Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “protein labeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Species-specific ribosomal RNA-FISH identifies interspecies cellular-material exchange, active-cell population dynamics and cellular localization of translation machinery in clostridial cultures and co-cultures

ABSTRACT The development of synthetic microbial consortia in recent years has revealed that complex interspecies interactions, notably the exchange of cytoplasmic material, exist even among organisms that originate from different ecological niches. Although morphogenetic characteristics, viable RNA and protein dyes, and fluorescent reporter proteins have played an essential role in exploring such interactions, we hypothesized that ribosomal RNA-fluorescence in situ hybridization (rRNA-FISH) could be adapted and applied to further investigate interactions in synthetic or semisynthetic consortia. Despite its maturity, several challenges exist in using rRNA-FISH as a tool to quantify individual species population dynamics and interspecies interactions using high-throughput instrumentation such as flow cytometry. In this work, we resolve such challenges and apply rRNA-FISH to double and triple co-cultures of Clostridium acetobutylicum, Clostridium ljungdahlii, and Clostridium kluyveri . In pursuing our goal to capture each organism’s population dynamics, we demonstrate dynamic rRNA, and thus ribosome, exchange between the three species leading to the formation of hybrid cells. We also characterize the localization patterns of the translation machinery in the three species, identifying distinct, dynamic localization patterns among them. Our data also support the use of rRNA-FISH to assess the culture’s health and expansion potential, and, here again, our data find surprising differences among the three species examined. Taken together, our study argues for rRNA-FISH as a valuable and accessible tool for quantitative exploration of interspecies interactions, especially in organisms which cannot be genetically engineered or in consortia where selective pressures to maintain recombinant species cannot be used. IMPORTANCE Though dyes and fluorescent reporter proteins have played an essential role in identifying microbial species in co-cultures, we hypothesized that ribosomal RNA-fluorescence in situ hybridization (rRNA-FISH) could be adapted and applied to quantitatively probe complex interactions between organisms in synthetic consortia. Despite its maturity, several challenges existed before rRNA-FISH could be used to study Clostridium co-cultures of interest. First, species-specific probes for Clostridium acetobutylicum and Clostridium ljungdahlii had not been developed. Second, “state-of-the-art” labeling protocols were tedious and often resulted in sample loss. Third, it was unclear if FISH was compatible with existing fluorescent reporter proteins. We resolved these key challenges and applied the technique to co-cultures of C. acetobutylicum , C. ljungdahlii , and Clostridium kluyveri . We demonstrate that rRNA-FISH is capable of identifying rRNA/ribosome exchange between the three organisms and characterized rRNA localization patterns in each. In combination with flow cytometry, rRNA-FISH can capture sub-population dynamics in co-cultures.

Hill, John D.↗

Spatial Glycomics and Kidney Disease

Glycans are critical for the kidney's physiological and pathological cellular functions, and our ability to reveal their spatial distributions within tissues has helped us reveal how these carbohydrate moieties are involved in many of these processes. This review discusses the role of different types of glycans in kidney biology and disease, common approaches used for glycan imaging, and how glycan imaging has helped us better understand kidney pathology. Here, we mainly focus on emerging methods using mass spectrometry imaging (MSI) because this technology is untargeted and provides complete information on glycan composition compared to the other methods, such as lectin and metabolite labeling, which are targeted and often inform only on the specific part of a glycan structure. We especially focus on protein N-glycosylation, as this is one of the most common post-translational modifications, and these moieties play a vital role in renal structure and function. The recent advancements in MSI of N-glycans we reviewed have provided new insights into the pathophysiology of the kidney and paved the way for clinical application.

60 APPLIED LIFE SCIENCES↗

Phosphate binding protein as the biorecognition element in a biosensor for phosphate

This work explores the potential use of a member of the periplasmic family of binding proteins, the phosphate binding protein (PBP), as the biorecognition element in a sensing scheme for the detection of inorganic phosphate (Pi). The selectivity of this protein originates from its natural role which, in Escherichia coli, is to serve as the initial receptor for the highly specific translocation of Pi to the cytoplasm. The single polypeptide chain of PBP is folded into two similar domains connected by three short peptide linkages that serve as a hinge. The Pi binding site is located deep within the cleft between the two domains. In the presence of the ligand, the two globular domains engulf the former in a hinge-like manner. The resultant conformational change constitutes the basis of the sensor development. A mutant of PBP (MPBP), where an alanine was replaced by a cysteine residue, was prepared by site-directed mutagenesis using the polymerase chain reaction (PCR). The mutant was expressed, from plasmid pSD501, in the periplasmic space of E. coli and purified in a single chromatographic step on a perfusion anion-exchange column. Site-specific labeling was achieved by attaching the fluorophore, N-[2-(1-maleimidyl)ethyl]-7-(diethylamino)coumarin-3-carboxamide (MDCC), to the protein through the sulfhydryl group of the cysteine moiety. Steady-state fluorescence studies of the MPBP-MDCC conjugate showed a change in the intensity of the signal upon addition of Pi. Calibration curves for Pi were constructed by relating the intensity of the fluorescence signal with the amount of analyte present in the sample. The sensing system was first developed and optimized on a spectrofluorometer using ml volumes of sample. It was then adapted to be used on a microtiter plate arrangement with microliter sample volumes. The system's versatility was finally proven by developing a fiber optic fluorescence-based sensor for monitoring Pi. In all three cases the detection limits for the analyte were in the sub-microMolar range. It was also demonstrated that the sensing system was selective for phosphate over other structurally-similar anions, paving the way for the design and development of a new family of biosensors utilizing the specific binding properties of periplasmic proteins. c2003 Elsevier B.V. All rights reserved.

NASA Program Fundamental Space Biology↗

Early events of polyoma infection: adsorption, penetration and nuclear transport

Polyoma virions have different attachment proteins which are responsible for hemagglutination of erythrocytes and attachment to cultured mouse kidney cells (MKC). Virion binding studies demonstrated that MKC possess specific (productive infection) and nonspecific (nonproductive) receptors. Empty polyoma capsids have hemagglutination activity and bind to non-specific MKC receptors, but they are not capable of competing for specific virion cell receptors or preventing productive infection. Isoelectric focusing of the virion major capsid protein, VP1, separated this protein into six species (A through F). These species had identical amino acid sequences, but differed in degree of modification (phosphorylation, acetylation, sulfation and hydroxylation). Evidence based upon precipitation with specific antisera supports the view that VP1 species E is required for specific adsorption and that D and F are required for hemagglutination. The virion attachment domain has been localized to an 18 kilodalton fragment of the C-terminal region of VP1. Monopinocytotic vesicles containing 125I-labeled polyoma virions were isolated from infected MKC. A crosslinker was used to bind the MKC cell receptor(s) covalently to VP1 attachment protein, and a new 120 kilodalton band was identified by SDS-PAGE. An anti-idiotype antibody prepared against a neutralizing polyoma monoclonal antiody was used to identify a putative 50 kilodalton receptor protein from a detergent extract of MKC, as well as from MKC membrane preparation.

NASA Discipline Developmental Biology↗

Labels as a feature: Network homophily for systematically annotating human GPCR drug-target interactions

Machine learning has revolutionized drug discovery by enabling the exploration of vast, uncharted chemical spaces essential for discovering novel patentable drugs. Despite the critical role of human G protein-coupled receptors in FDA-approved drugs, exhaustive in-distribution drug-target interaction testing across all pairs of human G protein-coupled receptors and known drugs is rare due to significant economic and technical challenges. This often leaves off-target effects unexplored, which poses a considerable risk to drug safety. In contrast to the traditional focus on out-of-distribution exploration (drug discovery), we introduce a neighborhood-to-prediction model termed Chemical Space Neural Networks that leverages network homophily and training-free graph neural networks with labels as features. We show that Chemical Space Neural Networks’ ability to make accurate predictions strongly correlates with network homophily. Thus, labels as features strongly increase a machine learning model’s capacity to enhance in-distribution prediction accuracy, which we show by integrating labeled data during inference. We validate these advancements in a high-throughput yeast biosensing system (3773 drug-target interactions, 539 compounds, 7 human G protein-coupled receptors) to discover novel drug-target interactions for FDA-approved drugs and to expand the general understanding of how to build reliable predictors to guide experimental verification.

Hansson, Frederik G↗

Fluorescent Approaches to High Throughput Crystallography

X-ray crystallography remains the primary method for determining the structure of macromolecules. The first requirement is to have crystals, and obtaining them is often the rate-limiting step. The numbers of crystallization trials that are set up for any one protein for structural genomics, and the rate at which they are being set up, now overwhelm the ability for strictly human analysis of the results. Automated analysis methods are now being implemented with varying degrees of success, but these typically cannot reliably extract intermediate results. By covalently modifying a subpopulation, 51%, of a macromolecule solution with a fluorescent probe, the labeled material will add to a growing crystal as a microheterogeneous growth unit. Labeling procedures can be readily incorporated into the final stages of purification. The covalently attached probe will concentrate in the crystal relative to the solution, and under fluorescent illumination the crystals show up as bright objects against a dark background. As crystalline packing is more dense than amorphous precipitate, the fluorescence intensity can be used as a guide in distinguishing different types of precipitated phases, even in the absence of obvious crystalline features, widening the available potential lead conditions in the absence of clear hits. Non-protein structures, such as salt crystals, will not incorporate the probe and will not show up under fluorescent illumination. Also, brightly fluorescent crystals are readily found against less fluorescent precipitated phases, which under white light illumination may serve to obscure the crystals. Automated image analysis to find crystals should be greatly facilitated, without having to first define crystallization drop boundaries and by having the protein or protein structures all that show up. The trace fluorescently labeled crystals will also emit with sufficient intensity to aid in the automation of crystal alignment using relatively low cost optics, further increasing throughput at synchrotrons. This presentation will focus on the methodology for fluorescent labeling, the crystallization results, and the effects of the trace labeling on the crystal quality.

Pusey, Marc L.↗

Assessment of TMT Labeling Efficiency in Large-Scale Quantitative Proteomics: The Critical Effect of Sample pH

Isobaric labeling via tandem mass tag (TMT) reagents enables sample multiplexing prior to LC–MS/MS, facilitating high-throughput large-scale quantitative proteomics. Consistent and efficient labeling reactions are essential to achieve robust quantification; therefore, embedded in our clinical proteomic protocol is a quality control (QC) sample that contains a small aliquot from each sample within a TMT set, referred to as “Mixing QC.” This Mixing QC enables the detection of TMT labeling issues by LC–MS/MS before combining the full samples to allow for salvaging of poor TMT labeling reactions. While TMT labeling is a valuable tool, factors leading to poor reactions are not fully studied. We observed that relabeling does not necessarily rescue TMT reactions and that peptide samples sometimes remained acidic after resuspending in 50 mM HEPES buffer (pH 8.5), which coincided with low labeling efficiency (LE) and relatively low median reporter ion intensities (MRIIs). To obtain a more resilient TMT labeling procedure, we investigated LE, reporter ion missingness, the ratio of mean TMT set MRII to individual channel MRII, and the distribution of log 2 reporter ion ratios of Mixing QC samples. We discovered that sample pH is a critical factor in LE, and increasing the buffer concentration in poorly labeled samples before relabeling resulted in the successful rescue of TMT labeling reactions. Moreover, resuspending peptides in 500 mM HEPES buffer for TMT labeling resulted in consistently higher LE and lower missing data. By better controlling the sample pH for labeling and implementing multiple methods for assessing labeling quality before combining samples, we demonstrate that robust TMT labeling for large-scale quantitative studies is achievable.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An Improved Boosting to Amplify Signal with Isobaric Labeling (iBASIL) Strategy for Precise Quantitative Single-cell Proteomics

Mass spectrometry (MS)-based proteomics has great potential for overcoming the limitations of antibody-based immunoassays for antibody-independent, comprehensive, and quantitative proteomic analysis of single cells. Indeed, recent advances in nanoscale sample preparation have enabled effective processing of single cells. In particular, the concept of using boosting/carrier channels in isobaric labeling to increase the sensitivity in MS detection has also been increasingly used for quantitative proteomic analysis of small-sized samples including single cells. However, the full potential of such boosting/carrier approaches has not been significantly explored, nor has the resulting quantitation quality been carefully evaluated. Herein, we have further evaluated and optimized our recent boosting to amplify signal with isobaric labeling (BASIL) approach, originally developed for quantifying phosphorylation in small number of cells, for highly effective analysis of proteins in single cells. This improved BASIL (iBASIL) approach enables reliable quantitative single-cell proteomics analysis with greater proteome coverage by carefully controlling the boosting-to-sample ratio (e.g. in general <100×) and optimizing MS automatic gain control (AGC) and ion injection time settings in MS/MS analysis (e.g. 5E5 and 300 ms, respectively, which is significantly higher than that used in typical bulk analysis). By coupling with a nanodroplet-based single cell preparation (nanoPOTS) platform, iBASIL enabled identification of ~2500 proteins and precise quantification of ~1500 proteins in the analysis of 104 FACS-isolated single cells, with the resulting protein profiles robustly clustering the cells from three different acute myeloid leukemia cell lines. This study highlights the importance of carefully evaluating and optimizing the boosting ratios and MS data acquisition conditions for achieving robust, comprehensive proteomic analysis of single cells.

59 BASIC BIOLOGICAL SCIENCES↗

A predictive theoretical model for electron tunneling pathways in proteins

A practical method is presented for calculating the dependence of electron transfer rates on details of the protein medium intervening between donor and acceptor. The method takes proper account of the relative energetics and mutual interactions of the donor, acceptor, and peptide groups. It also provides a quantitative search scheme for determining the important tunneling pathways (specific sequences of localized bonding and antibonding orbitals of the protein which dominate the donor-acceptor electronic coupling) in native and tailored proteins, a tool for designing new proteins with prescribed electron transfer rates, and a consistent description of observed electron transfer rates in existing redox labeled metalloproteins and small molecule model compounds.

Onuchic, Jose Nelson↗

Fluorescent Approaches to High Throughput Crystallography

X-ray crystallography remains the primary method for determining the structure of macromolecules. The first requirement is to have crystals, and obtaining them is often the rate-limiting step. The numbers of crystallization trials that are set up for any one protein for structural genomics, and the rate at which they are being set up, now overwhelm the ability for strictly human analysis of the results. Automated analysis methods are now being implemented with varying degrees of success, but these typically cannot reliably extract intermediate results. By covalently modifying a subpopulation, less than or = 1 %, of a macromolecule solution with a fluorescent probe, the labeled material will add to a growing crystal as a microheterogeneous growth unit. Labeling procedures can be readily incorporated into the final stages of purification. The covalently attached probe will concentrate in the crystal relative to the solution, and under fluorescent illumination the crystals show up as bright objects against a dark background. As crystalline packing is more dense than amorphous precipitate, the fluorescence intensity can be used as a guide in distinguishing different types of precipitated phases, even in the absence of obvious crystalline features, widening the available potential lead conditions in the absence of clear "hits." Non-protein structures, such as salt crystals, will not incorporate the probe and will not show up under fluorescent illumination. Also, brightly fluorescent crystals are readily found against less fluorescent precipitated phases, which under white light illumination may serve to obscure the crystals. Automated image analysis to find crystals should be greatly facilitated, without having to first define crystallization drop boundaries and by having the protein or protein structures all that show up. The trace fluorescently labeled crystals will also emit with sufficient intensity to aid in the automation of crystal alignment using relatively low cost optics, further increasing throughput at synchrotrons. Preliminary experiments show that the presence of the fluorescent probe does not affect the nucleation process or the quality of the X-ray data obtained.

Pusey, Marc L.↗

Fluorescence Studies of Lysozyme Nucleation

Fluorescence is one of the most powerful tools available for the study of macromolecules. For example, fluorescence can be used to study self association through methods such as anisotropy (the rotational rate of the molecule in solution), quenching (the accessibility of a bound probe to the bulk solution), and resonance energy transfer (measurement of the distance between two species). Fluorescence can also be used to study the local environment of the probe molecules, and the changes in that environment which accompany crystal nucleation and growth. However fluorescent techniques have been very much underutilized in macromolecular growth studies. One major advantage is that the fluorescent species generally must be at low concentration, typically ca 10-5 to 10-6 M. Thus one can study a very wide range of solution conditions, ranging from very high to very low protein concentration, he latter of which are not readily accessible to scattering techniques. We have prepared a number of fluorescent derivatives of chicken egg white lysozyme (CEWL). Fluorescent probes have been attached to two different sites, ASP 101 and the N-terrninal amine, with a sought for use in different lines of study. Preliminary resonance energy transfer studies have been -carried out using pyrene acetic acid (Ex 340 mn, Em 376 nm) lysozyme as a donor and cascade blue (Ex 377 run, Em 423 nm) labeled lysozyme as an acceptor. The emission of both the pyrene and cascade blue probes was followed as a function of the salt protein concentrations. The data show an increase in cascade blue and a concomitant decrease in the pyrene fluorescence as either the salt or protein concentrations are increased, suggesting that the two species are approaching each other close enough for resonance energy transfer to occur. This data can be analyzed to measure the distance between the probe molecules and, knowing their locations on the protein molecule their distances from and orientations with respect to each other. The results of these and other studies will be discussed.

Pusey, Marc L.↗

Fluorescent Approaches to High Throughput Crystallography

X-ray crystallography remains the primary method for determining the structure of macromolecules. The first requirement is to have crystals, and obtaining them is often the rate-limiting step. The numbers of crystallization trials that are set up for any one protein for structural genomics, and the rate at which they are being set up, now overwhelm the ability for strictly human analysis of the results. Automated analysis methods are now being implemented with varying degrees of success, but these typically can not reliably extract intermediate results. By covalently modifying a subpopulation, less than or = 1%, of a macromolecule solution with a fluorescent probe, the labeled material will add to a growing crystal as a microheterogeneous growth unit. Labeling procedures can be readily incorporated into the final stages of purification. The covalently attached probe will concentrate in the crystal relative to the solution, and under fluorescent illumination the crystals show up as bright objects against a dark background. As crystalline packing is more dense than amorphous precipitate, the fluorescence intensity can be used as a guide in distinguishing different types of precipitated phases, even in the absence of obvious crystalline features, widening the available potential lead conditions in the absence of clear "hits." Non-protein structures, such as salt crystals, will not incorporate the probe and will not show up under fluorescent illumination. Also, brightly fluorescent crystals are readily found against less fluorescent precipitated phases, which under white light illumination may serve to obscure the crystals. Automated image analysis to find crystals should be greatly facilitated, without having to first define crystallization drop boundaries and by having the protein or protein structures all that show up. The trace fluorescently labeled crystals will also emit with sufficient intensity to aid in the automation of crystal alignment using relatively low cost optics, further increasing throughput at synchrotrons. This presentation will focus on the methodology for fluorescent labeling, the crystallization results, and the effects of the trace labeling on the crystal quality.

Pusey, Marc L.↗

Fluorescent Approaches to High Throughput Crystallography

X-ray crystallography remains the primary method for determining the structure of macromolecules. The first requirement is to have crystals, and obtaining them is often the rate-limiting step. The numbers of crystallization trials that are set up for any one protein for structural genomics, and the rate at which they are being set up, now overwhelm the ability for strictly human analysis of the results. Automated analysis methods are now being implemented with varying degrees of success, but these typically cannot reliably extract intermediate results. By covalently modifying a subpopulation, less than or = 1%, of a macromolecule solution with a fluorescent probe, the labeled material will add to a growing crystal as a microheterogeneous growth unit. Labeling procedures can be readily incorporated into the final stages of a macromolecules purification. The covalently attached probe will concentrate in the crystal relative to the solution, and under fluorescent illumination the crystals will show up as bright objects against a dark background. As crystalline packing is more dense than amorphous precipitate, the fluorescence intensity can be used as a guide in distinguishing different types of precipitated phases, even in the absence of obvious crystalline features, widening the available potential lead conditions in the absence of clear "bits." Non-protein structures, such as salt crystals, will not incorporate the probe and will not show up under fluorescent illumination. Also, brightly fluorescent crystals are readily found against less fluorescent precipitated phases, which under white light illumination may serve to obscure the crystals. Automated image analysis to find crystals should be greatly facilitated, without having to first define crystallization drop boundaries and by having the protein or protein structures all that show up. The trace fluorescently labeled crystals will also emit with sufficient intensity to aid in the automation of crystal alignment using relatively low cost optics, further increasing throughput at synchrotrons. This presentation will focus on the methodology for fluorescent labeling, the crystallization results, and the effects of the trace labeling on the crystal quality.

Minamitani, Elizabeth Forsythe↗

Structural characterization of an intrinsically disordered protein complex using integrated small-angle neutron scattering and computing

Characterizing structural ensembles of intrinsically disordered proteins (IDPs) and intrinsically disordered regions (IDRs) of proteins is essential for studying structure–function relationships. Due to the different neutron scattering lengths of hydrogen and deuterium, selective labeling and contrast matching in small-angle neutron scattering (SANS) becomes an effective tool to study dynamic structures of disordered systems. However, experimental timescales typically capture measurements averaged over multiple conformations, leaving complex SANS data for disentanglement. We hereby demonstrate an integrated method to elucidate the structural ensemble of a complex formed by two IDRs. We use data from both full contrast and contrast matching with residue-specific deuterium labeling SANS experiments, microsecond all-atom molecular dynamics (MD) simulations with four molecular mechanics force fields, and an autoencoder-based deep learning (DL) algorithm. From our combined approach, we show that selective deuteration provides additional information that helps characterize structural ensembles. We find that among the four force fields, a99SB-disp and CHARMM36m show the strongest agreement with SANS and NMR experiments. In addition, our DL algorithm not only complements conventional structural analysis methods but also successfully differentiates NMR and MD structures which are indistinguishable on the free energy surface. Finally, we present an ensemble that describes experimental SANS and NMR data better than MD ensembles generated by one single force field and reveal three clusters of distinct conformations. Our results demonstrate a new integrated approach for characterizing structural ensembles of IDPs.

59 BASIC BIOLOGICAL SCIENCES↗

13 C ENDOR Characterization of the Central Carbon within the Nitrogenase Catalytic Cofactor Indicates That the CFe 6 Core Is a Stabilizing “Heart of Steel”

Substrates and inhibitors of Mo-dependent nitrogenase bind and react at Fe ions of the active-site FeMo-cofactor [7Fe–9S–C–Mo–homocitrate] contained within the MoFe protein α-subunit. The cofactor contains a CFe 6 core, a carbon centered within a trigonal prism of six Fe, whose role in catalysis is unknown. Targeted 13 C labeling of the carbon enables electron-nuclear double resonance (ENDOR) spectroscopy to sensitively monitor the electronic properties of the Fe–C bonds and the spin-coupling scheme adopted by the FeMo-cofactor metal ions. Here this report compares 13 CFe 6 ENDOR measurements for (i) the wild-type protein resting state (E 0 ; α-Val 70 ) to those of (ii) α-Ile 70 , (iii) α-Ala 70 -substituted proteins; (iv) crystallographically characterized CO-inhibited “hi-CO” state; (v) E 4 (4H) Janus intermediate, activated for N 2 binding/reduction by accumulation of 4[ e– /H + ]; (vi) E 4 (2H)* state containing a doubly reduced FeMo-cofactor without Fe-bound substrates; and (vii) propargyl alcohol reduction intermediate having allyl alcohol bound as a ferracycle to FeMo-cofactor Fe6. All states examined, both S = 1/2 and 3/2 exhibited near-zero 13 C isotropic hyperfine coupling constants, $^Ca$ = [-1.3 ↔ +2.7] MHz. Density functional theory computations and natural bond orbital analysis of the Fe-C bonds show that this occurs because a (3 spin-up/3 spin-down) spin-exchange configuration of CFe 6 Fe-ion spins produces cancellation of large spin-transfers to carbon in each Fe–C bond. Previous X-ray diffraction and DFT both indicate that trigonal-prismatic geometry around carbon is maintained with high precision in all these states. The persistent structure and Fe–C bonding of the CFe 6 core indicate that it does not provide a functionally dynamic (hemilabile) “beating heart”-instead it acts as “a heart of steel”, stabilizing the structure of the FeMo-cofactor-active site during nitrogenase catalysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ion permeation in potassium ion channels

The study of ion channels dates back to the 1950s and the groundbreaking electrophysiology work of Hodgin and Huxley, who used giant squid axons to probe how action potentials in neurons were initiated and propagated. More recently, several experiments using different structural biology techniques and approaches have been conducted to try to understand how potassium ions permeate through the selectivity filter of potassium ion channels. Two mechanisms of permeation have been proposed, and each of the two mechanisms is supported by different experiments. The key structural biology experiments conducted so far to try to understand how ion permeation takes place in potassium ion channels are reviewed and discussed. Protein crystallo­graphy has made, and continues to make, key contributions in this field, often through the use of anomalous scattering. Other structural biology techniques used to study the contents of the selectivity filter include solid-state nuclear magnetic resonance and two-dimensional infrared spectroscopy, both of which make clever use of isotopic labeling techniques, while molecular-dynamics simulations of ion flow through the selectivity filter have been enabled by the growing number of potassium ion channel structures deposited in the Protein Data Bank.

59 BASIC BIOLOGICAL SCIENCES↗

Three-dimensional feature matching improves coverage for single-cell proteomics based on ion mobility filtering

Single-cell proteomics (scProteomics) promises to advance our understanding of cell functions within complex biological systems. However, a major challenge of current methods is their inability to identify and provide accurate quantitative information for low abundance proteins. Herein, we describe an ion mobility-enhanced mass spectrometry acquisition and peptide identification method, TIFF (Transferring Identification based on FAIMS Filtering), to improve the sensitivity and accuracy of label-free scProteomics. TIFF extends the ion accumulation times for peptide ions by filtering out singly charged ions. The peptide identities are assigned by a three-dimensional MS1 feature matching approach (retention time, accurate mass, and FAIMS compensation voltage). TIFF method enabled unbiased proteome analysis to a depth of >1,700 proteins in single HeLa cells with >1,100 proteins consistently identified. As a demonstration, we applied the TIFF method to obtain temporal proteome profiles of >150 single murine macrophage cells during lipopolysaccharide stimulation and identified time-dependent proteome changes.

59 BASIC BIOLOGICAL SCIENCES↗