Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radiation testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Performance of commercial off-the-shelf microelectromechanical systems sensors in a pulsed reactor environment

Prompted by the unexpected failure of piezoresistive sensors in both an elevated gamma-ray environment and reactor core pulse tests, we initiated radiation testing of several MEMS piezoresistive accelerometers and pressure transducers to ascertain their radiation hardness. Some commercial off-the-shelf sensors are found to be viable options for use in a high-energy pulsed reactor, but others suffer severe degradation and even catastrophic failure. Although researchers are promoting the use of MEMS devices in radiation-harsh environment, we nevertheless find assurance testing necessary.

36 MATERIALS SCIENCE↗

Out-of-Pile Testing of Radiation Hard Optical Fibers

The work detailed in this report was supported under the In-Pile Instrumentation program for FY19. The work was conducted by researchers at Boise State University (BSU) and Idaho National Laboratory (INL). This report describes the out-of-pile testing that has been conducted to help guide sensor design and data interpretation by providing a robust understanding of out-of-pile fiber optic performance under different environmental factors. Highlighted in this report are two test configurations, transmission testing of optical fibers over a range of temperatures, and tensile testing of optical fibers identified through prior research as having potential for in-core use. The transmission temperature testing is conducted with high spectral resolution to study the influence of elevated temperatures on transmission. This testing has been conducted from room temperature up to 800ºC. The transmission testing was conducted by BSU at the Fiber Laser and Integrated photonics Research (FLaIR) laboratory. This testing will allow separation of radiation and temperature effects during in-core testing and allow for a more thorough understanding of radiation effects on fiber sensors. The tensile testing of optical fibers was conducted to provide a baseline for the strength of fiber optics. The fragile nature of glass fibers is a limitation in the deployment of fiber optics. Furthermore, intrinsic fiber optic sensors such as Fiber Bragg Gratings (FBG) add defects or damaged areas to the fiber which reduce its strength and can lead to broken sensors if not handled with care. The thermo-mechanical test facility enables the ability to quantitatively measure the strength of fibers with and without FBG’s over a temperature range. This information will be used to determine which types of FBG’s, and other sensors, are likely to survive the installation process. These tests will also be used to characterize the potential measurement range of fiber based strain sensors. The tensile testing was completed at INL in the HTTL Fiber Optics and Ultrasonic Technologies (FOUT) laboratory. Pure silica core (PSC) optical fibers have been shown to perform well in harsh environments. Transmission testing and tensile testing showed little change in fiber dynamic strength and transmission with elevated temperatures. There was no significant weakening of the fiber for temperatures up to 200ºC. Transmission at 1550 nm (a common wavelength used for optical sensors) showed minimal changes up to 800ºC with some improvement after 12 hours of annealing at 800ºC. This indicates that PSC optical fiber is a good candidate for in-pile testing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Variable-Temperature Cryostat For Radiation-Damage Testing Of Germanium Detectors

Variable-temperature cryostats developed to study radiation damage to, and annealing of, germanium gamma-ray detectors. Two styles: one accommodates large single detector and one accommodates two medium-sized detectors. New cryostats allow complete testing of large-volume germanium gamma-ray detectors without breaking cryostat vacuum and removing detectors for annealing.

Floyd, Samuel R.↗

Radiation Dose Testing on Juno High Voltage Cables

The Juno mission to Jupiter will have a highly elliptical orbit taking the spacecraft through the radiation belts surrounding the planet. During these passes through the radiation belts, the spacecraft will be subject to high doses of radiation from energetic electrons and protons with energies ranging from 10 keV to 1 GeV. While shielding within the spacecraft main body will reduce the total absorbed dose to much of the spacecraft electronics, instruments and cables on the outside of the spacecraft will receive much higher levels of absorbed dose. In order to estimate the amount of degradation to two such cables, testing has been performed on two coaxial cables intended to provide high voltages to three of the instruments on Juno. Both cables were placed in a vacuum of 5x10-6 torr and cooled to -50 C prior to exposure to the radiation sources. Measurements of the coaxial capacitance per unit length and partial discharge noise floor indicate that increasing levels of radiation make measurable but acceptably small changes to the F EP Teflon utilized in the construction of these cables. In addition to the radiation dose testing, observations were made on the internal electrostatic charging characteristics of these cables and multiple discharges were recorded.

Juno↗

Radiation Dose Testing on Juno High Voltage Cables

The Juno mission to Jupiter will have a highly elliptical orbit taking the spacecraft through the radiation belts surrounding the planet. During these passes through the radiation belts, the spacecraft will be subject to high doses of radiation from energetic electrons and protons with energies ranging from 10 keV to 1 GeV. While shielding within the spacecraft main body will reduce the total absorbed dose to much of the spacecraft electronics, instruments and cables on the outside of the spacecraft will receive much higher levels of absorbed dose. In order to estimate the amount of degradation to two such cables, testing has been performed on two coaxial cables intended to provide high voltages to three of the instruments on Juno. Both cables were placed in a vacuum of 5x10(exp -6) torr and cooled to -50(deg)C prior to exposure to the radiation sources. Measurements of the coaxial capacitance per unit length and partial discharge noise floor indicate that increasing levels of radiation make measurable but acceptably small changes to the F EP Teflon utilized in the construction of these cables. In addition to the radiation dose testing, observations were made on the internal electrostatic charging characteristics of these cables and multiple discharges were recorded.

partial discharge↗

Results of Tests on Radiators for Aircraft Engines

Part 1 is to present the results of tests on 56 types of core in a form convenient for use in the study of the performance of and possible improvements in existing designs. Working rules are given by which the data contained in the report may be used, and the most obvious conclusions as to the behavior of cores are summarized. Part 2 presents the results of tests made to determine the pressure necessary to produce water flows up to 50 gallons per minute through an 8-inch square section of radiator core. These data are of special value in evaluating the hydraulic head against which the circulating pump is required to operate.

Dickinson, H C↗

Decline in Radiation Hardened Microcircuit Infrastructure

Two areas of radiation hardened microcircuit infrastructure will be discussed: 1) The availability and performance of radiation hardened microcircuits, and, and 2) The access to radiation test facilities primarily for proton single event effects (SEE) testing. Other areas not discussed, but are a concern include: The challenge for maintaining radiation effects tool access for assurance purposes, and, the access to radiation test facilities primarily for heavy ion single event effects (SEE) testing. Status and implications will be discussed for each area.

performance of radiation hardened microcircuits↗

ECON-T and ECON-D: Endcap Concentrator ASICs for the CMS HGCAL

With over 6 million channels, the High Granularity Calorimeter (HGCAL) for the CMS HL-LHC Upgrade presents a unique data challenge. The ECON ASICs provide critical on-detector data reduction for the 40 MHz trigger path (ECON-T) and 750 kHz data acquisition path (ECON-D) of the HGCAL. The ASICs, fabricated in 65 nm CMOS, are rad-tolerant (600 Mrad) with low power consumption (<2.5 mW/channel). This presentation is the first comprehensive description of the ECON designs, first functionality and radiation tests for the ECON-T ASIC, and first results from the full production of 75k ECON-D and ECON-T ASICs.

Bergamin, G. [CERN] (ORCID:0000000285758704)↗

Radiation Hardness Tests of SiPMs for the JLab Hall D Barrel Calorimeter

We report on the measurement of the neutron radiation hardness of silicon photomultipliers (SiPMs) manufactured by Hamamatsu Corporation in Japan and SensL in Ireland. Samples from both companies were irradiated by neutrons created by a 1 GeV electron beam hitting a thin lead target at Jefferson Lab Hall A. More tests regarding the temperature dependence of the neutron radiation damage and self-annealing were performed on Hamamatsu SiPMs using a calibrated Am–Be neutron source from the Jefferson Lab Radiation Control group. As the result of irradiation both dark current and dark rate increase linearly as a function of the 1 MeV equivalent neutron fluence and a temperature dependent self-annealing effect is observed

Barrel calorimeter↗

Nevada Test Site Radiation Protection Program - Revision 1

Title 10 Code of Federal Regulations (CFR) Part 835, 'Occupational Radiation Protection,' establishes radiation protection standards, limits, and program requirements for protecting individuals from ionizing radiation resulting from the conduct of U.S. Department of Energy (DOE) activities. 10 CFR 835.101(a) mandates that DOE activities be conducted in compliance with a documented Radiation Protection Program (RPP) as approved by DOE. This document promulgates the RPP for the Nevada Test Site (NTS), related (on-site or off-site) U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office (NNSA/NSO) operations, and environmental restoration off-site projects. This NTS RPP promulgates the radiation protection standards, limits, and program requirements for occupational exposure to ionizing radiation resulting from NNSA/NSO activities at the NTS and other operational areas as stated in 10 CFR 835.1(a). NNSA/NSO activities (including design, construction, operation, and decommissioning) within the scope of this RPP may result in occupational exposures to radiation or radioactive material. Therefore, a system of control is implemented through specific references to the site-specific NV/YMP RCM. This system of control is intended to ensure that the following criteria are met: (1) occupational exposures are maintained as low as reasonably achievable (ALARA), (2) DOE's limiting values are not exceeded, (3) employees are aware of and are prepared to cope with emergency conditions, and (4) employees are not inadvertently exposed to radiation or radioactive material.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Large Detector Laboratory for the Development and Testing of Radiation Detection Systems

Thousands of radiation detection systems have been deployed over the last decade to domestic and international locations, primarily at ports of entry or departure. An essential ingredient in supporting sensor deployment is the capability to develop and test emerging systems and replicate the behavior of deployed systems. Pacific Northwest National Laboratory recently designed and constructed a laboratory for developing and testing these large-scale radiation detection systems. The Large Detector Laboratory is capable of housing up to 30 fully integrated radiation portal monitoring systems and allows for complex testing scenarios that include background suppression, equipment shielding, and source cross talk between systems. The laboratory design also allows implementation of applications ranging from pedestrian screening to baggage or package inspection to vehicle and cargo inspection to standoff detection. This manuscript describes the unique attributes of this laboratory that includes reproducing operational conditions faced by integrated systems, realistic source configurations and measurements across multiple systems.

laboratory↗

Test GammaPix™ Radiation Detection Software with Smartphones

GammaPix™ is a smartphone application that uses smartphone cameras to detect ionizing radiation. Brookhaven National Laboratory (BNL) evaluated the performance of the software in detecting radioactive materials. For this purpose, a series of tests were conducted at the Radiation Calibration Facility Annex at BNL. The experiments included dose measurements with three types of NIST-traceable calibration sources, 60Co, 241Am, and 137Cs. The recorded results by GammaPix™ were compared with the values measured by calibrated dosimeters to determine the detection thresholds. Several selected models of iPhones and Android cell phones with different pixel sizes and resolution were tested. In this paper, we present the test procedures and discuss the test results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dose rate effects in MOS microcircuits

Three read/write random access memories, AM91L24, HM1-6514, and MWS 5114, were subjected to total dose irradiation at three dose rates, with electrical testing after each increment of dosage. Annealing measurements were performed after the radiation tests were completed. The AM91L24 showed a strong dose rate effect and substantial post-irradiation annealing of radiation-induced damage. The dose rate effect was that a lower dose rate produced less net damage than an eqivalent total dose applied at a higher rate. The HM1-6514 showed essentially no dose rate effect and no annealing damage, and the MWS 5114 exhibited a moderate effect with some annealing. It was concluded that dose rate is an important parameter in radiation test procedures for MOS microcircuits and that annealing measurements may be important evaluation aids for such tests.

Cleveland, D. G.↗

Background and radiation resistance tests of neutral particle analyzer detectors for ITER by using a fast neutron beam

The radiation resistance and background sensitivity of scintillation (Hamamatsu H8500D photo-multiplier) and semiconductor (ORTEC BF-018-100-60 and BU-012-050-100) detectors to neutron and gamma radiation were investigated. Conclusions are drawn concerning the possibility of using such detectors in neutral particle analyzers that are being developed for ITER at the Ioffe Institute.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monitoring system for testing the radiation hardness of a KINTEX-7 FPGA

A much more efficient Ring Imaging Cherenkov sub-detector system will be rebuilt in the second long shutdown of Large Hadron Collider for the LHCb experiment. Radiation-hard electronic components together with Commercial Off-The-Shelf ones will be used in the new Cherenkov photon detection system architecture. An irradiation program was foreseen to determine the radiation tolerance for the new electronic devices, including a Field Programmable Gate Array from KINTEX-7 family of XILINX. An automated test bench for online monitoring of the XC7K70T KINTEX-7 device operation in radiation conditions was designed and implemented by the LHCb Romanian group.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗