Microwave diagnostics and passive sensors for pipeline, well-bore, and boiler-tube monitoring

Materials, methods of making, and methods of using an integrated wireless detector for real time interrogating metallic tubular structures comprising: an RF patch antenna; a passive surface acoustic wave (SAW) sensor; and data analytic methodologies. An embodiment relates to interrogating a metallic structure having a uniform cross section using an antenna which launches electromagnetic radiation. A sensor may be located within the structure is configured to re-emit electromagnetic radiation modified depending on parameters for which the sensor has been functionalized. An antenna may receive radiation as modified by the sensor, or may receive the transmitted or backscattered radiation directly, without use of a sensor. The antenna then communicates wirelessly with an interrogator providing data which may be used to understand the operational status of the structure in real-time.

Ohodnicki, Paul R.↗

Effect of Zero Valent Iron Pre-treatments on Reductive Removal of Aqueous Tc-99 - 19379

Zero-valent iron (ZVI) is being investigated as a potential material for technetium-99 (Tc-99) reductive separation from the secondary liquid waste, i.e. off-gas condensate that will be generated during vitrification of the law activity waste (LAW) at the Hanford site. In this work, we performed a comparative analysis of Tc(VII) removal kinetics via its reduction with the commercially available ZVI materials varying in particle size (granules, filings, and 200 mesh). In addition to particle size differences, reduction removal potential was also evaluated as a function of as-received ZVI material versus a surface treatment. ZVI treatment experiments with 0.4 M HCl and 1 M NaCl were conducted to study the effect of iron oxide/oxyhydroxide formation on its reductive efficiency for aqueous Tc(VII) removal. Scanning electron microscopy (SEM) with energy dispersive spectroscopy (EDS) analyses were conducted for all ZVI materials in the presence and absence of treatments to evaluate morphological differences (SEM) and chemical composition (EDS) of the materials. Reductive removal of Tc(VII) was also analyzed using a first-order kinetic model. The results of the study indicated that rate constants did not change with increased oxide/oxyhydroxide content in large ZVI materials (granules and filings), but decreased significantly for the relatively small ZVI (200 mesh), treated with 0.4 M HCl and 1 M NaCl. This study demonstrates that the commercial ZVI material 200 mesh, used as received, is a promising candidate for the removal of Tc from liquid secondary waste generated during Hanford LAW vitrification. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Integrated Advanced Microwave Sounding Unit-A (AMSU-A). Performance Verification Report: EOS AMSU-A1 and AMSU-A2 Receiver Assemblies

The AMSU-A receiver subsystem comprises two separated receiver assemblies; AMSU-A1 and AMSU-A2 (P/N 1356441-1). The AMSU-A1 receiver contains 13 channels and the AMSU-A2 receiver 2 channels. The AMSU-A1 receiver assembly is further divided into two parts; AMSU-A1-1 (P/N 1356429-1) and AMSU-A1-2 (P/N 1356409-1), which contain 9 and 4 channels, respectively. The receiver assemblies are highlighted and illustrate the functional block diagrams of the AMSU-A1 and AMSU-A2 systems. The AMSU-A receiver subsystem stands in between the antenna and signal processing subsystems of the AMSU-A instrument and comprises the RF and IF components from isolators to attenuators. It receives the RF signals from the antenna subsystem, down-converts the RF signals to IF signals, amplifies and defines the IF signals to proper power level and frequency bandwidth as specified for each channel, and inputs the IF signals to the signal processing subsystem. This test report presents the test data of the EOS AMSU-A Flight Model No. 1 (FM-1) receiver subsystem. The tests are performed per the Acceptance Test Procedure for the AMSU-A Receiver Subsystem, AE-26002/6A. The functional performance tests are conducted either at the component or subsystem level. While the component-level tests are performed over the entire operating temperature range predicted by thermal analysis, the subsystem-level tests are conducted at ambient temperature only.

Ma, Y.↗

Autonomous Integrated Receive System (AIRS) requirements definition. Volume 2: Design and development

Functional requirements and specifications are defined for an autonomous integrated receive system (AIRS) to be used as an improvement in the current tracking and data relay satellite system (TDRSS), and as a receiving system in the future tracking and data acquisition system (TDAS). The AIRS provides improved acquisition, tracking, bit error rate (BER), RFI mitigation techniques, and data operations performance compared to the current TDRSS ground segment receive system. A computer model of the AIRS is used to provide simulation results predicting the performance of AIRS. Cost and technology assessments are included.

Chie, C. M.↗

Modified timing module for Loran-C receiver

Full hardware documentation is provided for the circuit card implementing the Loran-C timing loop, and the receiver event-mark and re-track functions. This documentation is to be combined with overall receiver drawings to form the as-built record for this device. Computer software to support this module is integrated with the remainder of the receiver software, in the LORPROM program.

Lilley, R. W.↗

Designing a Block Copolymer Membrane for Selective Transport of Lactic Acid from Aqueous Mixtures

We report the design and synthesis of a triblock copolymer-based membrane for enabling selective transport of lactic acid from aqueous solutions. This is relevant to the production of polylactic acid, one of the few biodegradable and biobased polymers with sufficient mechanical strength for practical applications. The end blocks are positively charged with negatively charged lactate counterions. The middle block is polybutadiene (PBD). Due to microphase separation, the charged blocks form channels for transporting lactic acid. The mechanical integrity of the membrane is controlled by cross-linking the PBD block. Transport of lactic acid and water across the membrane was studied by placing the membrane between two chambers, a feed chamber containing aqueous lactic acid solutions, and a receiving chamber containing pure water. The lactic acid concentration in the receiving chamber was monitored as a function of time using conductivity, HPLC, and NMR. The corresponding flux of water from the receiving chamber to the feed chamber was measured using an NMR-based approach. The lactic acid and water permeabilities through our membrane were (1.12 ± 0.05) × 10–8 and (8.58 ± 0.75) × 10–9 cm2 s–1. To our knowledge, there are no reports of lactic acid permeabilities through any membrane in the literature. The separation factor of our membrane, αLA/water, 1.305 ± 0.123, is comparable to that of membranes used for selective transport of ethanol, despite the fact that lactic acid is a much larger molecule than ethanol. Selective transport of lactic acid in our membrane is governed mainly by differences in solubility; lactic acid is 18 times more soluble in the membrane than water.

Jana, Rounak↗

Integration of Functional MRI and White Matter Tractography in Stereotactic Radiosurgery Clinical Practice

Purpose: To study the efficacy of the integration of functional magnetic resonance imaging (fMRI) and diffusion tensor imaging tractography data into stereotactic radiosurgery clinical practice. Methods and Materials: fMRI and tractography data sets were acquired and fused with corresponding anatomical MR and computed tomography images of patients with arteriovenous malformation (AVM), astrocytoma, brain metastasis, or hemangioma and referred for stereotactic radiosurgery. The acquired data sets were imported into a CyberKnife stereotactic radiosurgery system and used to delineate the target, organs at risk, and nearby functional structures and fiber tracts. Treatment plans with and without the incorporation of the functional structures and the fiber tracts into the optimization process were developed and compared. Results: The nearby functional structures and fiber tracts could receive doses of >50% of the maximum dose if they were excluded from the planning process. In the AVM case, the doses received by the Broadmann-17 structure and the optic tract were reduced to 700 cGy from 1,400 cGy and to 1,200 cGy from 2,000 cGy, respectively, upon inclusion into the optimization process. In the metastasis case, the motor cortex received 850 cGy instead of 1,400 cGy; and in the hemangioma case, the pyramidal tracts received 780 cGy instead of 990 cGy. In the astrocytoma case, the dose to the motor cortex bordering the lesion was reduced to 1,900 cGy from 2,100 cGy, and therefore, the biologically equivalent dose in three fractions was delivered instead. Conclusions: Functional structures and fiber tracts could receive high doses if they were not considered during treatment planning. With the aid of fMRI and tractography images, they can be delineated and spared.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Determination of mean surface position and sea state from the radar return of a short-pulse satellite altimeter

Using the specular point theory of scatter from a very rough surface, the average backscatter cross section per unit area per radar cell width is derived for a cell located at a given height above the mean sea surface. This result is then applied to predict the average radar cross section observed by a short-pulse altimeter as a function of time for two modes of operation: pulse-limited and beam-limited configurations. For a pulse-limited satellite altimeter, a family of curves is calculated showing the distortion of the leading edge of the receiver output signal as a function of sea state (i.e., wind speed). A signal processing scheme is discussed that permits an accurate determination of the mean surface position--even in high seas--and, as a by-product, the estimation of the significant seawave height (or wind speed above the surface). Comparison of these analytical results with experimental data for both pulse-limited and beam-limited operation lends credence to the model. Such a model should aid in the design of short-pulse altimeters for accurate determination of the geoid over the oceans, as well as for the use of such altimeters for orbital sea-state monitoring.

Barrick, D. E.↗

Mountain-Top-to-Mountain-Top Optical Link Demonstration

A mountain-top-to-mountain-top optical link was demonstrated between JPL's Table Mountain Facility (TMF), Wrightwood, California, and Strawberry Peak (SP), Lake Arrowhead, California, during the months of June, August, and September of 2000. The bidirectional laser link was nearly horizontal at an altitude of 2 km and spanned a range of 46.8 km. The 780-nm beacon laser transmitted from TMF comprised eight co-propagating mutually incoherent laser beams. The normalized variance or scintillation index (SI) of the individual beacon lasers measured by recording the signal received through 8.50-cm-diameter spotting telescopes on three different nights (June 28-30, 2000) was 1.05 +/- 0.2, 1.76 +/- 0.6, and 0.96 +/- 0.24, respectively. These measurements agreed with values predicted by a heuristic model. The SI of the signal received at SP was found to decrease progressively with an increasing number of beams, and a factor of 3 to 3.5 reduction was achieved for all eight beams. The beam divergence determined by mapping out the point spread function of a few of the individual laser footprints received at SP was 85 to 150 microrad, compared to a design goal of 120 microrad. The 852-nm communications laser beam received at TMF through a 60-cm-diameter telescope on the nights of August 4 and September 14 and 15, 2000, yielded SI values of 0.23 +/- 0.04, 0.32 +/- 0.01, and 0.49 +/- 0.18, respectively, where the reduction was attributed to aperture averaging. The probability distribution functions of the received signal at either end, mitigated by multi-beam averaging in one direction and by aperture averaging in the other direction, displayed lognormal behavior. Consequently, the measured fade statistics showed good agreement with a lognormal model.

Biswas, A.↗

4DCT-based measurement of changes in pulmonary function following a course of radiation therapy

Purpose: Radiation therapy (RT) for lung cancer is commonly limited to subtherapeutic doses due to unintended toxicity to normal lung tissue. Reducing the frequency of occurrence and magnitude of normal lung function loss may benefit from treatment plans that incorporate the regional lung and radiation dose information. In this article, the authors propose a method that quantitatively measures the regional changes in lung tissue function following a course of radiation therapy by using 4DCT and image registration techniques. Methods: 4DCT data sets before and after RT from two subjects are used in this study. Nonlinear 3D image registration is applied to register an image acquired near end inspiration to an image acquired near end expiration to estimate the pulmonary function. The Jacobian of the image registration transformation, indicating local lung expansion or contraction, serves as an index of regional pulmonary function. Approximately 120 annotated vascular bifurcation points are used as landmarks to evaluate registration accuracy. The authors compare regional pulmonary function before and after RT to the planned radiation dose at different locations of the lung. Results: In all registration pairs, the average landmark distances after registration are on the order of 1 mm. The pulmonary function change as indicated by the Jacobian change ranges from -0.15 to 0.1 in the contralateral lung and -0.22 to 0.23 in the ipsilateral lung for subject A, and ranges from -0.4 to 0.39 in the contralateral lung and -0.25 to 0.5 in the ipsilateral lung for subject B. Both of the subjects show larger range of the increase in the pulmonary function in the ipsilateral lung than the contralateral lung. For lung tissue regions receiving a radiation dose larger than 24 Gy, a decrease in pulmonary function was observed. For regions receiving a radiation dose smaller than 24 Gy, either an increase or a decrease in pulmonary function was observed. The relationship between the pulmonary function change and the radiation dose varies at different locations. Conclusions: With the use of 4DCT and image registration techniques, the pulmonary function prior to and following a course of radiation therapy can be measured. In the preliminary application of this approach for two subjects, changes in pulmonary function were observed with a weak correlation between the dose and pulmonary function change. In certain sections of the lung, detected locally compromised pulmonary function may have resulted from radiation injury.

61 RADIATION PROTECTION AND DOSIMETRY↗

SOFTC: A Software Correlator for VLBI

SOFTC is an advanced software implementation of a signal correlator for very-long-baseline interferometry (VLBI) for measuring positions of natural celestial objects and distant spacecraft. Because of increases in processing speeds of general-purpose computers, software VLBI correlators have become viable alternatives to hardware ones. The input to SOFTC consists of digitized samples of raw VLBI-antenna received- signal voltages. Optionally, SOFTC also tracks calibration tones superimposed on the received signals. The outputs of SOFTC are (1) phases and amplitudes as functions of time and frequency for cross-correlated received signals and (2) phases and amplitudes as functions of time, station, and tone number for the calibration tones. SOFTC was created to be as accurate as possible, capable of processing essentially any VLBI data, pass strong debugging tests, have a simple user interface, and have no platform dependencies. SOFTC is written modularly in the C programming language. The great advantage of implementing a correlator in software, in contradistinction to hardware, is that it becomes relatively easy and much less expensive and time-consuming to adapt, modify, improve, and update the correlator.

Lowe, Stephen↗

Prospective Study of Functional Bone Marrow-Sparing Intensity Modulated Radiation Therapy With Concurrent Chemotherapy for Pelvic Malignancies

Purpose: To test the hypothesis that intensity modulated radiation therapy (IMRT) can reduce radiation dose to functional bone marrow (BM) in patients with pelvic malignancies (phase IA) and estimate the clinical feasibility and acute toxicity associated with this technique (phase IB). Methods and Materials: We enrolled 31 subjects (19 with gynecologic cancer and 12 with anal cancer) in an institutional review board-approved prospective trial (6 in the pilot study, 10 in phase IA, and 15 in phase IB). The mean age was 52 years; 8 of 31 patients (26%) were men. Twenty-one subjects completed {sup 18}F-fluorodeoxyglucose (FDG)-positron emission tomography (PET)/computed tomography (CT) simulation and magnetic resonance imaging by use of quantitative IDEAL (IDEAL IQ; GE Healthcare, Waukesha, WI). The PET/CT and IDEAL IQ were registered, and BM subvolumes were segmented above the mean standardized uptake value and below the mean fat fraction within the pelvis and lumbar spine; their intersection was designated as functional BM for IMRT planning. Functional BM-sparing vs total BM-sparing IMRT plans were compared in 12 subjects; 10 were treated with functional BM-sparing pelvic IMRT per protocol. Results: In gynecologic cancer patients, the mean functional BM V{sub 10} (volume receiving {>=}10 Gy) and V{sub 20} (volume receiving {>=}20 Gy) were 85% vs 94% (P<.0001) and 70% vs 82% (P<.0001), respectively, for functional BM-sparing IMRT vs total BM-sparing IMRT. In anal cancer patients, the corresponding values were 75% vs 77% (P=.06) and 62% vs 67% (P=.002), respectively. Of 10 subjects treated with functional BM-sparing pelvic IMRT, 3 (30%) had acute grade 3 hematologic toxicity or greater. Conclusions: IMRT can reduce dose to BM subregions identified by {sup 18}F-fluorodeoxyglucose-PET/CT and IDEAL IQ. The efficacy of BM-sparing IMRT is being tested in a phase II trial.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A simulation of GPS and differential GPS sensors

The Global Positioning System (GPS) is a revolutionary advance in navigation. Users can determine latitude, longitude, and altitude by receiving range information from at least four satellites. The statistical accuracy of the user's position is directly proportional to the statistical accuracy of the range measurement. Range errors are caused by clock errors, ephemeris errors, atmospheric delays, multipath errors, and receiver noise. Selective Availability, which the military uses to intentionally degrade accuracy for non-authorized users, is a major error source. The proportionality constant relating position errors to range errors is the Dilution of Precision (DOP) which is a function of the satellite geometry. Receivers separated by relatively short distances have the same satellite and atmospheric errors. Differential GPS (DGPS) removes these errors by transmitting pseudorange corrections from a fixed receiver to a mobile receiver. The corrected pseudorange at the moving receiver is now corrupted only by errors from the receiver clock, multipath, and measurement noise. This paper describes a software package that models position errors for various GPS and DGPS systems. The error model is used in the Real-Time Simulator and Cockpit Technology workstation simulations at NASA-LaRC. The GPS/DGPS sensor can simulate enroute navigation, instrument approaches, or on-airport navigation.

Rankin, James M.↗

Auto covariance computer

A laser velocimeter covariance processor which calculates the auto covariance and cross covariance functions for a turbulent flow field based on Poisson sampled measurements in time from a laser velocimeter is described. The device will process a block of data that is up to 4096 data points in length and return a 512 point covariance function with 48-bit resolution along with a 512 point histogram of the interarrival times which is used to normalize the covariance function. The device is designed to interface and be controlled by a minicomputer from which the data is received and the results returned. A typical 4096 point computation takes approximately 1.5 seconds to receive the data, compute the covariance function, and return the results to the computer.

Hepner, T. E.↗

Radar optimization for sea surface and geodetic measurements

The efficient estimation of geoid and sea state parameters is discussed, and the optimum processing structures, including maximum likelihood estimators, and their accuracy limits are given for a model. The model accounts for random surface reflectivity, sea height, and additive noise, and allows for arbitrary radar system parameters, based on the assumption the received signal is a sample function of a normal random process. The integral equation associated with the Gaussian signal in Gaussian noise inference problem was solved. It is shown that the optimum processing is generally a mixture of coherent and incoherent integrations which may be viewed as a weighted summation of received power of the match-filtered received data. When estimates are correlated, the strongest correlation appears between geoid and asymmetry estimates, and between wave height standard deviation and reflectivity estimates.

Harger, R. O.↗

SansEC: A New Dimension to Sensing Electrical Sensors with No Electrical Connections

This DVD contains an introduction to SansEC, a new electrical sensor technology without electrical connections. This new class of sensors represents a stand-alone 2-dimensional geometric pattern of electrically open circuits without electrical connections. The sensor is powered with an external, harmonic magnetic field and as the property being sensed changes, responds to frequency, amplitude or bandwidth changes. This response is interrogated using an external antenna, a single electrical component having no electrical connections. The sensor can be encased in any nonconductive material to provide protection from its environment. If the container is nonconductive, the sensor can be placed external to the container without contacting it, making installation very simple. An encased sensor can also be placed inside a container for measuring the level of any fluid or material, including acids. Any readout device can be used with the sensor, including standard or digital gauges. SansEC sensors can be used to measure real-time fluid slosh to determine if a fuel tank's internal structural isogrid can be used to replace some of the baffles surface, thus reducing the overall baffle weight and giving a better understanding of the effect that isogrids have on fluid motion. Any SansEC sensor can also be used for damage or tamper detection. When damaged, torn or tampered with, the measured response shift in frequency is commensurate to the detected damage, with the response frequency increasing with rising damage. The unique sensor design allows it to function even if damaged, because unlike other circuits, there is no single point on the sensor that, if damaged, renders it non-functional. The broad metallic coverage of the array allows the array to be one of many thermal insulation layers. Two such arrays were tested to understand the effects of high velocity damage. Each test article was targeted with metal projectiles emulating micrometeorite or orbital debris impact. Even with the damage that the sensors received every sensor was still functional with the new response baseline, and remained capable of detecting even more damage.

Source record↗

Halo Zel’dovich model and perturbation theory: Dark matter power spectrum and correlation function

Perturbation theory for dark matter clustering has received a lot of attention in recent years, but its convergence properties remain poorly justified and there is no successful model that works both for correlation functions and for power spectra. In this paper we present the halo Zel’dovich approach combined with perturbation theory, in which we use standard perturbation theory at one-loop order (SPT) at very low k, and connect it to a version of the halo model, for which we adopt the Zel’dovich approximation plus a Padé expansion of a compensated one-halo term. This low-k matching allows us to determine the one-halo term amplitude and redshift evolution, both of which are in an excellent agreement with simulations, and approximately agree with the expected value from the halo model. Our Padé expansion approach of the one-halo term added to the Zel’dovich approximation identifies a typical halo scale averaged over the halo mass function, the halo radius scale of order of 1 Mpc/h, and a much larger halo mass compensation scale, which can be determined from SPT. The model gives better than one-percent-accurate predictions for the correlation function above 5 Mpc/h at all redshifts, without any free parameters. With three fitted Padé expansion coefficients the agreement in the power spectrum is good to a percent up to k ~ 1h/Mpc, which can be improved to arbitrary k by adding higher-order terms in the Padé expansion.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗