Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power cable”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Variational data augmentation for a learning-based granular predictive model of power outages

As the trend in climate change continues, extreme weather events are expected to occur with increasing frequency and severity and pose a significant threat to the electric power infrastructure. Regardless of the efforts a utility puts towards hardening the grid, storm-induced damage to the utility assets such as cables and distributed energy resources (DERs) that are particularly vulnerable to such events is unavoidable. Access to a highly granular, in space and time, outage forecasting tool with long lead times (i.e., days ahead) will enhance the efficiency of service restoration efforts. Here, in this study, we propose to develop and implement a multi-model framework as an operational tool based on a granular and multi-day outage forecasting model using operational numerical weather prediction model forecasts and detailed component outage information. An innovative two-layered recurrent neural network, i.e., a long-short-term-memory (LSTM)-based variational autoencoder (VAE) framework and a sliding window are used to address the uneven distribution of different types of weather events and make better use of the time-series data. Case studies are performed to demonstrate the performance of the new framework.

54 ENVIRONMENTAL SCIENCES↗

Oak Ridge Spoofing and Interference Test Battery (OAKBAT) - Pure Tones

This dataset contains the pure 1.57542 GHz (L1) pure tone recordings provided to allow characterization of the recording equipment used to digitize the OAKBAT scenarios. The equipment includes the cable, two LNAs, and the software-defined radio. The files are binary data in the format described in the paper: Albright, A., Powers, S. Bonior, J., and Combs, F., A Tool for Furthering GNSS Security Research: The Oak Ridge Spoofing and Interference Test Battery (OAKBAT), in Proceedings of ION GNSS+ 2020, 2020. The metadata, equipment documentation and configuration files, collection procedures and more materials that allow the independent reproduction of the OAKBAT data are https://github.com/oakbat/. Additionally, this site includes a complete listing of all the RF data files, not just this series, available as part of OAKBAT.

42 ENGINEERING↗

WIRE-21 Sensor Irradiation Experiment Ready for HFIR Insertion

The ability to deploy new nuclear fuels for current or future reactor concepts requires a wealth of data regarding fuel performance during normal operation, anticipated operational occurrences, and design-basis accidents. Most of these data have historically been collected during experiments in materials test reactors, ideally with online instrumentation to collect as much data as possible. However, advanced instrumentation could also allow for in situ monitoring of fuel operating conditions during commercial reactor operation to maximize fuel utilization, reduce unnecessary conservativism in design margins, and improve operator understanding of limiting peaking factors. The latter approach would complicate fuel handling, particularly during refueling, unless the instrumentation could be placed inside the fuel rods and transmitted wirelessly to a receiver located outside the fuel’s primary pressure boundary. To this end, Westinghouse Electric Company (WEC) developed wireless sensors based on inductive coupling that can transmit information regarding fuel centerline temperatures and rod internal pressures wirelessly from within a fuel rod to a nearby instrument thimble. After testing these sensors in lower-power university research reactors, the next step is to perform high neutron fluence testing to characterize the performance of these wireless sensors under conditions that are more representative of the intended application—in this case, light-water reactors (LWRs). The removable Be (RB) positions of the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL) provide the neutron flux, experiment volume, and access to instrument leads required to achieve these sensor testing goals. This report summarizes the design, analysis, and assembly of the Wireless Instrumented RB Experiment 2021 (WIRE-21). This is the most highly instrumented irradiation experiment ever performed in HFIR. The experiment will use seven different sensing techniques to measure temperature, pressure, neutron flux, and neutron fluence during reactor operation. In addition to WEC’s wireless temperature and pressure sensors, WIRE-21 includes an array of thermocouples, self-powered neutron detectors, spatially distributed fiber optic temperature sensors, passive SiC temperature monitors, and flux wires. The design of WIRE-21 and the cabling that was installed in HFIR also provide the infrastructure to enable accelerated, economical testing of advanced sensor technologies while leveraging the extremely high neutron flux that is available in HFIR. The containment for WIRE-21 is similar to previous RB irradiation vehicles but includes a few modifications, most notably the use of integrated compression seals to pass a larger number of sensor leads through the experiment’s pressure boundary. In addition to the sensor leads, inert gas lines are passed into the experiment to enable active temperature control and the ability to pneumatically actuate a bellows-driven pressure sensor. WIRE-21 is targeting component temperatures (300–350°C) and neutron fluence levels (~10 22 n/cm 2 ) that would be expected in the plenum region of LWR fuels, except for the active sensing region of the wireless temperature sensor, which is targeting LWR fuel centerline temperatures (~800–1,100°C). WIRE-21 was successfully assembled, passed all nondestructive examination, and was delivered to HFIR for insertion during upcoming cycle 498 (April 2022).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Concentrating Solar Power Best Practices Study

The primary objective of this Concentrating Solar Power Best Practices Study is to publish best practices and lessons learned from the engineering, construction, commissioning, operations, and maintenance of existing concentrating solar power (CSP) parabolic trough and power tower systems. To accomplish this objective, information was solicited from many owners, operators, and engineering, procurement, and construction (EPC) contractors, independent engineers, and other stakeholders of parabolic trough and central receiver plants (also commonly referred to as power towers). Information was gathered through in-person or online meetings, site visits, and questionnaires sent to participants. The project team held about 50 information-gathering sessions with participants over the course this effort; and in the process, it collected information from participants representing nearly 80% of CSP plants operating worldwide.

14 SOLAR ENERGY↗

2.2.2.405 - Verdant/NREL Research Measurement Campaign

The marine renewable energy industry primarily uses thermoset composite materials for blades and other hydrodynamic components, which can have up to 50% reduction in strength when exposed to seawater and are not recyclable. Thermoplastic composite materials have been shown at a coupon-scale to have improved seawater saturated properties but have not been validated at full scale. The primary goal of the project is to demonstrate the structural properties of thermoplastic-fiberglass composite blades compared to epoxy-fiberglass composite blades in seawater at a tidal energy site on an operational turbine. Through this work, NREL manufactured, tested and deployed thermoplastic blades and a data acquisition system on Verdant Power's turbine TriFrame in the East River, NYC. The thermoplastic blades and DAQ were retrieved after a 6-month deployment with no signs of degradation and all cable connections, structural supports and strain gages had a 100% survival rate. The blades are currently undergoing post-deployment structural validation to compare their performance to traditional epoxy blades that were deployed for the same amount of time. This will increase confidence in thermoplastic materials and move it closer to commercial adoption, as well as increase confidence in the design of a DAQ and instrumentation method for a tidal turbine. However, due to an error in the DAQ software that was introduced after the DAQ and software were validated, there was no loads data collected during the deployment.

blade testing↗

Understanding Line Losses and Transformer Losses in Rural Isolated Distribution Systems: Preprint

Rural, isolated power systems in the mainland U.S. and in states like Alaska and Hawaii are powered by assets like diesel generators. These rural, isolated power systems also cannot operate at the higher band of medium voltage (like 69kV). They are primarily in the 12 to 14 kV range to keep the cost of the distribution investments lower. Because of this mid-band medium voltage range, the line losses and distribution transformers losses consume significant diesel consumption (almost 10 percent of the peak load). This work considers one such power system powering an isolated system and presents key findings online losses, and transformer losses. Understanding and documenting the impacts is critical for these communities operating their power systems and take actions to reduce expensive diesel consumption. In this paper, we will present one such typical grid and model it in electromagnetic transients (EMT) domain. We used the tower structure, under ground cabling installation to develop high fidelity models of lines. We also used high fidelity models of distribution transformers to present the no-load losses and full load loses. We will also present technical solutions available commercially off-the-shelf to reduce these losses and reduce diesel consumption. This work will be a primer for communities to understand the technical challenges and to understand the possible solution available to solve such challenges for rural, isolated power system operators.

blackstart↗

EVSE Characterization

NextGen Profiles' EVSE characterization efforts explored performance variability in production EVSE through the use of EV emulation equipment and assessed how different operational conditions influence charging behavior. Data were collected at a frequency of 10 Hz from both the EV emulator and EVSE during each charge session and stored in a time-series database for further analysis. As part of the NextGen Profiles project, characterization of high-power EVSE was performed on both conductive and wireless charging infrastructure; however, only conductive charging data are currently included in this repository. This EVSE characterization was performed over a range of DC output currents and voltages, covering both nominal and off-nominal test conditions. This EVSE characterization dataset includes high-power charging data from two types of 350-kW-capable EVSE using liquid-cooled Combined Charging System-1 (CCS1, North American version) cables and connectors. To protect confidentiality, all EVSE metadata are anonymized, and the publicly released datasets are metered at 10-Hz frequency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A new approach to the design of surface subsystems of polymeric insulators for HV and MV apparatus under AC voltage

The design of high voltage and medium voltage AC and DC standoff insulators, and, in general, of insulation systems where surface and interface properties are predominant factors, is based on specifications and standards that rely upon long-term experiences and lab testing. Surface insulating properties depend on electrical and thermal stresses, besides environmental factors, and the inception of extrinsic ageing phenomena, such as partial discharges, can be already a cause of reduced reliability and premature failure (for organic insulating materials). An innovative approach, based on field simulation, discharge modelling, and partial discharge inception measurements is presented by the authors, which can establish a solid basis to optimise insulation design for any type of supply voltage waveform. This method, the three-leg approach, is applied here to a cable system under AC sinusoidal voltage, but it can work for any type of insulation system, such as bushings, switch gears, transformers, rotating machines, and power electronics boards.

42 ENGINEERING↗

Four-Stage Multi-Physics Simulations to Assist Temperature Sensor Design for Industrial-Scale Coal-Fired Boiler

The growth of renewable energy sources presents a pressing challenge to the operation and maintenance of existing fossil fuel power plants, given that fossil fuel remains the predominant fuel source, responsible for over 60% of electricity generation in the United States. One of the main concerns within these fossil fuel power plants is the unpredictable failure of boiler tubes, resulting in emergency maintenance with significant economic and societal consequences. A reliable high-temperature sensor is necessary for in situ monitoring of boiler tubes and the safety of fossil fuel power plants. In this study, a comprehensive four-stage multi-physics computational framework is developed to assist the design, optimization installation, and operation of the high-temperature stainless-steel and quartz coaxial cable sensor (SSQ-CCS) for coal-fired boiler applications. With the consideration of various operation conditions, we predict the distributions of flue gas temperatures within coal-fired boilers, the temperature correlation between the boiler tube and SSQ-CCS, and the safety of SSQ-CCS. With the simulation-guided sensor installation plan, the newly designed SSQ-CCSs have been employed for field testing for more than 430 days. The computational framework developed in this work can guide the future operation of coal-fired plants and other power plants for the safety prediction of boiler operations.

42 ENGINEERING↗

Geometry Optimization of Cable-Based Actuation for Small-Scale Model Testing of a Floating Marine Turbine: Preprint

This research aims to apply combined wave and tidal current loads to a small-scale floating marine current turbine in a wave tank, where an actuation system applies hydrodynamic and mooring forces on the hardware based on results from a simulation. We use a real-time hybrid test setup with physical wave forcing from the wave tank and simulated current and mooring forces implemented through a tensioned cable array. For this paper, we developed an optimization algorithm that adjusts the hardware geometry of the cable array to achieve more efficient tension allocation across the cables for the loads that need to be actuated. By adjusting the points where the cables are attached to the floating platform and the angles between the platform and the winches, an optimal cable geometry can be found to minimize tension variations in the lines, maintain the desired pretension, and prevent excessive tensions. We present the optimization problem formulation, the actuation system evaluation approach, and optimization results that show effective cable actuation setups that are being considered for implementation in the wave tank tests.

cable-based actuation↗

High-Level Assessment of Grid Infrastructure in Southeast Asia to Support Regional Interconnections

The purpose of this slide deck is to provide an overview of the benefits of interregional transmission and to assess the specific transmission landscape of Southeast Asia, with respect to potential interconnections between Singapore and neighboring countries. This analysis also explores the distribution of renewable resources and electricity demand in ASEAN (the Association of Southeast Asian Nations) as well as current and anticipated interregional transmission, in order to inform future interconnection plans.

ASEAN↗

Visualizing Fault Induced Traveling Waves In Medium Voltage Systems

Traveling waves are induced in power systems during most transient events in the grid. These waves travel close to the speed of light in overhead lines and 50% to 60% the speed of light in underground cables. Even though traveling wave-based protection schemes for transmission systems are available commercially, traveling waves in medium voltage distribution networks are still in research space. Compared to transmission system, medium voltage distribution systems contain more reflections and refractions. Thus, visualization is challenging and is critical in locating faults in distribution network. To address this visualization challenge, this paper presents an open-source tool to visualize the traveling waves using Bewley lattice approach. The developed visualization tool will be useful for the protection engineers to detect and triangulate fault locations in the medium voltage systems and isolate the faults.

Bewley Lattice↗

Substation Configuration Survey for Electromagnetic Coupling Analysis

Impacts of a high-altitude electromagnetic pulse (HEMP) on the power grid are a growing concern due to the increased reliance on the power grid. A critical area of research is quantifying power system equipment response to HEMP since this is not known in general. Substation site surveys were performed at seven high voltage substations across the United States to gather substation layout and construction details pertinent to HEMP coupling calculations and component vulnerability assessments. The primary objective for the survey was to gather information on cable layouts and cable construction within substations. Additional information was also gathered on equipment present within the substations and control house layouts. This report provides information gathered from the substation surveys.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Industrial PLC Network Modeling and Parameter Identification Using Sensitivity Analysis and Mean Field Variational Inference

A multiple input multiple output (MIMO) power line communication (PLC) model for industrial facilities was developed that uses the physics of a bottom-up model but can be calibrated like top-down models. The PLC model considers 4-conductor cables (three-phase conductors and a ground conductor) and has several load types, including motor loads. The model is calibrated to data using mean field variational inference with a sensitivity analysis to reduce the parameter space. The results show that the inference method can accurately identify many of the model parameters, and the model is accurate even when the network is modified.

47 OTHER INSTRUMENTATION↗

Vis-SAGA: Visual Analytics for Situational Awareness of Grid Anomalies: Preprint

We describe supporting near real-time situational awareness of the electric distribution system by visualizing novel data from voltage sensors deployed on existing broadband cable television network equipment. Our scalable web-based visual analytics platform supports interactive geospatial exploration, time-series analysis, and summarization of grid behavior during potentially anomalous events. The broadband cable television sensor network provides observability of the electrical distribution system at a higher local spatial resolution than is typically available to most utilities, revealing the operational state of the network and aiding in the detection of abnormal behaviors or deviations from expected patterns, particularly across electric utility service areas. We outline the design and development of interactive geospatial and time-series visualization components and the scalable data services that supply metadata, historical, and real-time streams of sensor data across the network. We evaluate our platform during periods of extreme weather, demonstrating its ability to assist in detecting patterns of operation that affect power availability, quality, resiliency, and service restoration.

cable television↗

Development of a high current density, high temperature superconducting cable for pulsed magnets

Abstract A low AC loss Rare Earth Barium Copper Oxide (REBCO) cable, based on the VIPER cable technology has been developed by Commonwealth Fusion Systems for use in high field, REBCO based tokamaks. The new cable is composed of partitioned and transposed copper ‘petals’ shaped to fit together in a circular pattern with each petal containing a REBCO tape stack and insulated from each other to reduce AC losses. A stainless steel jacket adds mechanical robustness—also serving as a vessel for solder impregnation—while a tube runs through the middle for cooling purposes. Additionally, fiber optic sensors are placed under the tape stacks for quench detection. To qualify this design, a series of experiments were conducted as part of the SPARC tokamak Central Solenoid Model Coil program—to retire the risks associated with full scale, fast ramping, high flux HTS Central Solenoid (CS) and Poloidal Field (PF) coils for tokamak fusion power plants and net energy demonstrators. These risk study and risk reduction experiments include (1) AC loss measurement and model validation in the range of ~5 T/s, (2) an IxB electromagnetic loading of over 850 kN/m at the cable level and up to 300 kN/m at the stack level, (3) a transverse compression resilience of over 350 MPa, (4) manufacturability at tokamak relevant speeds and scales, (5) cable to cable joint performance, (6) fiber optic based quench detection speed, accuracy, and feasibility, and (7) overall winding pack integration and magnet assembly. The result is a cable technology, now referred to as PIT VIPER, with AC losses that measure fifteen times lower (at ~5 T/s) than its predecessor technology; a 2% or lower degradation of critical current (Ic) at high IxB electromagnetic loads; no detectable Ic degradation up to 570 MPa of transverse compression on the cable unit cell; end to end magnet manufacturing, consistently producing Ic values within 7% of the model prediction; cable to cable joint resistances at 20 K on the order of ~15 nΩ; and fast, functional quench detection capabilities that do not involve voltage taps. This cable technology will be tested comprehensively in a Central Solenoid Model Coil to prove its readiness for compact, high field tokamak operation.

Sanabria, Charlie (ORCID:0000000150175309)↗

Adaptable Monitoring Package Development and Deployment: Lessons Learned for Integrated Instrumentation at Marine Energy Sites

Integrated instrumentation packages are an attractive option for environmental and ecological monitoring at marine energy sites, as they can support a range of sensors in a form factor compact enough for the operational constraints posed by energetic waves and currents. Here we present details of the architecture and performance for one such system—the Adaptable Monitoring Package—which supports active acoustic, passive acoustic, and optical sensing to quantify the physical environment and animal presence at marine energy sites. we describe cabled and autonomous deployments and contrast the relatively limited system capabilities in an autonomous operating mode with more expansive capabilities, including real-time data processing, afforded by shore power or in situ power harvesting from waves. Across these deployments, we describe sensor performance, outcomes for biological target classification algorithms using data from multibeam sonars and optical cameras, and the effectiveness of measures to limit biofouling and corrosion. On the basis of these experiences, we discuss the demonstrated requirements for integrated instrumentation, possible operational concepts for monitoring the environmental and ecological effects of marine energy converters using such systems, and the engineering trade-offs inherent in their development. Overall, we find that integrated instrumentation can provide powerful capabilities for observing rare events, managing the volume of data collected, and mitigating potential bias to marine animal behavior. These capabilities may be as relevant to the broader oceanographic community as they are to the emerging marine energy sector.

16 TIDAL AND WAVE POWER↗

Spread Spectrum Time Domain Reflectivity for String Monitoring in PV Power Plants (Final Technical Report)

This final report describes the methods and results of applying Spread Spectrum Time Domain Reflectivity (SSTDR) for String Monitoring in PV Power Plants for DE-EE0008169. The project created a new system for both detecting and locating electrical faults in photovoltaic systems. In this work, we address photovoltaic electric faults that are both common and costly. Based on interviews with photovoltaic power plant owners, operators, and maintainers, three types of faults are common and of significant interest: disconnects, ground faults, and arc faults. Disconnects can originate from many sources. They are often due to everyday events, such as lawnmowing (accidentally running over a cable), animals eating through the cables, or degradation that occurs over time due to corrosion or general degradation. Ground faults occur when the cables (for example, due to frayed insolation) connect to the ground, relaying current into the ground. These faults are particularly problematic since the ground faults are often intermittent. That is, ground faults commonly appear during rain storms due to a change in soil conductivity and then disappear when the rain ends. This makes the ground fault difficult to find because while current systems can detect the overall change in voltage and current associated with a ground fault, technicians are necessary to locate the fault. As a result, ground faults may disappear before the technician arrives at the power plant. Hence, locating and fixing ground faults often require multiple trips. We also study arc faults, which can result when nearby conductors create an arc of electrical current through the air. While less common, arc faults can be extremely dangerous. The energetic electrical arc can cause fires and destroy equipment, costing significant damage. Overall all three types of faults cost owners and operators money, either from the destruction of equipment or from technician time. Furthermore, while devices exist for detecting ground faults (ground fault circuit interrupters) and arc faults (arc fault circuit interrupter), these systems only search patterns of electrical current that correspond to each fault. This information cannot be used to locate the fault. In addition, these protection systems experience nuisance trips due to nearby electromagnetic interference, such as from a lawn mower or other motors that produce significant amounts of electromagnetic radiation. Hence, the overall goal of this project is to create an SSTDR tool that provides photovoltaic power plants with more reliable fault detection in addition to the localization of faults. SSTDR works by transmitting electrical signals into the photovoltaic string. Those signals reflect from impedance discontinuities (i.e., disconnects, ground faults, and arc faults). These faults are then detected by measuring the presence of a reflection at the SSTDR and can be located by identifying the location of that reflection in time. In addition, unlike current protection systems, these systems do not experience nuisance trips since their low amplitude, high frequency, and coded signal can by analyzed without interference from the regular operational voltage on the photovoltaic string.

14 SOLAR ENERGY↗