Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Low Precision for Lower Energy Consumption: Preprint

Low-precision numeric types offer significant efficiency and energy benefits for computing applications. Mixed-precision algorithms, combining low and high precision types, maintain accuracy while improving performance. Despite advantages, there exist challenges on adapting existing mixed-precision algorithms to new technologies, such as new hardware architectures and new low-precision data types. This paper presents current challenges and opportunities to advance science in this domain targetting more energy efficient solutions.

energy efficiency↗

A GPU Accelerated Mixed‐Precision Finite Difference Informed Random Walker (FDiRW) Solver for Strongly Inhomogeneous Diffusion Problems

In nature, many complex multi‐physics coupling problems exhibit significant diffusivity inhomogeneity, where one process occurs several orders of magnitude faster than others temporally. Simulating rapid diffusion alongside slower processes demands intensive computational resources due to the necessity for small time steps. To address these computational challenges, we have developed an efficient numerical solver named Finite Difference informed Random Walker (FDiRW). In this study, we propose a GPU‐accelerated, mixed‐precision configuration for the FDiRW solver to maximize efficiency through GPU multi‐threaded parallel computation and lower precision computation. Numerical evaluation results reveal that the proposed GPU‐accelerated mixed‐precision FDiRW solver can achieve a 117× speedup over the CPU baseline, while an additional 1.75× speedup is achieved by employing lower precision GPU computation. Notably, for large model sizes, the GPU‐accelerated mixed‐precision FDiRW solver demonstrates strong scaling with the number of nodes used in simulation. When simulating radionuclide absorption processes by porous wasteform particles with a medium‐sized model of 192 × 192 × 192, this approach reduces the total computational time to 10 min, enabling the simulation of larger systems with strongly inhomogeneous diffusivity.

97 MATHEMATICS AND COMPUTING↗

Creating high-precision reference gas standards of 85Kr for groundwater age-dating

Absolute gas counting (AGC) was applied to two gas blends of 85Kr in argon-methane (P10) counting gas to establish a high-precision specific activity (Bq/cm3) reference value for characterizing 85Kr detection efficiency for groundwater age dating measurements. The AGC or length-compensated technique has been utilized by the metrology community for decades and is an accepted method for developing radioactive gas standards. The AGC capability at Pacific Northwest National Laboratory (PNNL) uses a set of nine unequal-length proportional counters with precisely-measured internal volumes, and a gas loading system with high-precision pressure and temperature sensors. A series of AGC measurements were collected at multiple pressures to determine the inverse pressure relationship (1/P) for 85Kr and define a wall-effect correction that accounts for events decaying into the detector wall and not depositing sufficient energy in the gas to be detected. In addition to the wall-effect, two additional corrections were evaluated and are discussed in detail. Specifically, the threshold effect which accounts for events deposited below the analysis threshold and a detection efficiency as a function of detector volume effect that was observed during analysis. A robust uncertainty model was developed using the Guide to the expression of Uncertainty in Measurements (GUM) approach. The combination of carefully scrutinized correction factors, precise measurements of pressure, temperature and detector volume, and robust counting statistics resulted in the determination of high-precision specific activity values with 0.50% or less total combined uncertainty for two Kr-in-P10 reference gas standards (KP10) that will enable new groundwater age-dating measurements at PNNL.

Kr-85↗

Relation between sampling, sensitivity and precision in strain mapping using the Geometric Phase Analysis method in Scanning Transmission Electron Microscopy

The sensitivity and the precision of the Geometric Phase Analysis (GPA) method for strain characterization is a topic widely discussed in the literature and is usually difficult to quantify. Indeed, the GPA precision is intricately linked to the resolution of the strain maps defined when masking the periodic reflections in Fourier space. In this study an additional parameter, sampling, is proposed to be analyzed regarding the precision of GPA by developing the concept of a phase noise in the GPA equations. Both experimentally and theoretically, the following article demonstrates how the precision, and the sensitivity of the GPA method is improved when using a larger pixel spacing to record an electron micrograph in Scanning Transmission Electron Microscopy (STEM). In conclusion, the counterintuitive concept of increasing the field of view to improve the GPA precision results in an extension of the application of strain characterization methods in STEM towards low deformation levels.

47 OTHER INSTRUMENTATION↗

Efficient Mixed-Precision Matrix Factorization of the Inverse Overlap Matrix in Electronic Structure Calculations with AI-Hardware and GPUs

In recent years, a new kind of accelerated hardware has gained popularity in the artificial intelligence (AI) community which enables extremely high-performance tensor contractions in reduced precision for deep neural network calculations. In this article, we exploit Nvidia Tensor cores, a prototypical example of such AI-hardware, to develop a mixed precision approach for computing a dense matrix factorization of the inverse overlap matrix in electronic structure theory, S –1 . This factorization of S –1 , written as ZZT = S –1 , is used to transform the general matrix eigenvalue problem into a standard matrix eigenvalue problem. Here we present a mixed precision iterative refinement algorithm where Z is given recursively using matrix–matrix multiplications and can be computed with high performance on Tensor cores. To understand the performance and accuracy of Tensor cores, comparisons are made to GPU-only implementations in single and double precision. Additionally, we propose a nonparametric stopping criteria which is robust in the face of lower precision floating point operations. The algorithm is particularly useful when we have a good initial guess to Z, for example, from previous time steps in quantum-mechanical molecular dynamics simulations or from a previous iteration in a geometry optimization.

36 MATERIALS SCIENCE↗

Modelling kidney disease using ontology: insights from the Kidney Precision Medicine Project

An important need exists to better understand and stratify kidney disease according to its underlying pathophysiology in order to develop more precise and effective therapeutic agents. National collaborative efforts such as the Kidney Precision Medicine Project are working towards this goal through the collection and integration of large, disparate clinical, biological and imaging data from patients with kidney disease. Ontologies are powerful tools that facilitate these efforts by enabling researchers to organize and make sense of different data elements and the relationships between them. Ontologies are critical to support the types of big data analysis necessary for kidney precision medicine, where heterogeneous clinical, imaging and biopsy data from diverse sources must be combined to define a patient’s phenotype. Here, the development of two new ontologies — the Kidney Tissue Atlas Ontology and the Ontology of Precision Medicine and Investigation — will support the creation of the Kidney Tissue Atlas, which aims to provide a comprehensive molecular, cellular and anatomical map of the kidney. These ontologies will improve the annotation of kidney-relevant data, and eventually lead to new definitions of kidney disease in support of precision medicine.

60 APPLIED LIFE SCIENCES↗

High-precision measurement of the W boson mass with the CMS experiment

In the standard model of particle physics, the masses of the W and Z bosons, the carriers of the weak interaction, are uniquely related. A precise determination of their masses is important because quantum loops of heavy, undiscovered particles could modify this relationship. Although the Z mass is known to the remarkable precision of 22 parts per million (2.0 MeV), the W mass is known much less precisely. A global fit to measured electroweak observables predicts the W mass with 6 MeV uncertainty [1$-$3]. Reaching a comparable experimental precision would be a sensitive and fundamental test of the standard model, made even more urgent by a recent challenge to the global fit prediction by a measurement from the CDF Collaboration at the Fermilab Tevatron collider [4]. Here we report the measurement of the W mass by the CMS Collaboration at the CERN LHC, based on a large data sample of $W \to \mu \nu$ events collected in 2016 at the proton-proton collision energy of 13 TeV. The measurement exploits a high-granularity maximum likelihood fit to the kinematic properties of muons produced in W decays. By combining an accurate determination of experimental effects with marked in situ constraints of theoretical inputs, we reach a precise measurement of the W mass, of 80 360.2 $\pm$ 9.9 MeV, in agreement with the standard model prediction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

HIGH-PRECISION ORBITAL AND PHYSICAL PARAMETERS OF DOUBLE-LINED SPECTROSCOPIC BINARY STARS-HD78418, HD123999, HD160922, HD200077, AND HD210027

We present high-precision radial velocities (RVs) of double-lined spectroscopic binary stars HD78418, HD123999, HD160922, HD200077, and HD210027. They were obtained based on the high-resolution echelle spectra collected with the Keck I/HIRES, Shane/CAT/Hamspec, and TNG/Sarge telescopes/spectrographs over the years 2003-2008 as part of the TATOOINE search for circumbinary planets. The RVs were computed using our novel iodine cell technique for double-line binary stars, which relies on tomographically disentangled spectra of the components of the binaries. The precision of the RVs is of the order of 1-10 m s{sup -1}, and to properly model such measurements one needs to account for the light-time effect within the binary's orbit, relativistic effects, and RV variations due to tidal distortions of the components of the binaries. With such proper modeling, our RVs combined with the archival visibility measurements from the Palomar Testbed Interferometer (PTI) allow us to derive very precise spectroscopic/astrometric orbital and physical parameters of the binaries. In particular, we derive the masses, the absolute K- and H-band magnitudes, and the parallaxes. The masses together with the absolute magnitudes in the K and H bands enable us to estimate the ages of the binaries. These RVs allow us to obtain some of the most accurate mass determinations of binary stars. The fractional accuracy in msin i only, and hence based on the RVs alone, ranges from 0.02% to 0.42%. When combined with the PTI astrometry, the fractional accuracy in the masses in the three best cases ranges from 0.06% to 0.5%. Among them, the masses of HD210027 components rival in precision the mass determination of the components of the relativistic double pulsar system PSR J0737 - 3039. In the near future, for double-lined eclipsing binary stars we expect to derive masses with a fractional accuracy of the order of up to {approx}0.001% with our technique. This level of precision is an order of magnitude higher than of the most accurate mass determination for a body outside the solar system-the double neutron star system PSR B1913+16.

79 ASTRONOMY AND ASTROPHYSICS↗

High precision measurements of the proton elastic electromagnetic form factors and their ratio at 𝑄 2 = 0.50, 2.64, 3.20, and 4.10 GeV 2

The advent of high-intensity, high-polarization electron beams led to significantly improved measurements of the ratio of the proton’s charge to electric form factors, 𝐺 𝐸⁢ 𝑝 ⁡/𝐺 𝑀⁢ 𝑝 . However, high-𝑄 2 measurements of this ratio yielded significant disagreement with extractions based on unpolarized scattering measurements, raising questions about the reliability of the measurements and consistency of the techniques. Jefferson Lab experiment E01-001 was designed to provide a high precision extraction of 𝐺 𝐸⁢ 𝑝 ⁡/𝐺 𝑀⁢ 𝑝 from unpolarized cross-section measurements using a modified version of the Rosenbluth separation technique to allow for a more precise comparison with polarization data. Rosenbluth separations involve precise measurements of the angular dependence of the elastic 𝑒−𝑝 cross section at fixed momentum transfer, 𝑄 2 . Conventional Rosenbluth separations detect the scattered electron, requiring the comparisons of measurements with very different detected electron energy and rate for electrons at different angles. Our ‘‘super-Rosenbluth’’ measurement detected the struck proton, rather than the scattered electron to extract the elastic 𝑒−𝑝 cross section. This yielded a fixed momentum for the detected particle and dramatically reduced variation of the cross section with angle, significantly reducing rate- and momentum-dependent corrections and uncertainties. We measure the cross section vs angle with high relative precision, allowing for extremely high precision extractions of 𝐺 𝐸⁢ 𝑝 ⁡/𝐺 𝑀⁢ 𝑝 at 𝑄 2 = 2.64, 3.20, and 4.10 GeV 2 . Our results are consistent with traditional Rosenbluth extractions, but with much smaller corrections and systematic uncertainties, comparable to the uncertainties from polarization measurements. Our data confirm the discrepancy between Rosenbluth and polarization extractions of the proton form factor ratio using an improved Rosenbluth extraction that yields smaller and less-correlated uncertainties than those typical of previous Rosenbluth extractions. Here, we compare our results to calculations of two-photon exchange effects and find that the observed discrepancy can be relatively well explained by such effects.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Clock Precision beyond the Standard Quantum Limit at 10 −18 Level

Optical atomic clocks with unrivaled precision and accuracy have advanced the frontier of precision measurement science and opened new avenues for exploring fundamental physics. A fundamental limitation on clock precision is the standard quantum limit (SQL), which stems from the uncorrelated projection noise of each atom. State-of-the-art optical lattice clocks interrogate large ensembles to minimize the SQL, but density-dependent frequency shifts pose challenges to scaling the atom number. The SQL can be surpassed, however, by leveraging entanglement, though it remains an open problem to achieve quantum advantage from spin squeezing at state-of-the-art stability levels. Here, we demonstrate clock performance beyond the SQL, achieving a fractional frequency precision of 1.1 × 10 −18 for a single spin-squeezed clock. With cavity-based quantum nondemolition measurements, we prepare two spin-squeezed ensembles of ∼30 000 strontium atoms confined in a two-dimensional optical lattice. A synchronous clock comparison with an interrogation time of 61 ms achieves a metrological improvement of 2.0(2) dB beyond the SQL, after correcting for state preparation and measurement errors. These results establish the most precise entanglement-enhanced clock to date and offer a powerful platform for exploring the interplay of gravity and quantum entanglement.

cavity quantum electrodynamics↗

High precision 5 MeV Mott polarimeter

We report on the design and performance of a Mott polarimeter optimized for a nominal 5-MeV electron beam from the Continuous Electron Beam Accelerator Facility (CEBAF) injector. The rf time structure of this beam allows the use of time of flight in the scattered electron detection, making it possible to cleanly isolate those detected electrons that originate from the scattering foil, and resulting in measured scattering asymmetries which are exceptionally stable over a broad range of beam conditions, beam currents, and foil thicknesses. In two separate series of measurements from two different photocathode electron sources, we have measured the Mott scattering asymmetries produced by an approximately 86% transversely polarized electron beam incident on ten gold foils with nominal thicknesses between 50 and 1000 nm. The statistical uncertainty of the measured asymmetry from each foil is below 0.25%. Within this statistical precision, the measured asymmetry was unaffected by ±1-mm shifts in the beam position on the target foil, and by beam current changes and dead-time effects over a wide range of beam currents. The overall uncertainty of our beam polarization measurement, arising from the uncertainty in the value of the scattering asymmetry at zero foil thickness as determined from our fits to the measured asymmetries versus scattering foil thicknesses, the estimated systematic effects, and the (dominant) uncertainty from the calculation of the theoretical Sherman function, is 0.61%. A simulation of the polarimeter using geant4 has confirmed that double scattering in the target foil is the sole source of the dependence of the measured asymmetry on foil thickness, and gives a result for the asymmetry versus foil thickness in good agreement with both our measurements and a simple calculation. Future measurements at different beam energies and with target foils of different atomic numbers will seek to bound uncertainties from small effects such as radiative corrections to the calculation of the polarimeter analyzing power. A simultaneous high-precision measurement of the beam polarization with a different polarimeter, AESOP (Accurate Electron Spin Optical Polarimeter), under development at the University of Nebraska, clearly possible at the CEBAF accelerator, will allow a high-precision comparison of our measured asymmetries with theoretical calculations of the Mott analyzing power. Finally, the improved precision of the current Mott polarimeter along with similar improvements to other Jefferson Lab polarimeters warrants another precision comparison of all of these polarimeters when measuring a beam of the same polarization.

Grames, J. M. (ORCID:0000000193908752)↗

Nuclear charge densities in spherical and deformed nuclei: Toward precise calculations of charge radii

Precise measurements of atomic transitions affected by electron-nucleus hyperfine interactions offer sensitivity to explore basic properties of the atomic nucleus and study fundamental symmetries, including the search for new physics beyond the standard model of particle physics. Specifically, such measurements, augmented by atomic and nuclear calculations, will enable extraction of the higher-order radial moments of the charge-density distribution in spherical and deformed nuclei. The new data impose higher precision requirements on a theoretical description. The nuclear charge density is composed of the proton point distribution folded with the nucleonic charge distributions. The latter induce subtle relativistic corrections due to the coupling of nucleon magnetic moments with the nuclear spin-orbit density. Additional corrections come from the effect of center-of-mass projection. We assess the precision of nuclear charge density calculations by studying the behavior of relativistic and center-of-mass motion corrections to the second and fourth charge radial moments. Special attention has been paid to the magnetic spin-orbit density associated with the local variations of the spin-orbit current. The calculations for semimagic and open-shell nuclei are performed in the framework of self-consistent mean-field theory using quantified energy density functionals and density-dependent pairing forces. We used the general expression for the spin-orbit form factor that is valid for spherical and deformed nuclei. We studied the impact of various correction terms on the charge radii, fourth radial moments, diffraction radii, and surface thickness of spherical and deformed nuclei. The spin-orbit corrections to charge radial moments and surface thickness show strong shell fluctuations which can make an appreciable effect when aiming at high-precision predictions of isotopic shifts. The inclusion of relativistic and center-of-mass corrections impacts the quality of energy density functionals optimized to charge radii data. To establish reliable constraints on the existence of new forces from isotope shift measurements, precise calculations of nuclear charge densities of deformed nuclei are needed. The proper inclusion of the spin-orbit charge density and other correction terms is essential when aiming at extraction of subtle effects which become particularly visible in isotopic trends. It is also important when developing high-quality nuclear energy density functionals optimized using heterogeneous datasets involving absolute charge radii, differential charge radii, and charge form factor properties deduced from electron-scattering data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quantifying the impact of precision errors on quantum approximate optimization algorithms

The quantum approximate optimization algorithm (QAOA) is a hybrid quantum-classical algorithm that seeks to achieve approximate solutions to optimization problems by iteratively alternating between intervals of controlled quantum evolution. Here, we examine the effect of analog precision errors on QAOA performance from the perspective of both algorithmic training and performance guarantees. Leveraging cumulant expansions, we recast the faulty QAOA as a control problem in which precision errors are expressed as multiplicative control noise and derive bounds on the performance of QAOA. We show using both analytical techniques and numerical simulations that fixed precision implementations of QAOA circuits are subject to an exponential degradation in performance dependent upon the number of optimal QAOA layers and magnitude of the precision error. Despite this significant reduction, we show that it is possible to mitigate precision errors in QAOA via digitization of the variational parameters at the cost of increasing circuit depth.

quantum algorithms↗

Precise Timing Based on Pulsar Observation for Grid Synchronization

While Global Positioning System signals are widely used as the synchronized timing Sources for wide-area measurement systems for power grid monitoring and control, they are vulnerable to failures and malicious attacks. To address this Problem, an alternative kind of timing sources, the millisecond pulsars, were proposed to serve the power grid as they are more precise and physically indestructible. Millisecond pulsars are a kind of neutron stars that emit radio pulse signals that have extremely stable periods of milliseconds. However, the observed pulse Signals from pulsars cannot be directly used for timing because of their low signal-to-noise ratio and the dispersion effects of interstellar medium. In this paper, the precise timing method based on pulsar observation data is proposed to interpret the pulsar observation data and therefrom to generate precise timing signal for the power grid synchronization. In our proposed method,. incoherent de-dispersion is used on the observation data to mitigate the effect of interstellar medium. dispersion. Then spectrum analysis and segment folding are used to precisely estimate the local pulsar period. Finally the standard pulse per second signal is generated from. the estimated pulsar period and its precision. is analyzed. Experiments with the observation data of the pulsar based timing signal can be more accurate compared to GPS timing signals.

Luo, Xiqian↗

Climbing the Summit and Pushing the Frontier of Mixed Precision Benchmarks at Extreme Scale

The rise of machine learning (ML) applications and their use of mixed precision to perform interesting science are driving forces behind AI for science on HPC. The convergence of ML and HPC with mixed precision offers the possibility of transformational changes in computational science. The HPL-AI benchmark is designed to measure the performance of mixed precision arithmetic as opposed to the HPL benchmark which measures double precision performance. Pushing the limits of systems at extreme scale is nontrivial -little public literature explores optimization of mixed precision computations at this scale. In this work, we demonstrate how to scale up the HPL-AI benchmark on the pre-exascale Summit and exascale Frontier systems at the Oak Ridge Leadership Computing Facility (OLCF) with a cross-platform design. We present the implementation, performance results, and a guideline of optimization strategies employed for delivering portable performance on both AMD and NVIDIA GPUs at extreme scale.

Lu, Hao↗

Precision of dosimetry-related measurements obtained on current multidetector computed tomography scanners

Purpose: Computed tomography (CT) intrascanner and interscanner variability has not been well characterized. Thus, the purpose of this study was to examine the within-run, between-run, and between-scanner precision of physical dosimetry-related measurements collected over the course of 1 yr on three different makes and models of multidetector row CT (MDCT) scanners. Methods: Physical measurements were collected using nine CT scanners (three scanners each of GE VCT, GE LightSpeed 16, and Siemens Sensation 64 CT). Measurements were made using various combinations of technical factors, including kVp, type of bowtie filter, and x-ray beam collimation, for several dosimetry-related quantities, including (a) free-in-air CT dose index (CTDI{sub 100,air}); (b) calculated half-value layers and quarter-value layers; and (c) weighted CT dose index (CTDI{sub w}) calculated from exposure measurements collected in both a 16 and 32 cm diameter CTDI phantom. Data collection was repeated at several different time intervals, ranging from seconds (for CTDI{sub 100,air} values) to weekly for 3 weeks and then quarterly or triannually for 1 yr. Precision of the data was quantified by the percent coefficient of variation (%CV). Results: The maximum relative precision error (maximum %CV value) across all dosimetry metrics, time periods, and scanners included in this study was 4.33%. The median observed %CV values for CTDI{sub 100,air} ranged from 0.05% to 0.19% over several seconds, 0.12%-0.52% over 1 week, and 0.58%-2.31% over 3-4 months. For CTDI{sub w} for a 16 and 32 cm CTDI phantom, respectively, the range of median %CVs was 0.38%-1.14% and 0.62%-1.23% in data gathered weekly for 3 weeks and 1.32%-2.79% and 0.84%-2.47% in data gathered quarterly or triannually for 1 yr. Conclusions: From a dosimetry perspective, the MDCT scanners tested in this study demonstrated a high degree of within-run, between-run, and between-scanner precision (with relative precision errors typically well under 5%).

60 APPLIED LIFE SCIENCES↗

Metabolic model predictions enable targeted microbiome manipulation through precision prebiotics

While numerous health-beneficial interactions between host and microbiota have been identified, there is still a lack of targeted approaches for modulating these interactions. Thus, we here identify precision prebiotics that specifically modulate the abundance of a microbiome member species of interest. In the first step, we show that defining precision prebiotics by compounds that are only taken up by the target species but no other species in a community is usually not possible due to overlapping metabolic niches. Subsequently, we use metabolic modeling to identify precision prebiotics for a two-member Caenorhabditis elegans microbiome community comprising the immune-protective target species Pseudomonas lurida MYb11 and the persistent colonizer Ochrobactrum vermis MYb71. We experimentally confirm four of the predicted precision prebiotics, L-serine, L-threonine, D-mannitol, and γ-aminobutyric acid, to specifically increase the abundance of MYb11. L-serine was further assessed in vivo, leading to an increase in MYb11 abundance also in the worm host. Overall, our findings demonstrate that metabolic modeling is an effective tool for the design of precision prebiotics as an important cornerstone for future microbiome-targeted therapies.

59 BASIC BIOLOGICAL SCIENCES↗

APNN-TC: Accelerating Arbitrary Precision Neural Networks on Ampere GPU Tensor Cores

Over the years, accelerating neural networks with quantization has been widely studied. Unfortunately, prior efforts with diverse precisions (e.g., 1-bit weights and 2-bit activations) are usually restricted by limited precision support on GPUs (e.g., int1 and int4). To break such restrictions, we introduce the first Arbitrary Precision Neural Network framework (APNN-TC) to fully exploit quantization benefits on Ampere GPU Tensor Cores. Specifically, APNN-TC first incorporates a novel emulation algorithm to support arbitrary short bit-width computation with int1 compute primitives and XOR/AND Boolean operations. Second, APNN-TC integrates arbitrary precision layer designs to efficiently map our emulation algorithm to Tensor Cores with novel batching strategies and specialized memory organization. Third, APNN-TC embodies a novel arbitrary precision NN design to minimize memory access across layers and further improve performance. Extensive evaluations show that APNN-TC can achieve significant speedup over CUTLASS kernels and various NN models, such as ResNet and VGG.

Feng, Boyuan↗