Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power system monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Electric-Power System Simulator

Shows different combinations of generation, storage, and load components: display, video monitor with keyboard input to microprocessor, and video monitor for display of load curves and power generation. Planning tool for electric utilities, regulatory agencies, and laymen in understanding basics of electric-power systems operation.

Caldwell, R. W.↗

Smart Meter Pinging and Reading Through AMI Two-Way Communication Networks to Monitor Grid Edge Devices and DERs

Today’s power distribution system is changing to a power-electronics-enabled distribution system, especially with the increasing penetration of distributed energy resources (DERs). To monitor and manage those electronic devices and DERs at the grid edge, the advanced metering infrastructure (AMI) with two-way communications presents great potential. At present, extensive research explores the upstream communication from smart meters to electric utilities (e.g., meter reading) but few examine the downstream communication from the utilities to smart meters (e.g., meter pinging). This article discusses the AMI two-way communication and its recent industrial practice in the U.S., especially for applying the smart meter pinging functionality to monitor grid-edge devices and DERs. This paper then develops the two-way communication model and the network calculus method to quantify the impact of the two-way communication on the AMI network. In the end, the proposed method is validated with ns-3 simulation using the modified 13-node test feeder and real-world feeder systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Brief Survey on High Performance Computing Systems Power Management

This paper provides a survey of software-based power management techniques in High Performance Computing (HPC) systems. Seven existing power management and monitoring tools and frameworks are discussed. These are: Variorum, dynamic energy-performance optimizer (DEPO), Powersched, Bull Dynamic Power Optimizer (BDPO), Energy Aware Runtime (EAR), Global Extensible Open Power Manager (GEOPM), and PoLiMEr. Each of these tools is evaluated based on hardware abstraction, optimization methods, usability, and experimental validation. This survey highlights the diversity of approaches in managing energy efficiency, from vendor-neutral APIs to algorithm-driven power capping, and dynamic frequency adjustments. Given that energy requirements for large computational systems is increasing quickly, the importance of integrating these tools into existing HPC environments and the need for further research in this rapidly evolving field is also discussed.

97 - MATHEMATICS AND COMPUTING↗

Data Driven Online Learning of Power System Dynamics

With the advancement of sensing and communication in power networks, high-frequency real-time data from a power network can be used as a resource to develop better monitoring capabilities. In this work, a systematic approach based on data-driven operator theoretic methods involving Koopman operator is proposed for the online identification of power system dynamics. In particular, a new algorithm is provided, which unlike any previously existing algorithms, updates the Koopman operator iteratively as new data points are acquired. The proposed algorithm has three advantages: a) allows for real-time monitoring of the power system dynamics b) linear power system dynamics (this linear system is usually in a higher dimensional feature space and is not same as linearization of the underlying nonlinear dynamics) and c) computationally fast and less intensive when compared to the popular Extended Dynamic Mode Decomposition (EDMD) algorithm. The efficiency of the proposed algorithm is illustrated on an IEEE 9 bus system using synthetic data from the nonlinear model and on IEEE 39 bus system using synthetic data from the linearized model.

Sinha, Subhrajit↗

ReNew100: Reliable Power System Operation with 100% Renewable Generation

The ReNew100 project has developed and demonstrated an operator support system (OSS) to operate power systems with 100% renewable power generation from inverter-based resources (IBRs) like wind and solar that significantly reduces the risk of widespread power outages in a simulated operational environment at Technology Readiness Level (TRL) 6. The OSS achieves resilient operation for power systems under changing operation modes including varying combinations of conventional and renewable generation, including cases with 100% renewable generation from wind and solar IBRs. The OSS continuously monitors the N-1 security of the power system, which refers to the ability of the power systems to survive single outages of power system elements, like the loss of a generator or a power line, without causing widespread power outages beyond those expected and planned for. If the OSS identifies that the system is not N-1 secure, an automatic Controller Parameter Optimization (CoPO) developed within Renew100 is activated to optimize the N-1 security of the system by tuning controller parameters within different assets like batteries, wind, and solar plants. The core innovation of ReNew100 is the development of this CoPO as well as the demonstration of the OSS for a real-time simulation of the Hawai'i Island power system. Moreover, Renew100 has developed new model calibration techniques for dynamic power system models and demonstrated them for Hawai'i Island.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of an Innovative Inspection Tool for Superheater Tubes in Fossil Fuel Power Plants

Fossil fuel power plants are complex systems containing multiple components that require periodic health monitoring. Failures in these systems can lead to increased downtime for the plant, reduction of power, and significant cost for repairs. Inspections of the plant’s superheater tubes are typically manual, laborious, and extremely time-consuming. This is due to their small diameter size (between 1.3 and 7.6 cm) and the coiled structure of the tubing. In addition, the tubes are often stacked close to each other, limiting access for external inspection. This paper presents the development and testing of an electrically powered pipe crawler that can navigate inside 5 cm diameter tubes and provide an assessment of their health. The crawler utilizes peristaltic motion within the tubes via interconnected modules for gripping and extending. The modular nature of the system allows it to traverse through straight sections and multiple 90° and 180° bends. Additional modules in the system include an ultrasonic sensor for tube thickness measurements, as well as environmental sensors, a light detecting and ranging (LiDAR) sensor, and camera. Furthermore, these modules utilize a gear system that allows for 360° rotation and provides a means to inspect the entire internal circumference of the tubes.

36 MATERIALS SCIENCE↗

Reducing the cognitive workload - Trouble managing power systems

The complexity of space-based systems makes monitoring them and diagnosing their faults taxing for human beings. When a problem arises, immediate attention and quick resolution is mandatory. To aid humans in these endeavors we have developed an automated advisory system. Our advisory expert system, Trouble, incorporates the knowledge of the power system designers for Space Station Freedom. Trouble is designed to be a ground-based advisor for the mission controllers in the Control Center Complex at Johnson Space Center (JSC). It has been developed at NASA Lewis Research Center (LeRC) and tested in conjunction with prototype flight hardware contained in the Power Management and Distribution testbed and the Engineering Support Center, ESC, at LeRC. Our work will culminate with the adoption of these techniques by the mission controllers at JSC. This paper elucidates how we have captured power system failure knowledge, how we have built and tested our expert system, and what we believe its potential uses are.

Manner, David B.↗

Reducing the cognitive workload: Trouble managing power systems

The complexity of space-based systems makes monitoring them and diagnosing their faults taxing for human beings. Mission control operators are well-trained experts but they can not afford to have their attention diverted by extraneous information. During normal operating conditions monitoring the status of the components of a complex system alone is a big task. When a problem arises, immediate attention and quick resolution is mandatory. To aid humans in these endeavors we have developed an automated advisory system. Our advisory expert system, Trouble, incorporates the knowledge of the power system designers for Space Station Freedom. Trouble is designed to be a ground-based advisor for the mission controllers in the Control Center Complex at Johnson Space Center (JSC). It has been developed at NASA Lewis Research Center (LeRC) and tested in conjunction with prototype flight hardware contained in the Power Management and Distribution testbed and the Engineering Support Center, ESC, at LeRC. Our work will culminate with the adoption of these techniques by the mission controllers at JSC. This paper elucidates how we have captured power system failure knowledge, how we have built and tested our expert system, and what we believe are its potential uses.

Manner, David B.↗

A Cable Condition Monitoring Strategy for Safe and Reliable Plant Operation

Electrical cables provide essential functions, such as delivery of power or instrumentation signals for monitoring systems. Most cables installed in industrial applications are constructed with organic polymer insulations that can become brittle, crack, or degrade over time from exposure to harsh environmental conditions, such as elevated temperatures, moisture, vibration, mechanical shock, and radiation. This paper describes an overall strategy for assessing the health and managing the aging of cables during the operating life of an industrial facility. This strategy involves performing condition assessments and monitoring of electrical cables using both in situ and laboratory testing techniques. It includes in situ testing to identify anomalies in the circuits, such as degraded terminations, splices, connections, and degraded sections of cable insulation, as well as as-found evaluations to determine the current condition of installed cables. Furthermore, these cable condition evaluations provide important information about the current state of the cable circuits. Moreover, the test results can be used to trend/monitor age-related degradation and estimate the remaining useful life of installed cables.

36 MATERIALS SCIENCE↗

Design and Construction of a High Field Cable Test Facility at Fermilab

Fermi National Accelerator Laboratory, together with Lawrence Berkeley National Laboratory, is building a new High Field Vertical Magnet Test Facility (HFVMTF) to be situated in the Magnet Test Facility at Fermilab. The HFVMTF is jointly funded by the US DOE Offices of Science, High Energy Physics, and Fusion Energy Sciences, and will serve as a superconducting cable test facility for both communities. The background magnetic field for test samples is 15 T and will be produced by a magnet provided by LBNL operating at 1.9 K in superfluid helium. The samples will be placed in the background magnetic field, cooled to between 4.5 K and a user-specified upper limit, and will be powered with a super-conducting transformer at up to 100 kA. Additionally, this facility will be used to test high-field superconducting magnet models and demonstrators, including hybrid magnets, produced by the US Magnet Development Program. Presently, the various tasks of the project are at different stages of execution, from conceptual to ready-for-construction designs. Here, this paper describes the parameters and design status of the pit construction, cryostat, heat exchanger, lambda plate, power system, and quench protection and monitoring systems of the facility.

43 PARTICLE ACCELERATORS↗

Current Status of the High Field Cable Test Facility at Fermilab

Fermi National Accelerator Laboratory (FNAL) and Lawrence Berkeley National Laboratory (LBNL) are collaborating to construct a new High Field Vertical Magnet Test Facility (HFVMTF) designed for testing superconducting cables in high magnetic fields. This state-of-the-art facility will be situated at Fermilab and will provide capabilities comparable to EDIPO at PSI and FRESCA2 at CERN. The HFVMTF’s background magnetic field, reaching 15 T, will be generated by a magnet supplied by LBNL. The HFVMTF is a collaborative effort supported by the US DOE Offices of Science, High Energy Physics, and Fusion Energy Sciences. It will serve as a vital testbed for superconducting HTS cables, subjecting them to high magnetic fields and a wide range of temperatures, benefiting both scientific communities. Additionally, this facility will play a key role in testing high-field superconducting magnet models and demonstrators, including hybrid magnets, developed by the US Magnet Development Pro gram (MDP). These hybrid magnets, utilizing both LTS and HTS superconductors, are significant advancements toward achieving 18+ T dipoles for future hadron-hadron colliders. The presentation outlines the current status of the facility, covering aspects such as construction progress, cryostat designs, top and lambda plates, and systems for powering, quench protection, and monitoring.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Remote Monitor Alarm System

A remote monitor alarm system monitors discrete alarm and analog power supply voltage conditions at remotely located communications terminal equipment. A central monitoring unit (CMU) is connected via serial data links to each of a plurality of remote terminal units (RTUS) that monitor the alarm and power supply conditions of the remote terminal equipment. Each RTU can monitor and store condition information of both discrete alarm points and analog power supply voltage points in its associated communications terminal equipment. The stored alarm information is periodically transmitted to the CMU in response to sequential polling of the RTUS. The number of monitored alarm inputs and permissible voltage ranges for the analog inputs can be remotely configured at the CMU and downloaded into programmable memory at each RTU. The CMU includes a video display, a hard disk memory, a line printer and an audio alarm for communicating and storing the alarm information received from each RTU.

Stute, Robert A.↗

Prototype Software for Future Spaceflight Tested at Mars Desert Research Station

NASA scientists in MDRS Crew 49 (April 23-May 7, 2006) field tested and significantly extended a prototype monitoring and advising system that integrates power system telemetry with a voice commanding interface. A distributed, wireless network of functionally specialized agents interacted with the crew to provide alerts (e.g., impending shut-down of inverter due to low battery voltage), access md interpret historical data, and display troubleshooting procedures. In practical application during two weeks, the system generated speech over loudspeakers and headsets lo alert the crew about the need to investigate power system problems. The prototype system adapts the Brahms/Mobile Agents toolkit to receive data from the OneMeter (Brand Electronics) electric metering system deployed by Crew 47. A computer on the upper deck was connected to loudspeakers, four others were paired with wireless (Bluetooth) headsets that enabled crew members to interact with their personal agents from anywhere in the hab. Voice commands and inquiries included: 1. What is the {battery | generator} {volts | amps | volts and amps}? 2. What is the status of the {generator | inverter | battery | solar panel}? 3. What is the hab{itat} {power usage | volts | voltage | amps | volts and amps}? 4. What was the average hab{itat} {amps | volts | voltage} since <#> {AM | PM)? 5. When did the {generator | batteries} change status? 6. Tell {me I | everyone} when{ ever} the generator goes offline. 7. Tell {me | | everyone} when the hab{itat} {amps | volts | voltage} {exceeds | drops brelow} <#>. 8. {Send | Take | Record} {a} voice note {(for | to} } {at }. This research demonstrates the principles of design in the context of use, investigating requirements through experimental use of prototype systems in an analog setting, and use of MDRS as a research facility for designing and implementing new systems.

Clancey, William J.↗

New Technologies for Power System Operation and Analysis, 1st Edition

New Technologies for Power System Operation and Analysis considers the very latest developments in renewable energy integration and system operation, including electricity markets and wide-area monitoring systems and forecasting. Helping readers quickly grasp the essential information needed to address renewable energy integration challenges, this new book looks at basic power system mathematical models, advanced renewable integration and system optimizations from transmission and distribution system sides. Sections cover wind, solar, gas and petroleum, making this a useful reference for all engineers interested in power system operation.

electricity markets↗

Low-Power, Flexible Sensor Arrays with Solderless Board-to-Board Connectors for Monitoring Soil Deformation and Temperature: Supporting Data

This dataset was used to assess the potential of a Soil Deformation and Temperature Monitoring System developed and presented in the article named "Low-Power, Flexible Sensor Arrays with Solderless Board-to-Board Connectors for Monitoring Soil Deformation and Temperature" and published in Sensors. There are 21 comma-delimited data files (.csv). 14 files contain current measurements performed in a lab setting, enabling the electrical evaluation of the sensor probe. These files are generated by the Keithley DMM6500 multimeter, and list the measured supply current (first column) as a function of time (3rd column). Another set of 6 files is also acquired in lab experiments, but contain soil temperature an deformation measurements, enabling an assessment of the developed device's accuracy. In these files, the first column contains the time (UTC), followed by the sensor's battery voltage and temperature and acceleration values (X, Y, Z) in subsequent columns. The measurements were acquired every 5 seconds. Another .csv file contains field data in a similar format (time, temperature, acceleration) collected at the Teller road (mile 27) site near Nome, Alaska with one probe. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Skylab technology electrical power system

The solar array/battery power systems for the Skylab vehicle were designed to operate in a solar inertial pointing mode to provide power continuously to the Skylab. Questions of power management are considered, taking into account difficulties caused by the reduction in power system performance due to the effects of structural failure occurring during the launching process. The performance of the solar array of the Apollo Telescope Mount Power System is discussed along with the Orbital Workshop solar array performance and the Airlock Module power conditioning group performance. A list is presented of a number of items which have been identified during mission monitoring and are recommended for electrical power system concepts, designs, and operation for future spacecraft.

Woosley, A. P.↗

Power system model parameter conditioning tool

A power system model parameter conditioning tool including a server control processor in communication with phasor measurement unit monitored data records of multiple disturbance events, a model calibration unit providing event screening, power system model simulation, and simultaneous tuning of model parameters. The model calibration performing a simulation using default model parameters, the processor comparing the simulation results to the monitored data. If the prediction is within threshold, then terminating conditioning; else performing parameter identifiability analysis to determine differing effects of various model parameters on power system model accuracy, selecting a parameter set causing a degradation in power system model prediction, and updating the default model parameters corresponding to members of the parameter set with values selected to reduce the degradation. A method and a non-transitory computer readable medium are also disclosed.

Baone, Chaitanya Ashok↗

TOPEX Electrical Power System - Autonomous Operation

The main objective of TOPEX/Poseidon Satellite is to monitor the world's oceans for scientific study of weather and climate prediction, coastal storm warning and maritime safety.

oceans climate predictions Electrical Power System↗