Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pulse column”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

BROADBAND SPECTROSCOPY USING TWO SUZAKU OBSERVATIONS OF THE HMXB GX 301-2

We present the analysis of two Suzaku observations of GX 301-2 at two orbital phases after the periastron passage. Variations in the column density of the line-of-sight absorber are observed, consistent with accretion from a clumpy wind. In addition to a cyclotron resonance scattering feature (CRSF), multiple fluorescence emission lines were detected in both observations. The variations in the pulse profiles and the CRSF throughout the pulse phase have a signature of a magnetic dipole field. Using a simple dipole model we calculated the expected magnetic field values for different pulse phases and were able to extract a set of geometrical angles, loosely constraining the dipole geometry in the neutron star. From the variation of the CRSF width and energy, we found a geometrical solution for the dipole, making the inclination consistent with previously published values.

79 ASTRONOMY AND ASTROPHYSICS↗

Soft x-ray properties of the binary millisecond pulsar J0437-4715

We obtained a light curve for the 5.75 ms pulsar J0437-4715 in the 65-120 A range with 0.5 ms time resolution using the Deep Survey instrument on the EUVE satellite. The single-peaked profile has a pulsed fraction of 0. 27 +/- 0.05, similar to the ROSAT data in the overlapping energy band. A combined analysis of the EUVE and ROSAT data is consistent with a power-law spectrum of energy index alpha = 1.2-1.5, intervening column density NH = (5-8) x 10(exp 19)/sq cm, and luminosity 5.0 x 10(exp 30) ergs/s in the 0.1-2. 4 keV band. We also use a bright EUVE/ROSAT source only 4.3 deg from the pulsar, the Seyfert galaxy RX J0437.4-4711 (= EUVE J0437-471 = lES 0435-472), to obtain an independent upper limit on the intervening absorption to the pulsar, NH less than 1.2 x 10(exp 20)/sq cm. Although a blackbody spectrum fails to fit the ROSAT data, two-component spectral fits to the combined EUVE/ROSAT data are used to limit the temperatures and surface areas of thermal emission that might make partial contributions to the flux. A hot polar cap of radius 50-600 m and temperature (1.0-3.3) x 10(exp 6) K could be present. Alternatively, a larger region with T = (4-12) x 10(exp 5) K and area less than 200 sq km, might contribute most of the EUVE and soft X-ray flux, but only if a hotter component were present as well. Any of these temperatures would require some mechanism(s) of surface reheating to be operating in this old pulsar, the most plausible being the impact of accelerated electrons and positrons onto the polar caps. The kinematically corrected spin-down power of PSR J0437-4715 is only 4 x 10(exp 33) ergs/s, which is an order of magnitude less than that of the lowest-luminosity gamma-ray pulsars Geminga and PSR B1055-52. The absence of high-energy gamma-rays from PSR J0437-4715 might signify an inefficient or dead outer gap accelerator, which in turn accounts for the lack of a more luminous reheated surface such as those intermediate-age gamma-ray pulsars may have.

Halpern, Jules P.↗

High-Magnification Faraday Rotation Imaging and Analysis of X-pinch Implosion Dynamics

An X-pinch load driven by an intense current pulse (>100 kA in ~100 ns) can result in the formation of a small radius, runaway compressional micro-pinch. A micro-pinch is characterized by a hot (>1 keV), current-driven (>100 kA), high-density plasma column (near solid density) with a small neck diameter (1–10 μm), a short axial extent (<1 mm), and a short duration (.1 ns). With material pressures often well into the multi-Mbar regime, a micro-pinch plasma often radiates an intense, sub-ns burst of sub-keV to multi-keV x-rays. A low-density coronal plasma immediately surrounding the dense plasma neck could potentially shunt current away from the neck and thus reduce the magnetic drive pressure applied to the neck. To study the current distribution in the coronal plasma throughout the implosion process, a Faraday rotation imaging diagnostic (1064 nm) capable of producing simultaneous high-magnification polarimetric and interferometric images has been developed for the 1-MA, 100-ns MAIZE facility at the University of Michigan. Designed with a variable magnification (1–10&times;), this diagnostic achieves a spatial resolution of approximately 35 μm, which is useful for resolving the ~100-μm-scale coronal plasma region immediately surrounding the dense core. Combined with the corresponding interferogram, which provides the radial density distribution in the low-density coronal plasma, the measured rotation can be used to diagnose the delivery of the driver current, and thus the magnetic drive pressure, to the micro-pinch plasma as it approaches minimal radius. Using this technique on MAIZE, we have measured

Dowhan, G. V.↗

Hydrodynamic modeling of plasma channel systems for laser plasma accelerators

Structured plasma channels are an essential technology for driving high-gradient, plasma-based acceleration and control of electron and positron beams for advanced concepts accelerators. Laser and gas technologies can permit the generation of long plasma columns known as hydrodynamic, optically-field-ionized (HOFI) channels, which feature low on-axis densities and steep walls. By carefully selecting the background gas and laser properties, one can generate narrow, tunable plasma channels for guiding high intensity laser pulses. Here, we present on the development of simulations of HOFI channels using the FLASH code, a publicly available radiation hydrodynamics code. We explore sensitivities of the channel evolution to laser profile, intensity, and background gas conditions, and identify relevant scalings with laser intensity through a range of practical channel delays.

Accelerators↗

Influence of induced axial magnetic field on plasma dynamics and radiative characteristics of Z pinches

The influence of an induced axial magnetic field on plasma dynamics and radiative characteristics of Z pinches is investigated. An axial magnetic field was induced in a novel Z-pinch load: a double planar wire array with skewed wires (DPWAsk), which represents a planar wire array in an open magnetic configuration. The induced axial magnetic field suppressed magneto-Rayleigh-Taylor (MRT) instabilities (with m = 0 and m = 1 instability modes) in the Z-pinch plasma. The influence of the initial axial magnetic field on the structure of the plasma column at stagnation was manifested through the formation of a more uniform plasma column compared to a standard double planar wire array (DPWA) load [V. L. Kantsyrev et al., Phys. Plasmas 15, 030704 (2008)]. The DPWAsk load is characterized by suppression of MRT instabilities and by the formation of the sub-keV radiation pulse that occurs before the main x-ray peak. Gradients in plasma parameters along the cathode-anode gap were observed and analyzed for DPWAsk loads made from low atomic number Z (Al) and mid-Z (brass) wires.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spatio-temporal ablation dynamics and plasma chemistry of aluminum induced by temporally modulated ytterbium fiber laser

Here, in this work, we studied single-pulse ablation dynamics of a temporally modulated continuous wave laser-material interaction with Al using in situ multimodal time-resolved diagnostics that describe in detail the associated physical and chemical processes. Time-resolved scattering, emission imaging, and optical emission spectroscopy unveiled a sequence of events spread out across three distinct phases: (i) early phase ablation process, associated with particle generation and liquid Al column formation (<20 μs), (ii) secondary detonation when sufficient ejected material is accumulated over the surface (20-50 μs), and (iii) molten liquid Al pool oscillation on the surface, followed by large droplet ejection from the liquid pool (100-500 μs). Atomic Al and AlO were observed with optical emission spectroscopy at different ratios during the entire lifetime of the event, verifying the formation of oxidized Al vapor upon its interaction with air. Morphological and compositional characterization confirmed surface oxidation and material re-solidification in the form of protrusions produced during the irradiation process. This work provides insights into the complex physical and chemical mechanisms of single-pulse ablation in the sub-millisecond laser pulse regime, which are critically important for parameter optimization in a variety of laser processing, microfabrication, and deposition applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study of the Many Fluorescent Lines and the Absorption Variability in GX 301-2 with XMM-Newton

We present an in-depth study of the High Mass X-ray Binary (HMXB) GX 301-2 during its pre-periastron flare using data from the XMM-Newton satellite. The energy spectrum shows a power law continuum absorbed by a large equivalent hydrogen column on the order of 10(exp 24)/ sq cm and a prominent Fe K-alpha fluorescent emission line. Besides the Fe K-alpha line, evidence for Fe K-Beta, Ni K-alpha, Ni K-Beta, S K-alpha, Ar K-alpha, Ca K-alpha, and Cr K-alpha fluorescent lines is found. The observed line strengths are consistent with fluorescence in a cold absorber. This is the first time that Cr K-alpha is seen in emission in the X-ray spectrum of a HMXB. In addition to the modulation by the strong pulse period of approx 685 sec the source is highly variable and shows different states of activity. We perform time-resolved as well as pulse-to-pulse resolved spectroscopy to investigate differences between these states of activity. We find that fluorescent line fluxes are strongly variable and generally follow the overall flux. The N-H value is variable by a factor of 2, but not correlated to continuum normalization. We find an interval of low flux in the light curve in which the pulsations cease almost completely, without any indication of an increasing absorption column. We investigate this dip in detail and argue that it is most likely that during the dip the accretion ceased and the afterglow of the fluorescent iron accounted for the main portion of the X-ray flux. A similar dip was found earlier in RXTE data, and we compare our findings to these results.

Fuerst, F.↗

Mind the gap – Part 1: Accurately locating warm marine boundary layer clouds and precipitation using spaceborne radars

Abstract. Ground-based radar observations show that, over the eastern North Atlantic, 50 % of warm marine boundary layer (WMBL) hydrometeors occur below 1.2 km and have reflectivities of <-17 dBZ, thus making their detection from space susceptible to the extent of surface clutter and radar sensitivity. Surface clutter limits the ability of the CloudSat cloud profiling radar (CPR) to observe the true cloud base in ~52 % of the cloudy columns it detects and true virga base in ~80 %, meaning the CloudSat CPR often provides an incomplete view of even the clouds it does detect. Using forward simulations, we determine that a 250 m resolution radar would most accurately capture the boundaries of WMBL clouds and precipitation; that being said, because of sensitivity limitations, such a radar would suffer from cloud cover biases similar to those of the CloudSat CPR. Observations and forward simulations indicate that the CloudSat CPR fails to detect 29 %–43 % of the cloudy columns detected by ground-based sensors. Out of all configurations tested, the 7 dB more sensitive EarthCARE CPR performs best (only missing 9.0 % of cloudy columns) indicating that improving radar sensitivity is more important than decreasing the vertical extent of surface clutter for measuring cloud cover. However, because 50 % of WMBL systems are thinner than 400 m, they tend to be artificially stretched by long sensitive radar pulses, hence the EarthCARE CPR overestimation of cloud top height and hydrometeor fraction. Thus, it is recommended that the next generation of space-borne radars targeting WMBL science should operate interlaced pulse modes including both a highly sensitive long-pulse mode and a less sensitive but clutter-limiting short-pulse mode.

54 ENVIRONMENTAL SCIENCES↗

Airborne Lidar for Simultaneous Measurement of Column CO2 and Water Vapor in the Atmosphere

The 2-micron wavelength region is suitable for atmospheric carbon dioxide (CO2) measurements due to the existence of distinct absorption feathers for the gas at this particular wavelength. For more than 20 years, researchers at NASA Langley Research Center (LaRC) have developed several high-energy and high repetition rate 2-micron pulsed lasers. This paper will provide status and details of an airborne 2-micron triple-pulse integrated path differential absorption (IPDA) lidar. The development of this active optical remote sensing IPDA instrument is targeted for measuring both CO2 and water vapor (H2O) in the atmosphere from an airborne platform. This presentation will focus on the advancement of the 2-micron triple-pulse IPDA lidar development. Updates on the state-of-the-art triple-pulse laser transmitter will be presented including the status of seed laser locking, wavelength control, receiver telescope, detection system and data acquisition. Future plans for the IPDA lidar system for ground integration, testing and flight validation will also be presented.

Singh, Upendra N.↗

Hydrodynamics of Two-Phase Flows through Porous Media in Microgravity: Packed Bed Reactor Experiment onboard of the International Space Station

The objective of the Packed Bed Reactor Experiment was to develop a fundamental understanding of the hydrodynamics of two-phase flow with no phase transition through porous media in microgravity. This work describes two experimental campaigns flown on the International Space Station (ISS) that were designed to achieve the objective. This work presents the results on flow patterns observed, two-phase flow pressure drop in porous media, and the impact of capillary effects on pressure drop at various gas and liquid flow rates. This work is the first to present predictive correlations of the two-phase friction factor for the different regimes identified based on the superficial liquid and gas velocity in microgravity, the first to hypothesize the different regimes based on the change in slope of the pressure gradient versus flow rate plots, the first to address the effects of the capillarity on the pressure gradient and the first to measure column holdup and assess the effective porosity based on the packing and the trapped gas bubbles. Experimental data on pressure drop in gas (N2) – liquid (water) flow show the presence of four different flow regimes in microgravity. Dispersed bubble flow (DB) and pulse (P) flow regimes are detected at high liquid flow rates, whereas at low liquid flow rates “large bubble” or elongated bubble (LB) and “gas channeling” (GC) regimes are observed. For these different flow regimes, different two-phase flow friction factor and pressure gradient correlations are presented for the first time as a function of the gas and liquid modified Reynolds numbers and Suratman number. Within the viscous-capillary (V-C) regime, it is found that the capillary contribution is the dominant force that contributes to the pressure drop for the wetting case (glass). However, for the non-wetting packing (Teflon), the viscous contribution dominates. It was found that the gas hold-up and pressure drop are functions of bed history at low liquid and gas flow rates with the magnitude of the hysteresis decreasing with increasing flow rates. PBRE-2 results show that the capillary force is a strong function of the superficial liquid velocity but is a much weaker function of the superficial gas velocity and varies inversely with the particle diameter. Within the Viscous-Capillary (V-C) regime, over 90% of the pressure gradient is attributed to the capillary contribution in the gas continuous regime. However, in the large bubble regime, the viscous and capillary contributions were comparable. After the completion of PBRE-2 with glass spherical beads, another bed packed with alumina was installed. Pressure gradient data for the alumina packed bed (PBRE-Water Recovery) were transferred to the PI and were not analyzed by the authors of this work. The Packed Bed Reactor Experiment concluded its on-orbit operation after two successful campaigns of testing in 2017 and in 2021. The flight hardware was brought back from orbit and is being reconditioned for a series of future experiments referred to as PBRE-WRS in support of water recovery (WRS). The WRS series consists of testing different two-phase fluid system components and packed beds to assess their pressure gradient characteristics, which will be used for designing packed bed reactors for various applications relevant to life support. Although there is so much relevance of the experimental results obtained from the two PBRE campaign in microgravity to life support, these findings also apply to other applications that involve two phase flow in porous medium such as fuel cells, transport of nutrient to plants in space and other chemical and materials processing that involve two phase flows. These systems operate differently in microgravity because, due to the lack of buoyancy, the density difference between the phases becomes irrelevant and no longer leads to phase separation.

Packed Bed↗

Ground and Airborne Methane Measurements using Optical Parametric Amplifiers

We report on an initial airborne demonstration of atmospheric methane column measurements at 1.65 micrometers using a widely tunable, seeded optical parametric amplifier (OPA) lidar and a photon counting detector. Methane is an important greenhouse gas and accurate knowledge of its sources and sinks is needed for climate modeling. Our lidar system uses 20 pulses at increasing wavelengths and integrated path differential absorption (IPDA) to map a methane line at 1650.9 nanometers. The wavelengths are generated by using a Nd:YAG pump laser at 1064.5 nanometers and distributed feedback diode laser at 1650.9 nanometers and a periodically-poled lithium niobate (PPLN) crystal. The pulse width was 3 nanoseconds and the pulse repetition rate was 6.28 KHz. The outgoing energy was approximately 13 microJoules/pulse. A commercial 20 nanometer diameter fiber-coupled telescope with a photon counting detector operated in analog mode with a 0.8 nanometer bandpass filter was used as the lidar receiver. The lidar system was integrated on NASA's DC-8 flying laboratory, based at Dryden Airborne operations Facility (DAOF) in Palmdale CA. Three flights were performed in the central valley of California. Each flight lasted about 2.5 hours and it consisted of several flight segments at constant altitudes at approximately 3, 4.5, 6, 7.6, 9.1, 10.6 km (l0, 15, 20, 25, 30, 35 kft). An in-situ cavity ring down spectrometer made by Picarro Inc. was flown along with the lidar instrument provided us with the "truth" i.e. the local CH4, CO2 and H2O concentrations at the constant flight altitude segments. Using the aircraft's altitude, GPS, and meteorological data we calculated the theoretical differential optical depth of the methane absorption at increasing altitudes. Our results showed good agreement between the experimentally derived optical depth measurements from the lidar instrument and theoretical calculations as the flight altitude was increased from 3 to 10.6 kilometers, assuming a constant methane mixing ratio of 1.8 parts per million. The in-situ spectrometer did not show any significant deviations from the ambient concentrations. Further analysis using meteorological data from the Global Modeling and Assimilation Office (http://gmao.gsfc.nasa.gov/) to derive the theoretical optical depth also showed good agreement with the experimentally derived values. The OPA lidar system with slight modifications has also been used to measure CO2, water vapor, and CO in the near and mid-infrared spectral regions on the ground.

Riris, Haris↗

Medium-resolution Autonomous in situ Gamma Detection System for Marine and Coastal Waters

We are developing a medium-resolution autonomous in situ gamma detection system for marine and coastal waters. The system is designed to extract and preconcentrate isotopes of interest from natural waters prior to detection in order to eliminate signal attenuation of the gamma rays traveling through water and lower the overall background due to the presence of naturally occurring radioactive isotopes (40K and U/Th series radionuclides). Filtration is used to preconcentrate target isotopes residing on suspended particles, while chemosorption is employed to preferentially extract truly dissolved components from the water column. A variety of commercial and in-house nano-porus chemosorbents have been selected, procured or produced, and tested. Used filter and chemosorbent media are counted autonomously using two LaBr3 detectors in a near 4-pi configuration around the samples. A compact digital pulse processing system developed in-house and capable of running in coincidence mode is used to process the signal from the detectors to a small on-board computer. The entire system is extremely compact (9” dia. x 30” len.) and platform independent, but designed for initial deployment on a research buoy.

Gamma ray spectrometry↗

Improving parameter estimation for column experiments by multi-model evaluation and comparison

Reliability of column experiment data interpretation by fitting the data to a transport model using the nonlinear least squares method is of concern when the complexity of the experiment increases. Misfits often occur and are accepted with the excuse of system complexity. More often, overfits are published and accepted uncritically. The objective of this work was to improve the reliability of column experiment data interpretation to provide insights for future investigation and select estimates for application prediction. We proposed to achieve this goal by evaluating and comparing various estimates that consider the uncertainties in experimental conditions, sensitivities of model parameters, alternative parameterizations and models. Two examples from the literature were selected for the illustration. Sensitivity analysis showed that the experimentally-controlled parameters (water content, flow rate and pulse volume) are much more sensitive than the transport parameters (dispersivity and mass transfer coefficient) in breakthrough curve fitting. Fixing these sensitive parameters may lead to misfit or biased estimate. Estimating sensitive parameters helps diagnose and remediate the misfit. The dispersion coefficient was parameterized as a function of solute molecular diffusion coefficient, medium dispersivity and average pore water velocity to reduce the number of estimated parameters for multiple tracers. Nonlinear least squares statistics were used to evaluate the goodness-of-fit for the multiple estimates obtained using different fitting schemes (e.g., fixing or estimating parameters), parameterizations and models (e.g., equilibrium or nonequilibrium). The F-test and Akaike s Information Criteria were used for the discrimination of statistically reasonable estimates. Our results suggest that sensitivity/uncertainty analysis and model evaluation /discrimination are useful to improve the reliability of column experiment data interpretation.

58 GEOSCIENCES↗

High-Resolution Measurement of Soil Thermal Properties and Moisture Content Using a Novel Heated Fiber Optics Approach

Hydrological parameters are scale dependent. Efficient monitoring techniques capable of measuring hydrological parameters, such as soil moisture content (θ), over a wide range of spatial scales are essential for understanding the complexity of water and energy movement across the landscape. Techniques to measure θ over spatial scales in the range from centimeters to thousands of meters, however, are sorely lacking. Recent improvements in the distributed temperature sensing (DTS) technology supported the development of novel techniques to fill that gap. However, improvements in the accuracy and applicability of DTS techniques are still needed. This study investigates the possibility of improving the accuracy of the fiber optics dual-probe heat-pulse (FO-DPHP) DTS technique by using a new design to maintain the spacing between the FO-DPHP probes and by introducing a novel data interpretation approach. The accuracy of the novel FO-DPHP design was tested at different θ in a sand column experiment. The FO-DPHP measurements obtained using traditional and novel data interpretation approaches were compared against independent measurements from several calibrated soil water content (EC5) sensors. Monte-Carlo analyses were also performed to assess the impact of DTS measurement errors on the accuracy achieved using the data interpretation approaches. The novel design and data interpretation approach allowed for accurate measurements of soil thermal properties and θ without the need to perform a hard-to-achieve soil-specific calibration. Measured θ had mean errors and standard deviations <0.03 and <0.01 m 3 m -3 , respectively, for moisture conditions ranging from dry to near saturation. The standard deviation in the measured heat capacity was <0.01 MJ m -3 K -1 .

42 ENGINEERING↗

Enhanced dielectric nonlinearity in epitaxial Pb{sub 0.92}La{sub 0.08}Zr{sub 0.52}Ti{sub 0.48}O{sub 3} thin films

High quality c-axis oriented epitaxial Pb{sub 0.92}La{sub 0.08}Zr{sub 0.52}Ti{sub 0.48}O{sub 3} films were fabricated using pulsed laser deposition on (001) LaAlO{sub 3} substrates with conductive LaNiO{sub 3} buffers. Besides confirmation of the in-plane and out-of-plane orientations using X-ray diffraction, transmission electron microscopy study has revealed columnar structure across the film thickness with column width around 100 nm. Characterization of ferroelectric properties was carried out in comparison with polycrystalline Pb{sub 0.92}La{sub 0.08}Zr{sub 0.52}Ti{sub 0.48}O{sub 3} films to extract the effect of epitaxial growth. It is found that the ratio between the irreversible Rayleigh parameter and reversible parameter increased up to 0.028 cm/kV at 1 kHz on epitaxial samples, which is more than twice of that on their polycrystalline counterparts. While this ratio decreased to 0.022 cm/kV with increasing frequency to100 kHz, a much less frequency dependence was observed as compared to the polycrystalline case. The epitaxial Pb{sub 0.92}La{sub 0.08}Zr{sub 0.52}Ti{sub 0.48}O{sub 3} films exhibited a higher mobility of domain wall and the higher extrinsic contribution to the dielectric properties, as well as reduced density of defects, indicating that it is promising for tunable and low power consumption devices.

36 MATERIALS SCIENCE↗

ORBITAL-PHASE-RESOLVED SPECTROSCOPY OF THE INTERMEDIATE POLAR FO AQR USING XMM-NEWTON OBSERVATORY DATA

We present the orbital-phase-resolved analysis of an archival FO Aqr observation obtained using the X-ray Multi-Mirror Mission, European Photon Imaging Camera (pn instrument). We investigate the variation of the spin pulse amplitudes over the orbital period in order to account for the effects of orbital motion on spin modulation. The semi-amplitude variations are in phase with the orbital modulation, changing from (38.0 {+-} 1.8)% at the orbital maximum to (13.3 {+-} 3.7)% at the orbital minimum. The spectral parameters also show changes over the orbital period. One of the absorption components increase by a factor of five between the orbital minimum and maximum. We interpret that this absorption arises from the bulge where accretion stream from the secondary impacts the disk. The spectrum extracted from the orbital minima and maxima can be fitted with a warm absorber model yielding values N{sub H} = 2.09{sup +0.98}{sub -1.09} Multiplication-Sign 10{sup 22} and 0.56{sup +0.26}{sub -0.15} Multiplication-Sign 10{sup 22} cm{sup -2}; and log({xi}) = 0.23{sup +0.37}{sub -0.26} and <0.30 erg cm s{sup -1}, respectively, indicating the existence of ionized absorption from the bulge at the impact zone which is spread out on the disk. The absorption due to accretion curtain and/or column which causes the spin modulation can be distinguished from the disk absorption via spectral modeling.

79 ASTRONOMY AND ASTROPHYSICS↗

Lidar investigations of M-zone

The creation of pulse dye lasers tuned to resonant line of meteor produced admixtures of atmospheric constituents has made it possible to begin lidar investigations of the vertical distribution of mesospheric sodium concentration and its dynamics in the upper atmosphere. The observed morning increase of sodium concentration in the vertical column is probably caused by diurnal variations of sporadic meteors. The study of the dynamics of the sodium column concentration in the period of meteor streams activity confirms the suggestion of cosmic origin of these atoms. The short lived increase of sodium concentration brought about by a meteor stream, however, exceeds by one order the level of the sporadic background.

Ovezgeldiyev, O. G.↗

Time-resolved absorption spectroscopic characterization of ultrafast laser-produced plasmas under varying background pressures

Time-resolved tunable laser absorption spectroscopy is used to characterize the physical properties of ultrafast laser-produced plasmas. The plasmas were produced from an Inconel target, with = 0.4 wt. % Al, using ~ 35 fs, ~800 nm laser pulses at varying Ar background pressures from 1-100 Torr. The absorption spectrum of atomic Al is measured with high spectral and temporal resolution when the probe laser is stepped across the selected Al transition at 394.4 nm. Spectral fitting is used to infer linewidths, kinetic temperature, Al column density, and pressure broadening coefficient. The late time physical properties of plasmas are compared for various pressure levels. Our studies highlight that a significant lower state population exists even at early times of ultrafast laser-produced plasma evolution and lower state population persistence decreases with increasing ambient pressure. We also show that the fundamental optical properties, such as pressure-broadening, can be measured using ultrafast laser-produced plasmas combined with laser absorption spectroscopy.

laser absorption spectroscopy, laser produced plas↗