Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pump probe experiments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Theory for anomalous terahertz emission in striped cuprate superconductors

Recent experiments in the doped cuprates La 2−𝑥 ⁢Ba 𝑥⁢ CuO 4 have revealed the emission of anomalous terahertz radiation after impulsive optical excitation. Here, we theoretically investigate the nonlinear electrodynamics of such striped superconductors and explore the origin of the observed radiation. We argue that photoexcitation is converted into a photocurrent by a second-order optical nonlinearity, which is activated by the breaking of inversion symmetry in certain stripe configurations. We point out the importance of including umklapp photocurrents modulated at the stripe periodicity itself, which impulsively drive surface Josephson plasmons and lead to a resonant structure of outgoing radiation, consistent with the experiments. We speculate on the utility of the proposed mechanism in the context of generating tunable terahertz radiation.

36 MATERIALS SCIENCE↗

Ultrafast light-induced shear strain probed by time-resolved x-ray diffraction: Multiferroic BiFeO 3 as a case study

Enabling the light control of complex systems on ultrashort timescales gives rise to rich physics with promising applications. Although crucial, the quantitative determination of both the longitudinal and the shear photoinduced strains still remains challenging. Here, by scrutinizing asymmetric Bragg peaks pairs (±h01) in BiFeO 3 using picosecond time-resolved x-ray diffraction experiments, we simultaneously determine the longitudinal and shear strains. Importantly, we reveal a difference in the dynamical response of the longitudinal strain with respect to the shear one due to an interplay of quasilongitudinal and quasitransverse acoustic modes, well reproduced by our model. Lastly, we show that the relative amplitude of those strains can be explained only if both thermal and nonthermal processes contribute to the acoustic phonon photogeneration process.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Optical-pump–terahertz-probe spectroscopy in high magnetic fields with kHz single-shot detection

We demonstrate optical pump–THz probe (OPTP) spectroscopy with a variable external magnetic field (0–9 T), in which the time-dependent THz signal is measured by echelon-based single-shot detection at a repetition rate of 1 kHz. The method reduces data acquisition times by more than an order of magnitude compared to conventional electro-optic sampling using a scanning delay stage. The approach illustrates the wide applicability of the single-shot measurement approach to non-equilibrium systems that are studied through OPTP spectroscopy, especially in cases where parameters such as magnetic field strength (B) or other experimental parameters are varied. We demonstrate the capabilities of our measurement by performing cyclotron resonance experiments in bulk silicon, where we observe B-field-dependent carrier relaxation and distinct relaxation rates for different carrier types. We use a pair of economical linear array detectors to measure 500 time points on each shot, offering an equivalent performance to camera-based detection with possibilities for higher repetition rates.

Instruments & Instrumentation↗

Two-color polarization spectroscopy measurements of Zeeman state-to-state collision induced transitions of nitric oxide in binary gas mixtures

We investigated collision induced transitions in the (0, 0) band of the A2Σ+–X2Π electronic transition of nitric oxide (NO) using two-color polarization spectroscopy (TCPS). Two sets of TCPS spectra for 1% NO, diluted in different buffer gases at 295 K and 1 atm, were obtained with the pump beam tuned to the R11(11.5) and OP12(1.5) transitions. The buffer gases were He, Ar, and N2. The probe was scanned while the pump beam was tuned to the line center. Theoretical TCPS spectra, calculated by solving the density matrix formulation of the time-dependent Schrödinger wave equation, were compared with the experimental spectra. A collision model based on the modified exponential-gap law was used to model the rotational level-to-rotational level collision dynamics. A model for collisional transfer from an initial to a final Zeeman state was developed based on the difference in cosine of the rotational quantum number J projection angle with the z-axis for the two Zeeman states. Rotational energy transfer rates and Zeeman state collisional dynamics were varied to obtain good agreement between theory and experiment for the two different TCPS pump transitions and for the three different buffer gases. One key finding, in agreement with quasi-classical trajectory calculations, is that the spin-rotation changing transition rate in the A2Σ+ level of NO is almost zero for rotational quantum numbers ≥8. It was necessary to set this rate to near zero to obtain agreement with the TCPS spectra.

Chemistry↗

Phase transition kinetics of superionic H2O ice phases revealed by Megahertz X-ray free-electron laser-heating experiments

Abstract H 2 O transforms to two forms of superionic (SI) ice at high pressures and temperatures, which contain highly mobile protons within a solid oxygen sublattice. Yet the stability field of both phases remains debated. Here, we present the results of an ultrafast X-ray heating study utilizing MHz pulse trains produced by the European X-ray Free Electron Laser to create high temperature states of H 2 O, which were probed using X-ray diffraction during dynamic cooling. We confirm an isostructural transition during heating in the 26-69 GPa range, consistent with the formation of SI-bcc. In contrast to prior work, SI-fcc was observed exclusively above ~50 GPa, despite evidence of melting at lower pressures. The absence of SI-fcc in lower pressure runs is attributed to short heating timescales and the pressure-temperature path induced by the pump-probe heating scheme in which H 2 O was heated above its melting temperature before the observation of quenched crystalline states, based on the earlier theoretical prediction that SI-bcc nucleates more readily from the fluid than SI-fcc. Our results may have implications for the stability of SI phases in ice-rich planets, for example during dynamic freezing, where the preferential crystallization of SI-bcc may result in distinct physical properties across mantle ice layers.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Chemical pump study for Pioneer Venus program

Two chemical pumps were designed for the Pioneer Venus large probe mass spectrometer. Factors involved in the design selection are reviewed. One pump is designed to process a sample of the Venus atmosphere to remove the major component, carbon dioxide, so that the minor, inert components may be measured with greater sensitivity. The other pump is designed to promote flow of atmospheric gas through a pressure reduction inlet system. This pump, located downstream from the mass spectrometer sampling point, provides the pressure differential required for flow through the inlet system. Both pumps utilize the reaction of carbon dioxide with lithium hydroxide. The available data for this reaction was reviewed with respect to the proposed applications, and certain deficiencies in reaction rate data at higher carbon dioxide pressures noted. The chemical pump designed for the inert gas experiment has an estimated volume of 30 cu cm and weight of 80 grams, exclusive of the four valves required for the operation. The chemical pump for the pressure reduction inlet system is designed for a total sample of 0.3 bar liter during the Venus descent.

Rotheram, M.↗

Cross-Cutting Metrology Tools for In Operando Characterization of Carrier Dynamics in Photovoltaic Devices (Final Technical Report)

Understanding the nature of recombination and its dependence on defects and interfaces is essential for engineering materials and contacts for higher V oc and photovoltaic (PV) efficiency. Time-resolved photoluminescence (TRPL) has conventionally been used to evaluate recombination, but not all materials are strongly emissive or otherwise suitable. Time-resolved terahertz spectroscopy is a pump – probe method that presents valuable complementary information, wherein an optical pump pulse photoexcites carriers within the absorber and the transient photoconductivity is probed with a terahertz pulse. Until now, experimental constraints have prohibited the use of terahertz probes to interrogate full device stacks, and measurements were instead made on exfoliated films or films grown on unconventional substrates. However, interfaces are critical to the behavior of photoexcited carriers in solar cells, and the substrates themselves often influence the film growth and bulk properties. Therefore, it is important to probe the behavior of PV absorbers as close as possible to their normal operating conditions. Here we have developed cross-cutting metrology that enable in operando characterization of carrier dynamics and recombination mechanisms in working PV devices. Through a combination of complementary non-contact TRTS and TRPL experiments and modeling, we have obtained key parameters including photoexcited carrier bulk lifetime and interface and back surface recombination velocities with greater precision and accuracy than can be achieved with conventional TRPL alone. By varying pulsed photoexcitation conditions, the contributions of interface and bulk recombination mechanisms can be determined. We have developed and refined this characterization approach by investigating CdTe PVs, which is a well-established technology but with significant margin for further improvements in efficiency. Results were published in Journal of Applied Physics (DOI: 10.1063/5.0064730) and Proceedings of the IEEE PVSC (DOI: 10.1109/PVSC43889.2021.9518559). After validating the approach, we have applied it to correlate recombination rates to processing conditions and material properties, including composition and defects as well as interfaces and surface treatments. Such feedback can inform processing and design choices to enable higher PV efficiency, not only for CdTe, but also CdSe x Te 1-x , CIGS, perovskites, kesterites, and future technologies. A perspective on predicting solar cell performance from terahertz spectroscopy was published in Advanced Energy Materials (DOI: 10.1002/aenm.202102776). The cross-cutting metrology tools developed here will enable determination of the locus and mechanism of performance-limiting recombination in thin film PV devices. This feedback can guide the engineering of PV devices with higher V oc and efficiency, thereby leading to reductions in levelized cost of electricity to meet the SunShot 2030 target of $0.03/kWh for utility-scale PV. Lower costs will enable rapid expansion of renewable electricity generation that is nearly free of carbon emissions. Reducing carbon emissions of the electricity sector is one of the most important solutions to climate change. The project’s specific focus on CdTe PV can benefit First Solar, the US company that is the global leader in CdTe technology, through both technology and workforce development.

14 SOLAR ENERGY↗

Intersubband Relaxation in CdSe Colloidal Quantum Wells

The dynamics of intersubband relaxation are critical to quantum well technologies such as quantum cascade lasers and quantum well infrared photodetectors. In this work, intersubband relaxation in CdSe colloidal quantum wells, or nanoplatelets, is studied via pump-push-probe transient spectroscopy. An initial interband pump pulse is followed by a secondary infrared push excitation, resonant with intersubband absorption, which promotes electrons from the first conduction band of the quantum well to the second conduction band. A probe pulse monitors subsequent electron cooling to the band edge of the quantum well. Using this technique, intersubband relaxation is studied as a function of critical variables such as colloidal quantum well size and thickness, surface ligand chemistry, temperature, and excitation pulse intensity. Larger quantum well sizes, judicious selection of surface ligand chemistry (e.g., thiolates), low temperatures, and elevated push pulse fluences slow intersubband relaxation. However, compared to resonant intraband relaxation in colloidal quantum dots (up to hundreds of picoseconds), intersubband relaxation in colloidal quantum wells is rapid (<1 ps) under all examined conditions. These experiments indicate that rapid relaxation is driven by both LO phonon and surface scattering. The short time scale of relaxation observed in these materials may hinder intersubband technologies such as mid-infrared detectors, although such rapid relaxation may prove valuable in optical switching.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Complex Formation and Dissociation Dynamics on Amorphous Silica Surfaces

Benzene complex formation and dissociation dynamics with silanols on the amorphous silica surfaces of nanoporous SiO 2 , from a benzene/carbon tetrachloride solution, were measured by the growth of off-diagonal peaks in the two dimensional infrared (2D IR) chemical exchange spectrum of the isolated Si-OD stretch. The presence of two types of isolated silanols, referred to as type I and II, was revealed, with dissociation time constants of 82 ps and 4.0 ps for type I and II complexes, respectively. The type I silanols are associated with the main IR absorption feature in the Si-OD stretching region, while the type II silanols give rise to a broader shoulder to lower frequency. Polarization selective pump-probe (PSPP) measurements provided the vibrational lifetimes and orientational relaxation rates of the two silanols in the CCl 4 (free) and benzene (complex) environments. The type II silanols constitute roughly 30% of the isolated silanol population and exhibit a substantially faster rate of vibrational relaxation, making the type I dynamics the dominant contribution to the PSPP and 2D IR signals. From the measured dissociation times, the enthalpies of formation for the two surface complexes were obtained; the formation of the type I complex being significantly more exothermic. Furthermore, as the type II site is preferentially removed from the amorphous silica surface with increasing activation temperature, the results provide a reasonable explanation for the increased exothermicity of benzene adsorption on silica with increasing activation temperature in previous calorimetry experiments.

14 SOLAR ENERGY↗

Time-resolved X-ray Spectroscopy from the Atomic Orbital Ground State Up

X-ray spectroscopy has been a key method to determine ground and excited state properties of quantum materials with atomic specificity. Now, new x-ray facilities are opening the door to the study of pump-probe x-ray spectroscopy - specifically time-resolved x-ray absorption (trXAS) and time-resolved resonant inelastic x-ray scattering (trRIXS). In this paper we will present simulations of each of these spectroscopies using a time-domain full atomic multiplet, charge transfer Hamiltonian, adapted to study the properties of a generalized cluster model including a central transition metal ion caged by ligand atoms in a planar geometry. The numerically evaluated trXAS and trRIXS cross-sections for representative electron configurations 3d9 and 3d8 demonstrate the insights that can be obtained from charge transfer pumping, and how this nonequilibrium process affects ground and excited state properties. The straightforward characterization of the excitations in these systems, based on our analysis of the simulations, can serve as a benchmark for future experiments, as access to these time-resolved spectroscopic techniques becomes more widely available.

Jost, Daniel↗

Final Report on Development of Microwave Resonant Cavity Transducer for Fluid Flow Sensing: Development of Microwave Cavity Flow Meter for Advanced Reactor High Temperature Fluids

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with one of the flat walls of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the microwave resonant frequency, which can be detected with a spectrum analyzer. We have developed a continuum electromechanics model of the microwave resonant cavity transducer performance. The deflection of the membrane is calculated using equations from the theory of plates and shells for deflection of radially constrained thin circular disk under uniform load. The microwave frequency shift is calculated using the equations from the microwave cavity perturbation theory. The transducer model was validated with proof-of-concept experimental data of water flow sensing with a Brass 360 right circular cylinder with 22.2mm diameter and 203µm thick wall. The cavity was excited through a subwavelength hole in TE 011 mode with resonant frequency f ≈ 17.8GHz. Subsequently, we have performed a preliminary proof-of-principle test of flow sensing in high temperature liquid sodium in environment. For this test, we have developed a cylindrical resonator with the same dimensions as for the Brass 360 cavity. The resonator for high temperature liquid sodium test was machined from stainless steel 316 and electroplated with silver on the interior surfaces. We have also developed and insertion probe consisting of a 50cm WR-42 brass waveguide enclosed in a protective SS316 tube. The cavity was excited through a subwavelength hole on the side of the wall of the cylinder in the TE 011 mode with resonant frequency f ≈ 17.8GHz. The liquid sodium setup consists of a cylindrical vessel with a center feed line, where a transducer inserted through the top cap of the vessel measures velocity of the impinging liquid jet. The sodium flow sensing study was performed in a liquid sodium vessel at 340°C temperature and ambient pressure. The flow rate was changed by varying sodium pump power, and a frequency shift of several hundred kHz was observed. The transducer was removed after 70 days of testing. No visual damage was observed, and the electromagnetic response remained the same. As a calibration experiment, we have assembled a water vessel with a center feed, and with dimensions similar to those of the liquid sodium setup. Water flow sensing was performed before and after liquid sodium test. The responses in both cases are similar and agree with COMSOL computer simulations. Because long-term (multi-year) experimental tests of transducer resilience to harsh environment are not practical, we have developed a probabilistic model of creep to estimate transducer resilience to the harsh environment. The probabilistic model considers diffusion creep under the condition of high temperature and low stress, where the stress and temperature are allowed to be random variables with Gaussian distributions. Using the probabilistic model, we estimate inelastic membrane deflections due to creep for several temperature ranges. We conclude that for temperatures less than 650°C, creep has negligible long-term effect on the transducer performance.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Demonstration of Microwave Cavity Transducer Performance in High Temperature Fluid Flow Sensing: Development of Microwave Cavity Flow Meter for Advanced Reactor High Temperature Fluids

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with one of the flat walls of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the microwave resonant frequency, which can be detected with a spectrum analyzer. We have performed a preliminary proof-of-principle test of flow sensing in high temperature liquid sodium in environment, which is similar to that of an advanced reactor. The liquid sodium setup consists of a cylindrical vessel with a center feed line, where a transducer inserted through the top cap of the vessel measures velocity of the impinging liquid jet. For this test, we have developed a cylindrical resonator, which was machined from stainless steel 316 and electroplated with silver on the interior surfaces. Outer diameter of the cylindrical cavity is approximately 3cm, and the thin wall is approximately 200µm thick. We have also developed and insertion probe consisting of a 50cm WR-42 brass waveguide enclosed in a protective SS316 tube. The cavity was excited through a WR-42 waveguide through a subwavelength hole on the side of the wall of the cylinder in the TE 011 mode with resonant frequency f ≈ 17.8GHz. As a calibration experiment, we have assembled a water vessel with a center feed, and with dimensions similar to those of the liquid sodium setup. Frequency shift of the cavity spectral response was obtained at room temperature and ambient pressure by gradually increasing water flow rate from 0 to 25GPM (gallons per minute). Corresponding monotonic increase of resonant frequency by several hundred KHz was observed. Next, a sodium flow rate sensing study was performed in a liquid sodium vessel at 340° C temperature and ambient pressure. The flow rate was changed by varying sodium pump power, and a frequency shift of several hundred KHz was observed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Decoupling Carrier Dynamics and Energy Transport in Ultrafast Near-Field Nanoscopy

Ultrafast near-field optical nanoscopy has emerged as a powerful platform to characterize low-dimensional materials. While analytical and numerical models have been established to account for photoexcited carrier dynamics, quantitative evaluation of the associated pulsed laser heating remains elusive. Here, we decouple the photocarrier density and temperature increase in near-field nanoscopy by integrating the two-temperature model (TTM) with finite-difference time-domain (FDTD) simulations. These results reveal that the electron–phonon coupling in a silicon film after femtosecond laser excitation is most pronounced within approximately 3 ps–substantially shorter than the photocarrier decay time scale at tens of picoseconds. Moreover, the coupled TTM-FDTD method indicates that ultrafast laser heating can cause up to a 14% variation in the near-field signal at a 220 μJ/cm 2 pump pulse fluence. Our numerical results are further validated by transient experiments, highlighting the potential of this method for investigations of carrier and thermal phenomena in emerging nanomaterials and nanodevices.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Imaging the dynamics of initial laser-driven shocks and blowoff plasmas in polystyrene under laser-direct-drive fusion conditions

The dynamics of laser-driven shock propagation in solid ablator material, along with the concomitant processes of shinethrough and blowoff plasma plume expansion, at conditions relevant to laser-direct-drive fusion are measured using a tabletop system capable of supporting rapid dataset development with significantly higher resolution compared to existing methods. The experimental results are directly compared with current radiation-hydrodynamic simulations using the two-dimensional code . Discrepancies between experiments and simulations are evidenced and attributed to limitation of simulation to account for important processes involved in the solid-to-plasma transition. Published by the American Physical Society 2024

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Deviation from Debye-Waller behavior in single crystalline freestanding Ni⁢ O membranes studied via ultrafast electron diffraction

Here, we realize single-crystal freestanding Ni⁢O films on Si⁢N membranes, enabling thin-film scattering experiments with little or no substrate background signal. These membrane samples provide a critical platform for performing ultrafast electron diffraction (UED) to probe the response of the lattice to laser excitation. We show that epitaxial Ni⁢O films on a water-soluble Sr 2 ⁢Ca⁢Al 2⁢ O 6 buffer layer on Sr⁢Ti⁢O 3 substrates can be transferred as freestanding films to the Si⁢N membranes while maintaining the epitaxial character of the films. An above-gap photoexcitation (𝜆 =266 nm) incident on the sample stimulates an initial lattice response of the order of 1.1 ps, followed by the persistence of this state for more than 20 ps. We observe typical Debye-Waller behavior in peaks with 𝑞 above the (220) family, but a distinct deviation from this behavior is seen in low-𝑞 peaks. We relate this behavior to a dynamic decrease in sample mosaicity in response to the optical pump of the order of 3% that endures for approximately 4 ps. We suspect that this dynamic mosaicity is due to laser-induced strain propagation. This work demonstrates the viability of the thin-film transfer method for UED and paves the way for the study of the dynamic response of antiferromagnetic thin-film oxides.

Wisser, Jacob J. [Stanford Univ., CA (United State↗

Fatigue Crack Measurement in Composite Materials by Ultrasonic Methods

The nondestructive detection of intra-ply microcracking in unlined pressure vessels fabricated from composite materials is critical to ensuring mission success. Microcracking in composite structures due to combined fatigue and cryogenic thermal loading can be very troublesome to detect in-service and when it begins to link through the thickness can cause leakage and failure of the structure. These leaks may lead to loss of pressure/propellant, increased risk of explosion and possible cryo-pumping. The work presented herein develops a method and an instrument to locate and measure intraply fatigue cracking through the thickness of laminated composite material by means of correlation with ultrasonic resonance. Resonant ultrasound spectroscopy provides measurements which are, sensitive to both the microscopic and macroscopic properties of an object. Elastic moduli, acoustic attenuation, and geometry can all be probed. The approach is based on the premise of half-wavelength resonance. The method injects a broadband ultrasonic wave into the test structure using a swept frequency technique. This method provides dramatically increased energy input into the test article, as compared to conventional spike pulsed ultrasonics. This relative energy increase improves the ability to measure finer details in the materials character, such as micro-cracking and porosity. As the micro-crack density increases, more interactions occur with the higher frequency (small wavelength) components of the signal train causing the spectrum to shift toward lower frequencies. Preliminary experiments have verified a measurable effect on the resonance spectrum of the ultrasonic data to detect microcracking. Methods involving self organizing neural networks and other clustering algorithms show that the resonance ultrasound signatures from composites vary with the degree of microcracking and can be separated and identified.

Walker, James L.↗

Anisotropic X-Ray Scattering of Transiently Oriented Water

We study the structural dynamics of liquid water by time-resolved anisotropic x-ray scattering under the optical Kerr effect condition. In this way, we can separate the anisotropic scattering decay of 160 fs from the delayed temperature increase of ~ 0.1 K occurring at 1 ps and quantify transient changes in the O-O pair distribution function. Polarizable molecular dynamics simulations reproduce well the experiment, indicating transient alignment of molecules along the electric field, which shortens the nearest-neighbor distances. In addition, analysis of the simulated water local structure provides evidence that two hypothesized fluctuating water configurations exhibit different polarizability.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Elucidation of Free Radical and Optogalvanic Spectroscopy Associated with Microgravity Combustion via Conventional and Novel Laser Platforms

Combustion studies under both normal gravity and microgravity conditions depend a great deal on the availability and quality of the diagnostic systems used for such investigations. Microgravity phenomena are specially susceptible to even small perturbations and therefore non-intrusive diagnostic techniques are of paramount importance for successful understanding of reduced-gravity combustion phenomena. Several non-intrusive diagnostic techniques are available for probing and delineating normal as well as reduced gravity combustion processes, such as Rayleigh scattering, Raman scattering, Mie scattering, velocimetry, interferometric and Schlieren techniques, emission and laser-induced fluorescence (LIF) spectroscopy. Our approach is to use the LIF technique as a non-intrusive diagnostic tool for the study of combustion-associated free radicals and use the concomitant optogalvanic transitions to accomplish precise calibration of the laser wavelengths used for recording the excitation spectra of transient molecular species. In attempting to perform spectroscopic measurements on chemical intermediates, we have used conventional laser sources as well as new and novel platforms employing rare-earth doped solid-state lasers. Conventional (commercially available) sources of tunable UV laser radiation are extremely cumbersome and energy-consuming devices that are not very suitable for either in-space or in-flight (or microgravity drop tower) experiments. Traditional LIF sources of tunable UV laser radiation involve in addition to a pump laser (usually a Nd:YAG laser with an attached frequency-doubling stage), a tunable dye laser. In turn, the dye laser has to be provided with a dye circulation system and a subsequent stage for frequency-doubling of the dye laser radiation, together with a servo-tuning system (termed the 'Autotracker') to follow the wavelength changes and also an optical system (called the 'Frequency Separator') for separation of the emanating visible and UV beams. In contrast to this approach, we have devised an alternate arrangement for recording LIF excitation spectra of free radicals (following appropriate precursor fragmentation) that utilizes a tunable rare-earth doped solid state laser system with direct UV pumping. We have designed a compact and portable tunable UV laser system incorporating features necessary for both in-space and in-flight spectroscopy experiments. For the purpose of LIF excitation, we have developed an all-solid-state tunable UV laser that employs direct pumping of the solid-state UV-active medium employing UV harmonics from a Nd:YAG laser. An optical scheme with counterpropagating photolysis and excitation beams focused by suitable lenses into a reaction vacuum chamber was employed.

Misra, Prabhakar↗