40 phr (parts per hundred rubber) of glycerol‐based plasticizer showed a considerable reduction (between 54 to 86°C) in glass transition temperature ( T g ) relative to neat PVC ( T g ~ 80°C). Tensile testing of samples prepared with the glycerol analogs demonstrated higher ductility (elongation at break values of up to 97%) than DOTP (elongation at break value of 75%) at identical plasticizer loadings. The surface morphologies showed excellent incorporation of the glycerol plasticizers functionalized with alkyl chains longer than four carbons in length into the PVC matrix, whereas droplet formation was observed in blends with shorter chain glycerol derivatives. Leaching behavior of the plasticized samples were evaluated into different media and showed that plasticizers comprised of branched, or longer alkyl chains produced 2‐ to 4‐fold lower migration rates compared to those with shorter alkyl chains into polar solutions.

Halloran, Matthew W.↗

Automated High‐Throughput Fatigue Testing of Freestanding Thin Films

Abstract Mechanical testing at small length scales has traditionally been resource‐intensive due to difficulties with meticulous sample preparation, exacting load alignments, and precision measurements. Microscale fatigue testing can be particularly challenging due to the time‐intensive, tedious repetition of single fatigue experiments. To mitigate these challenges, this work presents a new methodology for the high‐throughput fatigue testing of thin films at the microscale. This methodology features a microelectromechanical systems‐based Si carrier that can support the simultaneous and independent fatigue testing of an array of samples. To demonstrate this new technique, the microscale fatigue behavior of nanocrystalline Al is efficiently characterized via this Si carrier and automated fatigue testing with in situ scanning electron microscopy. This methodology reduces the total testing time by an order of magnitude, and the high‐throughput fatigue results highlight the stochastic nature of the microscale fatigue response. This manuscript also discusses how this initial capability can be adapted to accommodate more samples, different materials, new geometries, and other loading modes.

Barrios, Alejandro↗

X-ray linear dichroic tomography of crystallographic and topological defects

Abstract The functionality of materials is determined by their composition 1–4 and microstructure, that is, the distribution and orientation of crystalline grains, grain boundaries and the defects within them 5,6 . Until now, characterization techniques that map the distribution of grains, their orientation and the presence of defects have been limited to surface investigations, to spatial resolutions of a few hundred nanometres or to systems of thickness around 100 nm, thus requiring destructive sample preparation for measurements and preventing the study of system-representative volumes or the investigation of materials under operational conditions 7–15 . Here we present X-ray linear dichroic orientation tomography (XL-DOT), a quantitative, non-invasive technique that allows for an intragranular and intergranular characterization of extended polycrystalline and non-crystalline 16 materials in three dimensions. We present the detailed characterization of a polycrystalline sample of vanadium pentoxide (V 2 O 5 ), a key catalyst in the production of sulfuric acid 17 . We determine the nanoscale composition, microstructure and crystal orientation throughout the polycrystalline sample with 73 nm spatial resolution. We identify and characterize grains, as well as twist, tilt and twin grain boundaries. We further observe the creation and annihilation of topological defects promoted by the presence of volume crystallographic defects. The non-destructive and spectroscopic nature of our method opens the door to operando combined chemical and microstructural investigations 11,18 of functional materials, including energy, mechanical and quantum materials.

Science & Technology - Other Topics↗

Methods for Quantitative Thermal Analysis of Lithium Solid-State and Beyond Battery Safety

The use of differential scanning calorimetry (DSC) to measure the thermal behavior of individual components and electrolyte/electrode combinations is common. However, here we focus on DSC tests on an anode, cathode, and electrolyte (ACE) component combination over a temperature range that includes many of the phase transitions and key reactions (i.e., to 500 °C) that contribute to thermal runaway. This method can help quantify the complex reaction network in a full cell, thereby informing potential safety issues. Here, we used DSC heat flow data from a solid-state Li 0.43 CoO 2 +C+PVDF | LLZO | Li metal ACE sample and its components to quantify key factors affecting results. We focused on three areas: (1) ACE sample preparation and assembly in DSC pans, (2) DSC measurement parameters, and (3) heat flow analysis. Key points include the choice of component ratios (e.g., commercially relevant N:P capacity ratio), the importance of conductive carbon and binder, type of pan used, DSC ramp rate, and integration method used when dealing with broad and overlapping exothermic peaks. This work deepens the scientific basis and best practices for obtaining heat flow data from ACE samples for early-stage evaluation of solid-state and beyond battery safety.

25 ENERGY STORAGE↗

Mapping of lanthanide-tagged proteins on western blot paper using microextraction-inductively coupled plasma-mass spectrometry

A microextraction (ME) sampling system, paired with inductively coupled plasma-mass spectrometry (ICP-MS), was employed to spatially analyze proteins tagged with lanthanum (La), gadolinium (Gd), or terbium (Tb) on the surface of western blot paper. The proteins were covalently tagged, separated via gel electrophoresis, and transferred to western blot paper for analysis by ME-ICP-MS. The ME-ICP-MS method enables the direct sampling of the tagged species on the western blot paper, without any sample preparation. Traditionally, the tagged analyte would need to be stained, excised, and digested to be analyzed by ICP-MS for its elemental and isotopic characterization. Preliminary detection limits for the ME-ICP-MS method applied to western blot paper were established to be 564, 54, and 2.5 fg for La, Gd, and Tb, respectively. The developed ME-ICP-MS method was compared to laser ablation (LA) ICP-MS, another direct solid sampling technique; it was readily determined that ME-ICP-MS can effectively map the elemental constituents on the western blot paper with comparable analysis time and measurement sensitivity. The analysis time per 2 × 4 mm extraction is ∼1 minute; if protein spots are directly targeted (rather than systematically mapping the entire blot paper), the analysis time per protein spot is ∼1 min. This developed method proved to be fast, effective, and accessible for correlating protein molecular weight with the detection of the inorganic tagant. The ME-ICP-MS approach could be widely applicable in research areas that involve metal-tagged protein bioconjugates, such as in the development of diagnostic and therapeutic agents and other biochemical probes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Micro-tensile characteristics of As-fabricated and irradiated AGR-2 TRISO fuel particle buffer, IPyC, and buffer-IPyC interlayer regions

A recently developed micro-tensile sample preparation technique was implemented to evaluate the tensile strengths of the buffer, IPyC, and buffer-IPyC interlayer regions of the unirradiated and irradiated AGR-2 TRISO fuel particles. Understanding the mechanical properties of the buffer-IPyC interlayer is essential for developing thermomechanical models of buffer-IPyC separation, yet there is a lack of experimental data on its micro-tensile properties. TEM analysis was conducted on these regions to determine the microstructural changes relevant to the samples' tensile properties. In the unirradiated TRISO particle samples, the buffer layer demonstrated the weakest tensile strength, while the IPyC layer exhibited the highest. Conversely, in the irradiated TRISO particle samples, the buffer-IPyC interlayer region showed the lowest tensile strength, with the IPyC layer being the strongest. Fractures in the samples from the buffer-IPyC region predominantly occurred either in the buffer layer or at the buffer-IPyC interface. However, some buffer-IPyC interlayer samples displayed stress-strain and fracture behaviors more akin to the IPyC layer than the buffer layer. Analysis of diffraction patterns suggests that irradiation may have increased anisotropy in the three regions tested. Despite this suggested increase in anisotropy, there was no evidence that it affected the measured strengths. The irradiated TRISO particles demonstrated a considerable increase in void space and a decrease in ultimate tensile strength within the buffer-IPyC interlayer region due to the densification and contraction of the buffer layer. Minor variations in diffraction ring patterns were also observed. These changes, coupled with a significant reduction in the Weibull modulus/shape parameter, imply that irradiation-induced densification leads to tearing between the buffer and IPyC layers at locations of elevated porosity in the buffer-IPyC interlayer region.

Tristructural isotropic (TRISO)↗

High-Energy X-ray Diffraction Microscopy for Nuclear Forensics (FY23 Project Report)

Morphological information on nuclear material has been identified using visible light and scanning electron microscopy. These identify qualitative differences in particle morphology. Three-dimensional imaging of materials through alternating scanning electron microscopy imaging and focused ion beam milling has also been used. Unfortunately, these techniques are time- and labor-intensive, with significant sample preparation required and lengthy analysis times. Further, the resulting 3D images are qualitative, require manual identification, and do not capture statistically-representative populations. High energy X-ray 3D imaging using a direct-beam or diffracted-beam (High-Energy Diffraction Microscopy) have been developed at the Advanced Photon Source and can produce quantitative information on grains (phase, location, etc.) and pores (size distribution, sphericity) in a material. These techniques require only minutes to characterize a sample volume and are non-destructive, thus suitable for a wide range of existing samples and for confirmatory analyses to be carried out using conventional microscopy techniques.

36 MATERIALS SCIENCE↗

Benchmarking of X‐Ray Fluorescence Microscopy with Ion Beam Implanted Samples Showing Detection Sensitivity of Hundreds of Atoms

Abstract Single impurities in insulators are now often used for quantum sensors and single photon sources, while nanoscale semiconductor doping features are being constructed for electrical contacts in quantum technology devices, implying that new methods for sensitive, non‐destructive imaging of single‐ or few‐atom structures are needed. X‐ray fluorescence (XRF) can provide nanoscale imaging with chemical specificity, and features comprising as few as 100 000 atoms have been detected without any need for specialized or destructive sample preparation. Presently, the ultimate limits of sensitivity of XRF are unknown – here, gallium dopants in silicon are investigated using a high brilliance, synchrotron source collimated to a small spot. It is demonstrated that with a single‐pixel integration time of 1 s, the sensitivity is sufficient to identify a single isolated feature of only 3000 Ga impurities (a mass of just 350 zg). With increased integration (25 s), 650 impurities can be detected. The results are quantified using a calibration sample consisting of precisely controlled numbers of implanted atoms in nanometer‐sized structures. The results show that such features can now be mapped quantitatively when calibration samples are used, and suggest that, in the near future, planned upgrades to XRF facilities might achieve single‐atom sensitivity.

36 MATERIALS SCIENCE↗

Methods for ultraviolet excitation microscopy of biological surfaces

Microscopy with Ultraviolet Surface Excitation (MUSE) for use in the classroom to enhance life sciences education and curricula, or for other applications, including without limtiation the operating room, other medical environments, research environments, and low resource environments. MUSE's suitability is based on multiple key factors including its simplicity of use, the incorporation of inexpensive hardware including LED illumination, and very basic tissue preparation. The ultraviolet excitation acts as passive optical sectioning confining the generated fluorescence signal to only a few micrometers below the tissue surface thus eliminating the out of focus signals. This facilitates image capture of tissue microstructure and organization from specimens at the intact or sliced surface arising from varying fluorophore concentration within the different cellular compartments. Although just the tissue auto fluorescence maybe used, image quality is enhanced with brief application of nontoxic fluorescent dyes to selectively highlight cellular compartments. Sample preparation is safe, efficient and familiar to students with basic chemistry or biology lab experience. Mixed-dye powders may be used to simplify translation of this method for educational, medical, research, low resource, and other settings.

Demos, Stavros G.↗

Np-237 LoD Measurement by TIMS-Multi-Ion Counting Total Evaporation [Poster]

Requests for ultra-low-level 237 Np analyses highlight the importance of a robust chemical purification and measurement technique for Np. In FY2022, LANL is quantifying the instrumental 237 Np LoD. Need to incorporate a chemical purification procedure for TIMS-MICTE sample preparation. What is the recovery of the chemical purification procedure? What is the ultimate detection limit that can be achieved while incorporating a chemical purification procedure? We have adapted and refined the Pu TIMS-MICTE method for Np analyses. We have determined expected uncertainties for 237 Np TIMS-MICTE measurements. We have increased sensitivity through technique improvements. We have improved method reliability for Np analyses and increased throughput. Apply knowledge gained from progress made in FY2022 to further develop Np sample purification and analyses by TIMSMICTE.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comprehensive Study of the Potential of Extracting and Processing Critical Minerals from Coal-Based Resources - Phase I

The Phase I report prepared for the Department of Energy addresses U.S. Executive Order 13817 titled A Federal Strategy to Ensure Secure and Reliable Supplies of Critical Minerals, issued on December 20, 2017, that lists 35 critical minerals that are vulnerable to supply disruption. A comprehensive review of each of the minerals was conducted to determine the criticality based primarily on extractability from coal-based resources. Several other factors were also considered such as gaps in supply and demand, use in current technology, and the existence of viable substitutes. It was determined that the critical minerals that show highest potential for extraction from coal-based resources are lithium, rare earth elements (REEs), cobalt, and manganese. All four of the critical minerals listed serve an important role in the technology industry, have few substitutes, and have a heavy import reliance. Most notably are lithium, which is widely used in the electric vehicle industry, and the REEs which can be found in virtually all electronic devices. The research of critical mineral extraction from coal-based resources was completed using a combination of literature review from public sources as well as cooperation from coal mines and power plants across the United States. Samples collected from six different geographical locations across the U.S. were subjected to sample preparation (i.e., pH measurement, moisture content, particle size analysis) and characterization studies using Inductively Coupled Plasma-Mass Spectroscopy (ICP-MS) and Scanning Electron Microscopy, Energy Dispersive X-Ray Spectroscopy (SEM-EDX) instruments. 27 samples of coal waste materials such as refuse, sludge, and fly ash were tested to characterize the rare earth element concentration by total rare earth elements (TREEs), heavy rare earth elements (HREEs), and light rare earth elements (LREEs). Of the 27 samples tested, 22 contained a TREE concentration higher than the threshold of 300 ppm, which is considered a viable feedstock material. 3 samples contained less than 300 ppm of TREEs; however, they were within 20 ppm of the threshold, and could potentially be considered viable sources in the future pending the advancement of more efficient extraction technologies. 2 of the 27 samples had significantly low TREE concentrations, which does not imply any potential for being a source for REEs. For the minerals identified as most critical in the literature review, a conceptual process flow diagram (PFD) was developed for their extraction from different coal-based feedstocks. The process targets selective recovery of one commodity (i.e., rare earths, lithium, cobalt, and manganese) via several hydrometallurgical separation methods. By identifying potentially extractable coal-based critical mineral resources, a study of the current and future market environments for each critical mineral, and a review of current processing methodologies for critical mineral extraction from coal-based resources, the foundation has been laid to further characterize and explore new resources and extraction techniques. As reliance on technologies in industries such as the production of electronic devices, batteries, and alloys containing critical minerals utilizing critical minerals continues to increase, a sound understanding of our nation’s dependence on and even the global criticality of certain critical minerals, will serve as a catalyst for innovation in virtually all fields of science.

01 COAL, LIGNITE, AND PEAT↗

An international laboratory comparison of dissolved organic matter composition by high resolution mass spectrometry: Are we getting the same answer?

Since the first detailed compositional analysis of dissolved organic matter (DOM) in 1995, high resolution mass spectrometry (HRMS) has become a vital tool for DOM characterization. While the upward trend in HRMS for molecular level analysis of DOM continues, so do the challenges of data comparison and interpretation between laboratories operating instruments of differing performance and user operating conditions. It is therefore essential that the community establishes whether data and trends can be compared robustly between research groups. To this end, 4 identically prepared DOM samples were each studied by 16 laboratories, representing 17 commercially-purchased instruments located across 8 countries, using positive- and negative-mode electrospray ionization (ESI) HRMS analysis. Despite the widely reported sensitivity of ESI experiments to sample matrix, preparation, ion source operation and instrument tuning parameters, the instruments used in this study showed relatively low variability between results for the same samples, particularly H/C and AI metrics. The variation in O/C and m/z metrics was relatively higher, although z-score graphs and %BCD demonstrated that the relative difference in general chemical composition between samples was the same for each instrument included in the study. As such, these metrics can be used for fingerprinting of DOM samples and as a benchmark for quality control in participating laboratories, with future strides in environmental science building upon these efforts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Regioselective Generation of Single‐Site Iridium Atoms and Their Evolution into Stabilized Subnanometric Iridium Clusters in MWW Zeolite

Abstract Preparation of supported metal catalysts with uniform particle size and coordination environment is a challenging and important topic in materials chemistry and catalysis. In this work, we report the regioselective generation of single‐site Ir atoms and their evolution into stabilized subnanometric Ir clusters in MWW zeolite, which are located at the 10MR window connecting the two neighboring 12MR supercages. The size of the subnanometric Ir clusters can be controlled by the post‐synthesis treatments and maintain below 1 nm even after being reduced at 650 °C, which cannot be readily achieved with samples prepared by conventional impregnation methods. The high structure sensitivity, size‐dependence, of catalytic performance in the alkane hydrogenolysis reaction of Ir clusters in the subnanometric regime is evidenced.

Liu, Lichen↗