Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “receiver synchronization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Flexible Data and Frame Synchronization Structure for the LunaNet PNT Signal

A LunaNet Lunar Augmented Navigation Service (LANS) is being developed to enable a position, navigation, and timing service for future Lunar operations [1]. The signal includes two components. An in-phase data channel signal is spread by a 1.023 MCPS ranging code that provides a high-rate data message at 250 bps and is encoded by a strong Low Density Parity Check (LDPC) code. A pilot channel with a 5.115 MCPS spreading code is also provided. The pilot code is configured with a secondary (overlay) code that does not currently provide absolute time or frame Synchronization as is the case for L1C [2] [3]. This work shows the advantage of implementing an overlay structure that provides absolute time for the LunaNet LANS signal structure known as the Augmented Forward Signal (AFS). The LunaNet AFS structure was developed to service two classes of user receivers. The first class is a low-complexity user receiver that only receives the 1.023 MCPS signal and does not use the 5.115 MCPS pilot channel. For this class of user, a data frame Sync word is needed. The second class of receiver is a high-end receiver that can processes both data and pilot channels to take advantage of the higher chip rate pilot channel for enhanced robustness and improved accuracy. In the current draft LunaNet LANS AFS design, these users must employ the frame Sync word in the data channel and obtain absolute time after decoding the AFS navigation message [2]. The signal structure would greatly benefit from the addition of a pilot overlay structure that provides absolute time and robust frame Sync for high-end users as done for L1C [3]. To provide a more robust and interoperable AFS structure, this work summarizes a study and recommends alternatives for a new overlay code on the pilot channel that provides absolute time and a Sync word approach on the data channel. The overlay code and Sync word are designed to allow for flexible and robust data synchronization for both low- complexity and high-end user receivers. The new overlay code structure permits frame synchronization performance that is as good as or better than the L1 C signal, while enabling a determination of absolute time upon frame Sync to aid high-end assisted LANS AFS user receivers at low signal to noise levels. We also present the design of rate-matched 5G new radio (5GNR) LDPC codes that fit within the current 6000-symbol frame size along with a time of interval (TOI) word, frame ID (FID) word, and the remaining LunaNet AFS data message blocks. The paper describes and demonstrates robust frame Synchronization performance of the overlay code and Synch word approaches. The results are described in terms of probability of missed detection and probability of false alarm for a correct frame Synchronization at low Eb/No levels expected for decoding the TOI word and LDPC encoded data. Advantages of the proposed data Synchronization structure will be described along with use cases for low-end and high-end receivers. Practical implementation considerations will also be described.

Philip Dafesh↗

Testing of A Photon-Counting Optical Ground Receiver With Emulated Space-to-Ground Link Effects

The National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) developed and previously characterized a photon-counting optical ground receiver system. The receiver is compliant with the Consultative Committee for Space Data Systems (CCSDS) Optical Communications Coding and Synchronization High Photon Efficiency (HPE) Standard. The standard will be used on the Optical Artemis-2 Orion (O2O) communications demonstration and the Deep Space Optical Communication (DSOC) project aboard the Psyche spacecraft. The receiver system consists of a fiber interconnect, up to sixteen superconducting nanowire single-photon detectors (SNSPDs), and a field programmable gate array (FPGA) based receive modem. Previously, the receiver system architecture was described and test results without emulated link effects were presented. SNSPD device properties, which impact detection jitter and time delay, can limit the receiver dynamic range, especially when operating with varying flux rates (>10 dB) between detectors. Codeword error-rate curves with and without simulated clock drifts attributed to Doppler shift and space transmitter clock differences are presented. Results with ±66 ppm clock differences show minimal performance impact (<0.2 dB). Test results show that the receiver dynamic range (>28 dB) is limited by changing SNSPD detection delays at high photon flux rates.

optical communications↗

Testing of A Photon-Counting Optical Ground Receiver With Emulated Space-to-Ground Link Effects

The National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) developed and previously characterized a photon-counting optical ground receiver system. The receiver is compliant with the Consultative Committee for Space Data Systems (CCSDS) Optical Communications Coding and Synchronization High Photon Efficiency (HPE) Standard. The standard will be used on the Optical Artemis-2 Orion (O2O) communications demonstration and the Deep Space Optical Communication (DSOC) project aboard the Psyche spacecraft. The receiver system consists of a fiber interconnect, up to sixteen superconducting nanowire single-photon detectors (SNSPDs), and a field programmable gate array (FPGA) based receive modem. Previously, the receiver system architecture was described and test results without emulated link effects were presented. SNSPD device properties, which impact detection jitter and time delay, can limit the receiver dynamic range, especially when operating with varying flux rates (>10 dB) between detectors. Codeword error-rate curves with and without simulated clock drifts attributed to Doppler shift and space transmitter clock differences are presented. Results with ±66 ppm clock differences show minimal performance impact (<0.2 dB). Test results show that the receiver dynamic range (>28 dB) is limited by changing SNSPD detection delays at high photon flux rates.

optical communications↗

Towards high data-rate diffusive molecular communications: A review on performance enhancement strategies

Diffusive molecular communications (DiMC) have recently gained attention as a candidate for nano- to micro- and macro-scale communications due to its simplicity and energy efficiency. As signal propagation is solely enabled by Brownian motion mechanics, DiMC faces severe inter-symbol interference (ISI), which limits reliable and high data-rate communications. Herein, recent literature on DiMC performance enhancement strategies is surveyed; key research directions are identified. Signaling design and associated design constraints are presented. Here, studies on fundamental information theoretic limits of DiMC channel are reviewed. Classical and novel transceiver designs are discussed with an emphasis on methods for ISI mitigation and performance-complexity tradeoffs. Key parameter estimation strategies such as synchronization and channel estimation are considered in conjunction with asynchronous and timing error robust receiver methods. Finally, source and channel coding in the context of DiMC is presented.

42 ENGINEERING↗

Simulation analysis of a microcomputer-based, low-cost omega navigation system

A status report is presented on a proposed low-cost Omega Navigation System (ONS) based on a microcomputer (Available commercially). Minimum hardware and maximum software are designed for. Electronic subsystems are discussed in detail, with block diagrams of the receiver and microcomputer interface modules, and a flowchart of the automatic synchronization process. The system is designed as a precision navaid for general aviation in the $1000 price range.

Lilley, R. W.↗

A synchronization technique for optical PPM signals

A technique for maintaining synchronization between optical PPM (pulse-position modulation) pulses and a receiver clock by means of a delay-tracking loop is described and analyzed. The tracking loop is driven by a doubly stochastic Poisson process that contains information about the location of the desired slot boundaries. The slot boundaries are subject to slowly varying random delays that are ultimately tracked by the loop. The concept of fractional rms delay error is introduced to quantify the effects of signal and background induced shot noise on the performance of the delay-tracking loop.

Vilnrotter, V. A.↗

A synchronization technique for optical PPM signals

A technique for maintaining synchronization between optical PPM (pulse-position modulation) pulses and a receiver clock by means of a delay-tracking loop is described and analyzed. The tracking loop is driven by a doubly stochastic Poisson process that contains information about the location of the desired slot boundaries. The slot boundaries are subject to slowly varying random delays that are ultimately tracked by the loop. The concept of fractional rms delay error is introduced to quantify the effects of signal and background induced shot noise on the performance of the delay-tracking loop.

Vilnrotter, V. A.↗

Digital synchronization and communication techniques

Information on digital synchronization and communication techniques is given in viewgraph form. Topics covered include phase shift keying, modems, characteristics of open loop digital synchronizers, an open loop phase and frequency estimator, and a digital receiver structure using an open loop estimator in a decision directed architecture.

Lindsey, William C.↗

Performance results of a digital test signal generator

Performance results of a digital test signal-generator hardware-demonstration unit are reported. Capabilities available include baseband and intermediate frequency (IF) spectrum generation, for which test results are provided. Repeatability in the setting of a given signal-to-noise ratio (SNR) when a baseband or an IF spectrum is being generated ranges from 0.01 dB at high SNR's or high data rates to 0.3 dB at low data rates or low SNR's. Baseband symbol SNR and carrier SNR (Pc/No) accuracies of 0.1 dB were verified with the built-in statistics circuitry. At low SNR's that accuracy remains to be fully verified. These results were confirmed with measurements from a demodulator synchronizer assembly for the baseband spectrum generation, and with a digital receiver (Pioneer 10 receiver) for the IF spectrum generation.

Gutierrez-Luaces, B. O.↗

Experiment K-7-23: Effect of Spaceflight on Level and Function of Immune Cells: Immunology Studies - Part 1

Two different experiments were carried out in this segment of the immunology protocol for samples received from rats flown on Cosmos 2044. Control groups included vivarium, synchronous and antiorthostatically suspended rats. In the first experiment, rat bone marrow cells were examined in Moscow for their response to recombinant murine colony stimulating factor-granulocyte / monocyte (CSF-GM). In the second experiment, rat spleen and bone marrow cells were stained in Moscow with a variety of antibodies directed against cell surface antigenic markers. These cells were preserved and shipped to the United States for analysis on a flow cytometer. The results of the studies indicated that bone marrow cells from flown and suspended rats showed a decreased response to CSF-GM as compared to bone marrow cells from control rats. Spleen cells from flown rats showed increased percentages of suppressor-cytotoxic-T and helper-T cells amongst the entire cell population. Bone marrow cells showed an increase in the percentage of helper-T cells in the myelogenous population and increased percentages of anti-asialo GM-1 bearing, interleukin-2 receptor bearing, pan-T and helper-T cells in the lymphocytic population. Cell populations from rats suspended antiorthostatically did not follow the same pattern of distribution of leukocytes as cell populations for flown rats. These results are similar, but not identical to, earlier results from Cosmos 1887, and confirm that space flight can have profound effects on immune system components and activities.

Sonnenfeld, G.↗

Wireless Integrated Microelectronic Vacuum Sensor System

NASA Stennis Space Center's (SSC's) large rocket engine test facility requires the use of liquid propellants, including the use of cryogenic fluids like liquid hydrogen as fuel, and liquid oxygen as an oxidizer (gases which have been liquefied at very low temperatures). These fluids require special handling, storage, and transfer technology. The biggest problem associated with transferring cryogenic liquids is product loss due to heat transfer. Vacuum jacketed piping is specifically designed to maintain high thermal efficiency so that cryogenic liquids can be transferred with minimal heat transfer. A vacuum jacketed pipe is essentially two pipes in one. There is an inner carrier pipe, in which the cryogenic liquid is actually transferred, and an outer jacket pipe that supports and seals the vacuum insulation, forming the "vacuum jacket." The integrity of the vacuum jacketed transmission lines that transfer the cryogenic fluid from delivery barges to the test stand must be maintained prior to and during engine testing. To monitor the vacuum in these vacuum jacketed transmission lines, vacuum gauge readings are used. At SSC, vacuum gauge measurements are done on a manual rotation basis with two technicians, each using a handheld instrument. Manual collection of vacuum data is labor intensive and uses valuable personnel time. Additionally, there are times when personnel cannot collect the data in a timely fashion (i.e., when a leak is detected, measurements must be taken more often). Additionally, distribution of this data to all interested parties can be cumbersome. To simplify the vacuum-gauge data collection process, automate the data collection, and decrease the labor costs associated with acquiring these measurements, an automated system that monitors the existing gauges was developed by Invocon, Inc. For this project, Invocon developed a Wireless Integrated Microelectronic Vacuum Sensor System (WIMVSS) that provides the ability to gather vacuum-gauge measurements automatically and wirelessly, in near-real time - using a low-maintenance, lowpower sensor mesh network. The WIMVSS operates by using a self-configuring mesh network of wireless sensor units. Mesh networking is a type of networking where each sensor or node can capture and disseminate its own data, but also serve as a relay to receive and transmit data from other sensors. Each sensor node can synchronize with adjacent sensors, and propagate data from one sensor to the next, until the destination is reached. In this case, the destination is a Network Interface Unit (NIU). The WIMVSS sensors are mounted on the existing vacuum gauges. Information gathered by the sensors is sent to the NIU. Because of the mesh networking, if a sensor cannot directly send the data to the NIU, it can be propagated through the network of sensors. The NIU requires antenna access to the sensor units, AC power, and an Ethernet connection. The NIU bridges the sensor network to a WIMVSS server via an Ethernet connection. The server is configured with a database, a Web server, and proprietary interface software that makes it possible for the vacuum measurements from vacuum jacketed fluid lines to be saved, retrieved, and then displayed from any Web-enabled PC that has access to the Internet. Authorized users can then simply access the data from any PC with Internet connection. Commands can also be sent directly from the Web interface for control and maintenance of the sensor network. The technology enabled by the WIMVSS decreases labor required for gathering vacuum measurements, increases access to vacuum data by making it available on any computer with access to the Internet, increases the frequency with which data points can be acquired for evaluating the system, and decreases the recurring cost of the sensors by using off-the-shelf components and integrating these with heritage vacuum gauges.

Krug, Eric↗

Neoadjuvant Chemotherapy does not Increase Complications in Oncoplastic Breast-Conserving Surgery

Background: Oncoplastic breast-conserving surgery (OBCS) broadens the indications for breast conservation. Neoadjuvant systemic chemotherapy (NAC) is used increasingly in the treatment of patients with early-stage and locally advanced breast cancer. This study aimed to evaluate the outcomes for patients who received NAC followed by OBCS. Methods: A retrospective chart review was performed for all patients who underwent OBCS involving the mastopexy/breast-reduction technique, including synchronous mastopexy/breast reduction for symmetry, at the University of Texas MD Anderson Cancer Center between January 2010 and January 2016. Patients who had received NAC were compared with those who had undergone surgery first. Demographic, treatment, and outcomes data were collected. Results: The study included 429 patients, corresponding to 713 breasts. Of these patients, 122, corresponding to 199 breasts, received NAC. The patients who received NAC were younger (p < 0.001) and had a more advanced cancer stage (p < 0.001). The overall complication rate per patient was 25.9%, with major complications occurring in 9.1% of the patients. After adjustment for risk factors, NAC was not shown to be associated with an increased risk of complications or delayed adjuvant radiation therapy (p = 0.37), irrespective of the chemotherapy regimen used or whether the interval between NAC and surgery was 4 weeks or longer. Conclusions: In a high-volume center, OBCS can be performed safely for carefully selected patients after NAC without an increased risk of complications or delayed adjuvant radiation therapy. An interval of at least 4 weeks between completion of NAC and surgery can be regarded as safe irrespective of the chemotherapy regimen used.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multi-user satellite communications system using an innovative compressive receiver

There is a need for an onboard simultaneous multi-channel demodulation system for a satellite communications system. Studies indicate that Convolve Multiply Convolve (CMC) filtering with surface acoustic wave (SAW) dispersive delay lines will eliminate the necessity of onboard satellite channelized filters of complex fourier transform processors. The reason for choosing the CMC technique is its ability to perform Fourier transformations in a shorter time with less space and power consumption than digital Fourier transform processors. Each ground terminal in this multi-users communications system is remotely located and operates independently; hence, a method of synchronizing the transmission of these users is presented which utilizes the existing Global Positioning System (GPS) system. Each ground user is equipped with a low cost ground terminal that has a synchronization subsystem attached to it. The system design of an onboard Multi-channel Receiver and Demodulator utilizes Quadrature Phase Shift Keying (QPSK) as the modulation technique. This technique provides the best figure of merit, i.e., the lowest transmitter power requirement per communication channel.

Staples, Edward J.↗

The SIRIO-1 timing experiment

A time synchronization experiment was performed between two ground stations located in the northern and in the central part of Italy. The rf communication channels used are in the SHF region, with the uplink carrier at 18 GHz and the downlink at 12 GHz. One way and two way techniques were evaluated. Two modes of operation were tested in the two way technique: sequential, time multiplexed, signal transmission on the same communication channel; and simultaneous transmission using separate communication channel. In the sequential mode of operation, range and doppler measurements provided by the timing signals were used to account for the satellite motion. A low cost, versatile, time transfer unit (TTU) was designed, to generate the timing signals and the functions (RF carrier and receiver switching, time tagging of the data, etc.) required to perform automatic time synchronization and data acquisition with a minimum of external components.

Detoma, E.↗

Solid state transmitters for spaceborne radars

The SEASAT-A synthetic aperture radar, the first spaceborne SAR, utilized an all solid state RF signal synthesizer and L-band transmitter to drive a corporately fed flat plate array. The RF signal synthesizer generated a linear FM ""CHIRP'' waveform and provided stable CW reference signals used to upconvert the received signal to a unified S-band downlink channel, and to synchronize satellite control logic. The transmitter generated 1200 watts peak RF power (66 watts average) at a center frequency of 1.275 GHz from 354 watts of DC prime power. Linear FM CHIRP swept symmetrically around the center frequency with a bandwidth of 19.05 MHz and a pulse duration of 33.8 sec. Pulse repetition rate was variable from 1647 to 1944 pps. These transmitter signal parameters combined with the flat plate 34 x 7.5 ft aperture at an orbital altitude of 498 miles and a look angle 20 deg off nadir gave the SAR an 85 foot resolution over a 15.5 mile wide swath.

Turlington, T. R.↗

CubeSat Laser Infrared CrosslinK

The CubeSat Laser Infrared CrosslinK (CLICK) mission will demonstrate technology to advance the state of the art in intersatellite communications for small spacecraft. The primary objective of the mission is an on-orbit demonstration of full-duplex (send and receive) laser, also called optical communication, crosslink between two six-unit(6U) small satellites that range in distance between 15 and 360 miles (25 - 580 kilometers) apart at data rates greater than 20 megabits per second (Mbps). The mission will also demonstrate precision satellite-to-satellite clock synchronization and ranging at the 10 cm level. Miniaturized optical transceivers capable of both transmitting and receiving laser communications will form a communication crosslink between the two satellites with their alignment supported with a new fine pointing capability. The miniature optical transceivers are an improvement over radio frequency (RF) technology due to the power efficiency of lasercom high data rate transmission, which lessens the impact on the small platform's already severe constraints on size, weight and power.

Mayer, David J.↗

Optimum frame synchronization.

This paper considers the optimum method for locating a sync word periodically imbedded in binary data and received over the additive white Gaussian noise channel. It is shown that the optimum rule is to select the location that maximizes the sum of the correlation and a correction term. Simulations are reported that show approximately a 3-dB improvement at interesting signal-to-noise ratios compared to a pure correlation rule. Extensions are given to the phase-shift keyed sync case where the detector output has a binary ambiguity and to the case of Gaussian data.

Massey, J. L.↗