Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “positron”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Positron scattering by atomic hydrogen using optical potentials and with positronium formation

The scattering is considered of positrons by H(ls) in a two-state model which incorporates optical potentials. The model explicitly describes elastic scattering, i.e., positron + H(ls) yields positron + H(ls) and Ps(ls) yields Ps(ls) + p. The inelastic processes positron + H(ls) yields positron + H* Ps(ls) + p yields Ps* + p where * stands for a state other than ls, are implicitly taken into account through the optical potentials, which also allow for polarization of H(ls) and Ps(ls).

Walters, H. R. J.↗

Positron annihilation radiation from the Galactic center region

Observations show that there are two components of positron annihilation radiation from the region of the Galactic center: a variable component resulting from one or just a few compact sources at or near the Galactic center and a steady, diffuse component resulting from positron annihilation in the Galactic disk. The diffuse component is modeled using the observed longitude distributions of 70-150 MeV gamma rays, CO, and hot plasma revealed by Fe line emission. Recent results on positron annihilation in the interstellar medium are reviewed and the implications of the annihilation processes on the fraction of positrons annihilating via positronium and on the shape of the 511 keV annihilation line are discussed. The sources of diffuse Galactic positrons are also reviewed and the nature of the compact source of annihilation radiation near the Galactic center is discussed.

Ramaty, R.↗

Compression of trapped positrons in a single particle regime by a rotating electric field

Positrons confined in a cylindrical Penning trap are compressed radially by applying a rotating electric field. Previous experiments were conducted with large numbers of positrons in the plasma state. Compression of small numbers of positrons in the single particle regime is reported for the first time. For low values of applied rf amplitude, the compression occurs in a narrow band of frequencies centered on the axial bounce frequency. For larger amplitudes, the compression extends to a broad range of frequencies below the bounce frequency. Under certain conditions, very rapid compression can be obtained and central density doubling times of only a few milliseconds have been observed. Possible models for the effect are discussed. Potential application to the production of brightness enhanced positron beams is described.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Next Generation Trap for Positron Storage

Progress toward the development of a novel multicell Penning-Malmberg trap is described that will be capable of accumulating orders of magnitude more positrons than is possible presently. This design represents the next major step in antimatter storage technology. Experiments with test electron plasmas establishing techniques critical to the implementation of a practical multicell trap are presented. The latest design for a 21 cell trap capable of accumulating and storing more than 5x10{sup 11} positrons is described. This trap could facilitate multiplexing the output of the new generation of positron sources either operating now or currently under development, as well as the potential to provide record-high bursts of positrons for a variety of applications.

74 ATOMIC AND MOLECULAR PHYSICS↗

Numerical simulation study of positron production by intense laser-accelerated electrons

Positron production by ultra-intense laser-accelerated electrons has been studied with two-dimensional particle-in-cell and Monte Carlo simulations. The dependence of the positron yield on plasma density, plasma length, and converter thickness was investigated in detail with fixed parameters of a typical 100 TW laser system. The results show that with the optimal plasma and converter parameters a positron beam containing up to 1.9 × 10{sup 10} positrons can be generated, which has a small divergence angle (10°), a high temperature (67.2 MeV), and a short pulse duration (1.7 ps)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Positron annihilation characteristics in mesostructural silica films with various porosities

Porous silica films with various porosities were prepared via a sol-gel method using a nonionic amphiphilic triblock copolymer F127 as the structure-directing agent. Doppler broadening of positron annihilation radiation (DBAR) spectra were collected for the prepared films using a variable energy slow positron beam. Different linear relationships between positron annihilation line shape parameters S and W are found for the as-deposited films and calcined ones, indicative of the decomposition of the copolymer porogen in the as-deposited films upon calcination. This also reveals the variation of positron annihilation sites as a function of F127 loading or porosity. Strong correlations between positronium 3γ annihilation fraction, S parameter and porosity of the mesoporous silica films with isolated pores are obtained, which may provide a complementary method to determine closed porosities of mesoporous silica films by DBAR.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Characterization of point defects in CdTe by positron annihilation spectroscopy

Positron lifetime measurements on CdTe 0.15% Zn-doped by weight are presented, trapping to monovacancy defects is observed. At low temperatures, localization at shallow binding energy positron traps dominates. To aid defect identification density functional theory, calculated positron lifetimes and momentum distributions are obtained using relaxed geometry configurations of the monovacancy defects and the Te antisite. These calculations provide evidence that combined positron lifetime and coincidence Doppler spectroscopy measurements have the capability to identify neutral or negative charge states of the monovacancies, the Te antisite, A-centers, and divacancy defects in CdTe.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Positron fraction in cosmic rays and models of cosmic-ray propagation

The positron fraction observed by PAMELA and other experiments up to {approx}100 GeV is analyzed in terms of models of cosmic-ray propagation. It is shown that generically we expect the positron fraction to reach {approx}0.6 at energies of several TeV, and its energy dependence bears an intimate but subtle connection with that of the boron to carbon ratio in cosmic rays. The observed positron fraction can be fit in a model that assumes a significant fraction of the boron below {approx}10 GeV is generated through spallation of cosmic-ray nuclei in a cocoonlike region surrounding the sources, and the positrons of energy higher than a few GeV are almost exclusively generated through cosmic-ray interactions in the general interstellar medium. Such a model is consistent with the bounds on cosmic-ray anisotropies and other observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Systematic study of the undulator based ILC positron source : production and capture.

A systematic study of the positron production and capturing yield for the undulatoer-based ILC positron source has been performed. We use undulator parameters of k = 0.3 - 1 , lambda = 0.7 - 1.5 cm as the reference design. The yield is defined as number of positrons captured at the damping ring input by a single electron passing through 100 meter long undulator. Several scenarios for polarizations and capturing schemes are considered here: polarized (60%) and low-polarized positrons, immersed target in magnetic field and non-immersed cases.

43 PARTICLE ACCELERATORS↗

Measurement and verification of positron emitter nuclei generated at each treatment site by target nuclear fragment reactions in proton therapy

Purpose: The purpose of this study is to verify the characteristics of the positron emitter nuclei generated at each treatment site by proton irradiation. Methods: Proton therapy using a beam on-line PET system mounted on a rotating gantry port (BOLPs-RGp), which the authors developed, is provided at the National Cancer Center Kashiwa, Japan. BOLPs-RGp is a monitoring system that can confirm the activity distribution of the proton irradiated volume by detection of a pair of annihilation gamma rays coincidentally from positron emitter nuclei generated by the target nuclear fragment reactions between irradiated proton nuclei and nuclei in the human body. Activity is measured from a start of proton irradiation to a period of 200 s after the end of the irradiation. The characteristics of the positron emitter nuclei generated in a patient's body were verified by the measurement of the activity distribution at each treatment site using BOLPs-RGp. Results: The decay curves for measured activity were able to be approximated using two or three half-life values regardless of the treatment site. The activity of half-life value of about 2 min was important for a confirmation of the proton irradiated volume. Conclusions: In each proton treatment site, verification of the characteristics of the generated positron emitter nuclei was performed by using BOLPs-RGp. For the monitoring of the proton irradiated volume, the detection of {sup 15}O generated in a human body was important.

61 RADIATION PROTECTION AND DOSIMETRY↗

An Undulator Based Polarized Positron Source for CLIC

A viable positron source scheme is proposed that uses circularly polarized gamma rays generated from the main 250 GeV electron beam. The beam passes through a helical superconducting undulator with a magnetic field of {approx} 1 Tesla and a period of 1.15 cm. The gamma-rays produced in the undulator in the energy range between {approx} 3 MeV - 100 MeV will be directed to a titanium target and produce polarized positrons. The positrons are then captured, accelerated and transported to a Pre-Damping Ring (PDR). Detailed parameter studies of this scheme including positron yield, and undulator parameter dependence are presented. Effects on the 250 GeV CLIC main beam, including emittance growth and energy loss from the beam passing through the undulator are also discussed.

43 PARTICLE ACCELERATORS↗

The impact of positron range on PET resolution, evaluated with phantoms and PHITS Monte Carlo simulations for conventional and non-conventional radionuclides

The increasing interest and availability of non-standard positron-emitting radionuclides has heightened the relevance of radionuclide choice in the development and optimization of new positron emission tomography (PET) imaging procedures, both in preclinical research and clinical practice. Differences in achievable resolution arising from positron range can largely influence application suitability of each radionuclide, especially in small-ring preclinical PET where system blurring factors due to annihilation photon acollinearity and detector geometry are less significant. Here, some resolution degradation can be mitigated with appropriate range corrections implemented during image reconstruction, the quality of which is contingent on an accurate characterization of positron range.

43 PARTICLE ACCELERATORS↗

{sup 18}F-sodium fluoride positron emission tomography assessed microcalcifications in culprit and non-culprit human carotid plaques

Background: {sup 18}F-NaF positron emission tomography (PET) targets microcalcifications. We compared in vitro microPET assessed {sup 18}F-NaF uptake between culprit and non-culprit human carotid plaques. Furthermore, we compared {sup 18}F-NaF uptake with calcification visualized on microcomputed tomography (microCT). Methods: Carotid plaques from stroke patients undergoing surgery were incubated in {sup 18}F-NaF and scanned using a microPET and a microCT scan. The average PET assessed {sup 18}F-NaF uptake was expressed as percentage of the incubation dose per gram (%Inc/g). {sup 18}F-NaF PET volume of interest (VOI) was compared with CT calcification VOI. Results: 23 carotid plaques (17 culprit, 6 non-culprit) were included. The average {sup 18}F-NaF uptake in culprit carotid plaques was comparable with the uptake in non-culprit carotid plaques (median 2.32 %Inc/g [IQR 1.98 to 2.81] vs. median 2.35 %Inc/g [IQR 1.77 to 3.00], P = 0.916). Only a median of 10% (IQR 4 to 25) of CT calcification VOI showed increased {sup 18}F-NaF uptake, while merely a median of 35% (IQR 6 to 42) of {sup 18}F-NaF PET VOI showed calcification on CT. Conclusions: {sup 18}F-NaF PET represents a different stage in the calcification process than CT. We observed a similar PET assessed {sup 18}F-NaF uptake and pattern in culprit and non-culprit plaques of high-risk patients, indicating that this method may be of more value in early atherosclerotic stenosis development. [French] French Abstract: Contexte: La tomographie par émission de positons (TEP) au {sup 18}F-NaF marque les micro-calcifications. Nous avons comparé in vitro les plaques carotidiennes humaines responsable d’accident vasculaire cérébrales marquées au {sup 18}F-NaF avec une microTEP et leur calcification au moyen d’un microCT Méthodes: Les plaques carotidiennes de patients victimes d’un accident vasculaire cérébral qui ont bénéficié d’ une intervention chirurgicale ont été incubées dans du {sup 18}F-NaF et imagées avec une microTEP et un microCT. Le pourcentage d’absorption moyen de {sup 18}F-NaF par gr de tissu (% Inc/g) ont été comparées au volume d’intérêt (VOI) des calcifications mesurées par CT. Résultats: 23 plaques carotidiennes (17 responsables d’un AVC et 6 non responsables) ont été incluses. Le % moyen d’absorption de {sup 18}F-NaF dans les plaques carotidiennes responsables furent comparable à l’absorption dans les plaques non responsables (2,32% Inc/g vs 2,35% Inc/g , p = 0,916). Dix pourcent seulement des calcifications visualisées par CT démontrèrent une augmentation d’absorption de {sup 18}F-NaF et 35% des plaques montrant une absorption de {sup 18}F-NaF PET VOI démontrèrent des calcifications au CT. Conclusions: L’imagerie de l’absorption de {sup 18}F-NaF par tomographie à positrons représente un processus physiopathologique différent de l’imagerie des calcifications par CT. L’absorption du {sup 18}F-NaF par les plaques responsables et non responsables d’accidents vasculaire cérébraux pourrait s’avérer utile dans le diagnostic précoce des sténoses athéromateuses. [Spanish] Spanish Abstract: Antecedentes: La tomografía por emisión de positrones (PET) con {sup 18}F-floruro de sodio ({sup 18}F-NaF) demuestra microcalcificaciones. En este estudio, comparamos la captación de {sup 18}F-NaF entre placas carotideas culpables y no culpables valorada con microPET in vitro. Además, comparamos la captación de {sup 18}F-NAF con las calcificaciones detectadas por microtomografía computada (microCT). Métodos: Placas carotídeas de pacientes postoperados que sufrieron de un evento vascular cerebral fueron incubadas en 18-NaF y escaneadas usando microPET y microCT. El promedio de la captación fue expresado como porcentaje de la dosis de incubación por gramo (%Inc/gr). El volumen de interés (VOI) del PET {sup 18}F-NaF se comparó con el VOI de calcificación por CT. Resultados: Se incluyeron 23 placas carotídeas (17 culpables y 6 no culpables). El promedio de la captación de {sup 18}F-NaF en placas carotídeas culpable fue comparable al de las placas no culpables. (mediana 2.32%Inc/gr [IQR1.98-2.81] vs. mediana 2.35%Inc/gr [IQR1.77-3], p=.916). Solo una mediana de 10% (IQR 4-25) del VOI en CT mostró un aumento en la captación de {sup 18}F-NaF, mientras una mediana de 35% (IQR 6-42) del VOI de PET {sup 18}F-NaF mostró calcificación en CT. Conclusiones: La tomografía por emisión de positrones con {sup 18}F-NaF evalúa una etapa distinta en el proceso de calcificación que la CT. El patrón de captación de {sup 18}F-NaF que observamos en este estudio fue similar entre placas culpables y no culpables de pacientes de alto riesgo, lo cual indica que este método puede ser de mayor valor en el desarrollo temprano de la estenosis ateroesclerótica. [Chinese] Chinese Abstract: 背景: F18 氟化钠正电子发射断层扫描 (PET) 可用于检测微钙化。我们使用微型 PET 来评估病人体外 F18 氟化钠在颈动脉罪犯和非罪犯斑块之间的的摄取区别。此外, 我们还将 F18 氟化钠的摄取与 microCT 扫描检测的钙化进行对比。 方法: 将接受手术的中风患者的颈动脉斑块在 F18 氟化钠中培养并用 microPE 和 microCT 进行扫描。PET 对 F18 氟化钠的平均摄取率表示为每克培养剂量的百分比。F18 氟化钠 PET 中的感兴趣区域和 CT 钙化图像中的感兴趣区域 (VOI) 进行比较。 结果: 一共有 23个颈动脉斑块, 其中 17个罪犯斑块和 6个非罪犯斑块。罪犯和非罪犯颈动脉斑块的 F18 氟化钠的平均摄取率无明显差异 (中值 2.32 % Inc/g [IQR 1.98-2.81] vs. 中值2.35 % Inc/g [IQR 1.77-3.00], p = 0.916)。仅中值为10% [IQR 4-25] 的 CT 钙化 VOI 显示有F18氟化钠的摄取增加, 中值为 35%[IQR 6-42] 的 F18 氟化钠 PET VOI 显示有CT 上的钙化。 结论: 相较于 CT, F18 氟化钠 PET 展现了钙化过程中的一个不同阶段。在高危病人中, 我们观察到罪犯和非罪犯斑块具有类似的 PET F18 氟化钠摄取和模式, 表明该方法可能在早期动脉粥样硬化狭窄发展中具有更高的价值。.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The E166 Experiment: Undulator-Based Production of Polarized Positrons

A proof-of-principle experiment has been carried out in the Final Focus Test Beam (FFTB) at SLAC to demonstrate production of polarized positrons in a manner suitable for implementation at the ILC. A helical undulator of 2.54 mm period and 1-m length produced circularly polarized photons of first harmonic endpoint energy of 8 MeV when traversed by a 46.6 GeV electron beam. The polarized photons were converted to polarized positrons in a 0.2-radiation-length tungsten target. The polarization of these positrons was measured at several energies, with a peak value in excess of 80%, by transmission polarimetry of photons obtained on reconversion of the positrons in a second tungsten target.

43 PARTICLE ACCELERATORS↗

Pair annihilation effects on a surface ion cyclotron wave in semibounded electron-positron-ion plasmas

Electron-positron pair annihilation effects on a surface ion cyclotron wave are investigated in magnetized electron-positron-ion plasmas in atmospheres of neutron stars. The dispersion relation of the surface ion cyclotron wave is obtained by the specular reflection boundary condition with the plasma dielectric function. It is shown that the high- and low-frequency modes of the surface ion cyclotron wave could exist in electron-positron-ion plasmas. For the high-frequency mode, the pair annihilation enhances the wave frequency in large wave-number domains. However, the pair annihilation effects are found to be negligible for the low-frequency mode. It is also found that an increase of the electron temperature or a decrease of the positron temperature strongly suppresses the wave frequency. It is shown that an increase of the magnetic field strongly enhances the wave frequency.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nonlinear Korteweg-de Vries equation for soliton propagation in relativistic electron-positron-ion plasma with thermal ions

The nonlinear propagation of ion-acoustic solitons in relativistic electron-positron-ion plasma comprising of Boltzmannian electrons, positrons, and relativistic thermal ions has been examined. The Korteweg-de Vries equation has been derived by reductive perturbation technique. The effect of various plasma parameters on amplitude and structure of solitary wave is investigated. The pert graphical view of the results has been presented for illustration. It is observed that increase in the relativistic streaming factor causes the soliton amplitude to thrive and its width shrinks. The soliton amplitude and width decline as the ion to electron temperature ratio is increased. The increase in positron concentration results in reduction of soliton amplitude. The soliton amplitude enhances as the electron to positron temperature ratio is increased. Our results may have relevance in the understanding of astrophysical plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ion-acoustic nonlinear periodic waves in electron-positron-ion plasma

Ion-acoustic nonlinear periodic waves, namely, ion-acoustic cnoidal waves have been studied in electron-positron-ion plasma. Using reductive perturbation method and appropriate boundary condition for nonlinear periodic waves, the Korteweg-de Vries (KdV) equation is derived for the system. The cnoidal wave solution of the KdV equation is discussed in detail. It is found that the frequency of the cnoidal wave is a function of its amplitude. It is also found that the positron concentration modifies the properties of the ion-acoustic cnoidal waves. The existence regions for ion-acoustic cnoidal wave in the parameters space (p,{sigma}), where p and {sigma} are the positron concentration and temperature ratio of electron to positron, are discussed in detail. In the limiting case these ion-acoustic cnoidal waves reduce to the ion-acoustic soliton solutions. The effect of other parameters on the characteristics of the nonlinear periodic waves is also discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Oxygen-Atom Defects In 6H Silicon Carbide Implanted Using 24- MeV O{sup 3+} Ions Measured Using Three-Dimensional Positron Annihilation Spectroscopy System (3DPASS)

Three dimensional electron-positron (e{sup -}-e{sup +}) momentum distributions were measured for single crystal 6H silicon carbide (SiC); both virgin and having implanted oxygen-atom defects. 6H SiC samples were irradiated by 24- MeV O{sup 3+} ions at 20 particle-nanoamps at the Sandia National Laboratory's Ion Beam Facility. O{sup 3+} ions were implanted 10.8 {mu}m deep normal to the (0001) face of one side of the SiC samples. During positron annihilation measurements, the opposite face of the 254.0-{mu}m thick SiC samples was exposed to positrons from a {sup 22}Na source. This technique reduced the influence on the momentum measurements of vacancy-type defects resulting from knock-on damage by the O{sup 3+} ions. A three-dimensional positron annihilation spectroscopy system (3DPASS) was used to measure e{sup -}-e{sup +} momentum distributions for virgin and irradiated 6H SiC crystal both before and following annealing. 3DPASS simultaneously measures coincident Doppler-broadening (DBAR) and angular correlation of annihilation radiation (ACAR) spectra. DBAR ratio plots and 2D ACAR spectra are presented. Changes in the momentum anisotropies relative to crystal orientation observed in 2D ACAR spectra for annealed O-implanted SiC agree with the local structure of defect distortion predicted using Surface Integrated Molecular Orbital/Molecular Mechanics (SIMOMM). Oxygen atoms insert between Si and C atoms increasing their separation by 0.9 A forming a Si-O-C bond angle of {approx}150 deg.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗