Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “protection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Method of protecting a surface with a silicon-slurry/aluminide coating

A low cost coating for protecting metallic base system substrates from high temperatures, high gas velocity oxidation, thermal fatigue and hot corrosion is described. The coating is particularly useful for protecting vanes and blades in aircraft and land based gas turbine engines. A lacquer slurry comprising cellulose nitrate containing high purity silicon powder is sprayed onto the superalloy substrates. The silicon layer is then aluminized to complete the coating. The Si-Al coating is less costly to produce than advanced aluminides and protects the substrate from oxidation and thermal fatigue for a much longer period of time than the conventional aluminide coatings. While more expensive Pt-Al coatings and physical vapor deposited MCrAlY coatings may last longer or provide equal protection on certain substrates, the Si-Al coating exceeded the performance of both types of coatings on certain superalloys in high gas velocity oxidation and thermal fatigue. Also, the Si-Al coating increased the resistance of certain superalloys to hot corrosion.

Deadmore, D. L.↗

Lightning Protection for Composite Aircraft Structures

Lightning protection system consisting of two layers of aluminum foil separated by layer of dielectric material protects graphite/epoxy composite structures on aircraft. Protective layer is secondarily applied lightning protection system, prime advantage of which is nullification of thermal and right angle effect of lightning arc attachment to graphite/epoxy laminate.

Olson, G. O.↗

DC wiring system grounding and ground fault protection issues for central station photovoltaic power plants

The DC wiring system for a photovoltaic power plant presents a number of unique challenges to be overcome by the plant designers. There are a number of different configurations that the grounding of the DC wiring system can take, and the choice will affect the number and type of protective devices required to ensure safety of personnel and protection of equipment. The major grounding and fault protection considerations that must be taken into account when selecting the basic overall circuit configuration are summarized. The inherent advantages and disadvantages of each type of circuit grounding (resistance or solid) along with the personnel safety and equipment protection issues for each of these grounding methods are presented.

Simburger, E. J.↗

An AOTV aeroheating and thermal protection study

The aerothermodynamics and thermal protection of aerobraking orbital transfer vehicles are studied with a view toward design methodology and technology requirements. A particular class of geometries is investigated: the ellipsoidally blunted raked-off elliptic cone. Discussed are the influence of various geometrical parameters on the trajectory and the heat flux as well as heating prediction methods ranging from an engineering correlation formula to computational solutions of the Navier-Stokes equations. Finite-rate catalytic thermal protection materials and gas radiation are considered. Estimates of the specific mass of possible thermal protection systems indicate that support structure is a large contributor to the aerobrake mass as compared with the thermal protection insulation itself. Sizing curves are included which enable the designer to estimate the size aerobrake required from heating considerations for different mass vehicles having aerobrakes of several specific masses.

Scott, C. D.↗

Parametric analysis: SOC meteoroid and debris protection

The meteoroid and man made space debris environments of an Earth orbital manned space operations center are discussed. Protective shielding thickness and design configurations for providing given levels of no penetration probability were also calculated. Meteoroid/debris protection consists of a radiator/shield thickness, which is actually an outer skin, separated from the pressure wall, thickness by a distance. An ideal shield thickness, will, upon impact with a particle, cause both the particle and shield to vaporize, allowing a minimum amount of debris to impact the pressure wall itself. A shield which is too thick will crater on the outside, and release small particles of shield from the inside causing damage to the pressure wall. Inversely, if the shield is too thin, it will afford no protection, and the backup must provide all necessary protection. It was concluded that a double wall concept is most effective.

Kowalski, R.↗

Space shuttle SRB TPS protective paint test and evaluation in NASA Hot Gas Facility and AEDC Tunnel C

The results and outcome of thermal tests conducted to evaluate the performance of the protective coat of paint on the solid rocket booster (SRB) thermal protection system are discussed. A problem was uncovered during a series of tests on the SRB instrumentation islands in AEDC Tunnel C on 13 January 1979. The white protective paint or the Turco coating on the thermal protection system panels began to flow soon after the panels were exposed to the flow. This presented a serious problem especially since the critical pressure sensing, parachute opening baroswitches located on the frustum of the SRB were most likely to be contaminated by the paint flowing down the sides of the SRB nose cone. Because the first two flight articles were already completed, it was necessary to find a solution to the existing paint problem. It was found that all the coatings tested, except the Hypalon, had similar undesirable flow characteristics. Also even the Hypalon, which did not flow, would bubble up and disintegrate when it was applied on top of the new Turco. Recently, the Turco coating was removed from an MSA-:11 panel by dissolving the paint with a certain agent. This was done in two ways, by dissolving and removing almost all of the paint on one side of the panel and dissolving and removing about 50% of the paint on the other. The panel was then coated with Hypalon and tested as before in the Hot Gas Facility. No evidence of any paint flow nor any adverse performance of MSA was observed.

Karu, Z. S.↗

Protective coatings for atomic oxygen susceptible spacecraft materials - STS-41G results

Sixteen materials consisting of metallizations, silicones, and FEP Teflon were applied as protective coatings to selected spacecraft material surfaces and exposed on STS-41G to the LEO atomic oxygen environment. Evaluations of their protective effectiveness were made through assessing their mass loss/gain characteristics, maintenance of base material optical properties, and imperviousness to atomic oxygen attack. Generally, all coatings provided some degree of protection for the underlying material. In some cases the overcoat appeared to be too thin thereby providing inadequate protection.

Whitaker, A. F.↗

Subsystem testing of Galileo's attitude and articulation control fault protection

This paper discusses the fault protection tesing of the Attitude and Articulation Control Subsystem (AACS) of the Galileo spacecraft. The need for an autonomous fault protection system on an interplanetary spacecraft is discussed. Galileo requirements for the detection and response of specific hardware failures is discussed along with the fault protection software design and implementation. The test beds and test methods used for fault protection testing are described. The paper concludes with a presentation of the results of this testing with an emphasis on requirement and design changes that were made as a result of these tests.

Anderson, L. L.↗

Design, development and test of shuttle/Centaur G-prime cryogenic tankage thermal protection systems

The thermal protection systems for the shuttle/Centaur would have had to provide fail-safe thermal protection during prelaunch, launch ascent, and on-orbit operations as well as during potential abort. The thermal protection systems selected used a helium-purged polyimide foam beneath three rediation shields for the liquid-hydrogen tank and radiation shields only for the liquid-oxygen tank (three shields on the tank sidewall and four on the aft bulkhead). A double-walled vacuum bulkhead separated the two tanks. The liquid-hydrogen tank had one 0.75-in-thick layer of foam on the forward bulkhead and two layers on the larger area sidewall. Full scale tests of the flight vehicle in a simulated shuttle cargo bay that was purged with gaseous nitrogen gave total prelaunch heating rates of 88,500 Btu/hr and 44,000 Btu/hr for the liquid-hydrogen and -oxygen tanks, respectively. Calorimeter tests on a representative sample of the liquid-hydrogen tank sidewall thermal protection system indicated that the measured unit heating rate would rapidly decrease from the prelaunch rate of approx 100 Btu/hr/sq ft to a desired rate of less than 1.3 Btu/hr/sq ft once on orbit.

Knoll, Richard H.↗

Memory protection

Accidental overwriting of files or of memory regions belonging to other programs, browsing of personal files by superusers, Trojan horses, and viruses are examples of breakdowns in workstations and personal computers that would be significantly reduced by memory protection. Memory protection is the capability of an operating system and supporting hardware to delimit segments of memory, to control whether segments can be read from or written into, and to confine accesses of a program to its segments alone. The absence of memory protection in many operating systems today is the result of a bias toward a narrow definition of performance as maximum instruction-execution rate. A broader definition, including the time to get the job done, makes clear that cost of recovery from memory interference errors reduces expected performance. The mechanisms of memory protection are well understood, powerful, efficient, and elegant. They add to performance in the broad sense without reducing instruction execution rate.

Denning, Peter J.↗

Advances in lightning protection that satisfies contemporary standards

Described here are the LEC, Inc. Spline Ball Ionizer (trademark) (SBI) and the Spline Ball Terminal (trademark) (SBT) families and how their use in a conventional lightning protection system can achieve strike prevention in a conventional setting. A properly completed standards based system which is composed of the SBI and SBT in a hybrid system will provide two modes of lightning protection: (1) a stroke prevention mode that reduces the risk of a strike to the protected facility in proportion to the size of that facility and the size and number of SBI/SBT's used; and (2) a Stroke Collector-Diverter System that is far superior to any system now in use because it collects strokes entering the protected area from any direction and angle.

Carpenter, Roy B., Jr.↗

Planetary protection policy (U.S.A.)

Through existing treaty obligations of the United States, NASA is committed to exploring space while avoiding biological contamination of the planets, and to the protection of the earth against harm from materials returned from space. Because of the similarities between Mars and earth, plans for the exploration of Mars evoke discussions of these Planetary Protection issues. U.S. Planetary Protection Policy will be focused on the preservation of these goals in an arena that will change with the growth of scientific knowledge about the Martian environment. Early opportunities to gain the appropriate data will be used to guide later policy implementation. Because human presence on Mars will result in the end of earth's separation from the Martian environment, it is expected that precursor robotic missions will address critical planetary protection concerns before humans arrive.

Rummel, John D.↗

Monte Carlo modeling of atomic oxygen attack of polymers with protective coatings on LDEF

Characterization of the behavior of atomic oxygen interaction with materials on the Long Duration Exposure Facility (LDEF) assists in understanding of the mechanisms involved. Thus the reliability of predicting in-space durability of materials based on ground laboratory testing should be improved. A computational model which simulates atomic oxygen interaction with protected polymers was developed using Monte Carlo techniques. Through the use of an assumed mechanistic behavior of atomic oxygen interaction based on in-space atomic oxygen erosion of unprotected polymers and ground laboratory atomic oxygen interaction with protected polymers, prediction of atomic oxygen interaction with protected polymers on LDEF was accomplished. However, the results of these predictions are not consistent with the observed LDEF results at defect sites in protected polymers. Improved agreement between observed LDEF results and predicted Monte Carlo modeling can be achieved by modifying of the atomic oxygen interactive assumptions used in the model. LDEF atomic oxygen undercutting results, modeling assumptions, and implications are presented.

Banks, Bruce A.↗

An Analytical Study of Heat Requirements for Icing Protection of Radomes

The heat requirements for the icing protection of two radome configurations have been studied over a range of design icing conditions. Both the protection limits of a typical thermal protection system and the relative effects of the various icing variables have been determined. For full evaporation of all impinging water, an effective heat density of 14 watts per square inch was required. When a combination of the evaporation and running wet surface systems was employed, a heat requirement of 5 watts per square inch provided protection at severe icing and operating conditions.

James P. Lewis↗

The Corrosion Protection of Metals by Ion Vapor Deposited Aluminum

A study of the corrosion protection of substrate metals by ion vapor deposited aluminum (IVD Al) coats has been carried out. Corrosion protection by both anodized and unanodized IVD Al coats has been investigated. Base metals included in the study were 2219-T87 Al, 7075-T6 Al, Titanium-6 Al-4 Vanadium (Ti-6Al-4V), 4130 steel, D6AC steel, and 4340 steel. Results reveal that the anodized IVD Al coats provide excellent corrosion protection, but good protection is also achieved by IVD Al coats that have not been anodized.

Danford, M. D.↗

Atomic oxygen interaction at defect sights in protective coatings on polymers flown on LDEF

Although the Long Duration Exposure Facility (LDEF) has exposed materials with a fixed orientation relative to the ambient low-Earth-orbital environment, arrival of atomic oxygen is angularly distributed as a result of the atomic oxygen's high temperature Maxwellian velocity distribution and the LDEF's orbital inclination. Thus, atomic oxygen entering defects in protective coatings on polymeric surfaces can cause wider undercut cavities than the size of the defect in the protective coating. Because only a small fraction of atomic oxygen reacts upon first impact with most polymeric materials, secondary reactions with lower energy thermally accommodated atomic oxygen can occur. The secondary reactions of scattered and/or thermally accommodated atomic oxygen also contribute to widening the undercut cavity beneath the protective coating defect. As the undercut cavity enlarges, exposing more polymer, the probability of atomic oxygen reacting with underlying polymeric material increases because of multiple opportunities for reaction. Thus, the effective atomic oxygen erosion yield for atoms entering defects increases above that of the unprotected material. Based on the results of analytical modeling and computational modeling, aluminized Kapton multilayer insulation exposed to atomic oxygen on row 9 lost the entire externally exposed layer of polyimide Kapton, yet based on the results of this investigation, the bottom surface aluminum film must have remained in place, but crazed. Atomic oxygen undercutting at defect sites in protective coatings on graphite epoxy composites indicates that between 40 to 100 percent of the atomic oxygen thermally accommodates upon impact, and that the reaction probability of thermally accommodated atomic oxygen may range from 7.7 x 10(exp -6) to 2.1 x 10(exp -3), depending upon the degree of thermal accommodation upon each impact.

Banks, Bruce A.↗

Atomic oxygen interactions with protected organic materials on the Long Duration Exposure Facility (LDEF)

The Long Duration Exposure Facility (LDEF) has provided an excellent opportunity to understand the nature of directed atomic oxygen interactions with protected polymers and composites. Although there were relatively few samples of materials with protective coatings on their external surfaces on LDEF which were exposed to a high atomic oxygen fluence, analysis of such samples has enabled an examination of the shape of atomic oxygen undercut cavities at defect sites in the protective coatings. Samples of front-surface aluminized (Kapton) polyimide were inspected by scanning electron microscopy to identify and measure crack defects in the aluminum protective coatings. After chemical removal of the aluminum coating, measurements were also made of the width of the oxidized undercut cavities below the crack defects. The LDEF flight undercut cavity geometries were then compared with Monte Carlo computational model undercut cavity predictions. The comparison of the LDEF results and computational modeling indicates agreement in specific undercut cavity geometries for atomic oxygen reaction probabilities dependent upon the 0.68 to 3.0 power of the energy. However, no single energy dependency was adequate to replicate flight results over a variety of aluminum crack widths.

Banks, Bruce A.↗

Replacement of corrosion protection chromate primers and paints used in cryogenic applications on the Space Shuttle with wire arc sprayed aluminum coatings

With the advent of new environmental laws restricting volatile organic compounds and hexavalent chrome emissions, 'environmentally safe' thermal spray coatings are being developed to replace the traditional corrosion protection chromate primers. A wire arc sprayed aluminum coating is being developed for corrosion protection of low pressure liquid hydrogen carrying ducts on the Space Shuttle Main Engine. Currently, this hardware utilizes a chromate primer to provide protection against corrosion pitting and stress corrosion cracking induced by the cryogenic operating environment. The wire are sprayed aluminum coating has been found to have good potential to provide corrosion protection for flight hardware in cryogenic applications. The coating development, adhesion test, corrosion test and cryogenic flexibility test results will be presented.

Daniel, R. L.↗