Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “rotating target”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Selection of Target Thickness and Size of Drive Electron Beam for Ce+BAF Injector

A baseline concept for a continuous wave (CW) polarized positron injector was developed for the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. This concept is based on the generation of CW longitudinally polarized positrons by a high-current, polarized electron beam (1 mA, 130-370 MeV, and 90% longitudinal polarization) that passes through a rotating, water-cooled, tungsten target. The positron yield and longitudinal polarization are calculated for the 123 MeV Ce+BAF injector at the Low Energy Recirculator Facility (LERF). The longitudinal and transverse CEBAF acceptances, defined as an energy spread of less than 1% and a normalized emittance of less than 100 mm·mrad, have been used in these calculations. The impact of target thickness, transverse electron beam size, and electron beam energy on the yield and polarization of a positron injector is evaluated. The total energy deposited by the beams in the tungsten target and the peak energy density are calculated for different target thicknesses, electron beam sizes, and energies.

Ushakov, Andriy [Thomas Jefferson National Acceler↗

The dosimetric impact of daily setup error on target volumes and surrounding normal tissue in the treatment of prostate cancer with intensity-modulated radiation therapy

The purpose of this study was to evaluate the impact of daily setup error and interfraction organ motion on the overall dosimetric radiation treatment plans. Twelve patients undergoing definitive intensity-modulated radiation therapy (IMRT) treatments for prostate cancer were evaluated in this institutional review board-approved study. Each patient had fiducial markers placed into the prostate gland before treatment planning computed tomography scan. IMRT plans were generated using the Eclipse treatment planning system. Each patient was treated to a dose of 8100 cGy given in 45 fractions. In this study, we retrospectively created a plan for each treatment day that had a shift available. To calculate the dose, the patient would have received under this plan, we mathematically 'negated' the shift by moving the isocenter in the exact opposite direction of the shift. The individualized daily plans were combined to generate an overall plan sum. The dose distributions from these plans were compared with the treatment plans that were used to treat the patients. Three-hundred ninety daily shifts were negated and their corresponding plans evaluated. The mean isocenter shift based on the location of the fiducial markers was 3.3 {+-} 6.5 mm to the right, 1.6 {+-} 5.1 mm posteriorly, and 1.0 {+-} 5.0 mm along the caudal direction. The mean D95 doses for the prostate gland when setup error was corrected and uncorrected were 8228 and 7844 cGy (p < 0.002), respectively, and for the planning target volume (PTV8100) was 8089 and 7303 cGy (p < 0.001), respectively. The mean V95 values when patient setup was corrected and uncorrected were 99.9% and 87.3%, respectively, for the PTV8100 volume (p < 0.0001). At an individual patient level, the difference in the D95 value for the prostate volume could be >1200 cGy and for the PTV8100 could approach almost 2000 cGy when comparing corrected against uncorrected plans. There was no statistically significant difference in the D35 parameter for the surrounding normal tissue except for the dose received by the penile bulb and the right hip. Our dosimetric evaluation suggests significant underdosing with inaccurate target localization and emphasizes the importance of accurate patient setup and target localization. Further studies are needed to evaluate the impact of intrafraction organ motion, rotation, and deformation on doses delivered to target volumes.

61 RADIATION PROTECTION AND DOSIMETRY↗

Effects of adaptation of vestibulo-ocular reflex function on manual target localization

The goal of the present study was to determine if adaptive modulation of vestibulo-ocular reflex (VOR) function is associated with commensurate alterations in manual target localization. To measure the effects of adapted VOR on manual responses we developed the Vestibular-Contingent Pointing Test (VCP). In the VCP test, subjects pointed to a remembered target following passive whole body rotation in the dark. In the first experiment, subjects performed VCP before and after wearing 0.5X minifying lenses that adaptively attenuate horizontal VOR gain. Results showed that adaptive reduction in horizontal VOR gain was accompanied by a commensurate change in VCP performance. In the second experiment, bilaterally labyrinthine deficient (LD) subjects were tested to confirm that vestibular cues were central to the spatial coding of both eye and hand movements during VCP. LD subjects performed significantly worse than normal subjects. These results demonstrate that adaptive change in VOR can lead to alterations in manual target localization.

NASA Center JSC↗

Monte Carlo calculation of helical tomotherapy dose delivery

Helical tomotherapy delivers intensity modulated radiation therapy using a binary multileaf collimator (MLC) to modulate a fan beam of radiation. This delivery occurs while the linac gantry and treatment couch are both in constant motion, so the beam describes, from a patient/phantom perspective, a spiral or helix of dose. The planning system models this continuous delivery as a large number (51) of discrete gantry positions per rotation, and given the small jaw/fan width setting typically used (1 or 2.5 cm) and the number of overlapping rotations used to cover the target (pitch often <0.5), the treatment planning system (TPS) potentially employs a very large number of static beam directions and leaf opening configurations to model the modulated fields. All dose calculations performed by the system employ a convolution/superposition model. In this work the authors perform a full Monte Carlo (MC) dose calculation of tomotherapy deliveries to phantom computed tomography (CT) data sets to verify the TPS calculations. All MC calculations are performed with the EGSnrc-based MC simulation codes, BEAMnrc and DOSXYZnrc. Simulations are performed by taking the sinogram (leaf opening versus time) of the treatment plan and decomposing it into 51 different projections per rotation, as does the TPS, each of which is segmented further into multiple MLC opening configurations, each with different weights that correspond to leaf opening times. Then the projection is simulated by the summing of all of the opening configurations, and the overall rotational treatment is simulated by the summing of all of the projection simulations. Commissioning of the source model was verified by comparing measured and simulated values for the percent depth dose and beam profiles shapes for various jaw settings. The accuracy of the MLC leaf width and tongue and groove spacing were verified by comparing measured and simulated values for the MLC leakage and a picket fence pattern. The validated source and MLC configuration were then used to simulate a complex modulated delivery from fixed gantry angle. Further, a preliminary rotational treatment plan to a delivery quality assurance phantom (the 'cheese' phantom) CT data set was simulated. Simulations were compared with measured results taken with an A1SL ionization chamber or EDR2 film measurements in a water tank or in a solid water phantom, respectively. The source and MLC MC simulations agree with the film measurements, with an acceptable number of pixels passing the 2%/1 mm gamma criterion. 99.8% of voxels of the MC calculation in the planning target volume (PTV) of the preliminary plan passed the 2%/2 mm gamma value test. 87.0% and 66.2% of the voxels in two organs at risk (OARs) passed the 2%/2 mm tests. For a 3%/3 mm criterion, the PTV and OARs show 100%, 93.2%, and 86.6% agreement, respectively. All voxels passed the gamma value test with a criterion of 5%/3 mm. The TomoTherapy TPS showed comparable results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Visual Performance Challenges to Low-Frequency Perturbations After Long-Duration Space Flight, and Countermeasure Development

Astronauts experience sensorimotor disturbances after long-duration space flight. After a water landing, crewmembers may need to egress the vehicle within a few minutes for safety and operational reasons in various sea state conditions. Exposure to even low-frequency motions induced by sea conditions surrounding a vessel can cause significant motor control problems affecting critical functions. The first objective of this study was to document human visual performance during simulated wave motion below 2.0 Hz. We examined the changes in accuracy and reaction time when subjects performed a visual target acquisition task in which the location of the target was offset vertically during horizontal rotation at an oscillating frequency of 0.8 Hz. The main finding was that both accuracy and reaction time varied as a function of target location, with greater performance decrements occurring when vertical targets were acquired at perturbing frequencies of 0.8 Hz in the horizontal plane. A second objective was to develop a countermeasure, base d on stochastic resonance (SR), to enhance sensorimotor capabilities with the aim of facilitating rapid adaptation to gravitational transitions after long-duration space flight. SR is a mechanism by which noise can enhance the response of neural systems to relevant sensory signals. Recent studies have shown that applying imperceptible stochastic electrical stimulation to the vestibular system (SVS) significantly improved balance and oculomotor responses. This study examined the effectiveness of SVS on improving balance performance. Subjects performed a standard balance task while bipolar SVS was applied to the vestibular system using constant current stimulation through electrodes placed over the mastoid process. The main finding of this study was that balance performance with the application of SR showed significant improvement in the range of 10%-25%. Ultimately an SR-based countermeasure might be fielded either as preflight training to enhance adaptability, or as a miniature patch-type stimulator worn post flight.

Mulavara, Ajitkumar↗

A proposed definition for a pitch attitude target for the microburst escape maneuver

The Windshear Training Aid promulgated by the Federal Aviation Administration (FAA) defines the practical recovery maneuver following a microburst encounter as application of maximum thrust accompanied by rotation to an aircraft-specific target pitch attitude. In search of a simple method of determining this target, appropriate to a variety of aircraft types, a computer simulation was used to explore the suitability of a pitch target equal in numerical value to that of the angle of attack associated with stall warning. For the configurations and critical microburst shears simulated, this pitch target was demonstrated to be close to optimum.

Bray, Richard S.↗

The Dosimetric Impact of Prostate Rotations During Electromagnetically Guided External-Beam Radiation Therapy

Purpose: To study the impact of daily rotations and translations of the prostate on dosimetric coverage during radiation therapy (RT). Methods and Materials: Real-time tracking data for 26 patients were obtained during RT. Intensity modulated radiation therapy plans meeting RTOG 0126 dosimetric criteria were created with 0-, 2-, 3-, and 5-mm planning target volume (PTV) margins. Daily translations and rotations were used to reconstruct prostate delivered dose from the planned dose. D{sub 95} and V{sub 79} were computed from the delivered dose to evaluate target coverage and the adequacy of PTV margins. Prostate equivalent rotation is a new metric introduced in this study to quantify prostate rotations by accounting for prostate shape and length of rotational lever arm. Results: Large variations in prostate delivered dose were seen among patients. Adequate target coverage was met in 39%, 65%, and 84% of the patients for plans with 2-, 3-, and 5-mm PTV margins, respectively. Although no correlations between prostate delivered dose and daily rotations were seen, the data showed a clear correlation with prostate equivalent rotation. Conclusions: Prostate rotations during RT could cause significant underdosing even if daily translations were managed. These rotations should be managed with rotational tolerances based on prostate equivalent rotations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-D-18A-07: Towards 6-Degree-Of-Freedom Real-Time Motion Management in Cancer Radiotherapy

Purpose: Lung tumor motion has been identified as a major issue that deteriorates treatment efficacy for radiotherapy, especially for SBRT. As tighter PTV margins are applied due to translational compensation, tumor rotation will become the dominant factor limiting tumor targeting accuracy. This is the world-first study quantifies lung tumor rotation by utilizing kV images with fiducial markers and a step towards 6-degree-of-freedom real-time cancer radiotherapy. Methods: Three or four gold coils were implanted as tumor surrogates in 3 lung cancer patients. 50 fractions of 8- minute, 10 Hz 4D CBCT projections were acquired for the patients immediately prior or after radiotherapy. The fiducial marker positions are segmented, reconstructed and used to determine tumour rotation by the iterative closest point algorithm. Different data acceptance and filtering methods were applied to accept data or smooth the marker trajectory. Results: The average rotation angles around the left/ right (LR), superior/inferior (SI), anterior/posterior (AP) rotations were found to be 0.8±4.2, -0.8±4.5 and 1.7±3.1 degrees respectively. For 28% of the treatment time, the lung tumors rotated more than 5° around the SI axis. Respiration-induced rotational motion was detected in 2 of the 3 lung patients. This can be explained by the patient developed atelectasis during the treatment period. Interestingly, no heart beating component of rotation was observed in the power spectrum. Different rotational types were observed within the patient cohort with large variations in the magnitude of the rotation between patients. Conclusions: For the first time, continuous tumor rotation has been measured for lung patients with gold fiducial markers. Tumors were found to undergo rotations of more than 5° for almost a third of the total treatment time. The study also demonstrated the feasibility of using continuously kV images for real-time lung tumour motion adaptive radiotherapy which can potentially reduce treatment margins and side effects. The authors acknowledge the financial support of an NHMRC Australia Fellowship.

60 APPLIED LIFE SCIENCES↗

K2 ROTATION PERIODS FOR LOW-MASS HYADS AND THE IMPLICATIONS FOR GYROCHRONOLOGY

As the closest open cluster to the Sun, the Hyades is an important benchmark for many stellar properties, but its members are also scattered widely over the sky. Previous studies of stellar rotation in the Hyades relied on targeted observations of single stars or data from shallower all-sky variability surveys. The re-purposed Kepler mission, K2 , is the first opportunity to measure rotation periods ( P {sub rot}) for many Hyads simultaneously while also being sensitive to fully convective M dwarf members. We analyze K2 data for 65 Hyads and present P {sub rot} values for 48. Thirty-seven of these are new measurements, including the first P {sub rot} measurements for fully convective Hyads. For 9 of the 11 stars with P {sub rot} in the literature and this work, the measurements are consistent; we attribute the two discrepant cases to spot evolution. Nearly all stars with masses ≲0.3 M {sub ⊙} are rapidly rotating, indicating a change in rotation properties at the boundary to full convection. When confirmed and candidate binaries are removed from the mass–period plane, only three rapid rotators with masses ≳0.3 M {sub ⊙} remain. This is in contrast to previous results showing that the single-valued mass–period sequence for ≈600 Myr old stars ends at ≈0.65 M {sub ⊙} when binaries are included. We also find that models of rotational evolution predict faster rotation than is actually observed at ≈600 Myr for stars ≲0.9 M {sub ⊙}. The dearth of single rapid rotators more massive than ≈0.3 M {sub ⊙} indicates that magnetic braking is more efficient than previously thought, and that age–rotation studies must account for multiplicity.

79 ASTRONOMY AND ASTROPHYSICS↗

THE CLOSE T TAURI BINARY SYSTEM V4046 Sgr: ROTATIONALLY MODULATED X-RAY EMISSION FROM ACCRETION SHOCKS

We report initial results from a quasi-simultaneous X-ray/optical observing campaign targeting V4046 Sgr, a close, synchronous-rotating classical T Tauri star (CTTS) binary in which both components are actively accreting. V4046 Sgr is a strong X-ray source, with the X-rays mainly arising from high-density (n{sub e}{approx} 10{sup 11}-10{sup 12} cm{sup -3}) plasma at temperatures of 3-4 MK. Our multi-wavelength campaign aims to simultaneously constrain the properties of this X-ray-emitting plasma, the large-scale magnetic field, and the accretion geometry. In this paper, we present key results obtained via time-resolved X-ray-grating spectra, gathered in a 360 ks XMM-Newton observation that covered 2.2 system rotations. We find that the emission lines produced by this high-density plasma display periodic flux variations with a measured period, 1.22 {+-} 0.01 d, that is precisely half that of the binary star system (2.42 d). The observed rotational modulation can be explained assuming that the high-density plasma occupies small portions of the stellar surfaces, corotating with the stars, and that the high-density plasma is not azimuthally symmetrically distributed with respect to the rotational axis of each star. These results strongly support models in which high-density, X-ray-emitting CTTS plasma is material heated in accretion shocks, located at the base of accretion flows tied to the system by magnetic field lines.

79 ASTRONOMY AND ASTROPHYSICS↗

Influence of tumor location on the intensity-modulated radiation therapy plan of helical tomotherapy

Given the design of the Helical TomoTherapy device, the patient's central axis is routinely aligned with the machine's rotational axis to prevent the patient's body from colliding with the machine walls. However, for treatment of tumors located away from the patient's central axis, this position may not be optimal as the adequate radiation dose may not reach the affected site. Our study aimed to investigate the influence of tumor location on dose quality and delivery efficiency of tomotherapy plans. A phantom and 15 patients were selected for this study. Two plans, A and B, were implemented for each case. In plan A, the patient's central axis was aligned with the machine's rotational axis, whereas in plan B, the center of the planning target volume (PTV) was aligned with the machine's rotational axis. Both plans were optimized with the same planning parameters, and the dose quality of the plans was evaluated using dosimetrics. The delivery efficiency was determined from delivery time and monitor units (MUs). A paired t-test or nonparametric Wilcoxon signed-rank test was performed for statistical comparison. In the phantom study, the median delivery times were 358 and 336 seconds for plans A and B, respectively, and this difference was significant (p = 0.005). In the patient study, the median delivery times were 348 and 317 seconds for plans A and B, respectively, and this difference was also significant (p = 0.001). The dose qualities of both plans for each patient were nearly identical. No significant differences were found in the conformal index, heterogeneity index, and mean dose delivered to normal tissue between the plans. Both phantom and patient studies showed that for normal-sized patients, the delivery time reduced as the distance between the PTV and the patient's central axis increased when the PTV center was aligned with the machine axis. In conclusion, aligning the PTV center with the machine's rotational axis by shifting the patient during tomotherapy reduces the delivery time without compromising the dose quality of intensity-modulated radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Translational Vestibulo-Ocular Reflexes During Off-Vertical Axis Rotation

The translational vestibulo-ocular reflex (tVOR) is an otolith-mediated response that stabilizes near vision during linear acceleration at higher frequencies where visually mediated reflexes are not adequate. The modulation of horizontal and vergence eye movements during Off-Vertical Axis Rotation (OVAR) are presumed to reflect the tVOR in response to the continuously varying linear acceleration in the interaural and nasooccipital axes, respectively. The purpose of this study was to examine the effect of frequency and fixation distance on the modulation of slow phase eye velocity (SPV) as further evidence that the tVOR is elicited during OVAR. Eighteen subjects were rotated about their longitudinal axis tilted by 30 deg off-vertical. Rotational velocities varied between 18 and 288 deg/sec corresponding to a frequency range of 0.05 to 0.8 Hz. Fixation distance was altered by asking subjects to imagine stationary targets that were briefly presented at 0.5, 1 and 2 m during some rotation cycles. The target flash was 40 msec in the nose-up position at eye level. Oculomotor responses were recorded in the dark using infrared binocular videography. Sinusoidal curve fits were used to derive amplitude, phase and bias velocity of the eye movements across multiple rotation cycles. Consistent with previous studies, the modulation of both horizontal and vergence SPV increased with stimulus frequency. The effect of fixation distance was negligible at lower frequencies. The modulation of horizontal and vergence SPV was; however, proportional to fixation distance during OVAR at 0.8 Hz. This increasing sensitivity and dependence on fixation distance of horizontal and vergence SPV during OVAR is consistent with tVOR characteristics measured during other types of linear motion. We conclude that the modulation of horizontal and vergence SPV will be diagnostically more useful at higher stimulus frequencies where the tVOR is more robust.

Wood, Scott J.↗

Challenges and design solutions of the liquid hydrogen circuit at the European Spallation Source

The European Spallation Source (ESS), Lund, Sweden will be a 5MW long-pulse neutron spallation research facility and will enable new opportunities for researchers in the fields of life sciences, energy, environmental technology, cultural heritage and fundamental physics. Neutrons are produced by accelerating a high-energy proton beam into a rotating helium-cooled tungsten target. These neutrons pass through moderators to reduce their energy to an appropriate range (< 5 meV for cold neutrons); two of which will use liquid hydrogen at 17 K as the moderating and cooling medium. There are several technical challenges to overcome in the design of a robust system that will operate under such conditions, not least the 20 kW of deposited heat. These challenges and the associated design solutions will be detailed in this paper.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Shape, colour, and distance in weak gravitational flexion

ABSTRACT Canonically, elliptical galaxies might be expected to have a perfect rotational symmetry, making them ideal targets for flexion studies – however, this assumption has not been tested. We have undertaken an analysis of low- and high-redshift galaxy catalogues of known morphological type with a new gravitational lensing code, Lenser. Using colour measurements in the u − r bands and fit Sérsic index values, objects with characteristics consistent with early-type galaxies are found to have a lower intrinsic scatter in flexion signal than late-type galaxies. We find this measured flexion noise can be reduced by more than a factor of two at both low and high redshift.

Fabritius II, Joseph M.↗

Simulations of positron injector for Ce+BAF

A baseline concept for a continuous wave (CW) polarized positron injector was developed for the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. This concept is based on the generation of CW longitudinally polarized positrons by a high-current, polarized electron beam (1 mA, 130‑370 MeV, and 90% longitudinal polarization) that passes through a rotating, water-cooled, tungsten target. The simulation results for the Ce+BAF injector at the Low Energy Recirculator Facility (LERF) are presented, including positron beam generation, capture, energy selection, and acceleration to 123 MeV. The positron yield (or positron current) and longitudinal polarization are calculated considering the longitudinal and transverse CEBAF acceptances (<1% energy spread, <1 mm bunch length and normalized emittance of <100 mm mrad). The impact of target thickness, drive electron beam energy, and transverse size on positron yield within the required emittance limit is evaluated.

Accelerator Physics↗

Positron Injector for Ce+BAF

A baseline concept for a continuous wave (CW) polarized positron injector was developed for the CEBAF at Jefferson Lab. This concept is based on the generation of CW longitudinally polarized positrons by a high-current, polarized electron beam 1 mA, 130-370 MeV, and 90% longitudinal polarization that passes through a rotating, water-cooled, tungsten target. The simulations for the Ce+BAF injector at the Low Energy Recirculator Facility (LERF) are performed, including positron beam generation, capture, energy selection, and acceleration to 123 MeV. The positron yield (or positron current) and longitudinal polarization are calculated considering the longitudinal and transverse CEBAF acceptances (<1% energy spread, 1.2 mm bunch length and normalized emittance of 100 mm·mrad). The impact of target thickness, electron beam energy, and transverse size on positron yield within the required emittance limit is evaluated. Target thermal and structural FEM analyses (ANSYS Fluent) are performed to determine the maximum electron beam current and minimum transverse beam size on the target.

Benesch, Jay [Thomas Jefferson National Accelerato↗

Polarized positrons at Ce\(^+\)BAF

A baseline concept for a continuous wave (CW) polarized positron injector was developed for the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab [1]. This concept is based on positron beam generation by a high current polarized electron beam (1 mA, 120 MeV, >85% polarization) irradiating a 4 mm thick rotating water-cooled tungsten target or liquid metal target. The update on the development of the Ce+BAF injector concept including the polarized electron source, the development of high power targets, simulations of positron capture, the design of the transport line from the positron injector to the CEBAF North Linac and the planned experiment to measure the upper limits of transverse and longitudinal emittances accepted by the 12 GeV CEBAF optics are presented. [1] J. Grames et al., "Positron beams at Ce+BAF", in Proc. 14th Int. Particle Accelerator Conf. (IPAC’23), Venice, Italy, MOPL152, pp. 896–899 (2023). doi:10.18429/JACoW-IPAC2023-MOPL152

Ushakov, Andriy↗

Mechanisms of UK radiometers flown on Nimbus 5 and 6 with particular reference to bearings, pivots and lubrication

The mechanisms incorporated in the vertical sounding infrared radiometry experiments which were launched on Nimbus 5 in 1972 and on Nimbus 6 in 1975 are discussed. Both use dry lubricants. The Nimbus 5 radiometer includes a rotating chopper driven via a carbon fiber-acetal resin gearwheel. The driving motor runs at 2000 rpm and has completed over 7 x 10 to the 9th power revolutions. Four gear driven filter wheels powered by stepper motors have each completed 2 x 10 to the 8th power changes. The input calibration mirror mechanism and its field of view compensation mechanisms are also described. All 25 ball races used in the experiment are of the film transfer type. The Nimbus 6 radiometer includes two cells. Each contains a piston supported on diaphragm springs and driven electromagnetically. The pistons are 6 cm in diameter with a stroke of 1 cm and are driven at their mechanical resonant frequency of approx. 15 Hz. The calibrating mirrors rotate periodically to view a target. The support pivots are synthetic sapphire ring stones with separate end thrust stones. The problems of mounting these stones to withstand vibration loads is described.

Hadley, H.↗