Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radiation detection systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Development of an optical sensor for measuring opacity changes in polyvinyl toluene scintillators

Polyvinyl toluene (PVT) based detectors are used in radiation portal monitors (RPMs) worldwide to detect the trafficking of illicit nuclear material. PVT scintillators, which are normally optically clear, have been observed to suffer internal fogging throughout their volume due to prolonged exposure to varying environmental conditions. These changes could lead to reduced performance for RPMs that utilize plastic scintillators. In this research, a proof of concept system, consisting of different color light emitting diodes (LEDs) and a single optical sensor (OS), were used to examine the change in light transmission through a PVT scintillator. This Optical Monitoring System (OMS), coupled with an environmentally exposed PVT detector, was tested in an environmental chamber where it was subjected to changes in temperature and humidity ranging from 55 °C at 100% relative humidity to –20 °C at 40% relative humidity. At temperatures below 10 °C, light transmission was reduced by 81% ± 8% for blue LEDs, 84% ± 5% for yellow LEDs, and 49% ± 4% for green LEDs. Similar reductions in detected light were not recorded when the OMS was tested with only air between the LEDs and OS. Therefore, the significant reductions in transmitted light were attributed to changes occurring within the PVT scintillator. These results indicate that a significant reduction in PVT opacity occurs due to wide environmental changes. A device such as the OMS could be used to track these changes and provide users an early indication that a portal monitor is suffering from reduced performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

3D Frequency Domain Reflectometry Digital Twin of an Electrical Cable: A First Glance

Electrical cables within nuclear power plants (NPPs) are critical components required for power, control, and instrumentation systems which may be exposed to stressors, such as elevated temperatures and gamma radiation. Such stressors can lead to a reduction in the remaining useful life of electrical cables, jeopardizing the safety of NPP systems. To evaluate the effect of stressors on the degradation of electrical cables, electrical reflectometry methods are commonly employed. Frequency domain reflectometry (FDR) is a non-destructive electrical reflectometry method that uses transmission line theory to detect degradation or impedance changes within electrical cables. However, in most cases FDR is only applied to de-energized cables, limiting the application in NPPs as the cable system must be taken offline. In this work, we explore the development of an FDR digital twin to predict the degradation of an electrical cable exposed to elevated temperature, which is expected to reduce the need for offline FDR. A 3-conductor low-voltage electrical cable was selected for evaluation of the digital twin. The fully three-dimensional digital twin was developed in COMSOL using the RF module. A cable length of 30-m and frequency bandwidth of 400 MHz was selected to mimic real-world application of FDR. Over a 1-m region, the permittivity of the insulation was varied by up to 20% to model thermal degradation. The results demonstrate accurate detection of the insulation damage region, supporting further investigation of the FDR digital twin using real-world data and machine learning for predictive damage estimation or remaining lifetime.

Spencer, Mychal P.↗

SpecFIDLER User Manual: Software Version 2.4.0

The Spectroscopic Field Instrument for Detection of Low Energy Radiation (SpecFIDLER) allows response teams to detect and quantify plutonium contamination on the ground. Notional scenarios include dispersion from a weapon accident, or the launch failure of a space probe containing a radioisotope thermoelectric generator. Unlike other instruments, the thin-window sodium iodide detector is sensitive to the low-energy gamma rays emitted by plutonium isotopes. The system supports both mobile survey as well as stationary sampling. This manual provides information about installing, maintaining, and troubleshooting the SpecFIDLER. The scope of this document includes the physical hardware, software for data acquisition, and algorithms for data analysis. Recent changes to the software and algorithms aim to streamline the operation of the system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SpecFIDLER User Manual (Software V.2.5.0)

The Spectroscopic Field Instrument for Detection of Low Energy Radiation (SpecFIDLER) allows response teams to detect and quantify plutonium contamination on the ground. Notional scenarios include dispersion from a weapon accident, or the launch failure of a space probe containing a radioisotope thermoelectric generator. Unlike other instruments, the thin-window sodium iodide detector is sensitive to the low-energy gamma rays emitted by plutonium isotopes. The system supports both mobile survey as well as stationary sampling. This manual provides information about installing, maintaining, and troubleshooting the SpecFIDLER. The scope of this document includes the physical hardware, software for data acquisition, and algorithms for data analysis. Recent changes to the software and algorithms aim to streamline the operation of the system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SpecFIDLER User Manual (Software V.2.6.0)

The Spectroscopic Field Instrument for Detection of Low Energy Radiation (SpecFIDLER) allows response teams to detect and quantify plutonium contamination on the ground. Notional scenarios include dispersion from a weapon accident, or the launch failure of a space probe containing a radioisotope thermoelectric generator. Unlike other instruments, the thin-window sodium iodide detector is sensitive to the low-energy gamma rays emitted by plutonium isotopes. The system supports both mobile survey as well as stationary sampling. This manual provides information about installing, maintaining, and troubleshooting the SpecFIDLER. The scope of this document includes the physical hardware, software for data acquisition, and algorithms for data analysis. Recent changes to the software and algorithms aim to streamline the operation of the system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SpecFIDLER User Manual (Software V.2.3.0)

The Spectroscopic Field Instrument for Detection of Low Energy Radiation (SpecFIDLER) allows response teams to detect and quantify plutonium contamination on the ground. Notional scenarios include dispersion from a weapon accident, or the launch failure of a space probe containing a radioisotope thermoelectric generator. Unlike other instruments, the thin-window sodium iodide detector is sensitive to the low-energy gamma rays emitted by plutonium isotopes. The system supports both mobile survey as well as stationary sampling. This manual provides information about installing, maintaining, and troubleshooting the SpecFIDLER. The scope of this document includes the physical hardware, software for data acquisition, and algorithms for data analysis. Recent changes to the software and algorithms aim to streamline the operation of the system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Infrared optically stimulated luminescence of rare earth doped CaF 2 and co-doped with Al or Li produced by combustion synthesis

The aim of this paper is to characterize the IRSL response of rare earth doped CaF 2 and co-doped with Al or Li, produced by the solution combustion synthesis (SCS). The results showed a high intensity of the infrared optically stimulated luminescence (IRSL) response for the samples of CaF 2 doped with Tb and co-doped with Li. For the samples of CaF 2 doped with Ce and co-doped with Li present better IRSL response than the samples co-doped with Al. It was also observed that the samples of CaF 2 :Ce,Li present a high fading with 50% reduction of the IRSL signal in a period of 60 min. In case of the CaF 2 :Tb,Li there is no significant fading during this period. For clinical dosimetry the fast fading of the dosimeter is not adequate. However, this feature can be exploited for other applications such as tamper-proof passive systems that detect and timestamp the movement of undeclared nuclear materials, by the estimation of the OSL response of materials with different fading rates.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Bayesian Exploration and Surrogate Emulation of Nonlinear Beam-Response Geometry in the LBNF Beamline

Next-generation long-baseline neutrino experiments aim to achieve multi-MW proton beam power while reducing accelerator-induced systematic uncertainties. At Fermilab, the LBNF beamline is designed for 1.2 MW operation with PIP-II and is upgradeable to 2.4 MW. DUNE will probe the three-flavor neutrino paradigm and search for CP violation, requiring precise neutrino-flux normalization and improved control of accelerator-related uncertainties. Within the LBNF beamline, the System for On-Axis Neutrino Detection (SAND) will constrain flux uncertainties using precision near-detector measurements, while the Muon Monitor System (MuMS) will provide beamline diagnostics sensitive to the proton beam, target, and horn configuration. However, the pion phase space relevant for DUNE depends simultaneously on many correlated parameters, including beam centroid, beam width, horn current and alignment, target position, optics shifts, and radiation-induced changes. Consequently, MuMS observables exhibit nonlinear and coupled responses that are difficult to characterize using traditional one-parameter scans. To address this challenge, we are developing a Bayesian Exploration framework coupled to physics-informed surrogate emulators trained on Geant4 beamline simulations. Gaussian-process emulators provide both fast predictions and uncertainty estimates, enabling adaptive selection of new simulation points in beam-parameter space. As an initial demonstration, we construct surrogate emulators for MuMS response observables using a verified simulation campaign spanning proton-beam steering conditions. The emulators reproduce the simulated dependence of MuMS centroid and gradient observables while providing predictive uncertainties, and serve as the foundation for future multidimensional exploration including beam width, horn current, and additional beamline parameters. This work establishes a framework for uncertainty-aware beam monitoring, adaptive simulation campaigns, and rapid beam-response inference for future DUNE operations.

Ganguly, Sudeshna [Fermilab] (ORCID:00000003163482↗

Point Source Likelihood Framework (psl) v1.0

PSL is a software framework for localizing radiation point sources in a 3D environment using a freely moving radiation detector system. The framework assumes a single point source of radiation is in the environment and uses known detector positions and orientations along with their radiation measurements to find the most likely location of the point source. This approach to the problem enables analyses that improve upon the capability of a standard Maximum Likelihood Expectation Maximization (MLEM) approach, such as setting a source detection threshold, finding a likelihood interval for the position of the source, finding a likelihood interval for the activity (intensity) of the source, determining whether more than one point source may be present, and generating a map of Minimum Detectable Activity (MDA) for a given source type. Applications include radiological and nuclear security, consequence management, decontamination and decommissioning of nuclear facilities, and radiological emergency response.

Joshi, Tenzing↗

Time-interval distributions in a digital gamma multi-channel analyzer at extreme input rates

Here, this study explores the relationship between experimentally observed inter-event time-interval distributions (TIDs) and measured dead times for pulses generated by a HPGe gamma detector and processed by a digital spectrometer. The system utilizes a fast and slow channel, pile-up rejector, trapezoid filtering, and flash analog-to-digital converter. The experimentally derived TIDs were compared with theory for validation. The results demonstrate that the theoretical model reliably describes measured TIDs up to 40% dead time. However, significant distortion effects become increasingly pronounced at higher input rates. It appears that the deviation between the measured and calculated time-interval distributions take the shape of higher-order convolutions of the TID, which represent the time difference between counts for more than two successive events. In this work, theoretical functions for the TID are expanded to reproduce measurements up to 90%. This refinement in the interpretation and treatment of the measured TIDs provides improved accuracy and precision in the prediction of the true event rate and measured dead time in the counter. Even though it reflects occasional count loss that is specific to the set-up, it is expected that a similar adjustment may be applicable to other detection systems as well.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Observational Study of the Thermodynamics and Morphological Characteristics of a Midlatitude Continental Cold Pool Event

Abstract Convectively generated cold pools are important to the Earth system as they exert strong controls on deep convective-storm initiation, intensity, and life cycle. Despite their importance, efforts to introduce such cold pool controls into weather and climate models lack guidance and/or physical constraints from cold pool observations. This work presents a detailed, purely observational analysis of a cold pool event that took place on 23–24 May 2011 in north-central Oklahoma. The characteristics of the cold pool, and the spatiotemporal evolution of the hydrometeors and dynamics in the proximity of the cold pool, are studied with high-resolution observations. The unprecedented dataset used in this work to study cold pool characteristics includes an enhanced network of surface weather stations, a high-temporal-frequency sounding array, and the NEXRAD and Atmospheric Radiation Measurement (ARM) Southern Great Plains radar networks. The potential use of NEXRAD surveillance scans to estimate height and propagation speed of the leading edge of the cold pool (LECP) is presented in this work. Manual identification and tracking of the LECP from NEXRAD imagery shows a spatial and temporal heterogeneity of the LECP properties. Surprisingly, over its detected life cycle, the LECP speed remains almost constant, even though the strength of the cold pool diminishes in time and its height varies. Radar analysis shows that pulses of graupel and hail within downdrafts in the convective system generating the cold pool appeared to be related to temporary increases in the LECP height.

54 ENVIRONMENTAL SCIENCES↗

First direct observations of gear-changing in a collider

In this work we perform the first demonstration of gear-changing in a real world collider. Gear-changing refers to a collision scheme where each ring of a collider stores a different harmonic number of bunches. These bunches are kept synchronized using different velocities. Such a system has been theorized, but has now been demonstrated using the Double ElectroStatic Ion Ring ExpEriment (DESIREE) in Stockholm Sweden. The experiment was able to demonstrate a gear-changing system, with both four on three bunches and five on four bunches. We determined a measurable parameter that shows a gear-changing system out to $37500$ turns of the slow beam (1 second). We were also able to detect a measurable longitudinal beam-beam interaction. We developed insights into how to control this type of system, opening up new possibilities, and showing that DESIREE can be used for gear-changing research.

43 PARTICLE ACCELERATORS↗

12 C(p,p') 12 C Reaction ( E p =19.5–30 MeV) for Active Interrogation of Special Nuclear Material

Passive detection of special nuclear material (SNM) is challenging due to its inherently low rate of spontaneous emission of penetrating radiation, the relative ease of shielding, and the fluctuating and frequently overwhelming background. Active interrogation, the use of external radiation to increase the emission rate of characteristic radiation from SNM, has long been considered to be a promising method to overcome those challenges. Current active-interrogation systems that incorporate radiography tend to use bremsstrahlung beams, which can deliver high radiation doses. Low-energy ion-driven nuclear reactions that produce multiple monoenergetic photons may be used as an alternative. The 12 C ( p , p ' ) 12 C reaction is one such reaction that could produce large yields of highly penetrating 4.4- and 15.1-MeV gamma rays. This reaction does not directly produce neutrons below the approximately 19.7 MeV threshold, and the 15.1-MeV gamma-ray line is well matched to the photofission cross section of 235 U and 238 U . In this article, we report the measurements of thick-target gamma-ray yields at 4.4 and 15.1 MeV from the 12 C ( p , p ' ) 12 C reaction at proton energies of 19.5, 25, and 30 MeV. Measurements are made with two 3 -in. EJ-309 cylindrical liquid scintillation detectors and thermoluminescent dosimeters placed at 0 ° and 90 ° , with an additional 1.5 -in. Na I ( Tl ) cylindrical scintillation detector at 0 ° . We estimate the highest yields of the 4.4- and 15.1-MeV gamma rays of 1.65 × 10 10 and 4.47 × 10 8 sr - 1 μ C - 1 at a proton energy of 30 MeV, respectively. The yields in all experimental configurations are greater than in a comparable deuteron-driven reaction that produces the same gamma-ray energies— 11 B ( d , n γ ) 12 C . However, a significant increase of the neutron radiation dose accompanies the proton energy increase from 19.5 to 30 MeV.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Plasmonic photoconductive terahertz focal-plane array with pixel super-resolution

Abstract Imaging systems operating in the terahertz part of the electromagnetic spectrum are attractive due to their ability to penetrate many opaque materials and provide unique spectral signatures of various chemicals. However, the use of terahertz imagers in real-world applications has been limited by the slow speed, large size, high cost and complexity of present systems, largely due to the lack of suitable terahertz focal-plane array detectors. Here we report a terahertz focal-plane array that can directly provide the spatial amplitude and phase distributions, along with the ultrafast temporal and spectral information of an imaged object. It consists of a two-dimensional array of ~0.3 million plasmonic photoconductive nanoantennas optimized to rapidly detect broadband terahertz radiation with a high signal-to-noise ratio. We utilized the multispectral nature of the amplitude and phase data captured by these plasmonic nanoantennas to image different objects, including super-resolved etched patterns in a silicon substrate and defects in battery electrodes. By eliminating the need for raster scanning and spatial terahertz modulation, our terahertz focal-plane array offers more than a 1,000-fold increase in the imaging speed compared with the state of the art and potentially suits a broad range of applications in industrial inspection, security screening and medical diagnosis, among others.

Optics↗

Postearthquake Damage Mapping via Remote Sensing: Lessons From the 2023 Türkiye Disaster

This review addresses the urgent need for scalable, accurate, and reproducible remote sensing solutions following the February 2023 Türkiye earthquakes. It synthesizes the contributions of five peer-reviewed studies published in the IEEE JSTARS Special Issue on postearthquake damage and risk assessment. These studies cover areas such as damage classification with deep learning, fusion of multisource remote sensing data, creation of benchmark datasets, detailed damage mapping, and analysis of geophysical signals using outgoing longwave radiation. The article summarizes the methodological approaches and the practical relevance of the reviewed studies for detecting, evaluating, and quantifying damage, and outlines key challenges, including model generalization, class ambiguity, and data integration. It also discusses emerging trends, including explainable artificial intelligence, multimodal data fusion, and open-data platforms. This synthesis provides a foundation for building robust, interpretable, and real-time disaster response systems and aims to guide future research in earthquake-related Earth observation and rapid damage assessment.

Taskin, Gulsen [Istanbul Technical University] (OR↗

In-Device Delay: Introduction to Obscurant Physcial Protection System

The Office of Radiological Security (ORS) In-Device Delay (IDD) program has undertaken a project to research and develop a novel protection system for industrial irradiators that contain high-activity Co-60 sources. Based on adversary testing conducted by ORS, it is was determined that to successfully accomplish the theft of the target material, the adversary will require visual contact of the sources and source rack located at the bottom of the pool. Therefore, if a means of obscuring or visually hiding the sources in the pool can be achieved (while adhering to facility operations, safety, and regulatory requirements), then illicit source theft will be significantly hindered. This project aims to develop a low-cost, non-propriety obscurant that, when an adversary action is detected, the obscurant will be deployed into the pool quickly, rendering visual observation of the source problematic; however, this obscurant will not otherwise disturb the sources, source rack, and filtration system. The obscurant will remain in the pool until removed by another process.

61 RADIATION PROTECTION AND DOSIMETRY↗

Prompt Photofission Neutron Detection in Depleted Uranium

The detection of prompt photofission neutrons during active interrogation is a strong indication of the presence of special nuclear materials. However, the high-energy photons used for interrogation create a very challenging radiation environment for the detection of prompt fission signatures. These challenges include detector saturation and pulse pile-up. Additionally, there is an elevated neutron background that further challenges the detection of prompt fission neutrons. This background is produced because of (γ, Xn) photonuclear reactions in the surrounding high-Z materials. Here, we demonstrate the detection of prompt photofission neutrons in these challenging environments. Depleted uranium (DU) and lead targets are interrogated with bremsstrahlung photons produced by a 9-MV electron linear accelerator. Fast neutrons are detected with trans-stilbene organic detectors, and scintillation pulses are analyzed using a previously developed and demonstrated artificial neural network system. We observe a 5 times higher photoneutron count rate when the lead target is replaced with the DU target. Additionally, we observe a difference in the photoneutron light-output distributions of lead and DU. Here, this difference in the measured distributions is due to the difference in the photoneutron-energy spectra; DU photoneutrons are emitted with (γ, n) and watt-energy spectra, whereas lead photoneutrons are emitted with only the (γ, n) spectrum.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Advances in detection for neutron reflectometry with time-resolved imaging detectors

Thermal neutron detection in neutron scattering science is a challenging endeavour due to a limited number of technologies which are sensitive to these weakly interacting particles. While many improvements to conventional detectors are underway at various facilities, there is a great opportunity to make a leap in performance by combining the spatial resolution benefits of imaging and the temporal resolution and background discrimination of event-driven radiation detectors. This idea has been realized by using a neutron sensitive scintillator read out by a single-photon sensitive camera based on a Timepix3 ASIC. We demonstrate how such data-driven imaging sensors can enable unprecedented performance in neutron reflectometry using the ASTERIX instrument at the Los Alamos Neutron Scattering Center. Several samples were measured with both the new and a conventional 3 He detector systems. The results from this work demonstrate that these imaging based systems can satisfy performance parameters for the future QIKR reflectometer to be built at the Second Target Station at Oak Ridge National Laboratory. Further improvements to the detector are already underway which will allow streamlined and expedited experiments. We demonstrate at least a two order of magnitude increase in detection rate at an acceptable dead time and introduce a new way of tuning the detector efficiency using light collecting optics to accommodate highly intense direct beams which cannot be measured with any current detectors without severe attenuation. This will allow measurements of complete reflectometry profiles and using a single sample measurement combined with fewer direct beam calibration measurements on QIKR and potentially other reflectometers.

36 MATERIALS SCIENCE↗