Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pulse shaping”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Exploring wave propagation in heterogeneous metastructures using the relaxed micromorphic model

Metamaterials are artificial structures that can manipulate and control sound waves in ways not possible with conventional materials. While much effort has been undertaken to widen the bandgaps produced by these materials through design of heterogeneities within unit cells, comparatively little work has considered the effect of engineering heterogeneities at the structural scale by combining different types of unit cells. In this paper, we use the relaxed micromorphic model to study wave propagation in heterogeneous metastructures composed of different unit cells. We first establish the efficacy of the relaxed micromorphic model for capturing the salient characteristics of dispersive wave propagation through comparisons with direct numerical simulations for two classes of metamaterial unit cells: namely phononic crystals and locally resonant metamaterials. We then use this model to demonstrate how spatially arranging multiple unit cells into metastructures can lead to tailored and unique properties such as spatially-dependent broadband wave attenuation, rainbow trapping, and pulse shaping. In the case of the broadband wave attenuation application, we show that by building layered metastructures from different metamaterial unit cells, we can slow down or stop wave packets in an enlarged frequency range, while letting other frequencies through. In the case of the rainbow-trapping application, we show that spatial arrangements of different unit cells can be designed to progressively slow down and eventually stop waves with different frequencies at different spatial locations. Finally, in the case of the pulse-shaping application, our results show that heterogeneous metastructures can be designed to tailor the spatial profile of a propagating wave packet. Collectively, these results show the versatility of the relaxed micromorphic model for effectively and accurately simulating wave propagation in heterogeneous metastructures, and how this model can be used to design heterogeneous metastructures with tailored wave propagation functionalities.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Considerations in upconversion: A practical guide to sum-frequency generation spectrometer design and implementation

Here, in this tutorial review, we discuss how the choice of upconversion pulse shape in broadband vibrational sum-frequency generation (SFG) spectrometer design impacts the chemical or physical insights one can obtain from a set of measurements. A time-domain picture of a vibrational coherence being mapped by a second optical field is described and the implications of how this mapping, or upconversion process, takes place are given in the context of several popular and emerging approaches found in the literature. Emphasis is placed on broadband frequency-domain measurements, where the choice of upconversion pulse enhances or limits the information contained in the SFG spectrum. We conclude with an outline for a flexible approach to SFG upconversion using pulse-shaping methods and a simple guide to design and optimize the associated instrumentation.

47 OTHER INSTRUMENTATION↗

Neutron induced background in the COMPTEL detector on the Gamma Ray Observatory

Interactions of neutrons in a prototype of the Compton imaging telescope (COMPTEL) gamma ray detector for the Gamma Ray Observatory were studied to determine COMPTEL's sensitivity as a neutron telescope and to estimate the gamma ray background resulting from neutron interactions. The IUCF provided a pulsed neutron beam at five different energies between 18 and 120 MeV. These measurements showed that the gamma ray background from neutron interactions is greater than previously expected. It was thought that most such events would be due to interactions in the upper detector modules of COMPTEL and could be distinguished by pulse shape discrimination. Rather, the bulk of the gamma ray background appears to be due to interactions in passive material, primarily aluminum, surrounding the D1 modules. In a considerable fraction of these interactions, two or more gamma rays are produced simultaneously, with one interacting in the D1 module and the other interacting in the module of the lower (D2) detector. If the neutron interacts near the D1 module, the D1 D2 time of flight cannot distinguish such an event from a true gamma ray event. In order to assess the significance of this background, the flux of neutrons in orbit has been estimated based on observed events with neutron pulse shape signature in D1. The strength of this neutron induced background is estimated. This is compared with the rate expected from the isotropic cosmic gamma ray flux.

Morris, D. J.↗

Investigation of ASIC-based signal readout electronics for LEGEND-1000

LEGEND, the Large Enriched Germanium Experiment for Neutrinoless ββ Decay, is a ton-scale experimental program to search for neutrinoless double beta (0νββ) decay in the isotope 76 Ge with an unprecedented sensitivity. Building on the success of the low-background 76 Ge-based GERDA and Majorana Demonstrator experiments, the LEGEND collaboration is targeting a signal discovery sensitivity beyond 10 28 yr on the decay half-life with approximately 10 t∙yr of exposure. Signal readout electronics in close proximity to the detectors plays a major role in maximizing the experiment's discovery sensitivity by reducing electronic noise and improving pulse shape analysis capabilities for the rejection of backgrounds. However, the proximity also poses unique challenges for the radiopurity of the electronics. Application-specific integrated circuit (ASIC) technology allows the implementation of the entire charge sensitive amplifier (CSA) into a single low-mass chip while improving the electronic noise and reducing the power consumption. In this work, we investigated the properties and electronic performance of a commercially available ASIC CSA, the XGLab CUBE preamplifier, together with a p-type point contact high-purity germanium detector. We show that low noise levels and excellent energy resolutions can be obtained with this readout. Moreover, we demonstrate the viability of pulse shape discrimination techniques for reducing background events.

47 OTHER INSTRUMENTATION↗

First demonstration of improved yield with reduced adiabat in inertial confinement fusion implosions on the National Ignition Facility

Laser-driven, indirect-drive inertial confinement fusion (ICF) experiments at the National Ignition Facility (NIF) recently achieved a target gain greater than one, where fusion energy output exceeds input laser energy [Abu-Shawareb et al., Phys. Rev. Lett. 132, 065102 (2024)]. Despite this milestone, gain levels remain insufficient for practical applications such as inertial fusion energy, making performance improvement critical. One promising approach is increasing fuel compression by lowering the implosion adiabat. To explore reduced adiabat, experiments were conducted modifying the laser pulse shape and shock timing of an existing 1.9-MJ-drive implosion design performing near the ignition cliff [Abu-Shawareb et al., Phys. Rev. Lett. 129, 075001 (2022)]. These experiments demonstrated increased compression and fusion yield in ICF implosions at the NIF by using a lower fuel adiabat, and increased compression with a reduced adiabat in high-density carbon ablators. The updated design achieved up to 80% higher fusion yield and 14% greater fuel compression compared to the previous best-performing 1.9-MJ experiment, with repeatable performance, and is the only implosion design to achieve a target gain exceeding one with < 2.04 MJ laser energy. Notably, this work was made possible because of recent advances in target quality and pulse shape control allowing experimental access to the ignition regime, and thereby increased sensitivity to adiabat. This work addresses a long-standing question in ICF research and lays the foundation for higher target gains through optimized implosion strategies. It underscores the potential of reduced adiabat designs to enhance compression and fusion yields for future ICF applications.

Hohenberger, M. [Lawrence Livermore National Labor↗

Thermal Characterization of Tl 2 LiYCl 6 :Ce (TLYC)

Tl 2 LiYCl 6 :Ce (TLYC) is a new dual-detection elpasolite scintillator that can detect and distinguish between gamma rays and neutrons using pulse shape discrimination (PSD). It has a higher density and Z -number than the more mature and well-known elpasolite Cs 2 LiYCl 6 :Ce (CLYC), causing it to have a significantly better gamma-ray stopping power. These properties make TLYC an attractive alternative to CLYC for resource-constrained applications where size and weight are important, such as space or national security applications. Such applications may be subjected to a wide range of temperatures, and therefore, TLYC's performance was characterized for the first time over a temperature range of -20 °C to +50 °C in 10 °C increments. TLYC's thermal response effects on light-output linearity with energy, gamma-ray photopeak energy resolution, detected neutron energy, pulse shapes, and figure of merit (FOM) is analyzed and reported. The light output of TLYC was found to be linear with energy over the tested temperature range and was observed to decrease with increasing temperature. The decay time of the scintillation light output was observed to decrease with decreasing temperature at short times, leading to a decreasing PSD FOM. The gamma-ray photopeak energy resolution was also observed to degrade with decreasing temperature, due to an asymmetric broadening of the photopeak at low temperatures.

36 MATERIALS SCIENCE↗

Development of a High-Rate Front-End ASIC for X-Ray Spectroscopy and Diffraction Applications

We developed a new front-end application-specific integrated circuit (ASIC) to upgrade the Maia X-ray microprobe. The ASIC instruments 32 configurable channels that perform either positive or negative charge amplification, pulse shaping, peak amplitude, and time extraction along with buffered analog storage. At a gain of 3.6 V/fC, 1-μs peaking time, and a temperature of 248 K, an electronic resolution of 13 and 10 e- rms was measured with and without a silicon drift detector (SDD) sensor, respectively. A spectral resolution of 170-eV full-width at half-maximum (FWHM) at 5.9 keV was obtained with an 55Fe source. The channel linearity was better than ± 1% with rate capabilities up to 40 kcps. The ASIC was fabricated in a commercial 250-nm process with a footprint of 6.3 mm × 3.9 mm and dissipates 167 mW of static power.

Vernon, Emerson↗

Design and construction of a new detector to measure ultra-low radioactive-isotope contamination of argon

Large liquid argon detectors offer one of the best avenues for the detection of galactic weakly interacting massive particles (WIMPs) via their scattering on atomic nuclei. The liquid argon target allows exquisite discrimination between nuclear and electron recoil signals via pulse-shape discrimination of the scintillation signals. Atmospheric argon (AAr), however, has a naturally occurring radioactive isotope, 39Ar, a ß emitter of cosmogenic origin. For large detectors, the atmospheric 39Ar activity poses pile-up concerns. The use of argon extracted from underground wells, deprived of 39Ar, is key to the physics potential of these experiments. The DarkSide-20k dark matter search experiment will operate a dual-phase time projection chamber with 50 tonnes of radio-pure underground argon (UAr), that was shown to be depleted of 39Ar with respect to AAr by a factor larger than 1400. Assessing the 39Ar content of the UAr during extraction is crucial for the success of DarkSide-20k, as well as for future experiments of the Global Argon Dark Matter Collaboration (GADMC). This will be carried out by the DArT in ArDM experiment, a small chamber made with extremely radio-pure materials that will be placed at the centre of the ArDM detector, in the Canfranc Underground Laboratory (LSC) in Spain. The ArDM LAr volume acts as an active veto for background radioactivity, mostly ?-rays from the ArDM detector materials and the surrounding rock. This article describes the DArT in ArDM project, including the chamber design and construction, and reviews the background required to achieve the expected performance of the detector.

Noble liquid detectors, Dark Matter detectors, Cry↗

Dynamics of implosion, bounce, and re-implosion of a shell directly driven by a time-shaped laser pulse

Gas-filled plastic spherical shells have been imploded using the 60-beam OMEGA laser. The same laser pulse was used as in a previous experiment, which demonstrated the dynamic formation of a shell by irradiating a homogeneous plastic foam sphere. In the present experiment, the shell initially implodes, bounces, and expands; a new shell then forms and undergoes a second implosion. Analysis of x-ray self-emission-streaked images and sequences of 2D x-ray self-emission framing camera images show shell evolution that is in reasonable agreement with 1D simulations. Shell integrity and symmetry are well maintained until the formation of the new shell. The final implosion, instead, is affected by substantial asymmetries.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Power spectra of quasi-periodic oscillations in luminous X-ray stars

A variety of partial random processes are considered in order to study the effects on the power-density spectrum of several physical phenomena that may occur in the beat-frequency modulated accretion (BFMA) model of QPOs. The relevant physical properties of BFMA model are summarized, and the class of random processes used to represent the X-ray intensity time series predicted by the model are introduced. The dependence of the power-density spectrum on pulse shape is discussed. Pulse-lifetime and orbital-frequency distributions are introduced, illustrating how these affect the power-density spectrum. The effect of nonuniform initial-pulse phase distributions and of nonuniform pulse-time distributions are considered. The effects of a particular type of pulse-to-pulse correlation that may be natural in the context of the BFMA model and that greatly increases the power of the oscillations relative to that in the red noise is analyzed.

Shibazaki, N.↗

Imaging Based Detector with Efficient Scintillators for Neutron Diffraction Measurements

The Anger Camera developed by the detector group at the Oak Ridge National Laboratory was utilized for the present work for its unique advantage of employing multiple modules to obtain large active measurement area for detecting diffracted/scattered thermal neutrons. Considering the relatively small flux associated with diffracted/scattered neutrons, suitable efficiency with high spatial resolution is a requirement for utilizing two-dimensional imaging detectors. The potential to implement pulse shape (in addition to pulse height) discrimination-based scintillators further enhances the ability to detect diffracted neutrons with improved signal to noise ratio. In this paper, initial results associated with 6Li glass-based scintillator will be presented. The authors explored the feasibility of using this system to detect and quantify diffraction peaks and peak shifts at the Neutron Residual Stress Facility (NRSF2), High Flux Isotope Reactor (HFIR) in the Oak Ridge National Laboratory (ORNL). Suitable camera mounting and shielding had to be developed. Reference measurements using polycrystalline powders with known atomic planar spacing will be discussed along with measurement settings associated with expected resolution for peak shift measurements. Initial results are promising and demonstrate that a suitable scintillation-based neutron detecting system is viable for residual stress-based diffraction measurements. Small area detectors are also feasible with suitable consideration to scattering volume and distance to detector.

Seals, Matthew↗

Behavior of soda-lime silicate glass under laser-driven shock compression up to 315 GPa

Shock experiments give a unique insight into the behavior of matter subjected to extremely high pressures and temperatures. Understanding the behavior of materials under such extreme conditions is key to modeling material failure and deformation dynamics under impact. While studies on pure silica are extensive, the shock behavior of other commercial silicates that contain additional oxides has not been systematically investigated. To better understand the role of composition in the dynamic behavior of silicates, we performed laser-driven dynamic compression experiments on soda-lime glass (SLG) up to 315 GPa. Using the accurate pulse shaping offered by the long pulse laser system at the Matter in Extreme Conditions end-station at the Linac Coherent Light Source, SLG was shock compressed along the Hugoniot to multiple pressure-temperature points. Velocity Interferometer System for Any Reflector was used to measure the velocity and determine the pressure inside the SLG. The U s –u p relationship obtained agrees well with the previous parallel plate impact studies. Within the error bars, no transformation to the crystalline phase was observed up to 70 GPa, which is in contrast to the behavior of pure silica under shock compression. Our studies show that the glass composition strongly influences the shock compression behavior of the silicate glasses.

36 MATERIALS SCIENCE↗

Progress Towards Improved Analysis of TES X-ray Data Using Principal Component Analysis

The traditional method of applying a digital optimal filter to measure X-ray pulses from transition-edge sensor (TES) devices does not achieve the best energy resolution when the signals have a highly non-linear response to energy, or the noise is non-stationary during the pulse. We present an implementation of a method to analyze X-ray data from TESs, which is based upon principal component analysis (PCA). Our method separates the X-ray signal pulse into orthogonal components that have the largest variance. We typically recover pulse height, arrival time, differences in pulse shape, and the variation of pulse height with detector temperature. These components can then be combined to form a representation of pulse energy. An added value of this method is that by reporting information on more descriptive parameters (as opposed to a single number representing energy), we generate a much more complete picture of the pulse received. Here we report on progress in developing this technique for future implementation on X-ray telescopes. We used an 55Fe source to characterize Mo/Au TESs. On the same dataset, the PCA method recovers a spectral resolution that is better by a factor of two than achievable with digital optimal filters.

Low-temperature detectors A[center dot] Transition↗

Electron choreography at the attosecond time scale

Abstract In this work, we report on coherent control of electron dynamics in atoms via attosecond pulse-shaping. We show that the photoelectron emission from argon gas produced by absorption of an attosecond pulse train (APT) made of odd and even harmonics can be manipulated along the direction of polarization of the light by tuning the spectral components (amplitude and phase) of the pulse. In addition, we show that APTs produced with a two-color (400- plus 800 nm) femtosecond driving field exhibit high temporal tunability, which is optimized for an intensity ratio between the two colors in the range of 0.1 to 5%.

74 ATOMIC AND MOLECULAR PHYSICS↗

Ultranarrow bandwidth pulses from a regeneratively mode-locked fiber laser

We report on the generation of transform-limited nanosecond pulse with an ultranarrow bandwidth from a regeneratively mode-locked erbium-doped fiber laser. A narrow bandwidth fiber Bragg grating is combined with a bulk amplitude electro-optic modulator to shape pulse evolution inside a ring cavity, and regenerative mode locking is applied to produce a stationary shape of pulses in the nanosecond regime (2.05 ns in duration). Spectral characterization via high bandwidth optoelectronic devices shows that optical pulses have an ultranarrow bandwidth of 220 MHz. Numerical simulation reveals that the shape of the narrow spectral filter has a strong effect on the duration and bandwidth of output pulses.

43 PARTICLE ACCELERATORS↗