Quantitative Analysis of Flow Processes in a Sand Using Synchrotron-Based X-ray Microtomography
Abstract not provided
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided
Abstract not provided
Abstract not provided.
Abstract not provided.
Abstract not provided.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
We determined simultaneously the domain wall speed (v) and the nucleation rate (N) of ferroelectric (FE) domain in 100-nm-thick epitaxial PbZr{sub 0.2}Ti{sub 0.8}O{sub 3} capacitors from the successive domain evolution images under various applied electric field (E{sub app}) by piezoresponse force microscopy. It was found that, at a given electric field, the v and N values decreased as the switching process proceeded. The averaged domain wall speed <v> was confirmed to follow the Merz's law, <v>exp[-(E{sub 0}/E{sub app})], with an activation field E{sub 0} of about 700 kV/cm. Moreover, we found that the nucleation process played a more important role in the FE domain switching at higher fields, while domain wall motion mainly contributed to the switching at lower fields.
We have improved methods reported earlier [1] for sample preparation, imaging and quantifying components in supported lipid bilayers using high-resolution secondary ion mass spectrometry performed with the NanoSIMS 50. By selectively incorporating a unique stable isotope into each component of interest, a component-specific image is generated from the location and intensity of the unique secondary ion signals exclusively produced by each molecule. Homogeneous supported lipid bilayers that systematically varied in their isotopic enrichment levels were freeze-dried and analyzed with the NanoSIMS 50. The molecule-specific secondary ion signal intensities had an excellent linear correlation to the isotopically labeled lipid content. Statistically indistinguishable calibration curves were obtained using different sample sets analyzed months apart. Fluid bilayers can be patterned using lithographic methods and the composition of each corralled region varied systematically by simple microfluidic methods. The resulting composition variations can be imaged and quantified. This approach opens the possibility of imaging and quantifying the composition of microdomains within membranes, including protein components, without using bulky labels and with very high lateral resolution and sensitivity.
Quantitative analysis of point defects is demonstrated through the use of multivariate statistical analysis. This analysis consists of principal component analysis for dimensional estimation and reduction, followed by independent component analysis to obtain physically meaningful, statistically independent factor images. Results from these analyses are presented in the form of factor images and scores. Factor images show characteristic intensity variations corresponding to physical structure changes, while scores relate how much those variations are present in the original data. The application of this technique is demonstrated on a set of experimental images of dislocation cores along a low-angle tilt grain boundary in strontium titanate. A relationship between chemical composition and lattice strain is highlighted in the analysis results, with picometer-scale shifts in several columns measurable from compositional changes in a separate column.
Quantitative analysis of fast-frame imagery of explosive aquarium shots can extract an abundance of information regarding the evolution of both the shock and the product gases following the passage of a detonation front. Analysis of the product gases (or any other surface of interest that lies within the shock and is observed from outside of the shock) is complicated by the fact that the water shock refracts the light in all three dimensions. This makes it necessary to correct for this refraction in order to get an accurate perception of the location of the surface and subsequently the velocities derived from the shape of that surface.
Rietveld quantitative phase analysis has become a widespread tool for the characterization of Portland cement, both for research and production control purposes. One of the major remaining points of debate is whether Portland cements contain amorphous content or not. This paper presents detailed analyses of the amorphous phase contents in a set of commercial Portland cements, clinker, synthetic alite and limestone by Rietveld refinement of X-ray powder diffraction measurements using both external and internal standard methods. A systematic study showed that the sample preparation and comminution procedure is closely linked to the calculated amorphous contents. Particle size reduction by wet-grinding lowered the calculated amorphous contents to insignificant quantities for all materials studied. No amorphous content was identified in the final analysis of the Portland cements under investigation.
This paper summarizes the risk assessment and management workflow developed and applied to the Southwest Regional Partnership on Carbon Sequestration (SWP) Phase III Demonstration Project. The risk assessment and management workflow consists of six primary tasks, including management planning, identification, qualitative analysis, quantitative analysis, response planning, and monitoring. Within the workflow, the SWP assembled and iteratively updated a risk registry that identifies risks for all major activities of the project. Risk elements were ranked with respect to the potential impact to the project and the likelihood of occurrence. Both qualitative and quantitative risk analyses were performed. To graphically depict the interactions among risk elements and help building risk scenarios, process influence diagrams were used to represent the interactions. The SWP employed quantitative methods of risk analysis including Response Surface Method (RSM), Polynomial Chaos Expansion (PCE), and the National Risk Assessment Partnership (NRAP) toolset. The SWP also developed risk response planning and performed risk control and monitoring to prevent the risks from affecting the project and ensure the effectiveness of risk management. As part of risk control and monitoring, existing and new risks have been tracked and the response plan was subsequently evaluated. Findings and lessons learned from the SWP’s risk assessment and management efforts will provide valuable information for other commercial geological CO2 storage projects.
High-resolution mass spectrometry (HRMS) in full scan mode acquires all ions present in the sample of interest offering a lot of qualitative information. This, in combination with the improved performance of the new generation HRMS systems, triggers more (bio) analysts to switch from triple quad MS systems to HRMS for quantitative analysis. Quantitative processing of HRMS data is performed based on narrow mass extraction windows rather than on nominal mass product ion chromatograms (SRM or MRM). Optimal processing of HRMS data requires different considerations and software tools and can have an impact on data processing and final results. The selection of centroid versus continuum/profile data for processing, selection of the optimal narrow mass extraction window, using theoretical versus measured accurate mass for the extraction of the ion chromatograms as well as differences in calculations and data handling residing in the different vendor software packages are tackled in the presented manuscript. These differences are illustrated on HRMS data acquired for the same plasma samples on three different platforms, i.e., a Sciex QToF, a Waters QToF, and a Thermo Orbitrap system, and processed in four different software packages, i.e., Sciex Analyst® TF, Waters Masslynx, Waters Unifi, and Thermo Xcalibur. The impact of these differences on quantitative HRMS performance was evaluated on calibration curves of eight small molecule compounds in plasma using four different ways of processing. Simple guidelines are provided for the selection of an optimal mass extraction window for continuum and centroided data. .
Critical infrastructure resilience has become a national priority for the U. S. Department of Homeland Security. System resilience has been studied for several decades in many different disciplines, but no standards or unifying methods exist for critical infrastructure resilience analysis. Few quantitative resilience methods exist, and those existing approaches tend to be rather simplistic and, hence, not capable of sufficiently assessing all aspects of critical infrastructure resilience. This report documents the results of a late-start Laboratory Directed Research and Development (LDRD) project that investigated the development of quantitative resilience through application of control design methods. Specifically, we conducted a survey of infrastructure models to assess what types of control design might be applicable for critical infrastructure resilience assessment. As a result of this survey, we developed a decision process that directs the resilience analyst to the control method that is most likely applicable to the system under consideration. Furthermore, we developed optimal control strategies for two sets of representative infrastructure systems to demonstrate how control methods could be used to assess the resilience of the systems to catastrophic disruptions. We present recommendations for future work to continue the development of quantitative resilience analysis methods.
A non-diffracting surface layer exists at any boundary of a crystal and can comprise a mass fraction of several percent in a finely divided solid. This has led to the long-standing issue of amorphous content in standards for quantitative phase analysis (QPA). NIST standard reference material (SRM) 676a is a corundum ({alpha}-Al{sub 2}O{sub 3}) powder, certified with respect to phase purity for use as an internal standard in powder diffraction QPA. The amorphous content of SRM 676a is determined by comparing diffraction data from mixtures with samples of silicon powders that were engineered to vary their specific surface area. Under the (supported) assumption that the thickness of an amorphous surface layer on Si was invariant, this provided a method to control the crystalline/amorphous ratio of the silicon components of 50/50 weight mixtures of SRM 676a with silicon. Powder diffraction experiments utilizing neutron time-of-flight and 25 keV and 67 keV X-ray energies quantified the crystalline phase fractions from a series of specimens. Results from Rietveld analyses, which included a model for extinction effects in the silicon, of these data were extrapolated to the limit of zero amorphous content of the Si powder. The certified phase purity of SRM 676a is 99.02% {+-} 1.11% (95% confidence interval). This novel certification method permits quantification of amorphous content for any sample of interest, by spiking with SRM 676a.
Crystallographic textures are pervasive in ferroelectrics and underpin the functional properties of devices utilizing these materials because many macroscopic properties (e.g., piezoelectricity) require a non-random distribution of dipoles. Inducing a preferred grain texture has become a viable route to improve these functional properties. X-ray and neutron diffraction have become valuable tools to probe crystallographic textures. This paper presents an overview of qualitative and quantitative methods for assessing crystallographic textures in electroceramics (domain and grain textures) and discusses their strengths and weaknesses.
X-ray photoelectron spectroscopy is an established technique for quantitative chemical analysis requiring accurate peak intensity analysis. We present evidence of focus/alignment dependence of relative peak intensities for peaks over a broad kinetic energy range with a hemispherical electron analyzer operated in a position imaging mode. A decrease of over 50% in the Ag 2p{sub 3/2} to Ag 3d ratio is observed in a Ag specimen. No focus/alignment dependence is observed when using an angular imaging mode, necessitating the use of angular mode for quantitative chemical analysis.