Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radiographs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Penetrating power in radiography of high-Z materials as a function of bremsstrahlung spectrum endpoint energy

A modified radiographer’s equation is derived and fitted to simulation data so as to describe the increase in radiographic signal that comes with increasing bremsstrahlung spectrum endpoint energy. The dose contained in the incident spectrum follows an E28 power law, as often cited. However, the direct flux penetrating through a heavy, high-Z material, obeys a weaker scaling due to hardening of the radiation. The resultant expression depends on the thickness of the scene being radiographed, the composition of high-Z materials in the scene, and any filtering by other low-Z materials, such as Al or Be. The expression exhibits two asymptotic limits: a ‘thick’ limit at which radiation is extremely hardened and only a weak benefit to increasing endpoint energy is observed (also the most attenuating limit and therefore of dubious physical significance), and a ‘thin’ limit at which a minimum of high-Z material is present and the penetrating dose exhibits the 2.8 power scaling inherent in the incident spectrum. Behavior for intermediate thicknesses of W and Al are obtained by modeling incident and attenuated dose using the DOSECALC code and the Bayes’ Inference Engine (BIE). These data guide the optimization of MeV radiography over a wide range of energies where pair production plays a significant role in photon scattering.

36 MATERIALS SCIENCE↗

Overview of the LANL Multi-Probe Radiography Project [Slides]

Future radiographic facilities for the U.S. defense program will be required to provide more information as simulation codes improve in both physics’ fidelity and resolution. A possible approach is to use more types of probe beams in addition to, or instead of X-rays, generated by 20-MeV electron accelerators from a small number of directions. High power short-pulse laser systems can generate beams of protons, neutrons and electrons, as well as X-rays. The cost of these systems is falling rapidly. So, it can be imagined that deploying multiple short-pulse lasers along with other, more traditional probes, will become feasible. In this project, we are following three paths to determine if such an approach will succeed for cm-scale objects. The first is an experimental one to determine if the presence of multiple short-pulse probes cause interference with each other, especially while radiographing dynamic objects. The second leg of this project is to determine if having multiple types of probes really does give more information on composition. Finally, an overall assessment of the viability of this approach will be made. Examples from recent experiments at the Omega EP laser will be presented. The initial approach to evaluating radiographs with multiple probes using the Bayesian Inference Engine (BIE) also will be given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correct Initial Conditions for Simulations of Beam Physics in Linear Induction Accelerators

Flash radiography of hydrodynamic experiments driven by high explosives is a well-known diagnostic technique in use at many laboratories. At Los Alamos, the Dual Axis Radiographic Hydrodynamic Test (DARHT) facility two linear induction electron accelerators (LIAs) make the bremsstrahlung radiographic source spots for point projection radiographs from orthogonal views. A new LIA, called Scorpius, is presently under development to advance this technology. To better understand electron-beam physics in these LIAs, numerical simulations are frequently performed with the objective of improving the radiography. At Los Alamos we frequently use the TRAK ray-trace and LSP particle-in-cell (PIC) codes to simulate the injector, and the XTR and LAMDA envelope/centroid codes along with LSP to simulate transport of the accelerated beam through the LIAs. The LIA simulations need the injected beam parameters as initial conditions for calculating beam transport and stability. The determination of these initial conditions is the topic of this note.

43 PARTICLE ACCELERATORS↗

Muon Radiography with the NOvA Near Detector

Information on the geological and man-made structures, directly contributing to the overburden of the NOvA Near Detector, located 100 m underground at Fermilab, are extracted from the cosmic muon data accumulated in the period April 2015 - October 2016. Results of this radiographic analysis of cosmic data are obtained by exploiting the acceptance symmetries of the NOvA detector. Radiographic maps of the overburden variations are acquired without subtracting the surface muon flux (free sky data) and without MC simulation of the cosmic muons attenuation in the homogeneous and flat overburden. By directly subtracting the angular muon track data measured by the NOvA Near Detector, arriving from directions having the same attenuation length (in the flat-surface approximation) and belonging to the acceptance regions with the same reconstruction efficiency, one can efficiently obtain two-dimensional differential radiographic maps.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Interpretation of aluminum-alloy weld radiography

Report proposes radiographic terminology standardization which allows scientific interpretation of radiographic films to replace dependence on individual judgement and experience. Report includes over 50 photographic pages where radiographs of aluminum welds with defects are compared with prepared weld sections photomacrographs.

Duren, P. C.↗

Evaluation of ultrasonics and optimized radiography for 2219-T87 aluminum weldments

Ultrasonic studies are described which are specifically directed toward the quantitative measurement of randomly located defects previously found in aluminum welds with radiography or with dye penetrants. Experimental radiographic studies were also made to optimize techniques for welds of the thickness range to be used in fabricating the External Tank of the Space Shuttle. Conventional and innovative ultrasonic techniques were applied to the flaw size measurement problem. Advantages and disadvantages of each method are discussed. Flaw size data obtained ultrasonically were compared to radiographic data and to real flaw sizes determined by destructive measurements. Considerable success was achieved with pulse echo techniques and with 'pitch and catch' techniques. The radiographic work described demonstrates that careful selection of film exposure parameters for a particular application must be made to obtain optimized flaw detectability. Thus, film exposure techniques can be improved even though radiography is an old weld inspection method.

Clotfelter, W. N.↗

Residual strength of five boron/aluminum laminates with crack-like notches after fatigue loading

Boron/aluminum specimens were made with crack-like slits in the center and with various proportions of 0 and + or - 45 deg plies. They were fatigue loaded and then fractured to determine their residual strengths. The fatigue loads were generally in the range of 60 to 80 percent of the static tensile strength of the specimen as determined from a previous study, and the stress ratio was .05. For virtually all of the specimens the fatigue loading was continued for 100,000 cycles. The specimens were radiographed after the fatigue loading to determine the nature of the fatigue damage. A few specimens were sectioned and examined in a scanning electron microscope after being radiographed in order to verify the interpretation of the radiographs and also to get a better insight into the nature of the fatigue damage. The results indicate that the fatiguing does not significantly affect the strength of the specimens tested. The results of the radiography and of the scanning electron microscopy indicate that the 45 deg plies suffer extensive damage in the form of split and broken fibers and matrix cracking in the vicinity of the ends of the split. By contrast, the only significant damage to the 0 deg plies was a single 0 deg matric crack growing from the ends of the slit and between the 0 deg fibers.

Simonds, R. A.↗

Residual strength of five boron/aluminum laminates with crack-like notches after fatigue loading

Boron/aluminum specimens were made with crack-like slits in the center and with various proportions of 0 and + or - 45 deg plies. They were fatigue loaded and then fractured to determine their residual strengths. The fatigue loads were generally in the range of 60 to 80 percent of the static tensile strength of the specimen as determined from a previous study, and the stress ratio was .05. For virtually all of the specimens the fatigue loading was continued for 100,000 cycles. The specimens were radiographed after the fatigue loading to determine the nature of the fatigue damage. A few specimens were sectioned and examined in a scanning electron microscope after being radiographed in order to verify the interpretation of the radiographs and also to get a better insight into the nature of the fatigue damage. The results indicate that the fatiguing does not significantly affect the strength of the specimens tested. The results of the radiography and of the scanning electron microscopy indicate that the 45 deg plies suffer extensive damage in the form of split and broken fibers and matrix cracking in the vicinity of the ends of the split. By contrast, the only significant damage to the 0 deg plies was a single 0 deg matric crack growing from the ends of the slit and between the 0 deg fibers.

Simonds, R. A.↗

Linear Anomaly in Welded 2219-T87 Aluminum Alloy

Study of causes and significance of two types of linear anomalies sometimes appearing in radiographs of welds described in preliminary report. Manifested as light or dark linear features parallel to weld line in radiograph of weld. Contains diagrams and descriptions of phenomena occurring during welding process. Includes microdensitometer traces from x-radiographs of actual welds and from computer simulations based calculation of x-ray transmission through assumed weld structures. Concludes anomalies not unique to 2219-T87 aluminum alloy.

Jemian, Wartan A.↗

Flow Trajectories in Friction Stir Welding

In the Friction Stir Welding (FSW) process, a rotating, shouldered tool with a threaded pin is inserted under pressure along the seam of two pieces of metal which are tightly clamped together, and secured against a rigid anvil underneath. The rotating pin travels along the seam and through a combination of pressure and friction heating produces a zone of plastic deformation around the pin within the workpiece on either side of the seam. As the pin is moved in the direction of welding, the plasticised material moves around the tool and bonds together behind it. The elements of the material flow behavior are a combination of three elements. There is a rotational transport of material being carried around the tool, extrusion of material being forced around the pin on both sides into the cavity created behind it, and a lifting and dropping of material as it is stirred and mixed by the rotating action of the pin. It was assumed that rotational motion of the plastic zone is the primary mechanism for transport of material around the welding tool. A kinematic mathematical model was used to compute trajectories of material movement for various distributions of rotational slip within the plastic zone. These trajectories were then compared with the results of an experiment that produced radiographs of markers embedded in a workpiece that was welded with the FSW process. It was assumed that the copper wire markers retained their original length as the aluminum material flowed around them. The kinematic model included a constraint so that the displacements were such that the total length of the wire markers did not increase after deformation. There was good agreement between the calculated trajectories for the case of localized slip at the outer surface of the plastic deformation zone and the radiographs of the copper wire markers. The trajectories differed markedly from the radiograph traces when a distributed slip zone was assumed. It was concluded that the flow field could be described generally by a rotating plug model with slip occurring on the surface at the outer boundary of the plastic zone.

Bernstein, Edward L.↗

Filmless Radiography

Technology initially prototyped under a Small Business Innovation Research contract between Quantex Corporation and Langley Research Center was licensed to Liberty Technology and incorporated into RADView, a new filmless radiography technology. The NASA-sponsored work involved the investigation of Electron Trapping, which led to a solid-state film that uses a special class of photoluminescent materials to capture radiographic images. RadView is a total imaging solution for the conversion of radiographic film records to digital format and digital acquisitions of radiographs. With the RADView technology, there is a reduction of exposure times and errors; film waste is eliminated; and the efficiency of data management and precise image analysis is boosted. The solid-state film can be exposed, read, erased, and re- exposed indefinitely until mechanical replacement is required. Digital images can be stored to optical media for up to 100 years and beyond without information loss.

Source record↗

Ultrasound Imaging of Spine: State of the Art and Utility for Space Flight

Introduction: Ultrasound imaging (sonography) has been increasingly used for both primary diagnosis and monitoring of musculoskeletal injury, including fractures. In certain injuries, sonography has been shown to equal or surpass Magnetic Resonance Imaging in accuracy. Long-term exposure to reduced gravity may be expected to cause physiological and anatomical changes of the musculoskeletal system, which are not fully described or understood. In a limited-resource environment like space flight, sonography will likely remain the only imaging modality; therefore, further attention to its potential is warranted, including its ability to image anatomical deviations as well as irregularities of vertebrae and the spinal column. Methods: A thorough review of literature was conducted on the subject. A multipurpose ultrasound system was used to identify specific vertebrae, intervertebral disks, and other structures of the cervical spine in healthy volunteers, selected to represent various age, gender, and Body Mass Index (BMI) groups. Sonographic views were sought that would parallel radiographic views and signs used in the diagnosis of cervical spine injuries. Results: While using widely accepted radiographic signs of cervical spine injury, this sonographic protocol development effort resulted in successful identification of scanning planes and imaging protocols that could serve as alternatives for radiography. Some of these views are also applicable to diagnosing degenerative disk and bone disease, and other non-traumatic spine pathology. Strong, preliminary correlation has been demonstrated in a number of clinical cases between sonography and other imaging modalities. Conclusion: In the absence of radiography, sonography can be used to diagnose or rule out certain common types of cervical spine conditions including injury. Clinical validation of the findings appears to be realistic and would facilitate establishment of new sonographic protocols for special environments with lacking radiographic capability, such as human space flight.

Sargsyan, Ashot E.↗

Advanced X-Ray Inspection of Reinforced Carbon Composite Materials on the Orbiter Leading Edge Structural Subsystem (LESS)

The post return-to-flight (RTF) inspection methodology for the Orbiter Leading Edge Structural Subsystem (LESS) is currently being defined. Numerous NDT modalities and techniques are being explored to perform the flight-to-flight inspections of the reinforced carbon/carbon (RCC) composite material for impact damage, general loss of mass in the bulk layers, or other anomalous conditions that would pose risk to safe return upon re-entry. It is possible to have an impact upon ascent that is not visually observable on the surface, yet causes internal damage. Radiographic testing may be a useful NDT technique for such occurrences. The authors have performed radiographic tests on full-sized mock samples of LESS hardware with embedded image quality phantoms. Digitized radiographic film, computed radiography and flat panel digital real-time radiography was acquired using a GE Eresco 200 x-ray tube, and Se-75 and Yb-169 radioisotopes.

Hernandez, Jose M.↗

Automatic method of material identification for computed tomography

A method is provided for isolating and labeling discrete features in a spectral radiographic image recorded as a set of images in different energy channels. The disclosed method involves creating a profile for each of at least some pixels in the spectral radiographic image. The profiles are sequences of pixel values, in which each pixel value is a photon count or a similar radiographic exposure value indicative of the attenuation of a portion of the scanning beam in a respective energy channel. Iterative hierarchical clustering is used to cluster the pixels on the basis of their respective profiles. Labels are assigned to one or more of the resulting clusters. In implementations, each label can be associated with an inferred material composition or with an inference that the material composition is unknown.

Jimenez, Jr., Edward Steven↗

Our teams design high-resolution MeV x-ray radiography systems for National security missions [Poster]

The NNSS has been at the forefront of custom high-fidelity x-ray/gamma radiographic imaging solutions that serve our national security for over five decades. Our radiography team utilizes expertise in physics modeling and analysis, along with optical, mechanical, and electrical design, in close collaboration with our customers, to develop imaging methods and capabilities that go beyond their needs. Conceptual designs are developed through R&D efforts to provide solutions for the specific problem at hand. Field systems are designed and built in-house, then qualified utilizing a range of facilities across the National Security Enterprise. Radiographic imaging systems are deployed by our team in the most challenging environments. The NNSS has a strong math and programming team that provides novel on-site image analysis methods that extract crucial information from data returned in field tests.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of fractal dimensions of rat bones from film and digital images

OBJECTIVES: (1) To compare the effect of two different intra-oral image receptors on estimates of fractal dimension; and (2) to determine the variations in fractal dimensions between the femur, tibia and humerus of the rat and between their proximal, middle and distal regions. METHODS: The left femur, tibia and humerus from 24 4-6-month-old Sprague-Dawley rats were radiographed using intra-oral film and a charge-coupled device (CCD). Films were digitized at a pixel density comparable to the CCD using a flat-bed scanner. Square regions of interest were selected from proximal, middle, and distal regions of each bone. Fractal dimensions were estimated from the slope of regression lines fitted to plots of log power against log spatial frequency. RESULTS: The fractal dimensions estimates from digitized films were significantly greater than those produced from the CCD (P=0.0008). Estimated fractal dimensions of three types of bone were not significantly different (P=0.0544); however, the three regions of bones were significantly different (P=0.0239). The fractal dimensions estimated from radiographs of the proximal and distal regions of the bones were lower than comparable estimates obtained from the middle region. CONCLUSIONS: Different types of image receptors significantly affect estimates of fractal dimension. There was no difference in the fractal dimensions of the different bones but the three regions differed significantly.

NASA Discipline Musculoskeletal↗

An approach to characterizing spatial aspects of image system blur

Quantitative X-ray radiographic imaging systems that utilize a charged couple device (CCD) camera connected to a thick, monolithic scintillator can exhibit blur that varies spatially across the field of view, especially for thick scintillators used in pulse-power radiography of dynamically compressed objects. Here, a three-point approach to estimating and accounting for this effect is demonstrated by (a) using a local estimation technique to measure the effect of blurring a calibration object at key locations across the field of view, (b) combining each of the local estimates into a spatially varying blurring function via partitions of unity interpolation, and (c) resolving the effects of that blur on the image by solving an ill-posed inverse problem using a spatially varying regularization term. The technique is demonstrated on synthetic examples and actual radiographs collected at the Naval Research Laboratory’s (NRL)Mercury pulsed power facility.

97 MATHEMATICS AND COMPUTING↗

Advanced Image Reconstruction for MCP Detector in Event Mode

A two-step data reduction framework is proposed in this study to reconstruct a radiograph from the data collected with a micro-channel plate (MCP) detector operating under event mode. One clustering algorithm and three neutron event back-tracing models are proposed and evaluated using both example data and a full scan data. The reconstructed radiographs are analyzed, the results of which are used to suggest future development.

Zhang, Chen↗