Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pump efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

A Preliminary Investigation on the Performance of a Dual-Source Heat Pump using both the Air and the Ground

Air source heat pumps (ASHPs) and ground source heat pumps (GSHPs) are the two most common types of electric-driven heat pumps in the marketplace to replace fossil fuel-based heating systems. However, the performance and efficiency of ASHPs depend on the ambient air conditions. Therefore, ASHPs usually are equipped with electric resistance heaters to provide supplemental heating when the ambient temperature is low, and the heating demand is high. The electric resistance heaters could result in high power draws when they are turned on. On the other hand, due to the relatively steady temperature of the ground, GSHPs are more energy efficient than ASHPs when providing space heating and cooling to the buildings. However, the adoption of GSHP is hindered by its high initial cost, mostly due to the cost of drilling boreholes for installing ground heat exchangers (GHE). To solve the above issues, our study investigates the performance of dual-source heat pumps (DSHPs) with respect to that of ASHPs and GSHPs. The DSHP will use ambient air when its temperature is favorable for the efficient operation of the heat pump. When the ambient temperature is too hot or too cold, the ground source will be utilized to retain the high-efficiency operation of the heat pump. Because the cumulative thermal load of the GHE is shared with the ambient air, the size of the GHE could be smaller than those of the conventional GSHPs. The study will model the DSHP and simulate its performance in providing heating and cooling for a typical single-family house in regions with hot, mild, or cold climates. In addition, the required GHE size of the DSHP system will be determined through annual simulations and compared with that of conventional GSHPs.

Anees, Fady↗

Scalable and compact magnetocaloric heat pump technology

Magnetocaloric heat pumping (MCHP) promises to be more efficient than traditional vapor compression while also eliminating the deleterious effects of gaseous refrigerants. While MCHP devices have shown the temperature spans and efficiencies needed for different heating and cooling applications, they struggle to become commercially viable due to their large size and mass, and resultant high cost. This paper evaluates a baseline MCHP device and explores methods to boost its system power density (SPD). The key components of the baseline system are the gadolinium packed-particle bed active magnetic regenerator (AMR) and a magnetic source composed of permanent magnets and high permeability magnetic steel. To enhance the SPD, the paper evaluates maximizing the AMR volume, opting for first-order magnetocaloric materials, optimizing the magnet and AMR geometry, and reducing the size of magnets and magnetic steel parts. At larger thermal powers, increasing the AMR diameter and the number of magnetic poles were evaluated. Using finite element models, solid models, and estimates of magnetocaloric material performance, thermal powers ranging from 37 W to 44 kW at a nominal 10 K temperature span were projected, and SPD was estimated to improve from 6 W/kg to 81 W/kg. Neglecting end effects, an upper limit of 114 W/g is estimated. Compared to SPD of off-the-shelf compressors with similar environment temperatures, MCHP power density using gadolinium is competitive up to roughly 200 W of cooling power. This is extended to 1 kW when using LaFeSi alloys and up to 3 kW in the limiting case. In conclusion, these results indicate that the performance and mass of MCHP can match that of compressors, which is a critical step toward cost-competitive magnetocaloric technology.

42 ENGINEERING↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

Heating performance of a vapor compression heat pump cascaded with a thermoelectric heat pump

Air source heat pumps (ASHPs) are widely utilized for heating and cooling in residential buildings; however, their effectiveness in heating mode is compromised during extreme weather conditions. Extensive research endeavors have been undertaken to develop, test, and assess a cost-effective vapor compression ASHP suitable for cold climate regions. Further, this study takes an innovative approach by developing component and system prototypes for a cold climate heat pump. This design combines a thermoelectric heat pump (TEHP) with a traditional residential split ASHP to augment heating capacity in low ambient temperature conditions. The component and system prototypes underwent experimental testing in the psychrometric chambers. The experimental findings revealed a 13.6% to 13.7% increase in total heat pump heating capacity, accompanied by a 3.1% to 5.0% decrease in the coefficient of performance (COP) at ambient temperatures of -15°C and -19°C, when compared to the original ASHP. The COP of the TEHP is relatively constant, ranging from 1.63 to 1.76. This prototype offers a solution to address the challenges associated with reduced heat pump capacity at low ambient temperatures. The experimental results indicated that the lower the ambient temperature, thermoelectric heat pump auxiliary heating can increase the heating efficiency 60% in comparison to electric resistance.

42 ENGINEERING↗

ComStock Measure Scenario Documentation: Reduced Thermostat Setbacks for Heat Pumps

This report provides documentation of a measure for the End Use Savings Shapes project, which consists of analysis of different energy efficiency and renewable energy measures on the commercial building stock, using NREL's ComStock tool. The measure consists of a reduction in thermostat setbacks for air-source heat pump RTUs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design screening and analysis of gas-fired ammonia-based chemisorption heat pumps for space heating in cold climate

Thermally-driven ammonia-based chemisorption heat pumps (CSHP) have the potential to provide high-efficiency space heating in cold climates. Using the reversible chemical bond between sorbent salt and ammonia, CSHP thermochemically pumps heat from the cold ambient to the end-uses of space heating at 50 °C. The heating coefficient of performance (COP) of a CSHP largely depends on the selection of the sorbent salts, cycle configuration, and the system operation. This study uses a thermodynamic model to investigate the performance of six CSHP system configurations, including four single-effect and two double-effect cycles. The feasibility and performance of 121 available NH 3 /salt reactions are studied for each configuration. The thermal COP of the cycles and the primary energy COP of the gas-fired CSHP systems are evaluated assuming 50 °C supply temperature for building space heating and the optimal system designs are identified. The highest thermal COP for single-effect and double-effect cycles under -25 °C ambient temperatures are predicted to be 1.22 and 1.57, respectively. The corresponding primary energy COPs are above 1.0 and 1.15, which are 30% higher than condensing furnaces and is sustained into the same cold temperatures.

42 ENGINEERING↗

High-efficiency microwave-optical quantum transduction based on a cavity electro-optic superconducting system with long coherence time

Abstract Frequency conversion between microwave and optical photons is a key enabling technology to create links between superconducting quantum processors and to realize distributed quantum networks. We propose a microwave-optical transduction platform based on long-coherence time superconducting radio-frequency (SRF) cavities coupled to electro-optic optical cavities to mitigate the loss mechanisms that limit the attainment of high conversion efficiency. We optimize the microwave-optical field overlap and optical coupling losses in the design while achieving long microwave and optical photon lifetime at milli-Kelvin temperatures. This represents a significant enhancement of the transduction efficiency up to 50% under incoming pump power of 140 μW, which allows the conversion of few-photon quantum signals. Furthermore, this scheme exhibits high resolution for optically reading out the dispersive shift induced by a superconducting transmon qubit coupled to the SRF cavity. We also show that low microwave losses enhance the fidelity of heralded entanglement generation between two remote quantum systems. Finally, high precision in quantum sensing can be reached below the standard quantum limit.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Numerical Study of Liquid Piston Compression Using Large-Eddy Simulation and Volume-of-Fluid Approach

Efforts to increase the efficiency of residential and commercial air conditioners and heat pumps have demonstrated that the compressor accounts for most of the system’s electrical energy usage. Therefore, the efficiency of this component should be improved to reduce its energy usage. The US Department of Energy’s Oak Ridge National Laboratory developed a near-isothermal liquid piston compressor (LPC) that uses propylene glycol (PG) to compress CO2. This report presents numerical studies of the LPC in which the compression chamber fills with injected PG from the bottom inlet. Numerical simulations were performed using the large-eddy simulation (LES) with the wall-adapting local eddy-viscosity (WALE) subgrid-scale model coupled with the multiphase volume-of-fluid (VOF) model to simulate the transient interface between gas and liquid and to capture the heat and mass transfer within the compression chamber. In this effort, effects of boundary conditions applied to the LES-VOF calculations (e.g., no wall, an adiabatic wall, and a wall with a heat flux subscribed) to the overall pressure and temperature of CO2 gas as well as the transient evolution of flow and heat transfer evolution within the compression chamber are investigated and discussed. It was found that the LES calculation with no wall have shown no dynamical flow patterns and the volume-averaged temperature of CO2 increased from 305 to 392.7 K, while LES calculations with a constant wall temperature or a wall heat flux had similar increases of CO2 temperatures. Results of LES simulation using a wall heat flux showed different stages in the compression process and revealed dynamical formation and interaction of CO2 gas layers and circulation flow patterns within the chamber that contribute to the overall heat transfer between the solid wall, gas, and liquid surface in the compressor.

Nguyen, Thien D.↗

On-chip non-Hermitian optical parametric amplifiers with a large bandwidth

Recently, our groups have introduced the notion of optical parametric amplification based on non-Hermitian phase matching wherein the incorporation of loss can lead to gain in this nonlinear optical process. Previous simulation results using second-order nonlinear optical coupled-mode theory have demonstrated the potential of this technique as an alternative to the stringent phase-matching condition, which is often difficult to achieve in semiconductor platforms. Here we fortify this notion for the case of third-order nonlinearity by considering parametric amplification in silicon nanowires and illustrate the feasibility of these devices by employing rigorous finite-difference time-domain analysis using realistic materials and geometric parameters. Particularly, we demonstrate that by systematic control of the optical loss of the idler in a four-wave mixing process, we can achieve efficient unidirectional energy conversion from the pump to the signal component even when the typical phase-matching condition is violated. Importantly, our simulations show that a signal gain of ∼ <#comment/> 9 d B for a waveguide length of a few millimeters is possible over a large bandwidth of several hundreds of nanometers ( ∼ <#comment/> 600 n m ). This bandwidth is nearly 2 orders of magnitude larger than what can be achieved in the conventional silicon-photonics-based four-wave mixing process.

Ahmed, Asif (ORCID:0000000152234392)↗

South Texas Industrial Assessment Center (Final Report)

The South Texas Industrial Assessment Center (ST-IAC) provides small to mid-size manufacturing companies and water treatment plants in the Rio Grande Valley of Texas, free energy assessments to help them reduce costs and stay competitive for sustainable development. The ST-IAC operates within the University of Texas Rio Grande Valley (UTRGV), and is the largest Hispanic-serving IAC in the U.S. Created in 2016, the ST-IAC, situated in the most economically disadvantaged region in the country, has been successful in training students and assessing local industries served by a predominantly Hispanic population. UTRGV, now the second largest Hispanic Serving Institution (HSI) of higher education in the U.S., has a student population of 32,000, of which 90% is Hispanic. While Covid-19 had a negative impact to our program during Budget Periods (BP) 4 and 5, the center still managed to provide opportunities for individuals, manufacturing and water industries in the local region. The program developed an energy engineering program in the region and further advanced national priorities. Those include resilience and sustainability of operations by implementing energy efficiency processes, renewable energy sources, decarbonization, battery storage, and cybersecurity in south Texas.

14 SOLAR ENERGY↗

Tierra del Fuego Case Study Capacity Expansion Analysis

This case study, developed by Net Zero World Initiative and the Government of Argentina, examines least-cost decarbonization pathways for Tierra del Fuego, Argentina, utilizing renewable energy, energy storage, hydrogen, and other decarbonization technologies. Being the second largest natural gas producing province in Argentina, Tierra del Fuego has historically relied on natural gas for their energy sector needs. As they look at possible decarbonization pathways, they face challenges due to extreme weather conditions, isolation from the mainland, and low population density. The study utilizes the Engage web application for capacity expansion modeling, addressing both business-as-usual (BAU) and accelerated decarbonization scenarios, with varying degrees of electrification and carbon emission constraints. Key findings reveal that an interconnection with the mainland, high contribution of wind energy development on Tierra del Fuego, energy storage, and hydrogen, coupled with energy-efficient electrification technologies (such as heat pumps and electric vehicles), emerge as the most cost-effective solutions to decarbonize, significantly reducing carbon emissions and total system energy costs. The study explores self-generation and interconnection alternatives, demonstrating the economic advantage of an interconnection of Tierra del Fuego with the mainland, as an alternative to 100% local generation. Sensitivity analyses on wind data sources and temporal resolutions, as well as projected natural gas prices, highlight the influence of external factors on the feasibility of decarbonization pathways. Challenges identified include the practicality of phasing out natural gas, economic uncertainty, cost implications of long-term storage technologies as wind energy increases, and geographical limitations for wind generation. The case study concludes that while substantial emissions reductions can be achieved by 2050, and be competitive with conventional pathways, achieving a full 100% decarbonization by 2050 would entail higher costs, particularly due to the significant reliance on storage solutions with higher contribution of wind energy. The analysis offers valuable insights for policymakers and stakeholders in Argentina's energy sector, emphasizing the importance of strategic planning, investment in renewable energy and storage technologies, and careful consideration of local conditions in the transition towards Net Zero targets.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Design and Optimization of a Hybrid Design for Quantum Transduction

This study presents the mechanical design and analysis of a quantum electro-optical transducer engineered to operate at millikelvin temperatures within a dilution refrigerator. The transducer enables bidirectional microwave-optical frequency conversion through a hybrid architecture that integrates a superconducting radiofrequency (SRF) cavity with an electro-optic optical cavity. Among several design options investigated, the configuration offering the best thermal and mechanical performance was selected, yielding a robust solution with reduced sensitivity to fabrication tolerances, improved heat dissipation, as well as alignment precision. The design ensures uniform temperature distribution, enabling higher laser pump powers and, thus, increased conversion efficiency, while maintaining mechanical stresses safely below the material yield strength. Electromagnetic simulations further validate the design, demonstrating enhanced coupling between the optical and microwave modes, as well as a broader tuning range achieved with smaller tuner displacements.

quantum computing↗

Development of New g-function Data for Simulating a Novel Shallow Bore Ground Heat Exchanger

Geothermal heat pump (GHP), which is also referred as ground source heat pump, is the most energy-efficient technology for space heating and cooling. However, the application of GHP is hindered by its high initial cost, of which approximately 30% is for the ground heat exchanger (GHE). In recent years, researchers have developed different types of shallow bore ground heat exchangers (SBGHE) intending to reduce the cost of drilling. The ability to predict the thermal response of an SBGHE is critical for sizing SBGHE. While g-functions have been commonly used for predicting the thermal response of conventional vertical bore ground heat exchangers (VBGHE), they cannot be directly used for predicting the performance of SBGHE because they did not account for the impacts of the seasonal variation of the soil temperature along with the depth of an SBGHE. In addition, an SBGHE has a larger thermal mass within the borehole than the VBGHE due to the larger borehole diameter of SBGHE. This study develops new g-function data pairs for a new design of SBGHE, which is named Underground Thermal Battery (UTB). Impacts of the seasonal variation of soil temperature on the thermal response of UTB were accounted for by superposing a time-dependent soil temperature onto the g-functions calculated with a numerical model that assumes constant undisturbed soil temperature. The TOUGH program was used to predict the thermal response of several configurations involving multiple UTBs. The results indicate that the proposed methodology is appropriate to generate g-functions for the UTB, and the g-function value of UTB is much lower than that of VBGHE in the time range of 15 min to 1 year due to the large thermal mass and convection heat transfer within the UTB.

Shi, Liang↗

Multi-Kernel Adaptive Support Vector Machine for Scalable Predictive Maintenance

Application of data-driven solutions across an industry is challenging, since the data are often stored locally, and increasing privacy and security concerns restrict access to the data. In addition, it is highly unlikely that all potential data patterns are captured in a single data source. Because it is highly unlikely that all potential data patterns are captured in a single data source, machine learning (ML) models developed from a single source cannot be robust enough. An alternative is to train the ML model at each source and develop a distributed knowledge discovery and aggregation approach to build global knowledge. In this paper, we develop and demonstrate a distributed ML model, federated transfer learning (FTL), using a multi-kernel-based adaptive support vector machine (MK-A-SVM). For federated learning (FL), the multi-kernel (MK) approach enables feature-specific model aggregation under data heterogeneity; whereas for transfer learning (TL) the adaptive model enables utilization of an aggregated model from a different task. The proposed approach is validated using nuclear power plant (NPP) vertical motor-driven pump data to predict the health condition of vertical motor-driven pumps as an anomaly detection. The efficiency of the proposed approach is also quantified and compared with neural network.

42 ENGINEERING↗

Performance Evaluation of Drain Water Heat Recovery Exchangers for Heat Pump Water Heaters

Water heating constitutes approximately 18% of energy consumption and is the second largest energy expenses in United States homes. Heat pump water heaters (HPWHs) are energy efficient technologies with lower carbon footprints as compared to conventional water heating technologies, such as gas and electrical resistance heaters. The performance of water-source HPWHs can be improved by recovering heat from blackwater using drain heat recovery heat exchangers. Depending on water draw patterns of single family and multifamily residences, the operation and heat transfer performance of these heat exchangers are highly transient. This paper examines the thermo-hydraulic performance of a drain heat recovery heat exchanger during its transient and steady-state operations. The heat recovery performance of the exchanger was evaluated at different inlet temperatures and flow rates ranging from 9°C to 36°C and 0.03 kg/s to 0.28 kg/s, respectively. The obtained effectiveness varies from 45%–85% depending on the operating conditions. The test facility, steady-state and transient experimental procedures are reported in detail. Further, the effect of operating conditions on the effectiveness is discussed. The experimental approach and results of the study will provide insights into the transient operation of drain recovery heat exchangers as well as, guide sizing for various steady state conditions.

Krishnan, Easwaran↗

Hydraulic Testing of the Lost Lake Aquifer Near Recovery Well RWM001R

An aquifer pumping test was conducted on the Lost Lake Aquifer Zone (LLAZ) at the recently installed recovery well RWM001R in accordance with the approved test plan (Dixon, 2024). The objective of the testing was to determine baseline well performance parameters and aquifer hydraulic conductivity. This testing consisted of two step-drawdown tests to determine well performance properties and two constant pumping rate aquifer tests with recovery periods to determine aquifer hydraulic properties. Well performance parameters determined included specific capacity, well efficiency, and head loss coefficients. The results of the step-drawdown testing are presented in Tables ES1 and ES2 whereas the results of the constant pumping rate testing are presented in Table ES3. The average specific capacity of RWM001R operating at pump capacity (~54 gpm) was 2.2 gpm/ft using data from the final step of both tests. The average well efficiency determined from both step-drawdown tests was 56% using data from the final step of both tests. For both step-drawdown tests, well efficiency was inversely related to the pumping rate with the average efficiency decreasing from approximately 79% to 56%. Aquifer head loss coefficients from both tests were comparable (Table ES2).

54 ENVIRONMENTAL SCIENCES↗

Development and Testing of an Advanced Cascaded Thermoelectric Residential Heat Pump

Electricity-driven heat pumps using vapor compression cycle are an energy-efficient solution to replace fossil fuel burning and reduce greenhouse gas emissions for space heating in residential buildings. However, heating capacity and Coefficient of Performance (COP) of heat pumps degrade significantly with increasing temperature difference between ambient and indoor environments. Residents and building owners are hence reluctant to fully embrace electric heat pumps. The use of conventional all-electric heat pumps also causes concern for electric utilities due to an increased winter peak demand arising from the use of supplemental electric resistance heaters. Our research is an attempt to alleviate these concerns by designing and laboratory testing a thermoelectric (TE) heat pump cascaded with a vapor compression cycle to enhance heating capacity and COP. TE modules increase the subcooling in the refrigerant liquid of the vapor compression cycle to enlarge the evaporating capacity and works at an efficiency greater than a conventional electric resistance strip. This results in a simple, affordable, efficient and highly controllable solution to adequately meet space heating needs in dwellings. The laboratory testing of the 3-stage cascaded TE heat pump performed in this research has exhibited a higher heating capacity by above 15%, while maintaining a heating COP of 2.0-3.6 in the ambient temperature range of -18˚C to 8˚C (0˚F to 47 ˚F), which represents more than 60% of winter temperatures observed in US. If successfully commercialized, this technology can advance space-heating electrification by overcoming consumer cost barrier of heat pumps.

Shen, Bo↗