Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pump”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Semiconductor Laser Diode Pumps for Inertial Fusion Energy Lasers

Solid-state lasers have been demonstrated as attractive drivers for inertial confinement fusion on the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory (LLNL) and at the Omega Facility at the Laboratory for Laser Energetics (LLE) in Rochester, NY. For power plant applications, these lasers must be pumped by semiconductor diode lasers to achieve the required laser system efficiency, repetition rate, and lifetime. Inertial fusion energy (IFE) power plants will require approximately 40-to-80 GW of peak pump power, and must operate efficiently and with high system availability for decades. These considerations lead to requirements on the efficiency, price, and production capacity of the semiconductor pump sources. This document provides a brief summary of these requirements, and how they can be met by a natural evolution of the current semiconductor laser industry. The detailed technical requirements described in this document flow down from a laser ampl9ifier design described elsewhere. In brief, laser amplifiers comprising multiple Nd:glass gain slabs are face-pumped by two planar diode arrays, each delivering 30 to 40 MW of peak power at 872 nm during a {approx} 200 {micro}s quasi-CW (QCW) pulse with a repetition rate in the range of 10 to 20 Hz. The baseline design of the diode array employs a 2D mosaic of submodules to facilitate manufacturing. As a baseline, they envision that each submodule is an array of vertically stacked, 1 cm wide, edge-emitting diode bars, an industry standard form factor. These stacks are mounted on a common backplane providing cooling and current drive. Stacks are conductively cooled to the backplane, to minimize both diode package cost and the number of fluid interconnects for improved reliability. While the baseline assessment in this document is based on edge-emitting devices, the amplifier design does not preclude future use of surface emitting diodes, which may offer appreciable future cost reductions and increased reliability. The high-level requirements on the semiconductor lasers involve reliability, price points on a price-per-Watt basis, and a set of technical requirements. The technical requirements for the amplifier design in reference 1 are discussed in detail and are summarized in Table 1. These values are still subject to changes as the overall laser system continues to be optimized. Since pump costs can be a significant fraction of the overall laser system cost, it is important to achieve sufficiently low price points for these components. At this time, the price target for tenth-of-akind IFE plant is $0.007/Watt for packaged devices. At this target level, the pumps account for approximately one third of the laser cost. The pump lasers should last for the life of the power plant, leading to a target component lifetime requirement of roughly 14 Ghosts, corresponding to a 30 year plant life and 15 Hz repetition rate. An attractive path forward involes pump operation at high output power levels, on a Watts-per-bar (Watts/chip) basis. This reduces the cost of pump power (price-per-Watt), since to first order the unit price does not increase with power/bar. The industry has seen a continual improvement in power output, with current 1 cm-wide bars emitting up to 500 W QCW (quasi-continuous wave). Increased power/bar also facilitates achieving high irradiance in the array plane. On the other hand, increased power implies greater heat loads and (possibly) higher current drive, which will require increased attention to thermal management and parasitic series resistance. Diode chips containing multiple p-n junctions and quantum wells (also called nanostack structures) may provide an additional approach to reduce the peak current.

42 ENGINEERING↗

Submersible Blend Pump Mixing Evaluation

Savannah River Remediation (SRR) requested Savannah River National Laboratory (SRNL) to perform an engineering analysis to investigate the mixing behavior in feed blend tanks for the Salt Waste Processing Facility (SWPF). The baseline for mixing the feed blend tanks is a U 0 D of 5.1 ft 2 /s, a pump nozzle elevation of 165.86 inches above the sludge layer and 174 inches above the tank bottom, a liquid level 174.28 inches above the pump nozzle, and a blend time of 10.63 hours. The current Salt Batch Plan identifies Tanks 21, 26, 41, and 42 as the designated blend tanks. This supplemental study only addresses Type IIIA tanks (i.e., Tanks 26, 41, and 42). Using the Tank 41 current configuration as the baseline, the analysis considers the impact on blending if: 1) the distance between the pump discharge nozzle and the liquid surface increases above the baseline, 2) the distance between the pump discharge nozzle and the liquid surface decreases below the baseline, 3) the distance between the pump discharge nozzle and the sludge layer at the bottom of the tank increases above the baseline, or 4) the distance between the pump discharge nozzle and the sludge layer at the bottom of the tank decreases below the baseline, each while maintaining the minimum U 0 D of 5.1 ft 2 /s. Per subsequent direction from SRR, the minimum distance between the pump discharge nozzle and the sludge will be 165.86 inches. Hence, distances less than 165.86 inches between the pump discharge nozzle and the sludge were not included in the analysis. In addition, SRR requested SRNL to evaluate the impact of the abandoned in place, failed slurry pumps in Tank 42 on liquid blending.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Heat Transfer, Refrigeration and Heat Pumps

The Special Issue entitled “Heat Transfer, Refrigeration and heat Pumps” accepted papers covering a wide range of topics related to heat pumps, thermal energy storage, and low-Global Warming Potential (GWP) alternative refrigerants. Heat pumps play a vital role in providing space conditioning and water heating while utilizing the energy of the environment. Since heat pumps use renewable thermal energy from the environs to provide the desired utility, they contribute to the portfolio of technologies that mitigate carbon footprint. The heat pump may be considered a truly renewable technology if the electricity it uses comes entirely from a renewable source. More accurately, a heat pump is a “low carbon technology”. These perspectives make heat pumps an indispensable option for the future in order to reduce the nocuous human impact on the environment. More efficient heat pumping technologies are being developed for the residential, commercial, and industrial sectors of the economy. Another R&D thrust is heat pumps for cold climates. Hardware components, use of low-GWP refrigerants, and identification of systemic inefficiencies are active research areas. This article is a synopsis of the papers submitted to the Special Issue.

42 ENGINEERING↗

Method and device for remotely monitoring an area using a low peak power optical pump

A method and device for remotely monitoring an area using a low peak power optical pump comprising one or more pumping sources, one or more lasers; and an optical response analyzer. Each pumping source creates a pumping energy. The lasers each comprise a high reflectivity mirror, a laser media, an output coupler, and an output lens. Each laser media is made of a material that emits a lasing power when exposed to pumping energy. Each laser media is optically connected to and positioned between a corresponding high reflectivity mirror and output coupler along a pumping axis. Each output coupler is optically connected to a corresponding output lens along the pumping axis. The high reflectivity mirror of each laser is optically connected to an optical pumping source from the one or more optical pumping sources via an optical connection comprising one or more first optical fibers.

47 OTHER INSTRUMENTATION↗

Method and device for controlling heat pump

A method for controlling a heat pump is provided. A working mode of the heat pump is determined. Based on a determination that the working mode of the heat pump is a heating mode, an ambient temperature of the heat pump is determined. Based on a determination that the ambient temperature of the heat pump is higher than a first predetermined temperature, a first compressor of the heat pump is operated. Based on a determination that the ambient temperature of the heat pump is lower than the first predetermined temperature, both the first compressor and a second compressor of the heat pump are enabled to operate, in response to a two-stage thermostat. The first compressor and the second compressor are coupled in parallel. The method allows the heat pump to be suitable for a cold climate.

42 ENGINEERING↗

Development of a water source heat pump hardware-in-the-loop (HIL) testing facility for smart building applications

Over the last decade, the global fight against climate change through electrification has led to an increase in research on building heating, ventilation, and air conditioning (HVAC) systems that utilize intelligent control algorithms to provide demand-side grid service while maintaining the thermal comfort of building occupants. As the pivotalpoint between building electricity consumption and indoor thermal comfort, high-efficiency electrical heatpumps are at the center of these emerging studies, and various grid-interactive and occupant-comfort control algorithms have been developed for them. The impact of these algorithms on the heatpump operation andperformance under different weather, building load, and grid requests calls for investigation and verification via experimental tests with actual heat pumps integrated with real-time building and grid responses. This study presents a Water-Source Heat Pump Hardware-in-The-Loop (HIL) Test Facility developed with the capability to perform such tests. The hardware configuration for this testfacility introduces a hydronic system that emulates the conditions for the heat pump water-side, and a duct system that emulates conditions for the heat pump airside. Both data acquisition and emulator control are implemented through the National Instruments (NI) LabVIEW software running on an NI PXIplatform. The HIL mechanism based on the hardware-software integration that allows the testbed to communicate with a generic simulation environment is also discussed. Currently, the test facility setup includes a single heatpump and virtual building model in EnergyPlus coupled with an occupant behavioral model in MATLAB. Preliminary test results of the current setup demonstrate the building load emulator's ability to track the simulated gone temperature with a Root Mean Square Deviation (RSME) below 0.12°C (0.216°F). An uncertainty analysis based on sensor accuracies shows that the heat pump coefficient of performance (COP) can be measured with a relative uncertainty of 10.4% in cooling and 3.7% in heating. Apartfrom the current testing on a single heat pump, the test facility also provides the flexibility to include additional heat pumps to form a heat pump cluster, as well as coupling the heat pump with active thermal storage to provide enhanced demandflexibility.

Calfa, Caleb↗

Continued Testing and Modeling of the AirSquared All-Metal Tritium Scroll Pump

The implementation of fusion energy requires the processing of the deuterium-tritium mixture used to fuel the reaction. Many gas processing operations require either a gas-motive force or a pressure gradient across a system; both are achieved using vacuum pumps. However, because of the material challenges of working with tritium, specialized pumps are required that use only metal on wetted surfaces. This prevents tritium retention and degradation of materials such as oils and polymers and reduces the generation of tritiated waste. Typical gas handling systems for tritium operations involve metal bellows pumps, all-metal scroll pumps, and metal turbomolecular pumps, depending on the pressure requirements. With the industry standard Normetex Type 15 m 3 /h (typically referred to as the Normetex 15) pump no longer available, the fusion market requires viable alternatives. In this study, we test an American-made pump, the AirSquared V16H034A-C01, and compare its performance to the Normetex. A performance model of the AirSquared pump is also produced, which can be applied to general process models to generate an accurate description of pressures and flows through various unit operations.

08 HYDROGEN↗

Variable-Speed Pump Efficiency Calculation For Fluid Flow Systems with and without Static Head

To accurately calculate pump energy savings gained from implementing variable frequency drive (VFD) controls, the variation of pump efficiency must be considered when operating conditions transition from the design operating point to new operating points. Many software tools require users to specify the new pump efficiency, or it is assumed to be unchanged. Unfortunately, many users have challenges of estimating the pump efficiency at new operating points. This paper presents a simplified method of estimating centrifugal pump efficiency at new operating speeds when the pump is controlled by a VFD. This methodology applies to systems with and without static head when the system curve is not affected by the change, and also systems where the change in operation changes the system curve.A hypothetical fluid flow system and centrifugal pump were used to demonstrate the calculation process for these scenarios. For this hypothetical system, the pump’s efficiency at new operating points was up to 5.4% lower than the design operating point.

42 ENGINEERING↗

Experimental study of R452B and R454B as drop-in replacement for R410A in split heat pumps having tube-fin and microchannel heat exchangers

The objective of this study is to experimentally evaluate two residential split heat pumps using low-GWP refrigerants, i.e., R452B and R454B, and compare the results against R410A. In this work, each heat pump used the same model of two-speed scroll compressor, the same indoor blower and outdoor fan. However, they were distinguished by the indoor and outdoor heat exchanger types: tube-fin heat exchangers (TFHXs) in one case, and microchannel heat exchangers (MCHXs) in the other. The two heat pumps were extensively evaluated following the test conditions for two-speed SEER (cooling seasonal energy efficiency rating)/HSPF (heating seasonal performance factor) ratings.In general, these results show that R452B and R454B are good replacement candidates for R410A for heat pump using tube-fin heat exchangers and microchannel heat exchangers. R452B and R454B led to lower capacities. In the TFHX heat pump, on average, compared to the performance of R410A, the cooling capacity of R452B is 96%; the heating capacity of R452B is 91%; the cooling capacity of R454B is 95%, the heat capacity of R454B is 89%. In the MCHX heat pump, the cooling capacity of R452B is 97%; the heating capacity of R452B is 97%; the cooling capacity of R454B is 98%, the heat capacity of R454B is 97%. With respect to cooling and heating seasonal performances, in the TFHX heat pump, the SEERs of R452B and R454B are 1.5% lower than R410A. HSPFs of the three refrigerants are identical. In the MCHX heat pump, R454B has 7% higher SEER, and R452B has 2% higher SEER than R410A; in heating mode, R454B has the same HSPF as R410A, while R452B is 4% more efficient. The compressor lubricant overheating issue of R452B and R454B, at low ambient heating condition, high stage, should be noticed.

42 ENGINEERING↗

Advances in supervisory control strategies for a heat pump centric HVAC system − a comprehensive review on applications

There is an increase in research investigating the development and deployment of supervisory controllers that enable high efficiency electrically driven vapor compression heat pumps operating within grid interactive efficient buildings to provide demand side management. This paper reviews over sixty relevant case studies within this domain that focus on commercial off-the-shelf heat pumps whose primary task is providing space conditioning. The concept of a heat pump-centric heating, ventilation, and air-conditioning system is introduced, accompanied by a detailed overview of various kinds of electric heat pumps and building-level thermal energy storage configurations. Additionally, the different types of supervisory controller designs, including rule-based control and model predictive control, are discussed, along with the various methods for communication between a supervisory controller and a downstream heat pump’s local controller. A comparative analysis is conducted in order to categorize the reviewed case studies based on their system design, supervisory control algorithm, and validation methodology. This detailed analysis allows the review to establish current research trends, identify potential gaps, and suggest future directions for the development of this technology. Overall, the authors recommend that more future research be devoted to low-cost practical retrofits that allow for easy integration of active thermal energy storage within heat pump-centric heating, ventilation, and air-conditioning system systems that utilize direct expansion heat pumps. We also suggest more research into the development and deployment of supervisory controllers that can properly communicate with commercial off-the-shelf heat pump local controller available control inputs, e.g., zone temperature setpoint. Lastly, more rigorous experimental demonstrations of advanced supervisory control within real and or closed-loop, transient/ quasi-steady state environments are necessary to reduce industry wide skepticism of this technology.

Demand side management↗

Experimental study of characteristic curves of centrifugal pumps working as turbines in different specific speeds

Pump manufacturers do not normally provide the characteristic curves of their pumps working as turbines. Therefore, establishing a correlation between the performances of direct (pump) and reverse (turbine) modes is essential in selecting the proper machine. In this paper, several centrifugal pumps (N{sub s} < 60 (m, m{sup 3}/s)) were tested as turbines. Using experimental data, some relations were derived to predict the best efficiency point of a pump working as a turbine, based on pump hydraulic characteristics. Validity of the presented method was shown using some referenced experimental data. Two equations were presented to estimate the complete characteristic curves of centrifugal pumps as turbines based on their best efficiency point. Deviations of suggested method from experimental data were considered and discussed. Finally, a procedure was presented for selecting a suitable pump to work as a turbine in a small hydro-site. (author)

13 HYDRO ENERGY↗

The influence of Reynolds numbers on resistance properties of jet pumps

Jet pumps are widely used in thermoacoustic Stirling heat engines and pulse tube cryocoolers to eliminate the effect of Gedeon streaming. The resistance properties of jet pumps are principally influenced by their structures and flow regimes which are always characterized by Reynolds numbers. In this paper, the jet pump of which cross section contracts abruptly is selected as our research subject. Based on linear thermoacoustic theory, a CFD model is built and the oscillating flow of the working gas is simulated and analyzed with different Reynolds numbers in the jet pump. According to the calculations, the influence of different structures and Reynolds numbers on the resistance properties of the jet pump are analyzed and presented. The results show that Reynolds numbers have a great influence on the resistance properties of jet pumps and some empirical formulas which are widely used are unsuitable for oscillating flow with small Reynolds numbers. This paper provides a more comprehensive understanding on resistance properties of jet pumps with oscillating flow and is significant for the design of jet pumps in practical thermoacoustic engines and refrigerators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Understanding and eliminating artifact signals from diffusely scattered pump beam in measurements of rough samples by time-domain thermoreflectance (TDTR)

Time-domain thermoreflectance (TDTR) is a pump-probe technique frequently applied to measure the thermal transport properties of bulk materials, nanostructures, and interfaces. One of the limitations of TDTR is that it can only be employed to samples with a fairly smooth surface. For rough samples, artifact signals are collected when the pump beam in TDTR measurements is diffusely scattered by the rough surface into the photodetector, rendering the TDTR measurements invalid. In this paper, we systemically studied the factors affecting the artifact signals due to the pump beam leaked into the photodetector and thus established the origin of the artifact signals. We find that signals from the leaked pump beam are modulated by the probe beam due to the phase rotation induced in the photodetector by the illumination of the probe beam. As a result of the modulation, artifact signals due to the leaked pump beam are registered in TDTR measurements as the out-of-phase signals. We then developed a simple approach to eliminate the artifact signals due to the leaked pump beam. We verify our leak-pump correction approach by measuring the thermal conductivity of a rough InN sample, when the signals from the leaked pump beam are significant. We also discuss the advantages of our new method over the two-tint approach and its limitations. Our new approach enables measurements of the thermal conductivity of rough samples using TDTR.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validation of density pump-out by pedestal-foot magnetic island formation prior to ELM suppression in KSTAR and DIII-D tokamaks

Abstract TM1 nonlinear two-fluid simulations reveal key characteristics of density pump-out caused by pedestal-foot island formation when applying resonant magnetic perturbation (RMP). These characteristics include a bifurcation in pump-out with a low RMP coil current threshold, a sensitivity of pump-out magnitude to q 95 , and the magnitude of pump-out scaling as the square root of the RMP coil current. Dedicated experiments are carried out in the KSTAR and DIII-D tokamaks to validate these features and show that: (1) a staircase bifurcation in density pump-out is observed when slowly ramping up the n = 1 RMP current, and the density fluctuations are found to be slightly decreased from the pedestal-foot to the pedestal-top; (2) the magnitude of density pump-out becomes weaker when decreasing q 95 from 5.5 to 4.9, and a partial recovery of density pump-out is observed when q 95 is ramped down to lower than 4.9; and (3) analysis of a DIII-D database of n = 3 RMP edge-localized mode control experiments finds that the magnitude of density pump-out is proportional to the square root of RMP coil current Δ n e / n e ∝ I RMP 0.5 . These experimental observations are consistent with TM1 simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SLURRY PUMP MIXING EFFECTIVENESS IN TANK 50H

Computational Fluid Dynamics (CFD) models of Tank 50 with different numbers of pumps and operational modes, including pump rotation, have been developed to estimate flow patterns and the resultant sludge mixing. Major solid obstructions including the tank wall, the pump housing, the pump columns, and the 82-in central support column were included in the model. Transient analyses with a two-equation turbulence model were performed with FLUENT{trademark}, a commercial CFD code. All analyses were based on three-dimensional results. Recommended operational guidance was developed assuming that local fluid velocity and characteristic measures of local turbulence could be used as indicators of sludge suspension and spatial mixing. The calculation results show that three pumps, the maximum number of pumps studied, will give acceptable homogeneous mixing in about 6 minutes in terms of flow patterns and turbulent energy dissipation. These qualitative results are consistent with literature results. Sensitivity calculations have also been performed to assess the impact of different operating modes on sludge suspension and mixing. Two-pump operation provides a marginal level of sludge suspension and turbulent mixing, while one pump does not provide acceptable flow patterns and turbulent eddies for good mixing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Final Technical Report: Electromagnetic Pump Insulation Materials Development and Testing (PLM-DOC-0005-2465) Report # DOEGEHB00613

Final Technical Report: Electromagnetic Pump Insulation Materials Development and Testing (Report # DOEGEHB00613) summarizes the information gathered from the analysis of the 160 m3/min EM Pump insulation that was tested in 2000-2002 and additional evaluations of new resilient, engineered insulation system evaluated and tested at both GRC and ANL. This report provides information on Tasks 1 and 2 of the entire project. This report also provides information in three broad areas: Historical and current data; Conclusions based on test data; and Insulation specifications for use in EM Pumps. The research for Task 2 builds upon Task 1: Update EM Pump Databank, which is summarized within this report. Where research for Task 3 and 4 Next-Generation EM Pump Analysis Tools identified parameters or analysis model that benefits Task 2 research, those items are noted within this report. The important design variables for the manufacture and operation of an EM Pump that the insulation research can evaluate are: space constraints; voltage capability of insulation system; maximum flux density through iron; flow rate and outlet pressure; efficiency and manufacturability. The development summary of the Electromagnetic Pump Insulation Materials Development and Testing was completed to include: Historical and current data; Conclusions based on test data; and Insulation specifications for use in EM Pumps.

36 MATERIALS SCIENCE↗

MODELING AND OPTIMIZATION STUDY OF A TIGHTLY INTEGRATED ROTARY ELECTRIC MOTOR-HYDRAULIC PUMP

To meet the growing trend of electrification of mechanical systems, this paper presents a compactly integrated electric motor and hydraulic pump. The proposed application for this machine requires high flow rates at low pressure differentials and four quadrant operation. The hydraulic pump architecture selected for this machine is a radial ball piston pump. An inside impinged version of this architecture allows for efficient filling of the chambers and is radial balanced, both of which allow high- speed operation for increased power density. The radial ball piston pump is less expensive to manufacture and is radially more compact than a standard radial cylindrical piston pump. A model of the pump and the integrated electric motor have been created to study scaling relationships and drive detailed design and optimization. The scaling study considers how displacement is affected by pump diameter, and how the diameter and required torque change with angular velocity. The detailed model considers the effect of valve timing, piston-cylinder clearance, and pump geometry on the efficiency. The model is then exercised in an optimization of the machine parameters.

30 DIRECT ENERGY CONVERSION↗

Size Up or Size Down? National Analysis of Heat Pump Sizing and Impacts

Electrification of on-site fossil fuel combustion in buildings is recognized as a key component of achieving global greenhouse gas emissions targets. Air-source heat pumps are an efficient approach for space heating electrification. However, a major barrier to heat pump adoption is the high installation cost relative to furnaces and air conditioners. Because the installation cost of heat pumps - especially cold climate models - is dependent on their size, it is important to understand the distribution of heat pump sizes using different sizing methods and factors that impact heat pump sizing. In this study, we use sub-hourly physics simulations of 550,000 statistically representative dwelling units to analyze the distribution of heat pump size in the U.S. for three different efficiency levels of heat pumps, with and without building insulation and air sealing upgrades. We will present results from the national analysis of different factors affecting heat pump sizing along with the impact of sizing decisions on upgrade costs and operating costs.

electrification↗